Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Phys Med ; 125: 104495, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39098107

RESUMEN

BACKGROUND: Surface-guided imaging (SGI) is increasingly utilized to monitor patient motion during deep inspiration breath hold (DIBH) in radiotherapy. Understanding the association between surface and internal motion is crucial for effective monitoring. PURPOSE: To investigate the relation between motion detected by SGI using surface-guided radiotherapy (SGRT) and internal motion measured through diaphragm tracking on kV projections acquired with DIBH for online CBCT. METHODS: Both SGI and kV were simultaneously acquired for ten patients over a total of 200 breath holds (BH). Diaphragm tracking was performed using second-degree polynomial curve fitting on the derivative images for each kV projection and high-pass filtering at 1/30 Hz to remove rotational effects. The superior-inferior (SI) and anterior-posterior (AP) motions of SGI were then compared to kV tracking using various statistical measures. RESULTS: The correlation (individuals' median: -0.07 to 0.73) was a suboptimal metric for the BH data. The median and 95th percentile absolute differences between SGI-SI and kV were 0.73 mm and 3.46 mm, respectively, during DIBH. For SGI-AP, the corresponding values were 0.55 mm and 2.80 mm. For inter-BH measurements, the contingency table based on a 3 mm threshold indicated surface/diaphragm motion agreement for SGI-SI/kV and SGI-AP/kV was 61 % and 56 %, respectively. CONCLUSION: Both intra- and inter-BH measurements indicated a limited association between surface and diaphragm motion, with certain constraints noted due to kV tracking and DIBH data. These findings warrant further investigation into the association between surface and internal motion.


Asunto(s)
Contencion de la Respiración , Diafragma , Movimiento , Humanos , Diafragma/diagnóstico por imagen , Diafragma/fisiología , Tomografía Computarizada de Haz Cónico/métodos , Inhalación , Radioterapia Guiada por Imagen/métodos , Masculino , Procesamiento de Imagen Asistido por Computador/métodos , Femenino , Persona de Mediana Edad
2.
Biomed Phys Eng Express ; 10(2)2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38241733

RESUMEN

This study explored the feasibility of on-couch intensity modulated radiotherapy (IMRT) planning for prostate cancer (PCa) on a cone-beam CT (CBCT)-based online adaptive RT platform without an individualized pre-treatment plan and contours. Ten patients with PCa previously treated with image-guided IMRT (60 Gy/20 fractions) were selected. In contrast to the routine online adaptive RT workflow, a novel approach was employed in which the same preplan that was optimized on one reference patient was adapted to generate individual on-couch/initial plans for the other nine test patients using Ethos emulator. Simulation CTs of the test patients were used as simulated online CBCT (sCBCT) for emulation. Quality assessments were conducted on synthetic CTs (sCT). Dosimetric comparisons were performed between on-couch plans, on-couch plans recomputed on the sCBCT and individually optimized plans for test patients. The median value of mean absolute difference between sCT and sCBCT was 74.7 HU (range 69.5-91.5 HU). The average CTV/PTV coverage by prescription dose was 100.0%/94.7%, and normal tissue constraints were met for the nine test patients in on-couch plans on sCT. Recalculating on-couch plans on the sCBCT showed about 0.7% reduction of PTV coverage and a 0.6% increasing of hotspot, and the dose difference of the OARs was negligible (<0.5 Gy). Hence, initial IMRT plans for new patients can be generated by adapting a reference patient's preplan with online contours, which had similar qualities to the conventional approach of individually optimized plan on the simulation CT. Further study is needed to identify selection criteria for patient anatomy most amenable to this workflow.


Asunto(s)
Neoplasias de la Próstata , Radioterapia Guiada por Imagen , Masculino , Humanos , Estudios de Factibilidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia
3.
Brachytherapy ; 22(5): 580-585, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37474438

