RESUMEN
BACKGROUND: The safety and efficacy of CA for AF and left-sided atrial arrhythmias (AA) in patients with left atrial appendage occlusion (LAAO) devices are lacking. METHODS: This is a single-center retrospective registry that included all patients with prior LAAO who underwent catheter ablation for AF or left-sided atrial arrhythmia from January 2020-January 2023. The primary outcomes were procedure-related complications, device-related complications, AA recurrence, and stroke. RESULTS: A total of 30 patients with prior LAAO were included in the analysis (mean age 75.1 ± 7.1 years old, 50% male, mean CHA2DS2-VASc score 4 ± 1.6, 46.7% paroxysmal AF, 73.3% had prior AF ablation, mean time to ablation 475 ± 365 days). 93.3% (n = 28) and 6.6% (n = 2) patients had ablation for AF (46.7% paroxysmal, 36.7% persistent, 10% long-standing persistent) and left-sided atrial tachycardia, respectively. 16.7% (n = 5) patients underwent ablation along the left atrial appendage ostium, and 3.3% (n = 1) underwent Vein of Marshall alcohol ablation. There were 3 (10%) peri-procedural complications (1 access hematoma and two pericardial effusions requiring intervention-none related to left atrial appendage ostium or alcohol ablation). During the mean follow-up of 440 ± 379 days, 40% (n = 12) patients had AA recurrence (91.6% AF, 8.3% atrial tachycardia), of which five patients needed repeat ablation, and two patients were readmitted for heart failure. There was no stroke or any device-related complications, including new peri-device leaks or device-related thrombosis in patients who had follow-up imaging studies (n = 11, 36.7%). CONCLUSION: Catheter ablation for AF (including VoM alcohol ablation) in patients with prior LAAO devices is feasible and safe with favorable outcomes.
RESUMEN
INTRODUCTION: The QDOT MICROTM Ablation Catheter is a next-generation ablation catheter that allows for high-power ablation up to 90 watts. METHODS: We aimed to assess AE associated with the QDOT MICROTM catheter using the MAUDE database. A MAUDE database search was conducted on May 25, 2024, to capture all AEs (since FDA approval) associated with this ablation catheter. RESULTS: A total of 302 AEs from November 23, 2022, to April 30, 2024, were reported including 148 (49%) catheter-related issues and 154 (51%) clinical complications. Among the catheter-related issues, physical catheter damage (74.3%, n = 110) was most common, followed by communication or display issue (10.8%, n = 16), irrigation issue (9.5%, n = 14), signal issue or artifact (3.4%, n = 5), and inaccurate temperature measurement (2.0%, n = 3). Regarding clinical complications, the most common AE was pericardial effusion (43.5%, n = 67), followed by char formation (11.7%, n = 18), catheter thrombosis (7.1%, n = 11), stroke (7.1%, n = 11), pericarditis (7.1%, n = 11), esophageal complications (6.5%, n = 10), phrenic nerve palsy (3.9%, n = 6), cardiac arrest (3.9%, n = 6), significant AV block (3.9%, n = 6), pulmonary vein stenosis (3.2%, n = 5), coronary artery spasm (1.3%, n = 2), and pulmonary embolism (0.6%, n = 1). There were 11 deaths (five related to esophageal complications, five related to cardiac arrest, and one related to pericardial effusion with cardiac tamponade). CONCLUSION: As high-power ablation strategy with novel ablation catheters is becoming more widely utilized, operators must be aware of potential catheter-related issues and clinical complications that may arise. More data are needed to further evaluate risks of these complications to improve the catheter's safety and efficacy.
Asunto(s)
Ecocardiografía , Vena Cava Superior Izquierda Persistente , Humanos , Ecocardiografía/métodos , Vena Cava Superior Izquierda Persistente/diagnóstico por imagen , Vena Cava Superior Izquierda Persistente/complicaciones , Vena Cava Superior/anomalías , Vena Cava Superior/diagnóstico por imagenAsunto(s)
Ablación por Catéter , Humanos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Falla de Equipo , Irrigación Terapéutica/efectos adversos , Masculino , Diseño de Equipo , Catéteres Cardíacos/efectos adversos , Fibrilación Atrial/cirugía , Complicaciones Posoperatorias/etiologíaRESUMEN
INTRODUCTION: Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE: We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS: Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS: A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION: Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.
Asunto(s)
Desfibriladores Implantables , Campos Electromagnéticos , Marcapaso Artificial , Teléfono Inteligente , HumanosAsunto(s)
Anticoagulantes , Ablación por Catéter , Humanos , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Administración Oral , Femenino , Masculino , Resultado del Tratamiento , Taquicardia Ventricular/cirugía , Persona de Mediana EdadRESUMEN
Evidence regarding racial disparities in leadless pacemaker (LP) utilization and outcomes is limited. We aimed to explore ethnicity-based disparities in LP utilization and clinical outcomes of patients who underwent LP implantation. All consecutive patients who underwent LP between January 2019 and January 2023 at our institution were included. Charts were reviewed for baseline characteristics and clinical outcomes. The primary outcomes were procedure-related complications, cardiac rehospitalization, worsening heart failure (HF) or HF hospitalization, and all-cause mortality. All statistical analyses were performed using SPSS Statistics 22 (IBM Corp., Armonk, NY). The p <0.05 was considered statistically significant. A total of 196 adult patients underwent LP implantation during the study period (48% Caucasians, 36.2% Hispanic, 8.2% Asians, and 7.7% African-American). The groups were balanced with respect to baseline demographics, clinical characteristics, and procedure-related complications. During the median follow-up of 104 days (interquartile range 24 to 382), no statistically significant differences were observed in worsening HF or HF hospitalization or all-cause mortality among the ethnic groups. After multivariable logistic regression, Asian individuals had higher odds of cardiac readmissions (odds ratio 4.1, 95% confidence interval 1.4 to 12.3, p = 0.01). Patients from racial and ethnic minorities face significant inequities in arrhythmia care, including patients who have undergone LP implantation. Awareness and a system-based approach (understanding cultural preferences, effective application of evidence-based guidelines, and population-based policies) are crucial to lessen disparities in health care among minorities.
Asunto(s)
Etnicidad , Disparidades en Atención de Salud , Marcapaso Artificial , Grupos Raciales , Adulto , Humanos , Estados UnidosRESUMEN
BACKGROUND: Dual occlusive closure mechanism (disc and lobe type), Amulet device (Abbott; a second-generation device that has replaced Amplatzer Cardiac Plug) was approved by the Food and Drug Administration (FDA) in August 2021 for percutaneous left atrial appendage occlusion (LAAO). However, real-world safety data on the delivery system (Amplatzer Cardiac Plug and Amplatzer Amulet device) are lacking. OBJECTIVE: We sought to assess the type of adverse events associated with the Amplatzer LAAO delivery system using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: A MAUDE database search was conducted on March 31, 2023, for reports received between February 2013 and March 2023 to capture all adverse events. RESULTS: A total of 59 adverse events were reported, of which 58 were sheath-related events, and one was a wire-related event. The most commonly encountered issue was air embolism (19%, 11 events), followed by sheath thrombosis (13.8%, eight events, two of which were also associated with device thrombosis), kinked sheath (10.3%, six events), and sheath deformation (8.6%, five events). Patient-related adverse events included pericardial effusion requiring pericardiocentesis (22.4%, 13 events), vascular complications (20.7%, 12 events), and device dislodgement (5.2%, three events). CONCLUSION: LAAO-related adverse events are increasingly being reported using the Amplatzer LAAO delivery sheath. It is anticipated that improvements in device technology, the advent of steerable sheaths, and operator experience will minimize these complications.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Trombosis , Estados Unidos , Humanos , Apéndice Atrial/diagnóstico por imagen , United States Food and Drug Administration , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Trombosis/etiología , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversosRESUMEN
Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.
RESUMEN
BACKGROUND: Leadless pacemaker (LP) offers an innovative approach for treating bradyarrhythmia, thus avoiding pacemaker pocket and lead-related complications. The Food and Drug Administration (FDA) has recently approved the Aveir™ leadless pacing system (screw-in type LP). METHODS: We queried the FDA MAUDE database to study the safety profile and assess the types of complications with this relatively novel device technology. A MAUDE database search was conducted on January 20, 2023, for reports received post-FDA approval to capture all adverse events. RESULTS: A total of 98 medical device report were reported for Aveir™ LP. After excluding duplicate, programmer-related, or introducer-sheath-related entries (n = 34), 64 entries were included. The most commonly encountered problem was high threshold/noncapture (28.1%, 18 events), followed by stretched helix (17.2%, 11 events) and device dislodgement (15.6%, ten events-5 intraprocedural, while 5 in the postoperative Day 1). Other reported events included high impedance (14.1%, nine events), sensing issues (12.5%, eight events), bent/broken helix (7.8%, five events), premature separation (4.7%, three events), interrogation problem (3.1%, two events), low impedance (3.1%, two events), premature battery depletion (1.6%, one event) and inadvertent MRI mode switch (1.6%, one event) and miscellaneous (15.6%, n = 10). There were eight serious patient injury events-pericardial effusion requiring pericardiocentesis (7.8%, five events) due to cardiac perforation that resulted in two deaths (3.1%) followed by sustained ventricular arrhythmias (4.6%, n = 3). CONCLUSION: In our study assessing the real-world safety profile of the Aveir™ LP, serious adverse events have been reported-life-threatening ventricular arrhythmias, pericardial effusion, device explantation/reimplantation, and death.
Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Realidad Virtual , Estados Unidos , Humanos , United States Food and Drug Administration , Derrame Pericárdico/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Marcapaso Artificial/efectos adversosRESUMEN
BACKGROUND: Monomorphic ventricular tachycardia (VT) is rare in patients with hypertrophic cardiomyopathy (HCM), management of which is challenging. Limited data exists on the utility of catheter ablation for the treatment of VT in this population. OBJECTIVES: We aimed to assess clinical outcomes of catheter ablation for VT in HCM patients. METHODS: A systematic search, without language restriction, using PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov was performed. The meta-analysis was performed using a meta-package for R version 4.0/RStudio version 1.2 and Freeman Tukey double arcsine method to establish the variance of raw proportions. Outcomes measured included (1) acute procedure success (defined as noninducible for clinical VT), (2) freedom from VT at follow-up, (3) mortality. RESULTS: This systematic review of six studies (three from the United States and three from Japan) incorporated a total of 68 drug-refractory HCM patients who underwent VT radiofrequency catheter ablation (mean age 57.6 ± 13.3 years, mean LVEF 45.8 ± 15.4%, 85% men, maximum septal wall thickness 17.4 ± 4.6 mm, and 32.3% with an apical aneurysm). Acute procedural success was achieved in 84.5% patients (95% confidence interval [CI]: 70.6%-95.2%) with 27.9% patients had recurrent VT requiring multiple ablations (median 1, IQR 1-3). During the follow-up period (18.3 ± 11.7 months), the pooled incidence of freedom from recurrent VT after index procedure was 70.2% (95% CI: 51.9%-86.2%), while after the last ablation was 82.8% (95% CI: 57%-99.2%). There were two deaths during follow-up, one from heart failure and one from SCD 0.8% (95% CI: 0%-5.8%). CONCLUSION: The results of our pooled analysis demonstrated that catheter ablation for VT in HCM patients was associated with high acute procedural success, and reduced VT recurrence-findings comparable to previously published reports in other disease substrates.
Asunto(s)
Cardiomiopatía Hipertrófica , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Ventricular , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ablación por Catéter/métodos , Insuficiencia Cardíaca/etiología , Resultado del TratamientoRESUMEN
BACKGROUND: There has been increasing interest in physiologic pacing techniques that directly activate the specialized conduction system. We aimed to assess outcomes of conduction system pacing (CSP) in patients with prosthetic heart valves. METHODS: This systematic review was performed according to PRISMA guidelines. Freeman-Tukey double arcsine transformation with the random-effect model was used to summarize the data. Outcomes studied were 1) implant success (defined as ability to recruit the His-Purkinje system or the distal Purkinje system); (2) lead parameters at implant and follow-up; and (3) procedure-related complications. RESULTS: This systematic review of 7 studies included 267 unique patients in whom CSP was attempted with either HBP or LBBAP for pacing indications after a prosthetic valve. HBP was attempted in 38% (n = 108), while LBBAP in 62% (n = 175) patients. The overall success rate of CSP was 87%, while in patients post-TAVR, the overall success rate was 83.2%. In the subgroup analysis, LBBAP had a significant higher overall success rate compared to HBP (94.3% vs. 76.5%, p interaction = 0.02) and post-TAVR patients (94.3 vs. 66.9%, p interaction < 0.01), respectively. The LBBAP thresholds were significantly lower compared to HBP both at implant (0.67 ± 0.4 @ 0.44 ms vs. 1.35 ± 1 @ 0.85 ms, p interaction < 0.01) and at a mean follow-up of 12.4 ± 8 months (0.73 ± 0.1 @ 0.44 ms vs. 1.39 ± 1 @ 0.85 ms, p interaction < 0.01), respectively. CONCLUSION: CSP is safe and feasible in patients with a prosthetic valve, with a significantly higher success rate and superior lead parameters with LBBAP than HBP, especially in patients post-TAVR.
Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Válvulas Cardíacas , Resultado del TratamientoRESUMEN
Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (â¼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.
RESUMEN
Intracardiac echocardiography (ICE) has become an essential tool and is an integral part of percutaneous interventional and electrophysiology (EP) procedures. Intracardiac echocardiography offers real-time, high-quality, near-field evaluation of cardiac anatomy. Standard ICE imaging includes placing the catheter in the right atrium (RA), right ventricle (RV), or left atrium (LA, via the transeptal approach). Coronary sinus echocardiography (CSE) is another alternative, where the ICE catheter is positioned in the coronary sinus (CS). This approach offers better catheter stability and allows operators to visualize cardiac structure with particularly excellent views of the LA, LAA, left ventricle (LV), and mitral annulus. Additionally, CSE is an attractive alternative in cases with unfavorable interatrial septum or fossa ovalis anatomical features that could lead to difficulty advancing ICE catheter in left atrium. In this article focusing on CSE, we provide illustration-based guidance to help operators identify critical cardiac structures from CSE.