Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Meat Sci ; 217: 109612, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39079411

RESUMEN

Pork carcasses were obtained from three abattoirs in Australia (n = 345) where technologies enabled collection of post slaughter measures of P2 fat depth (mm) (Hennessy Grading Probe (HGP), AutoFom III, PorkScan Lite) and estimates of carcass lean % (HGP, AutoFom III, PorkScan Plus). Computed tomography (CT) was used to scan carcasses and determine lean and fat %, with the strength of associations with abattoir measurement devices determined. The AutoFom III lean % demonstrated the strongest associations with whole carcass CT lean % (R2 0.63, RMSE 1.73) and fat % (R2 0.68, RMSE 1.80) and with section (fore, loin, belly and hind) CT composition. The association of P2 from AutoFom III was lower in comparison, however remained superior to other commercial devices (PorkScan Lite and HGP). Porkscan Plus lean % demonstrated moderate associations with whole carcass and section CT lean and fat %, with R2 values generally less than half those of the AutoFom III. The HGP demonstrated weakest associations with CT lean and fat % using either lean % or P2 outputs, which is likely related to data being collected from only the P2 measurement site. This is the first experiment to compare the strength of associations between multiple pork abattoir measurement devices and CT lean and fat % in Australia. P2 is the current industry standard for the assessment of lean yield in pork, however demonstrates weaker associations with carcass CT composition than devices capable of capturing multiple measures across the carcass like AutoFom III and PorkScan Plus.

2.
Meat Sci ; 214: 109517, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38696994

RESUMEN

The objective of the study was to independently validate a calibrated commercial handheld near infrared (NIR) spectroscopic device and test its repeatability over time using phenotypically diverse populations of Australian lamb. Validation testing in eight separate data sub-groups (n = 1591 carcasses overall) demonstrated that the NIR device had moderate precision (R2 = 0.4-0.64, RMSEP = 0.70-1.22%) but fluctuated in accuracy between experimental site demonstrated by variable slopes (0.50-0.94) and biases (-0.86-0.02). The repeatability experiment (n = 10 carcasses) showed that time to scan post quartering affected NIR measurement from 0 to 24 h (P < 0.001). On average, NIR IMF% was 0.97% lower (P < 0.001) at 24 h (4.01% ± 0.166), compared to 0 h. There was no difference (P > 0.05) between Time 0 and 1 h or Time 0 and 4 h or between replicate scans within each time point. This study demonstrated the SOMA NIR device could predict lamb chemical IMF% with moderate precision and accuracy, however additional work is required to understand how loin preparation, blooming and surface hydration affect NIR measurement.


Asunto(s)
Músculo Esquelético , Carne Roja , Oveja Doméstica , Espectroscopía Infrarroja Corta , Animales , Espectroscopía Infrarroja Corta/métodos , Espectroscopía Infrarroja Corta/instrumentación , Carne Roja/análisis , Australia , Músculo Esquelético/química , Reproducibilidad de los Resultados , Tejido Adiposo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...