Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Sci Rep ; 13(1): 10012, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37340077

RESUMEN

Our objective was to evaluate and compare the diagnostic performance of post-contrast 3D compressed-sensing volume-interpolated breath-hold examination (CS-VIBE) and 3D T1 magnetization-prepared rapid-acquisition gradient-echo (MPRAGE) in detecting intracranial metastasis. Additionally, we analyzed and compared the image quality between the two. We enrolled 164 cancer patients who underwent contrast-enhanced brain MRI. Two neuroradiologists independently reviewed all the images. The signal-to-noise ratio (SNR), contrast-to noise ratio (CNR) were compared between two sequences. For patients with intracranial metastasis, we measured enhancement degree and CNRlesion/parenchyma of the lesion. The overall image quality, motion artifact, gray-white matter discrimination and enhancing lesion conspicuity were analyzed. Both MPRAGE and CS-VIBE showed similar performance in diagnosing intracranial metastasis. Overall image quality of CS-VIBE was better with less motion artifact; however conventional MPRAGE was superior in enhancing lesion conspicuity. Overall, the SNR and CNR of conventional MPRAGE were higher than those of CS-VIBE. For 30 enhancing intracranial metastatic lesions, MPRAGE showed a lower CNR (p = 0.02) and contrast ratio (p = 0.03). MPRAGE and CS-VIBE were preferred in 11.6 and 13.4% of cases, respectively. In comparison with conventional MPRAGE, CS-VIBE achieved comparable image quality and visualization, with the scan time being half of that of MPRAGE.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Estudios de Factibilidad , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Contencion de la Respiración , Encéfalo/diagnóstico por imagen , Artefactos , Aumento de la Imagen/métodos , Medios de Contraste
2.
PLoS One ; 18(5): e0285089, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37146026

RESUMEN

PURPOSE: We aimed to validate the diagnostic performance of accelerated post-contrast magnetization-prepared rapid gradient-echo (MPRAGE) using wave-controlled aliasing in parallel imaging (Wave-CAIPI) for enhancing intracranial lesions, compared with conventional MPRAGE. METHODS: A total of 233 consecutive patients who underwent post-contrast Wave-CAIPI and conventional MPRAGE (scan time: 2 min 39 s vs. 4 min 30 s) were retrospectively evaluated. Two radiologists independently assessed whole images for the presence and diagnosis of enhancing lesions. The diagnostic performance for non-enhancing lesions, quantitative parameters (diameter of enhancing lesions, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and contrast rate), qualitative parameters (grey-white matter differentiation and conspicuity of enhancing lesions), and image qualities (overall image quality and motion artifacts) were also surveyed. The weighted kappa and percent agreement were used to evaluate the diagnostic agreement between the two sequences. RESULTS: Wave-CAIPI MPRAGE achieved significantly high agreement for the detection (98.7%[460/466], κ = 0.965) and diagnosis (97.8%[455/466], κ = 0.955) of enhancing intracranial lesions with conventional MPRAGE in pooled analysis. Detection and diagnosis of non-enhancing lesions (97.6% and 96.9% agreement), and diameter of enhancing lesions (P>0.05) also demonstrated high agreements between two sequences. Although Wave-CAIPI MPRAGE show lower SNR (P<0.01) than conventional MRAGE, it fulfilled comparable CNR (P = 0.486) and higher contrast rate (P<0.01). The qualitative parameters show similar value (P>0.05). The overall image quality was slightly poor, however, motion artifacts were better in Wave-CAIPI MPRAGE (both P = 0.005). CONCLUSION: Wave-CAIPI MPRAGE provides reliable diagnostic performance for enhancing intracranial lesions within half of the scan time compared with conventional MPRAGE.