RESUMEN

PURPOSE: We present a case study of the treatment of localized squamous cell carcinoma on the glans penis with a custom-fabricated high-dose-rate (HDR) brachytherapy applicator. METHODS AND MATERIALS: A cylindrically shaped applicator was fabricated with eight embedded channels suitable for standard plastic brachytherapy catheters. An additional custom silicone bolus/sleeve was designed to be used with the 3D-printed applicator to provide an additional offset from the source to skin to reduce the surface dose and for patient comfort. RESULTS: The patient (recurrent cT1a penile cancer) underwent CT simulation, and the brachytherapy plan was created with a nominal prescription dose of 40 Gy in 10 fractions given bidaily to the surface, and 35 Gy at 5 mm depth. Dose coverage to the clinical target volume was 94% (D90). Most fractions were treated with only 5-10 min of setup time. Follow up visits up to 1 year showed no evidence of disease with no significant changes in urinary and sexual function and limited cosmetic detriment to the patient. CONCLUSIONS: Patient-specific organ-sparing HDR plesiotherapy using 3D printing technology can provide reliable and reproducible patient setup and may be effective in achieving disease control for superficial penile cancer, although preserving patient quality of life.


Asunto(s)
Braquiterapia , Neoplasias del Pene , Masculino , Humanos , Neoplasias del Pene/radioterapia , Neoplasias del Pene/patología , Tratamientos Conservadores del Órgano , Dosificación Radioterapéutica , Braquiterapia/métodos , Calidad de Vida , Planificación de la Radioterapia Asistida por Computador/métodos , Recurrencia Local de Neoplasia , Impresión Tridimensional
4.
J Appl Clin Med Phys ; 24(2): e13893, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36585853

RESUMEN

BACKGROUND: Active breathing coordinator (ABC)-assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left-sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported. PURPOSE: To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three-field technique. METHODS: From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH-based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed. RESULTS: A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%-116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%-131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%-131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%). CONCLUSION: ABC-assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments.


Asunto(s)
Neoplasias de la Mama , Neoplasias de Mama Unilaterales , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Contencion de la Respiración , Dosificación Radioterapéutica , Estudios de Factibilidad , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Neoplasias de Mama Unilaterales/radioterapia , Corazón/efectos de la radiación
5.
Biomed Phys Eng Express ; 9(1)2022 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-36541531

RESUMEN

Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy,Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25,Results. The x-ray unit's mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [-3.6,+0.4]% and [-3.7,+1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm2collimator was (-0.7 ± 1.0)%,Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements,Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.


Asunto(s)
Agua , Rayos X , Reproducibilidad de los Resultados
6.
3D Print Med ; 8(1): 22, 2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-35844030

RESUMEN

BACKGROUND: Malignancies of the head and neck region, encompassing cutaneous, mucosal, and sarcomatous histologies, are complex entities to manage, comprising of coordination between surgery, radiation therapy, and systemic therapy. Malignancies of the posterior scalp are particular challenging to treat with radiation therapy, given its irregular contours and anatomy as well as the superficial location of the target volume. Bolus material is commonly used in radiation therapy to ensure that the dose to the skin and subcutaneous tissue is appropriate and adequate, accounting for the buildup effect of megavoltage photon treatment. The use of commercially available bolus material on the posterior scalp potentially creates air gaps between the bolus and posterior scalp. CASE PRESENTATIONS: In this report, we created and utilized a custom 3D-printed integrated bolus and headrest for 5 patients to irradiate malignancies involving the posterior scalp, including those with cutaneous squamous cell carcinoma, melanoma, malignant peripheral nerve sheath tumor, and dermal sarcoma. Treatment setup was consistently reproducible, and patients tolerated treatment well without any unexpected adverse effects. CONCLUSIONS: We found that the use of this custom 3D-printed integrated bolus/headrest allowed for comfortable, consistent, and reproducible treatment set up while minimizing the risk of creating significant air gaps and should be considered in the radiotherapeutic management of patients with posterior scalp malignancies.

7.
Pract Radiat Oncol ; 12(3): e177-e182, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35150897

RESUMEN

In 2019, our institution became the second in the world to go live with GammaPod (Xcision Medical Systems, LLC, Columbia, MD), a device dedicated for stereotactic radiation therapy of breast cancer, with breast immobilization, real-time imaging, and highly-conformal dosimetry. At our institution, GammaPod is used for 5-fraction adjuvant partial breast irradiation, single-fraction tumor cavity boost before whole-breast irradiation, single-fraction preoperative radiation, and (in poor surgical candidates), single-fraction definitive radiation. Here, we describe our workflow, observed procedure step times, and homegrown techniques for improved efficiency in our institutional experience of 93 patients treated between 2019 and 2021.


