Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(1): 106-114, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29521013

RESUMEN

OBJECTIVES: To evaluate the clinical and health status outcomes of patients undergoing superficial femoral artery (SFA) revascularization using the Shape Memory Alloy Recoverable Technology (S.M.A.R.T.®) nitinol self-expanding stent through 3 years of follow-up. BACKGROUND: Limited long-term data are available describing the durability of benefits after femoropopliteal revascularization. METHODS: In a multicenter, prospective, core-lab adjudicated study, 250 subjects with de novo or restenotic femoropopliteal arterial lesions were treated with the S.M.A.R.T.® stent. The primary endpoint of target vessel patency, a composite of ultrasound-assessed patency and freedom from clinically driven target lesion revascularization (TLR), was evaluated through 3 years. Secondary endpoints included stent fracture and health status. Health status was measured using generic and disease-specific instruments, including the Peripheral Artery Questionnaire (PAQ). RESULTS: At 3-year follow-up, Kaplan-Meier estimated target vessel patency was 72.7%, freedom from clinically driven TLR was 78.5%, and the incidence of stent fracture was 3.6%. The PAQ summary score was markedly impaired at baseline (mean 37.3 ± 19.6 points) and improved substantially at 1 month (mean change from baseline of 31.4 points, 95% CI: 28.5-34.3; P < 0.001). Disease-specific health status benefits assessed by the PAQ were largely preserved through 3 years of follow-up (mean change from baseline, 28.0 points, 95% CI: 24.3-31.7; P < 0.0001). CONCLUSIONS: In patients undergoing revascularization for moderately complex SFA disease, use of the self-expanding S.M.A.R.T® stent was associated with a high rate of target vessel patency through 3 years and led to substantial and sustained health status benefits.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Femoral/cirugía , Enfermedad Arterial Periférica/cirugía , Arteria Poplítea/cirugía , Calidad de Vida , Stents Metálicos Autoexpandibles , Anciano , Aleaciones , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/psicología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Supervivencia sin Progresión , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Encuestas y Cuestionarios , Factores de Tiempo , Ultrasonografía Intervencional , Estados Unidos , Grado de Desobstrucción Vascular
2.
J Vasc Interv Radiol ; 26(1): 21-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25454735

RESUMEN

PURPOSE: To assess safety and efficacy of the S.M.A.R.T. Vascular Stent System (Cordis Corp, Fremont, California) in obstructive superficial femoral artery (SFA) disease. MATERIALS AND METHODS: The single-arm, multicenter STROLL study (S.M.A.R.T. Nitinol Self-Expanding Stent in the Treatment of Obstructive Superficial Femoral Artery Disease) included 250 patients (250 lesions in SFA or proximal popliteal artery). The efficacy endpoint was primary patency defined by freedom from binary restenosis (peak systolic velocity ratio > 2.5) as derived by duplex ultrasound plus clinically driven target lesion revascularization (TLR) at 12 months. RESULTS: Mean age of patients was 67.7 years ± 10.3; 47.2% of patients had diabetes; distribution of Rutherford/Becker classes 2, 3, and 4 was 45.8%, 51.4%, and 2.8%. Mean lesion length and reference vessel diameter were 77.3 mm ± 35.3 and 4.9 mm ± 0.7, respectively (23.6% cases with total occlusions). The 30-day freedom from major adverse events (death, index limb amputation, clinically driven TLR) was 100%. The 1-year primary patency was 81.7% by Kaplan-Meier estimate. The presence of diabetes or total occlusion had no effect on primary patency. Ankle-brachial index was 0.4-0.8 in 84.6% of patients at baseline and improved to > 0.8 in 81.0% of patients at 12 months. The proportion of patients in Rutherford/Becker class 3-4 was reduced from 54.2% at baseline to 8.0% at 12 months. Four patients (2.0%) experienced single-stent strut fracture (type I) at 1 year, without associated loss of stent patency. CONCLUSIONS: The S.M.A.R.T. Vascular Stent System proved to be safe and effective for endovascular treatment of obstructive SFA and proximal popliteal artery disease, based on 1-year vessel patency and associated hemodynamic and clinical improvements.


Asunto(s)
Aterosclerosis/diagnóstico por imagen , Aterosclerosis/terapia , Arteria Femoral/diagnóstico por imagen , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Stents , Anciano , Aleaciones , Constricción Patológica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Resultado del Tratamiento , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...