Asunto(s)
Imagen por Resonancia Magnética , Sustancia Blanca , Humanos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Sustancia Gris , Relación Señal-Ruido , Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos
3.
Sci Rep ; 12(1): 21930, 2022 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-36536040

RESUMEN

We aimed to evaluate the agreement in the diagnosis of intracranial lesions between conventional pre-contrast 3D T1 magnetization-prepared rapid gradient echo (MPRAGE) and wave-CAIPI (wave-controlled aliasing in parallel imaging) MPRAGE. Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 149 consecutive patients who had undergone brain MR with both conventional MPRAGE (scan time: 5 min 42 s) and wave-CAIPI MPRAGE (scan time: 2 min 44 s) from February to June 2018. All images were independently reviewed by two radiologists for the diagnosis of intracranial lesion and scored image quality using visual analysis. One technician measured signal-to-noise ratio. The agreement for diagnosis of intracranial lesion was calculated, and the intra- and interobserver agreements were analyzed by using kappa value. For the diagnosis of intracranial lesion, the conventional and wave-CAIPI MPRAGE demonstrated 99.7% of agreement (297 of 298) in the pooled analysis with very good agreement (k = 0.994). Intra- and inter-observer agreement showed very good (k > 0.9 in all) and good (k > 0.75) agreement, respectively. In the quantitative analysis, the signal-to-noise ratio had no difference (P > 0.05 for all). The overall image quality was poorer in images of wave-CAIPI MPRAGE (P < 0.001), but motion artifact had no difference between two sequences (P = 0.06). Compared to conventional MPRAGE, pre-contrast 3D T1 wave-CAIPI MPRAGE achieved higher agreement for the diagnosis of intracranial lesions and reduced the scan time by approximately 50%.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Aumento de la Imagen/métodos
4.
Eur Radiol ; 32(1): 223-233, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34156555

RESUMEN

OBJECTIVE: We aimed to compare the diagnostic performance of post-contrast 3D compressed sensing volume-interpolated breath-hold examination (CS-VIBE) and 3D T1 magnetization-prepared rapid-acquisition gradient-echo (MPRAGE) in detecting facial neuritis. MATERIALS AND METHODS: Between February 2019 and September 2019, 60 patients (30 facial palsy patients and 30 controls) who underwent contrast-enhanced cranial nerve MRI with both conventional MPRAGE and CS-VIBE (scan time: 6 min 8 s vs. 2 min 48 s) were included in this retrospective study. All images were independently reviewed by three radiologists for the presence of facial neuritis. In patients with facial palsy, signal-to-noise ratio (SNR) of the pons, enhancement degree and contrast-to-noise ratio (CNRnerve-CSF) of the facial nerve were measured. The overall image quality, artifacts, and facial nerve discrimination were analyzed. The sensitivity and specificity of both sequences were calculated with the clinical diagnosis as a reference. RESULTS: CS-VIBE had comparable performance in the detection of facial neuritis to that of MPRAGE (sensitivity and specificity, 97.8% and 99.4% vs. 100.0% and 99.4% in pooled analysis; 97.8% and 98.9% vs. 100.0% and 98.9% in patents with facial palsy, p value > 0.05 for all). CS-VIBE showed significantly lower SNR (p value < 0.001 for all), but significantly higher CNRnerve-CSF (p value < 0.05 for all) than MPRAGE. CS-VIBE also performed better in the overall image quality, artifacts, and facial nerve discrimination than MPRAGE (p value < 0.001 for all). CONCLUSION: CS-VIBE achieved comparable diagnostic performance for facial neuritis compared to the conventional MPRAGE, with the scan time being half of that of MPRAGE. KEY POINTS: • Post-contrast 3D CS-VIBE MRI is a reliable method for the diagnosis of facial neuritis. • CS-VIBE reduces the scan time of cranial nerve MRI by more than half compared to conventional T1-weighted image. • CS-VIBE had better performance in contrast-to-noise ratio and favorable image quality compared with conventional T1-weighted image.


