Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 16(16): 2021-2030, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480892

RESUMEN

BACKGROUND: Preprocedural computed tomography (CT) workup with assessment of virtual transcatheter heart valve-to-coronary ostia (VTC) distance and transcatheter heart valve-to-sinus (VTS) distances is recommended to assess the risk of coronary obstruction following valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors sought to investigate the agreement of predicted VTC and VTS distances and observed post-TAVR anatomy on CT and their relationship with transcatheter heart valve (THV) expansion and deployment conditions. METHODS: Fifty-one patients who underwent a balloon-expandable ViV procedure were included in this study. The expansion of the THV stent frame was evaluated at 4 levels: THV inflow, surgical heart valve (SHV) sewing ring, SHV outflow, and THV outflow. Assessment of the VTC/VTS distances was performed on the pre-TAVR CT, and THV-to-coronary ostia and THV-to-sinus distances were assessed on the post-TAVR CT. RESULTS: Following the ViV procedure, the THV stent frame flared toward the outflow but was generally underexpanded at all levels, particularly at the SHV sewing ring level. Postdilatation impacted the extent of THV expansion, resulting in greater expansion than nominal balloon filling at all 4 THV levels (P < 0.001). Observed THV-to-coronary ostia distances were systematically larger than predicted by the VTC distance (mean difference 1.25 ±1.28 mm) in patients with nominal balloon filling but systematically smaller in case of postdilatation (mean difference -0.45 ± 0.52 mm). A similar relationship was observed between VTS and THV-to-sinus distance measurements. CONCLUSIONS: With nominal balloon filling, VTC and VTS distances underestimate postprocedural distances due to THV frame underexpansion. However, postdilatation may lead to distances smaller than predicted due to THV overexpansion at the outflow level.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Corazón , Catéteres , Tomografía Computarizada por Rayos X
2.
JACC Cardiovasc Interv ; 15(23): 2387-2395, 2022 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-36402718

RESUMEN

BACKGROUND: The cusp-overlap (CO) technique has recently been advocated and is being increasingly adopted for self-expandable transcatheter heart valve (THV) implantation. OBJECTIVES: The aim of this study was to evaluate the feasibility, implantation depth, and outcomes of the CO technique for the balloon-expandable SAPIEN 3 THV. METHODS: The CO technique was used in consecutive patients undergoing balloon-expandable THV implantation at one center between April 2021 and March 2022. Optimal fluoroscopic angles were determined from preprocedural computed tomography and confirmed on predeployment angiography. The THV radiolucent line was positioned 2 to 4 mm below the noncoronary cusp in the CO view, and positioning was confirmed in the 3-cusp view. Postdeployment THV implantation depth was assessed in both views. One-month outcomes were assessed using Valve Academic Research Consortium 3 criteria. RESULTS: Among 137 patients eligible for the CO technique, the CO view was not used because of unfavorable ergonomics in 27 patients (26.5%) and hemodynamic instability in 8 patients (7.8%). Among 102 patients, the mean age was 81.1 ± 6.6 years, the mean Society of Thoracic Surgeons score was 3.3% ± 2.2%, and 64.7% were men. The mean measured THV implantation depth was 3.0 ± 1.4 mm in the CO view and 2.5 ± 1.4 mm in the 3-cusp view. At 1-month follow-up, 1 patient (1.0%) had died, 1 (1.0%) had had a stroke, and 7 (6.8%) had undergone permanent pacemaker implantation. CONCLUSIONS: The CO technique is feasible and safe and may facilitate more accurate balloon-expandable THV positioning, especially when deep implantation needs to be avoided. Further studies are required to explore potential reduction in atrioventricular conduction block, pacemakers, or paravalvular regurgitation.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 79(14): 1340-1351, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35393014

RESUMEN

BACKGROUND: Transcatheter heart valve (THV) dysfunction with an elevated gradient or paravalvular leak (PVL) may be documented late after THV implantation. Medical management, paravalvular plugs, redo THV replacement, or surgical valve replacement may be considered. However, late balloon dilatation is rarely utilized because of concerns about safety or lack of efficacy. OBJECTIVES: We aimed to evaluate the safety and efficacy of late dilatation in the management of THV dysfunction. METHODS: All patients who underwent late dilatation for symptomatic THV dysfunction at 2 institutions between 2016 and 2021 were identified. Baseline, procedural characteristics, and clinical and echocardiographic outcomes were documented. THV frame expansion was assessed by multislice computed tomography before and after late dilatation. RESULTS: Late dilatation was performed in 30 patients a median of 4.6 months (IQR: 2.3-11.0 months) after THV implantation in the aortic (n = 25; 83.3%), mitral (n = 2; 6.7%), tricuspid (n = 2; 6.7%) and pulmonary (n = 1; 3.3%) position. THV underexpansion was documented at baseline, and frame expansion substantially improved after late dilatation. The mean transvalvular gradient fell in all patients. For aortic THVs specifically, mean transaortic gradient fell from 25.4 ± 13.9 mm Hg to 10.8 ± 4.1 mm Hg; P < 0.001. PVL was reduced to ≤mild in all 11 patients with a previous >mild PVL. Embolic events, stroke, annular injury, and bioprosthetic leaflet injury were not observed. Symptomatic benefit was durable at 19.6 months (IQR: 14.8-36.1 months) follow-up. CONCLUSIONS: Balloon dilatation late after THV implantation appears feasible and safe in appropriately selected patients and may result in THV frame expansion resulting in improvements in hemodynamic performance and PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...