Asunto(s)
Neoplasias de la Mama , Radiocirugia , Mama , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mastectomía Segmentaria , Radiometría , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Flujo de Trabajo
8.
Transplant Cell Ther ; 28(2): 113.e1-113.e8, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34775145

RESUMEN

Total body irradiation is an important part of the conditioning regimens frequently used to prepare patients for allogeneic hematopoietic stem cell transplantation (SCT). Volumetric-modulated arc therapy enabled total body irradiation (VMAT-TBI), an alternative to conventional TBI (cTBI), is a novel radiotherapy treatment technique that has been implemented and investigated in our institution. The purpose of this study is to (1) report our six-year clinical experience in terms of treatment planning strategy and delivery time and (2) evaluate the clinical outcomes and toxicities in our cohort of patients treated with VMAT-TBI. This is a retrospective single center study. Forty-four patients at our institution received VMAT-TBI and chemotherapy conditioning followed by allogeneic SCT between 2014 and 2020. Thirty-two patients (73%) received standard-dose TBI (12-13.2 Gy in 6-8 fractions twice daily), whereas 12 (27%) received low-dose TBI (2-4 Gy in one fraction). Treatment planning, delivery, and treatment outcome data including overall survival (OS), relapse-free survival (RFS), and toxicities were analyzed. The developed VMAT-TBI planning strategy consistently generated plans satisfying our dose constraints, with planning target volume coverage >90%, mean lung dose ∼50% to 75% of prescription dose, and minimal hotspots in critical organs. Most of the treatment deliveries were <100 minutes (range 33-147, mean 72). The median follow-up was 26 months. At the last follow-up, 34 of 44 (77%) of patients were alive, with 1- and 2-year OS of 90% and 79% and RFS of 88% and 71%, respectively. The most common grade 3+ toxicities observed were mucositis (31 patients [71%]) and nephrotoxicity (6 patients [13%]), both of which were deemed multifactorial in cause. Four patients (9%) in standard-dose cohort developed grade 3+ pneumonitis, with 3 cases in the setting of documented respiratory infection and only 1 (2%) deemed likely related to radiation alone. VMAT-TBI provides a safe alternative to cTBI. The dose modulation capability of VMAT-TBI may lead to new treatment strategies, such as simultaneous boost and further critical organ sparing, for better malignant cell eradication, immune suppression, and lower toxicities.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Irradiación Corporal Total
9.
Int J Radiat Oncol Biol Phys ; 110(5): 1519-1529, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33775857

RESUMEN

PURPOSE: To develop a noninvasive prognostic imaging biomarker related to hypoxia to predict SABR tumor control. METHODS AND MATERIALS: A total of 145 subcutaneous syngeneic Dunning prostate R3327-AT1 rat tumors were focally irradiated once using cone beam computed tomography guidance on a small animal irradiator at 225 kV. Various doses in the range of 0 to 100 Gy were administered, while rats breathed air or oxygen, and tumor control was assessed up to 200 days. Oxygen-sensitive magnetic resonance imaging (MRI) (T1-weighted, ΔR1, ΔR2*) was applied to 79 of these tumors at 4.7 T to assess response to an oxygen gas breathing challenge on the day before irradiation as a probe of tumor hypoxia. RESULTS: Increasing radiation dose in the range of 0 to 90 Gy enhanced tumor control of air-breathing rats with a TCD50 estimated at 59.6 ± 1.5 Gy. Control was significantly improved at some doses when rats breathed oxygen during irradiation (eg, 40 Gy; P < .05), and overall there was a modest left shift in the control curve: TCD50(oxygen) = 53.1 ± 3.1 Gy (P < .05 vs air). Oxygen-sensitive MRI showed variable response to oxygen gas breathing challenge; the magnitude of T1-weighted signal response (%ΔSI) allowed stratification of tumors in terms of local control at 40 Gy. Tumors showing %ΔSI >0.922 with O2-gas breathing challenge showed significantly better control at 40 Gy during irradiation while breathing oxygen (75% vs 0%, P < .01). In addition, increased radiation dose (50 Gy) substantially overcame resistance, with 50% control for poorly oxygenated tumors. Stratification of dose-response curves based on %ΔSI >0.922 revealed different survival curves, with TCD50 = 36.2 ± 3.2 Gy for tumors responsive to oxygen gas breathing challenge; this was significantly less than the 54.7 ± 2.4 Gy for unresponsive tumors (P < .005), irrespective of the gas inhaled during tumor irradiation. CONCLUSIONS: Oxygen-sensitive MRI allowed stratification of tumors in terms of local control at 40 Gy, indicating its use as a potential predictive imaging biomarker. Increasing dose to 50 Gy overcame radiation resistance attributable to hypoxia in 50% of tumors.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Oxígeno/administración & dosificación , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Tolerancia a Radiación , Radioterapia Guiada por Imagen/métodos , Hipoxia Tumoral , Aire , Animales , Biomarcadores , Tomografía Computarizada de Haz Cónico , Relación Dosis-Respuesta en la Radiación , Masculino , Trasplante de Neoplasias , Pronóstico , Neoplasias de la Próstata/fisiopatología , Dosificación Radioterapéutica , Ratas , Factores de Tiempo
10.
Brachytherapy ; 19(6): 800-811, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32690386