Asunto(s)
Enfermedades del Nervio Facial , Aumento de la Imagen , Artefactos , Medios de Contraste , Nervio Facial/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Estudios Retrospectivos
5.
Sci Rep ; 11(1): 13296, 2021 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-34168260

RESUMEN

We aimed to compare accelerated post-contrast magnetization-prepared rapid gradient-echo (MPRAGE) using wave-controlled aliasing in parallel imaging (wave-CAIPI) with conventional MPRAGE as a reliable method to diagnose intracranial lesions in pediatric patients. A total of 23 consecutive pediatric patients who underwent post-contrast wave-CAIPI and conventional MPRAGE (scan time: 2 min 39 s vs. 5 min 46 s) were retrospectively evaluated. Two radiologists independently assessed each image for the presence of intracranial lesions. Quantitative [contrast-to-noise ratio (CNR), contrast rate (CR), and signal-to-noise ratio (SNR)] and qualitative parameters (overall image quality, gray-white matter differentiation, demarcation of basal ganglia and sulci, and motion artifacts) were also surveyed. Wave-CAIPI MPRAGE and conventional MPRAGE detected enhancing and non-enhancing intracranial lesions with 100% agreement. Although wave-CAIPI MPRAGE had a lower SNR (all p < 0.05) and overall image quality (overall analysis, p = 0.02) compared to conventional MPRAGE, other quantitative (CNR and CR) and qualitative parameters (gray-white differentiation, demarcation of basal ganglia and sulci, and motion artifacts) were comparable in the pooled analysis and between both observers (all p > 0.05). Wave-CAIPI MPRAGE was a reliable method for diagnosing intracranial lesions in pediatric patients as conventional MPRAGE at half the scan time.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Niño , Preescolar , Humanos , Lactante , Neuroimagen/métodos
6.
J Clin Neurol ; 17(2): 307-316, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33835753

RESUMEN

BACKGROUND AND PURPOSE: We aimed to determine the intermethod reproducibility between the commercial software Inbrain (MIDAS IT) and the established research-purpose method FreeSurfer, as well as the effect of MRI resolution and the pathological condition of subjects on their intermethod reproducibility. METHODS: This study included 45 healthy volunteers and 85 patients with mild cognitive impairment (MCI). In 43 of the 85 patients with MCI, three-dimensional, T1-weighted MRI data were obtained at an in-plane resolution of 1.2 mm. The data of the remaining 42 patients with MCI and the healthy volunteers were obtained at an in-plane resolution of 1.0 mm. The within-subject coefficient of variation (CoV), intraclass correlation coefficient (ICC), and effect size were calculated, and means were compared using paired t-tests. The parameters obtained at 1.0-mm and 1.2-mm resolutions in patients with MCI were compared to evaluate the effect of the in-plane resolution on the intermethod reproducibility. The parameters obtained at a 1.0-mm in-plane resolution in patients with MCI and healthy volunteers were used to analyze the effect of subject condition on intermethod reproducibility. RESULTS: Overall the two methods showed excellent reproducibility across all regions of the brain (CoV=0.5-3.9, ICC=0.93 to >0.99). In the subgroup of healthy volunteers, the intermethod reliability was only good in some regions (frontal, temporal, cingulate, and insular). The intermethod reproducibility was better in the 1.0-mm group than the 1.2-mm group in all regions other than the nucleus accumbens. CONCLUSIONS: Inbrain and FreeSurfer showed good-to-excellent intermethod reproducibility for volumetric measurements. Nevertheless, some noticeable differences were found based on subject condition, image resolution, and brain region.

