Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Nucl Med Biol ; 43(5): 273-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27150029

RESUMEN

INTRODUCTION: Fialuridine (FIAU) is a nucleoside analog that is a substrate for bacterial thymidine kinase (TK). Once phosphorylated by TK, [(124)I]FIAU becomes trapped within bacteria and can be detected with positron emission tomography/computed tomography (PET/CT). [(124)I]FIAU PET/CT has been shown to detect bacteria in patients with musculoskeletal bacterial infections. Accurate diagnosis of prosthetic joint infections (PJIs) has proven challenging because of the lack of a well-validated reference. In the current study, we assessed biodistribution and dosimetry of [(124)I]FIAU, and investigated whether [(124)I]FIAU PET/CT can diagnose PJIs with acceptable accuracy. METHODS: To assess biodistribution and dosimetry, six subjects with suspected hip or knee PJI and six healthy subjects underwent serial PET/CT after being dosed with 74MBq (2mCi) [(124)I]FIAU intravenously (IV). Estimated radiation doses were calculated with the OLINDA/EXM software. To determine accuracy of [(124)I]FIAU, 22 subjects with suspected hip or knee PJI were scanned at 2-6 and 24-30h post IV injection of 185MBq (5mCi) [(124)I]FIAU. Images were interpreted by a single reader blinded to clinical information. Representative cases were reviewed by 3 additional readers. The utility of [(124)I]FIAU to detect PJIs was assessed based on the correlation of the patient's infection status with imaging results as determined by an independent adjudication board (IAB). RESULTS: The kidney, liver, spleen, and urinary bladder received the highest radiation doses of [(124)I]FIAU. The effective dose was 0.16 to 0.20mSv/MBq and doses to most organs ranged from 0.11 to 0.76mGy/MBq. PET image quality obtained from PJI patients was confounded by metal artifacts from the prostheses and pronounced FIAU uptake in muscle. Consequently, a correlation with infection status and imaging results could not be established. CONCLUSIONS: [(124)I]FIAU was well-tolerated in healthy volunteers and subjects with suspected PJI, and had acceptable dosimetry. However, the utility of [(124)I]FIAU for the clinical detection of PJIs is limited by poor image quality and low specificity.


Asunto(s)
Arabinofuranosil Uracilo/análogos & derivados , Artropatías/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Adulto , Arabinofuranosil Uracilo/efectos adversos , Arabinofuranosil Uracilo/farmacocinética , Femenino , Humanos , Artropatías/metabolismo , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/efectos adversos , Infecciones Relacionadas con Prótesis/metabolismo , Radiometría , Seguridad , Distribución Tisular
2.
Radiology ; 259(3): 875-84, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21325035

RESUMEN

UNLABELLED: Quantitative imaging biomarkers could speed the development of new treatments for unmet medical needs and improve routine clinical care. However, it is not clear how the various regulatory and nonregulatory (eg, reimbursement) processes (often referred to as pathways) relate, nor is it clear which data need to be collected to support these different pathways most efficiently, given the time- and cost-intensive nature of doing so. The purpose of this article is to describe current thinking regarding these pathways emerging from diverse stakeholders interested and active in the definition, validation, and qualification of quantitative imaging biomarkers and to propose processes to facilitate the development and use of quantitative imaging biomarkers. A flexible framework is described that may be adapted for each imaging application, providing mechanisms that can be used to develop, assess, and evaluate relevant biomarkers. From this framework, processes can be mapped that would be applicable to both imaging product development and to quantitative imaging biomarker development aimed at increasing the effectiveness and availability of quantitative imaging. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100800/-/DC1.


Asunto(s)
Biomarcadores , Diagnóstico por Imagen , Difusión de Innovaciones , Evaluación de la Tecnología Biomédica/normas , Investigación Biomédica/organización & administración , Conflicto de Intereses , Aprobación de Recursos , Europa (Continente) , Humanos , Valor Predictivo de las Pruebas , Estados Unidos , United States Food and Drug Administration
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA