Artif Organs ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189702

RESUMEN

BACKGROUND: Hemolysis in mechanical circulatory support systems is currently determined quantitatively. To also locally resolve hemolysis, we are developing a fluorescent hemolysis detection method. This requires a translucent two-phase blood analog fluid combined with particle image velocimetry, an optical flow field measurement. The blood analog fluid is composed of red blood cell surrogates. However, producing surrogates in sufficient volume is a challenge. We therefore present a high-volume and high-concentration production for our surrogates: ghost cells, hemoglobin-depleted erythrocytes. METHODS: In the ghost cell production, the hemoglobin is removed by a repeated controlled osmolar lysis. We have varied the solution mixture, centrifugation time, and centrifugation force in order to increase production efficiency. The production is characterized by measurements of output volume, hematocrit, transparency, and rheology of the blood analog fluid. RESULTS: The volume of produced ghost cells was significantly increased, and reproducibility was improved. An average production of 389 mL of ghost cells were achieved per day. Those ghost cells diluted in plasma have a rheology similar to blood while being permeable to light. CONCLUSION: The volume of ghost cells produced is sufficient for optical measurements as particle image velocimetry in mechanical circulatory support systems. This makes further work on experimental measurements for a locally resolved hemolysis detection possible.

2.
Anal Chim Acta ; 1312: 342766, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834280

RESUMEN

BACKGROUND: Intravascular hemolysis is associated with massive release of hemoglobin and consequently labile heme into the blood, resulting in prothrombotic and proinflammatory events in patients. Though heme is well-known to participate in these adverse effects, it is not monitored. Instead, haptoglobin and hemoglobin serve as clinical biomarkers. The quantification of labile heme together with hemoglobin, however, should be considered in clinical diagnosis as well, to obtain a complete picture of the hemolytic state in patients. So far, quantification techniques for labile heme were not yet systematically analyzed and compared for their clinical application potential, especially in the presence of hemoglobin. RESULTS: Two commercial assays (Heme Assay Kit®, Hemin Assay Kit®) and five common approaches (pyridine hemochromogen assay, apo-horseradish peroxidase-based assay, UV/Vis spectroscopy, HPLC, mass spectrometry) were analyzed concerning their linearity, accuracy, and precision, as well as their ability to distinguish between hemoglobin-bound heme and labile heme. Further, techniques for the quantification of hemoglobin (Harboe method, SLS method, Hemastix®) were included to study their selectivity for hemoglobin and potential interference by the presence of labile heme. Both, indirect and direct approaches were suitable for the determination of a wide concentration of heme (∼0.02-45 µM) and hemoglobin (∼0.002-17 µM). A clear distinction between hemoglobin-bound heme and labile heme with one method was not possible. Thus, a novel combined approach is presented and applied to human and porcine plasma samples for the determination of hemoglobin and labile heme. SIGNIFICANCE: Our results demonstrate the need to develop improved techniques to differentiate labile and protein-bound heme for early detection of intravascular hemolysis. Here, we present a novel strategy by combining two spectroscopic methods, which is most reliable as an easy-to-use tool for the determination of hemoglobin and heme levels in plasma samples for the diagnosis of intravascular hemolysis and in basic biomedical research.


Asunto(s)
Hemo , Hemoglobinas , Hemólisis , Hemo/química , Hemo/análisis , Hemoglobinas/análisis , Humanos , Animales , Porcinos , Cromatografía Líquida de Alta Presión
3.
Biomater Sci ; 12(8): 2149-2164, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38487997

RESUMEN

The sole effective treatment for most patients with heart valve disease is valve replacement by implantation of mechanical or biological prostheses. However, mechanical valves represent high risk of thromboembolism, and biological prostheses are prone to early degeneration. In this work, we aim to determine the potential of novel environmentally-friendly non-isocyanate polyurethanes (NIPUs) for manufacturing synthetic prosthetic heart valves. Polyhydroxyurethane (PHU) NIPUs are synthesized via an isocyanate-free route, tested in vitro, and used to produce aortic valves. PHU elastomers reinforced with a polyester mesh show mechanical properties similar to native valve leaflets. These NIPUs do not cause hemolysis. Interestingly, both platelet adhesion and contact activation-induced coagulation are strongly reduced on NIPU surfaces, indicating low thrombogenicity. Fibroblasts and endothelial cells maintain normal growth and shape after indirect contact with NIPUs. Fluid-structure interaction (FSI) allows modeling of the ideal valve design, with minimal shear stress on the leaflets. Injection-molded valves are tested in a pulse duplicator and show ISO-compliant hydrodynamic performance, comparable to clinically-used bioprostheses. Poly(tetrahydrofuran) (PTHF)-NIPU patches do not show any evidence of calcification over a period of 8 weeks. NIPUs are promising sustainable biomaterials for the manufacturing of improved prosthetic valves with low thrombogenicity.