7.
Yonsei Med J ; 62(3): 255-261, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33635016

RESUMEN

PURPOSE: This study aimed to examine the inter-method reliability and volumetric differences between NeuroQuant (NQ) and Freesurfer (FS) using T1 volume imaging sequence with different slice thicknesses in patients with mild cognitive impairment (MCI). MATERIALS AND METHODS: This retrospective study enrolled 80 patients diagnosed with MCI at our memory clinic. NQ and FS were used for volumetric analysis of three-dimensional T1-weighted images with slice thickness of 1 and 1.2 mm. Inter-method reliability was measured with Pearson correlation coefficient (r), intraclass correlation coefficient (ICC), and effect size (ES). RESULTS: Overall, NQ volumes were larger than FS volumes in several locations: whole brain (0.78%), cortical gray matter (5.34%), and white matter (2.68%). Volume measures by NQ and FS showed good-to-excellent ICCs with both 1 and 1.2 mm slice thickness (ICC=0.75-0.97, ES=-1.0-0.73 vs. ICC=0.78-0.96, ES=-0.9-0.77, respectively), except for putamen, pallidum, thalamus, and total intracranial volumes. The ICCs in all locations, except the putamen and cerebellum, were slightly higher with a slice thickness of 1 mm compared to those of 1.2 mm. CONCLUSION: Inter-method reliability between NQ and FS was good-to-excellent in most regions with improvement with a 1-mm slice thickness. This finding indicates that the potential effects of slice thickness should be considered when performing volumetric measurements for cognitive impairment.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/patología , Disfunción Cognitiva/diagnóstico por imagen , Disfunción Cognitiva/patología , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Automatización , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
8.
Taehan Yongsang Uihakhoe Chi ; 82(5): 1124-1139, 2021 Sep.
Artículo en Coreano | MEDLINE | ID: mdl-36238415

RESUMEN

The objective assessment of atrophy and the measurement of brain volume is important in the early diagnosis of dementia and neurodegenerative diseases. Recently, several MR-based volumetry software have been developed. For their clinical application, several issues arise, including the standardization of image acquisition and their validation of software. Additionally, it is important to highlight the diagnostic performance of the volumetry software based on expert opinions. We instituted a task force within the Korean Society of Neuroradiology to develop guidelines for the clinical use of MR-based brain volumetry software. In this review, we introduce the commercially available software and compare their diagnostic performances. We suggest the need for a standard protocol for image acquisition, the validation of the software, and evaluations of the limitations of the software related to clinical practice. We present recommendations for the clinical applications of commercially available software for volumetry based on the expert opinions of the Korean Society of Neuroradiology.

9.
Taehan Yongsang Uihakhoe Chi ; 82(5): 1281-1286, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36238416

RESUMEN

Brainstem infarction due to vertebrobasilar insufficiency is a rare initial presentation of systemic lupus erythematosus (SLE) patients and small-vessel dissection as the direct cause of infarction has not been reported. We report the case of a 20-year-old female with acute infarction on the right side of the pons due to a small artery (pontine perforator) dissection, identified on digital subtraction angiography and high-resolution vessel wall MRI (vwMRI). She was diagnosed with SLE based on the presence of neurologic disorders and relevant laboratory findings. The pontine perforator-dissecting aneurysm had occluded and the right distal vertebral artery had resolved on subsequent vwMRI. She had a modified Rankin Scale (mRS) score of 1 at discharge with mild symptom improvement, and exhibited no further aggravation of symptoms at 3 or 12 months, maintaining an mRS score of 1.

10.
Korean J Radiol ; 22(5): 751-758, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33289362

RESUMEN

OBJECTIVE: Preoperative differentiation between inverted papilloma (IP) and its malignant transformation to squamous cell carcinoma (IP-SCC) is critical for patient management. We aimed to determine the diagnostic accuracy of conventional imaging features and histogram parameters obtained from whole tumor apparent diffusion coefficient (ADC) values to predict IP-SCC in patients with IP, using decision tree analysis. MATERIALS AND METHODS: In this retrospective study, we analyzed data generated from the records of 180 consecutive patients with histopathologically diagnosed IP or IP-SCC who underwent head and neck magnetic resonance imaging, including diffusion-weighted imaging and 62 patients were included in the study. To obtain whole tumor ADC values, the region of interest was placed to cover the entire volume of the tumor. Classification and regression tree analyses were performed to determine the most significant predictors of IP-SCC among multiple covariates. The final tree was selected by cross-validation pruning based on minimal error. RESULTS: Of 62 patients with IP, 21 (34%) had IP-SCC. The decision tree analysis revealed that the loss of convoluted cerebriform pattern and the 20th percentile cutoff of ADC were the most significant predictors of IP-SCC. With these decision trees, the sensitivity, specificity, accuracy, and C-statistics were 86% (18 out of 21; 95% confidence interval [CI], 65-95%), 100% (41 out of 41; 95% CI, 91-100%), 95% (59 out of 61; 95% CI, 87-98%), and 0.966 (95% CI, 0.912-1.000), respectively. CONCLUSION: Decision tree analysis using conventional imaging features and histogram analysis of whole volume ADC could predict IP-SCC in patients with IP with high diagnostic accuracy.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Árboles de Decisión , Imagen de Difusión por Resonancia Magnética , Papiloma Invertido/diagnóstico , Adulto , Anciano , Área Bajo la Curva , Carcinoma de Células Escamosas/patología , Femenino , Cabeza/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Papiloma Invertido/patología , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
11.
Korean J Radiol ; 22(3): 405-414, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33236539

