Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Cancers (Basel) ; 16(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38791869

RESUMEN

This study uses Monte Carlo simulation and experimental measurements to develop a predictive model for estimating the external dose rate associated with permanent radioactive source implantation in prostate cancer patients. The objective is to estimate the accuracy of the patient's external dose rate measurement. First, I-125 radioactive sources were implanted into Mylar window water phantoms to simulate the permanent implantation of these sources in patients. Water phantom experimental measurement was combined with Monte Carlo simulation to develop predictive equations, whose performance was verified against external clinical data. The model's accuracy in predicting the external dose rate in patients with permanently implanted I-125 radioactive sources was high (R2 = 0.999). A comparative analysis of the experimental measurements and the Monte Carlo simulations revealed that the maximum discrepancy between the measured and calculated values for the water phantom was less than 5.00%. The model is practical for radiation safety assessments, enabling the evaluation of radiation exposure risks to individuals around patients with permanently implanted I-125 radioactive sources.

2.
Med Phys ; 50(12): 8057-8062, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37655886

RESUMEN

PURPOSE: Transmission-target x-ray tubes generate more x-rays than reflection thick-target x-ray tubes. A transmission x-ray tube combined with radiosensitizers has a better radiation enhancement effect. This study investigated the feasibility of using a transmission x-ray tube with radiosensitizers in clinical radiotherapy and its effect on radiation dose enhancement. METHODS: This study used MCNP6.2 to simulate the model of a transmission x-ray tube and Co-60 beam.   The radiation enhancement effect of radiosensitizers was examined with iodine-127 (I-127), radioiodinated iododeoxyuridine (IUdR), and gold nanoparticles (GNPs). RESULTS: The study results showed that the dose enhancement factor (DEF) of the transmission x-ray tube with GNPs was 10.27, which was higher than that of I-127 (6.46) and IUdR (3.08). The DEF of the Co-60 beam with GNPs, I-127, and IUdR was 1.23, 1.19, and 1.2, respectively. The Auger electron flux of the transmission x-ray tube with GNPs was 1.19E+05 particles/cm2 . CONCLUSIONS: This study found that a transmission x-ray tube with appropriate radiosensitizers could produce a high rate of Auger electrons to fulfill the radiation enhancement effect, and this procedure has the potential to become a radiotherapy modality.


Asunto(s)
Nanopartículas del Metal , Fármacos Sensibilizantes a Radiaciones , Idoxuridina , Rayos X , Método de Montecarlo , Oro , Nanopartículas del Metal/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...