Asunto(s)
Prótesis Valvulares Cardíacas , Poliuretanos , Humanos , Poliuretanos/química , Isocianatos , Células Endoteliales , Válvula Aórtica/cirugía
4.
ASAIO J ; 69(10): 924-931, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37314830

RESUMEN

Refurbishing single use extracorporeal membrane oxygenation (ECMO) oxygenators for in vitro research applications is common. However, the refurbishment protocols that are established in respective laboratories have never been evaluated. In the present study, we aim at proving the relevance of a well-designed refurbishing protocol by quantifying the burden of repeatedly reused oxygenators. We used the same three oxygenators in 5 days of 6 hours whole blood experiments. During each experiment day, the performance of the oxygenators was measured through the evaluation of gas transfer. Between experiment days, each oxygenator was refurbished applying three alternative refurbishment protocols based on purified water, pepsin and citric acid, and hydrogen peroxide solutions, respectively. After the last experiment day, we disassembled the oxygenators for visual inspection of the fiber mats. The refurbishment protocol based on purified water showed strong degeneration with a 40-50 %-performance drop and clearly visible debris on the fiber mats. Hydrogen peroxide performed better; nevertheless, it suffered a 20% decrease in gas transfer as well as clearly visible debris. Pepsin/citric acid performed best in the field, but also suffered from 10% performance loss and very few, but visible debris. The study showed the relevance of a well-suited and well-designed refurbishment protocol. The distinct debris on the fiber mats also suggests that reusing oxygenators is ill-advised for many experiment series, especially regarding hemocompatibility and in vivo testing. Most of all, this study revealed the relevance of stating the status of test oxygenators and, if refurbished, comment on the implemented refurbishment protocol in detail.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Oxigenadores de Membrana , Peróxido de Hidrógeno , Pepsina A , Oxigenadores , Técnicas In Vitro , Ácido Cítrico , Agua
5.
Artif Organs ; 46(5): 922-931, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34904246

RESUMEN

BACKGROUND: The major obstacle of blood-contacting medical devices is insufficient hemocompatibility, particularly thrombogenicity and platelet activation. Pre-clinical in-vitro testing allows for the evaluation of adverse thrombogenicity-related events, but is limited, among others, by the availability and quantity of human blood donations. The use of animal blood is an accepted alternative for several tests; however, animal and particularly abattoir blood might present species-specific differences to human blood as well as elevated blood values, and pre-activated platelets due to stressed animals and non-standardized blood collection. MATERIAL & METHODS: To this end, we investigated porcine abattoir blood in comparison to human donor blood with the focus on platelet pre-activation and remaining activation potential. By means of light transmission aggregometry, aggregation kinetics of platelet rich plasma after stimulation with three different concentrations of each adenosine diphosphate (ADP) (5 µM, 10 µM, 20 µM) and collagen (2.5 µg/ml, 5 µg/ml, 10 µg/ml) were monitored. RESULTS: The activation with collagen revealed no significant differences in platelet behavior of the two species. In contrast, stimulation with ADP resulted in a lower maximum aggregation and a high disaggregation for porcine abattoir blood. The latter is a species-specific phenomenon of porcine platelets. Variations within each study cohort were comparable for human and abattoir pig. CONCLUSION: The similarities in platelet activation following collagen stimulation and the preservation of the porcine-specific reaction to ADP prove a general functionality of the abattoir blood. This finding provides a first step towards the complete validation of the porcine abattoir blood model.


Asunto(s)
Mataderos , Agregación Plaquetaria , Adenosina Difosfato/farmacología , Animales , Plaquetas , Colágeno/farmacología , Humanos , Inhibidores de Agregación Plaquetaria , Pruebas de Función Plaquetaria , Especificidad de la Especie , Porcinos
6.
Cardiovasc Intervent Radiol ; 45(1): 112-120, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34796375