RESUMEN

OBJECTIVE: To compare two clinically available MR volumetry software, NeuroQuant® (NQ) and Inbrain® (IB), and examine the inter-method reliabilities and differences between them. MATERIALS AND METHODS: This study included 172 subjects (age range, 55-88 years; mean age, 71.2 years), comprising 45 normal healthy subjects, 85 patients with mild cognitive impairment, and 42 patients with Alzheimer's disease. Magnetic resonance imaging scans were analyzed with IB and NQ. Mean differences were compared with the paired t test. Inter-method reliability was evaluated with Pearson's correlation coefficients and intraclass correlation coefficients (ICCs). Effect sizes were also obtained to document the standardized mean differences. RESULTS: The paired t test showed significant volume differences in most regions except for the amygdala between the two methods. Nevertheless, inter-method measurements between IB and NQ showed good to excellent reliability (0.72 < r < 0.96, 0.83 < ICC < 0.98) except for the pallidum, which showed poor reliability (left: r = 0.03, ICC = 0.06; right: r = -0.05, ICC = -0.09). For the measurements of effect size, volume differences were large in most regions (0.05 < r < 6.15). The effect size was the largest in the pallidum and smallest in the cerebellum. CONCLUSION: Comparisons between IB and NQ showed significantly different volume measurements with large effect sizes. However, they showed good to excellent inter-method reliability in volumetric measurements for all brain regions, with the exception of the pallidum. Clinicians using these commercial software should take into consideration that different volume measurements could be obtained depending on the software used.


Asunto(s)
Enfermedad de Alzheimer/fisiopatología , Encéfalo/fisiología , Disfunción Cognitiva/fisiopatología , Programas Informáticos , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Estudios de Casos y Controles , Disfunción Cognitiva/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
12.
Jpn J Radiol ; 39(3): 273-282, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33030650

RESUMEN

PURPOSE: To explore the effect of transcatheter arterial embolization (TAE) in controlling intractable, nontraumatic bladder hemorrhage in cancer patients. MATERIALS AND METHODS: A literature review (PubMed and EMBASE), followed by a retrospective analysis of all cancer patients with intractable hematuria from bladder treated by TAE at our tertiary referral center. RESULTS: At our institution, 27 consecutive cancer patients who underwent TAE for refractory hematuria from bladder were identified. The systematic review included 13 studies published between 1981 and 2019. In our local cohort, 27 patients were treated with 100% technical success, clinical success in 88.9%, no major complications, and rebleeding rate within the first month of 7.4%. In the systematic review cohort of 201 patients, there was technical success in 99.0%, clinical success in 80.9%, major complications in 5.5%, and a rebleeding rate within the first month of 4.5%. Bilateral embolization was performed in 81.1%, and embolization levels were mostly anterior division of internal iliac artery (73.7%) and vesical artery (23.2%). CONCLUSION: TAE is effective and safe to control intractable hematuria from bladder origin in cancer patients after failure of conservative management, providing effective temporary hemostasis. For bladder hemorrhage unsuitable for surgery, TAE should be considered at an early stage. A literature review, followed by retrospective analysis of all patients with intractable hematuria from bladder treated by transcatheter arterial embolization at our tertiary referral center. Transcatheter arterial embolization is effective and safe to control intractable hematuria from bladder. The major complication rate and rebleeding within the first month are acceptable.


