Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Adv ; 10(42): eadq9575, 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39423259

RESUMEN

Wearable haptics serve as an enhanced media to connect humans and VR/robots. The inevitable sweating issue in all wearables creates a bottleneck for wearable haptics, as the sweat/moisture accumulated in the skin/device interface can substantially affect feedback accuracy, comfortability, and create hygienic problems. Nowadays, wearable haptics typically gain performance at the cost of sacrificing the breathability, comfort, and biocompatibility. Here, we developed a fully integrated breathable haptic textile (FIBHT) to solve these trade-off issues, where the FIBHT exhibits high-level integration of 128 pixels over the palm, great stretchability of 400%, and superior permeability of over 657 g/m2/day (moisture) and 40 mm/s (air). It is a stand-alone haptic system totally composed of stretchable, breathable, and bioadhesive materials, which empowers it with precise, sweating/movement-insensitive and dynamic feedback, and makes FIBHT powerful for virtual touching in broad scenarios.


Asunto(s)
Textiles , Dispositivos Electrónicos Vestibles , Humanos , Tacto/fisiología
2.
Nat Commun ; 15(1): 7800, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39242511

RESUMEN

Dynamic tracking of spinal instrumentation could facilitate real-time evaluation of hardware integrity and in so doing alert patients/clinicians of potential failure(s). Critically, no method yet exists to continually monitor the integrity of spinal hardware and by proxy the process of spinal arthrodesis; as such hardware failures are often not appreciated until clinical symptoms manifest. Accordingly, herein, we report on the development and engineering of a bio-adhesive metal detector array (BioMDA), a potential wearable solution for real-time, non-invasive positional analyses of osseous implants within the spine. The electromagnetic coupling mechanism and intimate interfacial adhesion enable the precise sensing of the metallic implants position without the use of radiation. The customized decoupling models developed facilitate the precise determination of the horizontal and vertical positions of the implants with incredible levels of accuracy (e.g., <0.5 mm). These data support the potential use of BioMDA in real-time/dynamic postoperative monitoring of spinal implants.


Asunto(s)
Metales , Prótesis e Implantes , Columna Vertebral , Dispositivos Electrónicos Vestibles , Humanos , Columna Vertebral/cirugía , Metales/química , Adhesivos , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos
3.
Biosens Bioelectron ; 263: 116597, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39059179

RESUMEN

Traditional temporary cardiac pacemakers (TCPs), which employ transcutaneous leads and external wired power systems are battery-dependent and generally non-absorbable with rigidity, thereby necessitating surgical retrieval after therapy and resulting in potentially severe complications. Wireless and bioresorbable transient pacemakers have, hence, emerged recently, though hitting a bottleneck of unfavorable tissue-device bonding interface subject to mismatched mechanical modulus, low adhesive strength, inferior electrical performances, and infection risks. Here, to address such crux, we develop a multifunctional interface hydrogel (MIH) with superior electrical performance to facilitate efficient electrical exchange, comparable mechanical strength to natural heart tissue, robust adhesion property to enable stable device-tissue fixation (tensile strength: ∼30 kPa, shear strength of ∼30 kPa, and peel-off strength: ∼85 kPa), and good bactericidal effect to suppress bacterial growth. Through delicate integration of this versatile MIH with a leadless, battery-free, wireless, and transient pacemaker, the entire system exhibits stable and conformal adhesion to the beating heart while enabling precise and constant electrical stimulation to modulate the cardiac rhythm. It is envisioned that this versatile MIH and the proposed integration framework will have immense potential in overcoming key limitations of traditional TCPs, and may inspire the design of novel bioelectronic-tissue interfaces for next-generation implantable medical devices.


Asunto(s)
Hidrogeles , Marcapaso Artificial , Tecnología Inalámbrica , Hidrogeles/química , Animales , Humanos , Técnicas Biosensibles/instrumentación , Diseño de Equipo , Adhesivos/química
4.
Nature ; 628(8006): 84-92, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38538792

RESUMEN

Wearable electronics with great breathability enable a comfortable wearing experience and facilitate continuous biosignal monitoring over extended periods1-3. However, current research on permeable electronics is predominantly at the stage of electrode and substrate development, which is far behind practical applications with comprehensive integration with diverse electronic components (for example, circuitry, electronics, encapsulation)4-8. Achieving permeability and multifunctionality in a singular, integrated wearable electronic system remains a formidable challenge. Here we present a general strategy for integrated moisture-permeable wearable electronics based on three-dimensional liquid diode (3D LD) configurations. By constructing spatially heterogeneous wettability, the 3D LD unidirectionally self-pumps the sweat from the skin to the outlet at a maximum flow rate of 11.6 ml cm-2 min-1, 4,000 times greater than the physiological sweat rate during exercise, presenting exceptional skin-friendliness, user comfort and stable signal-reading behaviour even under sweating conditions. A detachable design incorporating a replaceable vapour/sweat-discharging substrate enables the reuse of soft circuitry/electronics, increasing its sustainability and cost-effectiveness. We demonstrated this fundamental technology in both advanced skin-integrated electronics and textile-integrated electronics, highlighting its potential for scalable, user-friendly wearable devices.