RESUMEN

PURPOSE: The presented in-vitro study provides a comparison of various catheters for mechanical treatment of large-burden pulmonary embolism (PE) under standardized conditions, using a new test rig. Dedicated aspiration catheters (JETi®, Penumbra Indigo®, Aspirex®) were compared with standard catheters (Pigtail, Multi-Purpose, Balloon Catheter) applied for embolus fragmentation. MATERIALS AND METHODS: Emboli prepared from porcine blood were washed into the test rig which consists of anatomical models of the pulmonary artery (PA) and of the right heart in combination with a pulsatile drive system. For all catheters, the duration of the recanalization procedure and the weight percentage (wt%) of the remaining, removed and washed-down clot fractions were evaluated. For aspiration catheters, the aspirated volume was measured. RESULTS: All catheters achieved full or partial recanalization. The aspiration catheters showed a significantly (p < 0.05) lower procedure time (3:15 min ± 4:26 min) than the standard fragmentation catheters (7:19 min ± 4:40 min). The amount of thrombus removed by aspiration was significantly (p < 0.001) higher than that by fragmentation, averaging 86.1 wt% ± 15.6 wt% and 31.7 wt% ± 3.8 wt%, respectively. Nonetheless, most of the residue was fragmented into pieces of ≥ 1 mm and washed down. Only in 2 of 36 tests, a residual thrombus of 11.9 wt% ± 5.1 wt% remained in the central PA. CONCLUSION: Comparison under standardized in-vitro patho-physiological conditions showed that embolus fragmentation with standard catheters is clearly inferior to aspiration with dedicated catheters in the treatment of large-burden PE, but can still achieve considerable success. LEVEL OF EVIDENCE: No level of evidence, experimental study.


Asunto(s)
Embolia Pulmonar , Trombosis , Animales , Catéteres , Arteria Pulmonar , Embolia Pulmonar/terapia , Porcinos , Trombectomía , Resultado del Tratamiento
7.
Ann Biomed Eng ; 49(12): 3165-3175, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34431015

RESUMEN

Despite improved hemocompatibility of left-ventricular assist devices (LVADs), assessment of blood damage remains mandatory in preclinical testing as standardized by ASTM-F1841. The most relevant test fluid is fresh, non-pooled human blood, but the limited volume of a standard donation requires significantly smaller loops than those commonly used with animal blood. In a recent study with porcine blood, we verified a miniaturized test loop with only 160 mL for the ASTM-conform paired testing of at least two LVADs and a static reference. Here, we validated this mini test loop for standardized assessment of blood damage with one 450-mL single donation of fresh human blood. Blood damage was assessed for HeartMate 3 and BPX-80 in 9 experiments with heparinized human blood for 6 hours. We analyzed plasma free hemoglobin, von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. Overall, we observed less blood damage compared to our previous study; however, the differences in mean indices of hemolysis and in mean normalized vWF-ratio between BPX-80 and HeartMate 3 were consistent for human blood. Thus, our mini test loop proved to be valid for preclinical standardized assessment of blood damage with only 450 mL of fresh human blood.


Asunto(s)
Corazón Auxiliar/efectos adversos , Hemólisis , Animales , Humanos , Ensayo de Materiales , Miniaturización , Porcinos
8.
Artif Organs ; 45(12): 1513-1521, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34312890

RESUMEN

Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.


Asunto(s)
Corazón Artificial/efectos adversos , Tromboelastografía/instrumentación , Trombosis/etiología , Animales , Diseño de Equipo , Porcinos/sangre , Tromboelastografía/métodos
9.
J Transl Med ; 19(1): 2, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33402176

RESUMEN

BACKGROUND: Treating severe forms of the acute respiratory distress syndrome and cardiac failure, extracorporeal membrane oxygenation (ECMO) has become an established therapeutic option. Neonatal or pediatric patients receiving ECMO, and patients undergoing extracorporeal CO2 removal (ECCO2R) represent low-flow applications of the technology, requiring lower blood flow than conventional ECMO. Centrifugal blood pumps as a core element of modern ECMO therapy present favorable operating characteristics in the high blood flow range (4 L/min-8 L/min). However, during low-flow applications in the range of 0.5 L/min-2 L/min, adverse events such as increased hemolysis, platelet activation and bleeding complications are reported frequently. METHODS: In this study, the hemolysis of the centrifugal pump DP3 is evaluated both in vitro and in silico, comparing the low-flow operation at 1 L/min to the high-flow operation at 4 L/min. RESULTS: Increased hemolysis occurs at low-flow, both in vitro and in silico. The in-vitro experiments present a sixfold higher relative increased hemolysis at low-flow. Compared to high-flow operation, a more than 3.5-fold increase in blood recirculation within the pump head can be observed in the low-flow range in silico. CONCLUSIONS: This study highlights the underappreciated hemolysis in centrifugal pumps within the low-flow range, i.e. during pediatric ECMO or ECCO2R treatment. The in-vitro results of hemolysis and the in-silico computational fluid dynamic simulations of flow paths within the pumps raise awareness about blood damage that occurs when using centrifugal pumps at low-flow operating points. These findings underline the urgent need for a specific pump optimized for low-flow treatment. Due to the inherent problems of available centrifugal pumps in the low-flow range, clinicians should use the current centrifugal pumps with caution, alternatively other pumping principles such as positive displacement pumps may be discussed in the future.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Niño , Simulación por Computador , Hemodinámica , Hemólisis , Humanos , Recién Nacido
10.
ACS Biomater Sci Eng ; 7(2): 553-561, 2021 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-33481566

