Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Cancer ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058728

RESUMEN

BACKGROUND: The authors report the prospective evaluation of reduced dose alkylator chemotherapy combined with radiotherapy for European Pediatric Soft Tissue Sarcoma Study Group (EpSSG) standard risk nonalveolar rhabdomyosarcoma (NA-RMS). PATIENTS AND METHODS: Localized node negative Intergroup Rhabdomyosarcoma Study (IRS) II/III NA-RMS at favorable sites (subgroup C), <25 years old, received five cycles of ifosfamide, vincristine, and dactinomycin (IVA) chemotherapy (30 g/m2 ifosfamide) and four cycles of vincristine and dactinomycin (if receiving radiotherapy), or nine cycles of IVA (54 g/m2 ifosfamide) ± radiotherapy. Delayed primary tumor excision was considered for IRS III tumors. The primary end points were event-free survival (EFS) and overall survival (OS). RESULTS: From October 2005 to December 2016, 359 evaluable patients were recruited: orbit, 164 (45.7%); head and neck nonparameningeal, 77 (21.4%); and genitourinary non-bladder/prostate, 118 (32.9%). EFS and OS were 77.4% (95% confidence interval [CI], 72.5-81.6) and 93.5% (95% CI, 90.1-95.8), respectively. Lower dose alkylator chemotherapy and radiotherapy achieved 5-year OS of 93.7% but the difference with higher dose alkylator chemotherapy +/- radiotherapy was not significant (p = 0.8003). Adjuvant radiotherapy improved EFS with 5-year estimates of 84.7% versus 65.2% for nonirradiated (p < .0001), but not OS (p = .9298). Omitting radiotherapy for orbital tumors reduced OS (5-year was 87.1% vs. 97.3% for irradiated, p = .0257). Following R0 resection (n = 60), radiotherapy did not significantly improve EFS or OS. CONCLUSIONS: Radiotherapy for local tumor control allows for reduction of cumulative dose of alkylators in EpSSG standard risk subgroup C RMS patients. The omission of radiotherapy did not affect OS in all patients except those with orbital RMS and was associated with inferior EFS.

2.
Audiol Res ; 14(2): 227-238, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38525682

RESUMEN

OBJECTIVES: The objectives were to present the real-time estimated values of cochlear implant (CI) electrode insertion speed (IS) during intraoperative sessions using the Cochlear Nucleus SmartNav System to assess whether this measure affected CI outcomes and to determine whether real-time feedback assists expert surgeons in achieving slow insertion. METHODS: The IS was measured in 52 consecutive patients (65 implanted ears) using the CI632 electrode. The IS values were analyzed in relation to procedure repetition over time, NRT ratio, and CI audiological outcomes. RESULTS: The average IS was 0.64 mm/s (SD = 0.24); minimum and maximum values were 0.23 and 1.24 mm/s, respectively. The IS significantly decreased with each array insertion by the operator (p = 0.006), and the mean decreased by 24% between the first and last third of procedures; however, this reduction fell within the error range of SmartNav for IS (+/-0.48 mm/s). No correlation was found between IS and the NRT ratio (p = 0.51), pure-tone audiometry (PTA) at CI activation (p = 0.506), and PTA (p = 0.94) or word recognition score (p = 0.231) at last evaluation. CONCLUSIONS: The estimated IS reported by SmartNav did not result in a clinically significant reduction in insertion speed or an improvement in CI hearing outcomes. Real-time feedback of IS could potentially be used for training, but its effectiveness requires confirmation through additional studies and more accurate tools. Implementation of IS assessment in clinical practice will enable comparisons between measurement techniques and between manual and robot-assisted insertions. This will help define the optimal IS range to achieve better cochlear implant (CI) outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...