Asunto(s)
Electrónica , Dispositivos Electrónicos Vestibles , Piel , Textiles , Electrodos
5.
Comput Biol Med ; 146: 105582, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35588678

RESUMEN

More than 422 million people worldwide suffered from diabetes mellitus (DM) in 2021. Diabetic foot is one the most critical complications resultant of DM. Foot ulceration and infection are frequently arisen, which are associated with changes in the mechanical properties of the plantar soft tissues, peripheral arterial disease, and sensory neuropathy. Diabetic insoles are currently the mainstay in reducing the risk of foot ulcers by reducing the magnitude of the pressure on the plantar Here, we propose a novel pressure relieving heel pad based on a circular auxetic re-entrant honeycomb structure by using three-dimensional (3D) printing technology to minimize the pressure on the heel, thus reducing the occurrence of foot ulcers. Finite element models (FEMs) are developed to evaluate the structural changes of the developed circular auxetic structure upon exertion of compressive forces. Moreover, the effects of the internal angle of the re-entrant structure on the peak contact force and the mean pressure acting on the heel as well as the contact area between the heel and the pads are investigated through a finite element analysis (FEA). Based on the result from the validated FEMs, the proposed heel pad with an auxetic structure demonstrates a distinct reduction in the peak contact force (∼10%) and the mean pressure (∼14%) in comparison to a conventional diabetic insole (PU foam). The characterized result of the designed circular auxetic structure not only provides new insights into diabetic foot protection, but also the design and development of various impact resistance products.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Neuropatías Diabéticas , Diabetes Mellitus/terapia , Pie Diabético/terapia , Análisis de Elementos Finitos , Talón , Humanos , Impresión Tridimensional , Zapatos
6.
PLoS One ; 16(4): e0250428, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33891633

RESUMEN

In this article, the impact of postural variations on hand anthropometry and distribution of skin strain ratios has been investigated. The literature suggests the glove fit directly affects hand functions. However, gloves currently manufactured based on a static posture failed to provide optimum fit. Workers often do not wear protective gloves due to discomfort caused by improper design, which increases the risk of hand injury. Full-color three-dimensional scans of the hands are captured with thirty healthy subjects (20 females, 10 males) to analyze the hand measurements and skin deformation with various postures. 42 of the 57 hand dimensions were found to have significant differences (p >0.05) related to hand posture. The skin strain ratios further suggest that the slant of the web space, dorsal-length and surface area should be increased, while the angles of the web space and length of the palm reduced to advance glove patterns. This research contributes to constructing gloves with optimum fit, performance, and comfort. Results show that in consideration of hand postures, the angle of the slant of web space between digits 2 and 5 and the finger length on the dorsal side should be increased, whilst the finger length on the palm side should be reduced in glove pattern design. Gloves currently constructed based on a splayed posture cannot provide a good fit. Consideration should be given to hand measurements in dynamic postures.


Asunto(s)
Guantes Protectores , Mano/anatomía & histología , Adolescente , Adulto , Antropometría , Femenino , Fuerza de la Mano , Humanos , Masculino , Postura , Adulto Joven
7.
Int J Bioprint ; 7(1): 327, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33585716

RESUMEN

The treatment of hypertrophic scars (HSs) is considered to be the most challenging task in wound rehabilitation. Conventional silicone sheet therapy has a positive effect on the healing process of HSs. However, the dimensions of the silicone sheet are typically larger than those of the HS itself which may negatively impact the healthy skin that surrounds the HS. Furthermore, the debonding and displacement of the silicone sheet from the skin are critical problems that affect treatment compliance. Herein, we propose a bespoke HS treatment design that integrates pressure sleeve with a silicone sheet and use of silicone gel using a workflow of three-dimensional (3D) printing, 3D scanning and computer-aided design, and manufacturing software. A finite element analysis (FEA) is used to optimize the control of the pressure distribution and investigate the effects of the silicone elastomer. The result shows that the silicone elastomer increases the amount of exerted pressure on the HS and minimizes unnecessary pressure to other parts of the wrist. Based on this treatment design, a silicone elastomer that perfectly conforms to an HS is printed and attached onto a customized pressure sleeve. Most importantly, unlimited scar treating gel can be applied as the means to optimize treatment of HSs while the silicone sheet is firmly affixed and secured by the pressure sleeve.

8.
Int J Bioprint ; 6(2): 262, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32782991

RESUMEN

Hypertrophic scars (HS) are considered to be the greatest unmet challenge in wound and burn rehabilitation. The most common treatment for HS is pressure therapy, but pressure garments may not be able to exert adequate pressure onto HS due to the complexity of the human body. However, the development of three-dimensional (3D) scanning and direct digital manufacturing technologies has facilitated the customized placement of additively manufactured silicone gel onto fabric as a component of the pressure therapy garment. This study provides an introduction on a novel and customized fabrication approach to treat HS and discusses the mechanical properties of 3D printed fabric reinforced with a silicone composite. For further demonstration of the suggested HS therapy with customized silicone insert, silicone inserts for the finger webs and HS were additively manufactured onto the fabric. Through the pressure evaluation by Pliance X system, it proved that silicone insert increases the pressure exerted to the HS. Moreover, the mechanical properties of the additively manufactured fabric silicone composites were characterized. The findings suggest that as compared with single viscosity print materials, the adhesive force of the additively manufactured silicone and fabric showed a remarkable improvement of 600% when print materials with different viscosities were applied onto elevated fabric.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...