RESUMEN

The hemocompatibility of blood-contacting medical devices remains one of the major challenges in medical device development. A common tool for the analysis of adherent and activated platelets on materials following in vitro tests is microscopy. Currently, most researchers develop their own routines, resulting in numerous different methods that are applied. The majority of those (semi-)manual methods analyze only a very small fraction of the material surface (<1%), which neglects the inhomogeneity of platelet distribution and makes results hardly comparable. Within this study, we examined the relation between the fraction of analyzed sample area and the platelet adhesion result. By means of image segmentation and machine learning algorithms, 103 100 microscopy images were analyzed automatically. We discovered a crucial impact of the analyzed surface fraction and thus a misrepresentation of a surface's platelet adhesion unless up to 40% of the sample surface is analyzed. These findings underline the necessity of standardization in the field of in vitro hemocompatibility tests and analyses in particular and provide a first basis to make future tests more reliable and comparable.


Asunto(s)
Materiales Biocompatibles , Adhesividad Plaquetaria , Plaquetas , Técnicas In Vitro , Ensayo de Materiales
11.
Biotechnol J ; 15(4): e1900239, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31904165

RESUMEN

The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi-automation of the existing method by using the large volume batch production system, productivity is increased 60-fold to 188 mL while almost doubling process efficiency to 23.5%. Time-consuming manual work such as pipetting is now supported by sensor-based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small-scale fluorescent hemolysis detection method.


Asunto(s)
Técnicas de Cultivo Celular por Lotes/métodos , Hemólisis , Técnicas In Vitro/instrumentación , Técnicas In Vitro/métodos , Técnicas de Cultivo Celular por Lotes/instrumentación , Biotecnología/instrumentación , Biotecnología/métodos , Eritrocitos , Colorantes Fluorescentes , Hematócrito/métodos
12.
Artif Organs ; 44(4): 419-427, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31660616

RESUMEN

Passively levitated ventricular assist devices (VADs) are vulnerable to impeller-housing contact and could benefit from surface coatings that improve wear resistance. Such coatings can be manufactured by plasma electrolytic oxidation (PEO), but their suitability for blood-contact applications needs further investigation. We therefore compared blood-surface interactions of polished titanium grade 5 (Ti Gr 5), as a general VAD reference material, uncoated ground titanium grade 4 (Ti Gr 4) and two commercially available PEO coatings on Ti Gr 4. In n = 4 static platelet adhesion tests, material samples were incubated with platelet-rich plasma (PRP) and consecutively analyzed for adhesive platelets by immunofluorescence microscopy. Additionally, PRP supernatant of incubated material samples was analyzed for changes in antithrombin III and fibrinogen concentrations by turbodimetry and enzyme-linked immunosorbent assay, respectively. We could not find any significant differences between the materials in the analyzed hemocompatibility markers (P > .05). Thus, we conclude that PEO coatings might offer a similar hemocompatibility to that of polished Ti Gr 5 and uncoated Ti Gr 4. Nevertheless, future studies should investigate blood-surface interactions of PEO coatings under realistic VAD-related flow conditions to better evaluate their potential for VAD applications.


Asunto(s)
Coagulación Sanguínea , Cerámica , Corazón Auxiliar , Adhesividad Plaquetaria , Titanio , Técnicas Electroquímicas , Estudios de Factibilidad , Humanos , Ensayo de Materiales
13.
Ann Biomed Eng ; 48(2): 768-779, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31724071

RESUMEN

Although the hemocompatibility of left-ventricular assist devices (LVADs) has continuously improved, assessment of hemolysis remains mandatory in pre-clinical testing. The ASTM-F1841 has standardized this assessment since 1997. However, the recommended usage of fresh, non-pooled human blood is hardly feasible with the test loop volume specified therein, when testing the device under test versus a predicate device as required by the international standard 10993-4. In this study, we compared ASTM-conforming (ASTM) and downscaled (mini) test loops with a one-third priming volume for the assessment of blood damage at the ASTM operating point. Blood damage was assessed for HeartMate 3 and BPX-80 in 6 experiments with heparinized porcine slaughterhouse blood for 6 h. We analyzed plasma free hemoglobin (pfHb), von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. The mini test loops provided significantly higher pfHb increase and consistently stronger vWF-ratio decrease and yielded a significantly better differentiation of the pumps. Interestingly, indices of hemolysis were generally lower in the mini set-up, indicating less adverse effects by the mini loop itself. Thus, we propose our mini test loop as suitable tool for clinically relevant standardized assessment of blood damage by future LVADs with single-donation human blood.


Asunto(s)
Corazón Auxiliar , Ensayo de Materiales , Animales , Hemoglobinas/metabolismo , Hemólisis , Humanos , Porcinos , Factor de von Willebrand/metabolismo