Asunto(s)
Embolización Terapéutica/métodos , Hematuria/etiología , Hematuria/terapia , Neoplasias/complicaciones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
13.
Eur Radiol ; 30(4): 2182-2190, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31953660

RESUMEN

OBJECTIVES: We aimed to evaluate the agreement in the detection of cerebral microbleeds (CMBs) between conventional susceptibility-weighted imaging (SWI) and fast SWI using wave-controlled aliasing in parallel imaging (CAIPI) acceleration. We also scrutinized the diagnostic agreement for intracranial lesions and compared the image quality between both sequences. METHODS: Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 181 consecutive patients who had undergone brain MRI with both conventional SWI (scan time, 251 s) and wave-CAIPI SWI (scan time, 113 s) from September 2017 to November 2017. All images were independently reviewed by two radiologists for the detection and counting of CMBs using the Microbleed Anatomical Rating Scale (MARS). One neuroradiologist diagnosed intracranial lesions and scored image quality using visual analysis. The agreement for detection of CMBs and intracranial lesions was calculated, and interobserver agreements were analyzed by using kappa and intraclass correlation. RESULTS: For detection of CMBs, both the conventional and wave-CAIPI SWI showed significantly high agreement of 100% for the presence of CMBs, and 94.5% using MARS. Wave-CAIPI SWI achieved more than 97% agreement of MARS when divided by anatomical locations, with excellent agreement. Interobserver agreements were also excellent. The diagnosis for intracranial lesions (33 lesions in 28 patients) demonstrated 100% agreement. The image quality of both sequences is not significantly different (p = 0.20). CONCLUSIONS: Wave-CAIPI SWI achieved high agreement for CMB detection and diagnosis of intracranial lesions compared to conventional SWI within half of the scan time. KEY POINTS: • Wave-CAIPI SWI achieves a diagnostic performance for the detection of cerebral microbleeds that is comparable to that of conventional SWI in half the scan time. • Interobserver agreement for the detection (presence vs. absence) and counting of cerebral microbleeds of wave-CAIPI SWI was excellent. • Wave-CAIPI SWI demonstrated a 100% agreement for the diagnosis of intracranial lesions and comparable image quality compared to conventional SWI.


Asunto(s)
Hemorragia Cerebral/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
14.
Yonsei Med J ; 60(11): 1112-1115, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31637895

RESUMEN

Direct puncture and embolization of the transverse sinus (TS) for treatment of dural arteriovenous fistula (DAVF) is typically performed with coils with or without glue. We report a case of DAVF at the left TS that was treated with Onyx embolization via direct puncture of the TS. A 75-year-old woman presented with tremor, festinating gait, and dysarthria. A left TS-DAVF with retrograde superior sagittal sinus and cortical venous reflux (Cognard type IIa+b) was identified on cerebral angiography, and both TSs were occluded with thrombi. We considered that achieving complete cure by transvenous embolization via the femoral vein or transarterial embolization via occipital feeders would be difficult. Thus, we performed a small craniotomy at the occipital bone to puncture the TS. The midportion of the TS was directly punctured with a 21-G microneedle under fluoroscopic guidance. We inserted a 5-F sheath into the TS. A microcatheter was then navigated into the affected sinus. Coils were placed through the microcatheter to support Onyx formation by reducing the pressure of shunting flow. Onyx embolization was performed with the same microcatheter. The DAVF was almost completely occluded except for the presence of minimal shunting flow to the proximal TS. After 1 week, time-of-flight magnetic resonance angiography showed complete resolution of DAVF. The patient showed resolved tremor and markedly improved mental status at 1-month follow up. Direct puncture and embolization of the TS using coils and Onyx is effective and feasible method for the treatment of DAVF when other approaches seem difficult.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central/cirugía , Embolización Terapéutica , Punciones , Senos Transversos/cirugía , Anciano , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Angiografía Cerebral , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Senos Transversos/diagnóstico por imagen , Resultado del Tratamiento
15.
Yonsei Med J ; 60(8): 774-781, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31347333