RESUMEN

PURPOSE: The purpose of this study was to manufacture a realistic and inexpensive prostate phantom to support training programs for ultrasound-based interstitial prostate brachytherapy. METHODS AND MATERIALS: Five phantom material combinations were tested and evaluated for material characteristics; Ecoflex 00-30 silicone, emulsion silicone with 20% or 50% mineral oil, and regular or supersoft polyvinyl chloride (PVC). A prostate phantom which includes an anatomic simulated prostate, urethra, seminal vesicles, rectum, and normal surrounding tissue was created with 3D-printed molds using 20% emulsion silicone and regular and supersoft PVC materials based on speed of sound testing. Needle artifact retention was evaluated at weekly intervals. RESULTS: Speed of sound testing demonstrated PVC to have the closest ultrasound characteristics of the materials tested to that of soft tissue. Several molds were created with 3D-printed PLA directly or cast on 3D-printed PLA with high heat resistant silicone. The prostate phantom fabrication workflow was developed, including a method to produce dummy seeds for low-dose-rate brachytherapy practice. A complete phantom may be fabricated in 1.5-2 h, and the material cost for each phantom was approximated at $23.98. CONCLUSIONS: A low-cost and reusable phantom was developed based on 3D-printed molds for casting. The proposed educational prostate phantom is an ideal cost-effective platform to develop and build confidence in fundamental brachytherapy procedural skills in addition to actual patient caseloads.


Asunto(s)
Braquiterapia/instrumentación , Impresión Tridimensional , Neoplasias de la Próstata/radioterapia , Oncología por Radiación/educación , Entrenamiento Simulado , Braquiterapia/métodos , Humanos , Masculino , Fantasmas de Imagen/economía , Cloruro de Polivinilo , Impresión Tridimensional/economía , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Ultrasonografía
11.
Radiat Oncol ; 14(1): 193, 2019 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-31684993

