Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39438691

RESUMEN

BACKGROUND: Over the past decade, the range of surgical options to benign prostatic obstruction (BPO) has expanded significantly with the advent of minimally invasive surgical therapies (MISTs). Nevertheless, the available evidence in the field is heterogeneous. Efficacy and safety thresholds are yet to be determined. OBJECTIVE: To evaluate perioperative and long-term complications after MISTs - including Aquablation, steam injection (Rezum), Transperineal laser ablation of the prostate (TPLA), implantation of a prostatic urethral lift (PUL) and temporary implantable nitinol device (iTIND) - in patients with lower urinary tract symptoms due to BPO. EVIDENCE ACQUISITION: A systematic literature search was conducted in January 2024 using Medline (via PubMed), Embase (via Ovid), Scopus, and Web of Science. The search strategy used PICO criteria (Patients, Interventions, Comparisons, Outcomes) [1], focusing specifically on patients with BPH-associated LUTS who underwent MIST or other comparative treatments, aiming to assess both perioperative and long-term safety outcomes. Article selection was conducted in accordance with the PRISMA guidelines. The risk of bias and the quality of the articles included were assessed. A dedicated data extraction form was used to collect the data of interest. EVIDENCE SYNTHESIS: The initial electronic search identified 3660 records, of which 24 ultimately met the inclusion criteria and were included in the analysis. Overall, Aquablation was associated with a higher major complications rate of 14% (IQR 6-22), particularly in the case of patients with prostates <70 ml. PUL showed a higher early postoperative acute urinary retention rate (10.9%, IQR 9.2-12.3%), while 1.4% of patients treated with iTIND experienced major perioperative complications. Urinary tract infections were mostly reported in series assessing TPLA and Rezum. CONCLUSIONS: The adoption of MISTs for LUTS due to BPH is associated with a varied spectrum of perioperative and long-term complications. Our findings showed an acceptable safety profile with specific complications dependent on the type of MIST performed, highlighting the importance of individualized patient selection and procedure-specific considerations.

3.
World J Urol ; 42(1): 338, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767673

RESUMEN

PURPOSE: To compare two cohorts of patients submitted to robot-assisted partial nephrectomy (RAPN) with vs without the use of three-dimensional virtual models (3DVMs). METHODS: We screened a prospective consecutive cohort of 152 patients submitted to RAPN with 3DVM and 1264 patients submitted to RAPN without 3DVM between 2019 and 2022. Propensity score matching analysis (PSMA) was applied. Primary endpoint was to evaluate whereas RAPNs with 3DVM were superior in terms of functional outcomes at 12-month. Secondary endopoints were to compare perioperative and oncological outcomes. Multivariable logistic regression analyses (MVA) tested the associations of clinically significant eGFR drop and 3DVMs. Subgroups analysis was performed for PAUDA-risk categories. RESULTS: 100 patients for each group were analyzed after PSMA. RAPN with 3DVM presented a higher rate of selective/no clamping procedure (32% vs 16%, p = 0.03) and a higher enucleation rate (40% vs 29%, p = 0.04). As concern to primary endopoint, 12-month functional preservation performed better within 3DVM group in terms of creatinine serum level (median 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8], p = 0.03) and eGFR (median 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1], p = 0.03). However, this result was confirmed only in the PADUA ≥ 10 renal masses. Regarding secondary endpoints, no significative difference emerged between the two cohorts. MVA confirmed 3DVM as a protective factor for clinically significant eGFR drop only in high-risk (PADUA ≥ 10) masses. CONCLUSIONS: RAPN performed with the use of 3DVM assistance resulted in lower incidence of global ischemia and higher rate of enucleations. The positive impact of such technology was found at 12-month only in high-risk renal masses.


Asunto(s)
Imagenología Tridimensional , Neoplasias Renales , Nefrectomía , Puntaje de Propensión , Procedimientos Quirúrgicos Robotizados , Humanos , Nefrectomía/métodos , Masculino , Femenino , Neoplasias Renales/cirugía , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Carcinoma de Células Renales/cirugía
4.
Urologia ; 91(3): 563-567, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38752506

RESUMEN

INTRODUCTION: Benefits and harms of avoid the sent placement during IntraCorporeal Neobladder configuration are still debated. Our objective was to describe the step-by-step technique of Florence intracorporeal neobladder (FloRIN) configuration performed with stentless procedure focusing on perioperative and mid-term functional outcomes. MATERIALS AND METHODS: In this single institution prospective randomized 1:1 series all consecutive patients underwent Robot-Assisted Radical Cystectomy (RARC) and FloRIN reconfiguration from January 2021 to March 2021 were enrolled. Functional perioperative and mid-term outcomes were gathered. Postoperative complications were graded according to Clavien-Dindo classification and divided in early (<30 days from discharge) and delayed (>30 days). RESULTS: Overall, 10 patients were included in the analysis. Of these, the 50.0% was treated with Stentless FloRIN. In terms of baseline features, no differences were recorded between the two groups. Median age was 65 and 66 years while median BMI was 27 and 25 in the stentless and in the stent group, respectively. Concerning intraoperative variables, no intraoperative complications as well as open conversion occurred among both groups. As regard introperative features, a shorter console time was associated with stentless procedure (331 min vs 365 min). In terms of perioperative outcomes, canalization and time to drainage removal didn't differ between groups while length of hospital stay was significantly lower in stentless group 10 days versus 14 days. Early and delayed postoperative complication rate was not influenced by the ureteral management at a preliminary assessment with comparable rates of Clavien Dindo ⩾ 3a between the two groups. Mid-term functional outcomes did not differ between groups in terms of kidney function loss. CONCLUSIONS: FloRIN with Stentless technique showed functional and perioperative preliminary outcomes comparable with the standard ureteral management strategy. Further series with longer functional follow-up assessment will be needed to confirm our preliminary results.