RESUMEN

PURPOSE: Cerebral small vessel disease (SVD) is known to be associated with ischemic stroke, intracerebral hemorrhage (ICH), and cognitive impairment. In this retrospective observational study, we explored SVD markers on MRI relevant to spontaneous ICH. MATERIALS AND METHODS: The ICH group consisted of 150 consecutive patients with a first primary parenchymal ICH, and the control group consisted of 271 age- and sex-matched individuals who underwent brain MRI in a health care center. We compared cerebral microbleeds (CMBs), white matter hyperintensities (WMHs), enlarged perivascular space (EPVS), and lacunae in the ICH and control groups. RESULTS: A total of 1278 CMB lesions were identified in 121 of the 150 patients in the ICH group (80.6%), while 77 CMB lesions were found in 32 of the 271 individuals in the control group (11.8%). WMH and EPVS were more severe and lacunae were more frequent in the ICH patients than in the control group. When receiver operating characteristic (ROC) curves were plotted, number of CMBs most significantly predicted ICH. All imaging markers were significantly associated with ICH in every age group. The location of CMBs coincided with the location of ICH, and ICH volume correlated with CMB count. CONCLUSION: All MRI markers for SVD were worse in ICH patients than in healthy controls, and these markers were prominent even in young ICH patients. Lacunae, WMH, EPVS, and CMB should be considered as factors related with spontaneous ICH.


Asunto(s)
Hemorragia Cerebral/complicaciones , Hemorragia Cerebral/diagnóstico por imagen , Enfermedades de los Pequeños Vasos Cerebrales/complicaciones , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Imagen por Resonancia Magnética , Adulto , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Biomarcadores , Estudios de Casos y Controles , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Curva ROC , Estudios Retrospectivos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
16.
J Clin Neurosci ; 64: 155-159, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30902438

RESUMEN

White matter hyperintensity (WMH) in the general population has clinical importance. However, MRI (magnetic resonance imaging) is not suitable for screening purposes due to high cost and restricted availability. We hypothesized that performance on the trail making test black & white (TMT-B&W) may correlate with WMH and provide a screening tool for patients with WMH. Intergroup comparisons between WMH (+) (a Fazekas score of ≥2) and WMH (-) (<2) were performed for time variables in type A, B, B-A, B/A, B*A and errors in type A and B. To determine an ideal cutoff value and confirm the diagnostic performance of TMT-B&W on the presence of WMH (+), the area under the receiver operating characteristics curve (AUC) was analyzed. Multiple linear regression analysis was used, adjusting for age and education, to correlate the normalized WMH volumes and TMT-B&W performance. We show that higher WMH correlates with a significant increase in completion time for type A (p < 0.001) and B (p = 0.006) TMT-B&W. In AUC analysis, the optimal cutoff time to complete type A was 75 s [sensitivity, 66.7%; specificity, 67.2%; %; p = 0.001; AUC, 0.729; 95% confidence interval (CI), 0.600-0.858]. Additionally, there were significant correlations between normalized WMH volume and TOTAL-A (B = 0.233, p = 0.016) and errors in type A (B = 0.353, p < 0.001). We identified the correlation between the performance in TMT-B&W and WMH burden, and propose its potential clinical utility in predicting brain WMH burden.


Asunto(s)
Encéfalo/patología , Leucoaraiosis/diagnóstico , Prueba de Secuencia Alfanumérica , Sustancia Blanca/patología , Adulto , Anciano , Femenino , Humanos , Leucoaraiosis/patología , Modelos Lineales , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Análisis Multivariante
18.
Eur Radiol ; 29(5): 2641-2650, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30421013