RESUMEN

INTRODUCTION: Stereotactic body radiation therapy (SBRT) was found effective in treating laryngeal cancer with only five treatment fractions by a recent clinical trial (NCT01984502, ClinicalTrials.gov). Nevertheless, this trial used the Cyberknife system, which is not widely accessible enough to benefit all patients affected by laryngeal cancer. Our study investigates the feasibility of larynx SBRT treatment planning on a conventional gantry-based LINAC and compares its plan quality with that from the Cyberknife. MATERIALS & METHODS: Ten larynx SBRT cases were originally treated by Cyberknife using fixed cones in our institution, with plans created and optimized using the Monte-Carlo algorithm in the MultiPlan treatment planning system. These cases were retrospectively planned in the Eclipse planning system for a LINAC with the same prescription dose. We used volumetric modulated arc therapy (VMAT) for larynx SBRT planning in Eclipse and incorporated non-coplanar arcs to approach the Cyberknife's large solid angle delivery space. We used both anisotropic analytical algorithm (AAA) and Acuros XB (AXB) algorithm for dose calculation and compared their accuracy by measurements on an in-house larynx phantom. We compared the LINAC VMAT plans (VMAT-AAA and VMAT-AXB) with the original Cyberknife plans using dosimetric endpoints such as the conformity index, gradient indices (R50, R20), OAR maximum/mean doses, and the monitor units. RESULTS: Phantom measurement showed that both the AAA and the AXB algorithms provided adequate dose calculation accuracy (94.7% gamma pass rate on 2%/2 mm criteria for AAA vs. 97.3% for AXB), though AXB provided better accuracy in the air cavity. The LINAC-based VMAT plans achieved similar dosimetric endpoints as the Cyberknife planning, and all plans met the larynx SBRT dosimetric constraints. Cyberknife plans achieved an average conformity index of 1.13, compared to 1.20 of VMAT-AXB and 1.19 of VMAT-AAA. The VMAT plans spared the thyroid gland better with average Dmean of 2.4 Gy (VMAT-AXB) and 2.7 Gy (VMAT-AAA), as compared to 4.3 Gy for Cyberknife plans. The VMAT-AAA plans had a slightly lower contralateral arytenoid Dmax (average: 15.2 Gy) than Cyberknife plans (average: 17.9 Gy) with statistical significance, while the contralateral arytenoid Dmax was similar between VMAT-AXB and Cyberknife plans with no statistically significant difference. Cyberknife plans offered slightly better R50 (average: 5.0) than VMAT-AXB (5.9) and VMAT-AAA (5.7) plans. The VMAT plans substantially reduced the plan MUs to less than 1/3 of the Cyberknife plans, and the differences were statistically significant. The other metrics were similar between VMAT and Cyberknife plans with no statistically significant differences. CONCLUSIONS: Gantry-based LINACs can achieve similar plan quality to Cyberknife systems. Treatment outcome with both methods remains to be investigated.


Asunto(s)
Benchmarking/métodos , Glotis , Neoplasias Laríngeas/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Humanos , Neoplasias Laríngeas/patología , Estadificación de Neoplasias , Fantasmas de Imagen , Dosificación Radioterapéutica , Estudios Retrospectivos
12.
J Appl Clin Med Phys ; 20(10): 33-42, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31471950

RESUMEN

The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (PDD) curves, beam profiles, output factors, leaf transmission factors and dosimetric leaf gaps (DLGs) were acquired in accordance with the AAPM task group reports No. 45 and No. 106 and the vendor-supplied documents. The measured data were imported into Eclipse TPS to build a VersaHD beam model. The model was validated by creating treatment plans spanning over the full-spectrum of treatment sites and techniques used in our clinic. The quality assurance measurements were performed using MatriXX, ionization chamber, and radiochromic film. The DLG values were iteratively adjusted to optimize the agreement between planned and measured doses. Mobius, an independent LINAC logfile-based quality assurance tool, was also commissioned both for routine intensity-modulated radiation therapy (IMRT) QA and as a secondary check for the Eclipse VersaHD model. The Eclipse-generated VersaHD model was in excellent agreement with the measured PDD curves and beam profiles. The measured leaf transmission factors were less than 0.5% for all energies. The model validation study yielded absolute point dose agreement between ionization chamber measurements and Eclipse within ±4% for all cases. The comparison between Mobius and Eclipse, and between Mobius and ionization chamber measurements lead to absolute point dose agreement within ±5%. The corresponding 3D dose distributions evaluated with 3%global/2mm gamma criteria resulted in larger than 90% passing rates for all plans. The Eclipse TPS can model VersaHD LINACs with clinically acceptable accuracy. The model validation study and comparisons with Mobius demonstrated that the modeling of VersaHD in Eclipse necessitates further improvement to provide dosimetric accuracy on par with Varian LINACs.