Asunto(s)
Cistectomía , Procedimientos Quirúrgicos Robotizados , Uréter , Humanos , Anciano , Masculino , Estudios Prospectivos , Cistectomía/métodos , Femenino , Uréter/cirugía , Resultado del Tratamiento , Persona de Mediana Edad , Stents , Neoplasias de la Vejiga Urinaria/cirugía , Reservorios Urinarios Continentes , Complicaciones Posoperatorias/epidemiología , Derivación Urinaria/métodos
5.
Urologia ; 91(3): 568-573, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38770765

RESUMEN

PURPOSE: To compare two cohorts of patients submitted to robot-assisted partial nephrectomy (RAPN) for highly-complex renal masses (PADUA ⩾ 10) with versus without the use of 3DVMs. MATERIALS AND METHODS: We screened a prospective consecutive cohort of 152 patients submitted to RAPN with 3DVM and 1264 patients submitted to RAPN without 3DVM between 2019 and 2022. Only PADUA ⩾ 10 cases were considered eligible for analysis. Propensity score matching (PSM) analysis was applied. Primary endpoint was to evaluate whereas RAPNs with 3DVM were superior in terms of functional outcomes at 12-month. Secondary outcomes were to compare perioperative and oncological outcomes. Multivariable logistic regression analyses (MVA) tested the associations of clinically significant eGFR drop and 3DVMs. Subgroups analysis was performed for PAUDA-risk categories. RESULTS: Thirty seven patients for each group were analyzed after PSM. RAPN with 3DVM presented a higher rate of selective/no clamping procedure (32.5% vs 16.2%, p = 0.03) and a higher enucleation rate (43.2% vs 29.8%, p = 0.04). Twelve-month functional preservation performed better within 3DVM group in terms of creatinine serum level (median 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8], p = 0.03) and eGFR (median 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1], p = 0.03). MVA confirmed 3DVM as a protective factor for clinically significant eGFR drop in this subgroup of patients. CONCLUSIONS: RAPN performed with the use of 3DVM assistance for PADUA ⩾ 10 cases resulted in lower incidence of global ischemia and higher rate of enucleations. The positive impact of such technology was found at 12-month follow-up.


Asunto(s)
Neoplasias Renales , Nefrectomía , Procedimientos Quirúrgicos Robotizados , Humanos , Nefrectomía/métodos , Neoplasias Renales/cirugía , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Imagenología Tridimensional , Resultado del Tratamiento
6.
Eur Urol Open Sci ; 57: 84-90, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37810278

RESUMEN

Background: The role of redo partial nephrectomy (PN) for recurrent renal cell carcinoma (RCC) is still overlooked. Objective: To report our experience of salvage PN for local recurrence after previous nephron-sparing surgery (NSS). Design setting and participants: We prospectively gathered data from patients treated with robotic redo PN for locally recurrent RCC after previous NSS from January 2017 to January 2023. The type of surgical resection technique was assigned to the pathologic specimen according to the surface-intermediate-base (SIB) score. Surgical procedure: Redo PN was performed by using the Si Da Vinci robotic platform. Measurements: Operative time, warm ischemia time, and intra- and postoperative complications were recorded. The severity of postoperative complications and tumor stage were evaluated. Results and limitations: Overall, 26 patients entered the study. The median clinical diameter was 3.5 (interquartile range [IQR] 2.2-4.9) cm and the median Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score was 8 (IQR 7-9). In 14 (53.8%) cases, recurrence was at the level of previous tumor resection bed. The median operative time was 177 (IQR 148-200) min, and hilar clamping was performed in 14 (53.8%) cases with a median warm ischemia time of 16 (14.5-22) min. Pure enucleation (SIB score 0-1), hybrid enucleation (SIB score 2), and pure enucleoresection (SIB score 3) were recorded in 13 (50%), eight (30.8%), and five (19.2%) cases, respectively. The totality of recurrent RCC far from previous tumor resection bed received a SIB score of 0-1, while in 57.1% and 35.8% of recurrent RCC on previous tumor resection a hybrid enucleation and a pure enucleoresection were performed, respectively. At a median follow-up of 37 (IQR 16-45) mo, five (19%) patients experienced disease recurrence, being local and systemic in three (11.5%) and two (7.7%) patients, respectively. Conclusions: Our study highlights the feasibility and safety of redo PN for the treatment of locally recurrent RCCs after NSS, either on previous tumor resection bed or elsewhere in the kidney. Patient summary: Robotic redo partial nephrectomy is a challenging procedure. The surgeon needs to tailor the surgical strategy and tumor resection technique case by case, given the heterogeneity of clinical scenarios and the need to achieve maximal functional preservation while ensuring oncologic efficacy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...