Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36531804

RESUMEN

Oral squamous cell carcinoma (OSCC) is one of the most common lip and oral cavity cancer types. It requires early detection via various medical technologies to improve the survival rate. While most detection techniques for OSCC require testing in a centralized lab to confirm cancer type, a point of care detection technique is preferred for on-site use and quick result readout. The modular biological sensor utilizing transistor-based technology has been leveraged for testing CIP2A, and optimal transistor gate voltage and load resistance for sensing setup was investigated. Sensitivities of 1 × 10-15 g/ml have been obtained for both detections of pure CIP2A protein and HeLa cell lysate using identical test conditions via serial dilution. The superior time-saving and high accuracy testing provides opportunities for rapid clinical diagnosis in the medical space.

2.
J Funct Biomater ; 13(4)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36412888

RESUMEN

The objective of this study was to evaluate the influence of the titanium nanotube diameter and the effect of silicon carbide (SiC) coating on the proliferation and mineralization of pre-osteoblasts on titanium nanostructured surfaces. Anodized titanium sheets with nanotube diameters of 50 and 100 nm were used. The following four groups were tested in the study: (1) non-coated 50 nm nanotubes; (2) SiC-coated 50 nm titanium nanotubes; (3) non-coated 100 nm nanotubes and (4) SiC-coated 100 nm nanotubes. The biocompatibility and cytotoxicity of pre-osteoblasts were evaluated using a CellTiter-BlueCell Viability assay after 1, 2, and 3 days. After 3 days, cells attached to the surface were observed by SEM. Pre-osteoblast mineralization was determined using Alizarin-Red staining solution after 21 days of cultivation. Data were analyzed by a Kruskal−Wallis test at a p-value of 0.05. The results evidenced biocompatibility and non-cytotoxicity of both 50 and 100 nm diameter coated and non-coated surfaces after 1, 2 and 3 days. The statistical analysis indicates a statistically significant higher cell growth at 3 days (p < 0.05). SEM images after 3 days demonstrated flattened-shaped cells without any noticeable difference in the phenotypes between different diameters or surface treatments. After 21 days of induced osteogenic differentiation, the statistical analysis indicates significantly higher osteoblast calcification on coated groups of both diameters when compared with non-coated groups (p < 0.05). Based on these results, we can conclude that the titanium nanotube diameter did not play any role on cell viability or mineralization of pre-osteoblasts on SiC-coated or non-coated titanium nanotube sheets. The SiC coating demonstrated biocompatibility and non-cytotoxicity and contributed to an increase in osteoblast mineralization on titanium nanostructured surfaces when compared to non-coated groups.

3.
Artículo en Inglés | MEDLINE | ID: mdl-36032198

RESUMEN

Leakage of human cerebrospinal fluid (CSF) caused by trauma or other reasons presents exceptional challenges in clinical analysis and can have severe medical repercussions. Conventional test methods, including enzyme-linked immunosorbent assay and immunofixation electrophoresis testing, typically are performed at a few clinical reference laboratories, which may potentially delay proper diagnosis and treatment. At the same time, medical imaging can serve as a secondary diagnosis tool. This work presented here reports the use of a point-of-care electrochemical sensor for detection of beta-2-transferrin (B2T), a unique isomer of transferrin that is present exclusively in human CSF but is absent in other bodily fluids. Limits of detection were examined via serial dilution of human samples with known B2T concentrations down to 7 × 10-12 g B2T/ml while maintaining excellent sensitivity. Nine human samples with varying levels of B2T were compared using up to 100 times dilution to confirm the validity of sensor output across different patient samples.

4.
Artículo en Inglés | MEDLINE | ID: mdl-36032199

RESUMEN

The SARS-CoV-2 pandemic has had a significant impact worldwide. Currently, the most common detection methods for the virus are polymerase chain reaction (PCR) and lateral flow tests. PCR takes more than an hour to obtain the results and lateral flow tests have difficulty with detecting the virus at low concentrations. In this study, 60 clinical human saliva samples, which included 30 positive and 30 negative samples confirmed with RT-PCR, were screened for COVID-19 using disposable glucose biosensor strips and a reusable printed circuit board. The disposable strips were gold plated and functionalized to immobilize antibodies on the gold film. After functionalization, the strips were connected to the gate electrode of a metal-oxide-semiconductor field-effect transistor on the printed circuit board to amplify the test signals. A synchronous double-pulsed bias voltage was applied to the drain of the transistor and strips. The resulting change in drain waveforms was converted to digital readings. The RT-PCR-confirmed saliva samples were tested again using quantitative PCR (RT-qPCR) to determine cycling threshold (Ct) values. Ct values up to 45 refer to the number of amplification cycles needed to detect the presence of the virus. These PCR results were compared with digital readings from the sensor to better evaluate the sensor technology. The results indicate that the samples with a range of Ct values from 17.8 to 35 can be differentiated, which highlights the increased sensitivity of this sensor technology. This research exhibits the potential of this biosensor technology to be further developed into a cost-effective, point-of-care, and portable rapid detection method for SARS-CoV-2.

5.
Materials (Basel) ; 15(15)2022 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-35955196

RESUMEN

The objective of this research was to quantify the effect of surface degradation and abrasion separately and in combination on the flexural strength of lithia disilicate ceramics. Lithia disilicate disks were fabricated using the lost wax technique and pressing in vacuum. The eight groups in this pilot experiment were (i) reference, hydrated in distilled water for 24 h prior to fracture; (ii) reference, non-hydrated group; (iii) 28-day pH cycling group; (iv) 125K chewing cycle group; (v) combined pH cycling + 125K chewing cycle; (vi) constant pH 2 solution for 28 days; (vii) constant pH 7 solution for 28 days; and (viii) constant pH 10 solution for 28 days. pH cycling is a method that alternates between pH 2, 7 and 10 over 28 days. A total of 15 disks were used for each group. All the groups were tested using the biaxial piston and a three-ball flexural strength test to obtain their biaxial flexural strength. pH 2 constant immersion demonstrated the highest fracture strength and was significantly greater than all other groups (p < 0.0001). Chewing and pH cycling + chewing groups exhibited the lowest fracture strengths and were significantly lower than all other groups (p < 0.0001). The damage observed from the chewing simulator does not represent apparent clinical fractures.

6.
Artículo en Inglés | MEDLINE | ID: mdl-34055475

RESUMEN

Detection of the SARS-CoV-2 spike protein and inactivated virus was achieved using disposable and biofunctionalized functional strips, which can be connected externally to a reusable printed circuit board for signal amplification with an embedded metal-oxide-semiconductor field-effect transistor (MOSFET). A series of chemical reactions was performed to immobilize both a monoclonal antibody and a polyclonal antibody onto the Au-plated electrode used as the sensing surface. An important step in the biofunctionalization, namely, the formation of Au-plated clusters on the sensor strips, was verified by scanning electron microscopy, as well as electrical measurements, to confirm successful binding of thiol groups on this Au surface. The functionalized sensor was externally connected to the gate electrode of the MOSFET, and synchronous pulses were applied to both the sensing strip and the drain contact of the MOSFET. The resulting changes in the dynamics of drain waveforms were converted into analog voltages and digital readouts, which correlate with the concentration of proteins and virus present in the tested solution. A broad range of protein concentrations from 1 fg/ml to 10 µg/ml and virus concentrations from 100 to 2500 PFU/ml were detectable for the sensor functionalized with both antibodies. The results show the potential of this approach for the development of a portable, low-cost, and disposable cartridge sensor system for point-of-care detection of viral diseases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...