RESUMEN

OBJECTIVES: To determine whether fast scanned MRI using a 1.5-T scanner is a reliable method for the detection and characterization of acute ischemic stroke in comparison with conventional MRI. METHODS: From May 2015 to June 2016, 862 patients (FLAIR, n = 482; GRE, n = 380; MRA, n = 190) were prospectively enrolled in the study, with informed consent and under institutional review board approval. The patients underwent both fast (EPI-FLAIR, ETL-FLAIR, TR-FLAIR, EPI-GRE, parallel-GRE, fast CE-MRA) and conventional MRI (FLAIR, GRE, time-of-flight MRA, fast CE-MRA). Two neuroradiologists independently assessed agreements in acute and chronic ischemic hyperintensity, hyperintense vessels (FLAIR), microbleeds, susceptibility vessel signs, hemorrhagic transformation (GRE), stenosis (MRA), and image quality (all MRI), between fast and conventional MRI. Agreements between fast and conventional MRI were evaluated by generalized estimating equations. Z-scores were used for comparisons of the percentage agreement among fast FLAIR sequences and fast GRE sequences and between conventional and fast MRA. RESULTS: Agreements of more than 80% were achieved between fast and conventional MRI (ETL-FLAIR, 96%; TR-FLAIR, 97%; EPI-GRE, 96%; parallel-GRE, 98%; fast CE-MRA, 86%). ETL- and TR-FLAIR were significantly superior to EPI-FLAIR in the detection of acute ischemic hyperintensity and hyperintense vessels, while parallel-GRE was significantly superior to EPI-GRE in the detection of susceptibility vessel sign (p value < 0.05 for all). There were no significant differences in the other scores and image qualities (p value > 0.05). CONCLUSIONS: Fast MRI at 1.5 T is a reliable method for the detection and characterization of acute ischemic stroke in comparison with conventional MRI. KEY POINTS: • Fast MRI at 1.5 T may achieve a high intermethod reliability in the detection and characterization of acute ischemic stroke with a reduction in scan time in comparison with conventional MRI.


Asunto(s)
Isquemia Encefálica/diagnóstico , Encéfalo/patología , Imagen por Resonancia Magnética/instrumentación , Enfermedad Aguda , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Angiografía por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Korean J Radiol ; 18(6): 888-897, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29089821

RESUMEN

OBJECTIVE: To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. MATERIALS AND METHODS: Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. RESULTS: Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. CONCLUSION: Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary.


Asunto(s)
Revisión de la Investigación por Pares , Interfaz Usuario-Computador , Pruebas Diagnósticas de Rutina , Humanos , Reproducibilidad de los Resultados
20.
J Surg Oncol ; 116(7): 870-876, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28650524

RESUMEN

BACKGROUND AND OBJECTIVES: To compare US-guided core-needle biopsy (USCNB) and US-guided fine-needle aspiration (USFNA) of suspicious cervical lymph nodes for staging workup of malignancies in locations other than the head and neck using propensity score matching (PSM). METHODS: This retrospective cohort study included 108 patients who underwent USFNA and 1058 who underwent USCNB for suspicious cervical lymph nodes detected by imaging modalities during the staging workup for malignancies located in regions other than the head and neck. The primary outcome was defined as the inconclusive results. To evaluate the procedures according to the outcome, we performed univariate and multivariate logistic regression analyses and a 1:1 PSM of USCNB and USFNA. RESULTS: There was no complication for both USFNA and USCNB. The inconclusive results were 6.5% (7/108) for USFNA and 1.6% (17/1058) for USCNB. A significantly lower rate of the inconclusive results in USCNB than in USFNA before matching was maintained after a 1:1 PSM of 103 patients from each group (before PSM, odds ratio (OR) = 4.489, 95% confidence interval (CI) [1.803-11.177], P = 0.001; after PSM, OR = 1.060, 95%CI [1.013-1.109], P = 0.012). CONCLUSIONS: Because USCNB can reduce inconclusive results compared to USFNA, it could be more helpful for staging workup of malignancies in locations other than the head and neck in patients with suspicious cervical lymph nodes.


Asunto(s)
Biopsia con Aguja Fina/métodos , Biopsia con Aguja Gruesa/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Biopsia Guiada por Imagen/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Ultrasonografía Intervencional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...