Asunto(s)
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Fotones , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
13.
Radiother Oncol ; 133: 183-192, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30448003

RESUMEN

PURPOSE: To improve the accuracy of liver tumor localization, this study tests a biomechanical modeling-guided liver cone-beam CT (CBCT) estimation (Bio-CBCT-est) technique, which generates new CBCTs by deforming a prior high-quality CT or CBCT image using deformation vector fields (DVFs). The DVFs can be used to propagate tumor contours from the prior image to new CBCTs for automatic 4D tumor localization. METHODS/MATERIALS: To solve the DVFs, the Bio-CBCT-est technique employs an iterative scheme that alternates between intensity-driven 2D-3D deformation and biomechanical modeling-guided DVF regularization and optimization. The 2D-3D deformation step solves DVFs by matching digitally reconstructed radiographs of the 3D deformed prior image to 2D phase-sorted on-board projections according to imaging intensities. This step's accuracy is limited at low-contrast intra-liver regions without sufficient intensity variations. To boost the DVF accuracy in these regions, we use the intensity-driven DVFs solved at higher-contrast liver boundaries to fine-tune the intra-liver DVFs by finite element analysis-based biomechanical modeling. We evaluated Bio-CBCT-est's accuracy with seven liver cancer patient cases. For each patient, we simulated 4D cone-beam projections from 4D-CT images, and used these projections for Bio-CBCT-est based image estimations. After Bio-CBCT-est, the DVF-propagated liver tumor/cyst contours were quantitatively compared with the manual contours on the original 4D-CT 'reference' images, using the DICE similarity index, the center-of-mass-error (COME), the Hausdorff distance (HD) and the voxel-wise cross-correlation (CC) metrics. In addition to simulation, we also performed a preliminary study to qualitatively evaluate the Bio-CBCT-est technique via clinically acquired cone beam projections. A quantitative study using an in-house deformable liver phantom was also performed. RESULTS: Using 20 projections for image estimation, the average (±s.d.) DICE index increased from 0.48 ±â€¯0.13 (by 2D-3D deformation) to 0.77 ±â€¯0.08 (by Bio-CBCT-est), the average COME decreased from 7.7 ±â€¯1.5 mm to 2.2 ±â€¯1.2 mm, the average HD decreased from 10.6 ±â€¯2.2 mm to 5.9 ±â€¯2.0 mm, and the average CC increased from -0.004 ±â€¯0.216 to 0.422 ±â€¯0.206. The tumor/cyst trajectory solved by Bio-CBCT-est matched well with that manually obtained from 4D-CT reference images. CONCLUSIONS: Bio-CBCT-est substantially improves the accuracy of 4D liver tumor localization via cone-beam projections and a biomechanical model.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen
14.
PLoS One ; 13(5): e0198065, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29847586

RESUMEN

Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol is wide-ranging and not limited to the orthotopic prostate tumor study presented in the study.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Animales , Procesamiento de Imagen Asistido por Computador , Masculino , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador , Ratas
15.
Pract Radiat Oncol ; 8(3): e167-e174, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29452869

RESUMEN

PURPOSE: Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy. METHODS AND MATERIALS: We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed. RESULTS: Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy. CONCLUSIONS: Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Impresión Tridimensional/instrumentación , Siliconas/uso terapéutico , Femenino , Neoplasias de Cabeza y Cuello/patología , Humanos , Dosificación Radioterapéutica , Siliconas/farmacología
16.
Phys Med Biol ; 63(5): 055004, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29405123

RESUMEN

Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects' diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.


Asunto(s)
Neoplasias de la Mama/radioterapia , Mama/efectos de la radiación , Tomografía Computarizada de Haz Cónico/métodos , Posicionamiento del Paciente , Fantasmas de Imagen , Ultrasonografía Mamaria/métodos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional/métodos , Posición Prona , Prueba de Estudio Conceptual
17.
J Appl Clin Med Phys ; 16(4): 306-310, 2015 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-26218992

RESUMEN

Geometric or mechanical accuracy of kV and MV imaging systems of two Varian TrueBeam linacs have been monitored by two geomertirc calibration systems, Varian IsoCal geometric calibration system and home-developed gQA system. Results of both systems are cross-checked and the long-term geometric stabilities of linacs are evaluated. Two geometric calibration methodologies have been used to assess kV and MV imaging systems and their coincidence periodically on two TrueBeam linacs for about one year. Both systems analyze kV or MV projection images of special designed phantoms to retrieve geometric parameters of the imaging systems. The isocenters ­ laser isocenter and centers of rotations of kV imager and EPID ­ are then calculated, based on results of multiple projections from different angles. Long-term calibration results from both systems are compared for cross-checking. There are 24 sessions of side-by-side calibrations performed by both systems on two TrueBeam linacs. All the disagreements of isocenters between two calibrations systems are less than 1 mm with ± 0.1 mm SD. Most of the large disagreements occurred in vertical direction (AP direction), with an averaged disagreement of 0.45 mm. The average disagreements of isocenters are 0.09 mm in other directions. Additional to long-term calibration monitoring, for the accuracy test, special tests were performed by misaligning QA phantoms on purpose (5 mm away from setup isocenter in AP, SI, and lateral directions) to test the liability performance of both systems with the known deviations. The errors are within 0.5 mm. Both geometric calibration systems, IsoCal and gQA, are capable of detecting geometric deviations of kV and MV imaging systems of linacs. The long-term evaluation also shows that the deviations of geometric parameters and the geometric accuracies of both linacs are small and very consistent during the one-year study period.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Aceleradores de Partículas/normas , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/métodos , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Calibración , Humanos , Aceleradores de Partículas/instrumentación , Programas Informáticos
18.
J Appl Clin Med Phys ; 16(3): 5200, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103480

RESUMEN

In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, global image intensity discrepancies exist between DRRs and projections due to their different image orientations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported to match imperfectly matched projection images and DRRs. The kV projection images were matched with different DRRs in two steps. Preprocessing was performed in advance to generate two sets of DRRs. The tumors were removed from the planning 3D CT for a single phase of planning 4D CT images using planning contours of tumors. DRRs of background and DRRs of tumors were generated separately for every projection angle. The first step was to match projection images with DRRs of background signals. This method divided global images into a matrix of small tiles and similarities were evaluated by calculating normalized cross-correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) was automatically optimized to keep the tumor within a single projection tile that had a bad matching with the corresponding DRR tile. A pixel-based linear transformation was determined by linear interpolations of tile transformation results obtained during tile matching. The background DRRs were transformed to the projection image level and subtracted from it. The resulting subtracted image now contained only the tumor. The second step was to register DRRs of tumors to the subtracted image to locate the tumor. This method was successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (BrainLAB) for dynamic tumor tracking on phantom studies. Radiation opaque markers were implanted and used as ground truth for tumor positions. Although other organs and bony structures introduced strong signals superimposed on tumors at some angles, this method accurately located tumors on every projection over 12 gantry angles. The maximum error was less than 2.2 mm, while the total average error was less than 0.9mm. This algorithm was capable of detecting tumors without markers, despite strong background signals.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Técnica de Sustracción , Marcadores Fiduciales , Humanos , Aumento de la Imagen/métodos , Neoplasias Pulmonares/radioterapia , Radioterapia Guiada por Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Phys Med Biol ; 60(1): 101-16, 2015 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-25479095

RESUMEN

The purpose of this work is to develop an automated landmark-guided deformable image registration (LDIR) algorithm between the planning CT and daily cone-beam CT (CBCT) with low image quality. This method uses an automated landmark generation algorithm in conjunction with a local small volume gradient matching search engine to map corresponding landmarks between the CBCT and the planning CT. The landmarks act as stabilizing control points in the following Demons deformable image registration. LDIR is implemented on graphics processing units (GPUs) for parallel computation to achieve ultra fast calculation. The accuracy of the LDIR algorithm has been evaluated on a synthetic case in the presence of different noise levels and data of six head and neck cancer patients. The results indicate that LDIR performed better than rigid registration, Demons, and intensity corrected Demons for all similarity metrics used. In conclusion, LDIR achieves high accuracy in the presence of multimodality intensity mismatch and CBCT noise contamination, while simultaneously preserving high computational efficiency.


Asunto(s)
Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Humanos , Intensificación de Imagen Radiográfica
20.
Artículo en Inglés | MEDLINE | ID: mdl-22255426

RESUMEN

This paper describes an approach to improve the contrast and signal to noise ratio on ultrasound images. Images with sub-pixel lateral displacements were re-sampled using a hexagonal grid, registered and compounded. The resultant image was filtered using a hexagonal adaptive masking filter. This approach was evaluated with simulated images and real images from a breast phantom. The results show total improvements in signal to noise ratio of up to 313% in simulated images, and 182% in phantom images. Contrast to noise ratio was improved by 286% in simulated images and 56% in phantom images.


Asunto(s)
Ultrasonografía , Humanos , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...