Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Radiother Oncol ; 194: 110182, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38403024

RESUMEN

OBJECTIVE: This study aims to determine the added value of a geometrically accurate diffusion-weighted (DW-) MRI sequence on the accuracy of gross tumor volume (GTV) delineations, using pathological tumor delineations as a ground truth. METHODS: Sixteen patients with laryngeal or hypopharyngeal carcinoma were included. After total laryngectomy, the specimen was cut into slices. Photographs of these slices were stacked to create a 3D digital specimen reconstruction, which was registered to the in vivo imaging. The pathological tumor (tumorHE) was delineated on the specimen reconstruction. Six observers delineated all tumors twice: once with only anatomical MR imaging, and once (a few weeks later) when DW sequences were also provided. The majority voting delineation of session one (GTVMRI) and session two (GTVDW-MRI), as well as the clinical target volumes (CTVs), were compared to the tumorHE. RESULTS: The mean tumorHE volume was 11.1 cm3, compared to a mean GTVMRI volume of 18.5 cm3 and a mean GTVDW-MRI volume of 15.7 cm3. The median sensitivity (tumor coverage) was comparable between sessions: 0.93 (range: 0.61-0.99) for the GTVMRI and 0.91 (range: 0.53-1.00) for the GTVDW-MRI. The CTV volume also decreased when DWI was available, with a mean CTVMR of 47.1 cm3 and a mean CTVDW-MRI of 41.4 cm3. Complete tumor coverage was achieved in 15 and 14 tumors, respectively. CONCLUSION: GTV delineations based on anatomical MR imaging tend to overestimate the tumor volume. The availability of the geometrically accurate DW sequence reduces the GTV overestimation and thereby CTV volumes, while maintaining acceptable tumor coverage.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias Hipofaríngeas , Neoplasias Laríngeas , Humanos , Neoplasias Hipofaríngeas/diagnóstico por imagen , Neoplasias Hipofaríngeas/patología , Neoplasias Laríngeas/diagnóstico por imagen , Neoplasias Laríngeas/patología , Imagen de Difusión por Resonancia Magnética/métodos , Masculino , Anciano , Persona de Mediana Edad , Femenino , Carga Tumoral , Laringectomía
2.
Phys Imaging Radiat Oncol ; 29: 100532, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38317852

RESUMEN

Background and purpose: Individual elective lymph node irradiation instead of elective neck irradiation is a new concept for head-and-neck cancer (HNC) patients developed for the Magnetic Resonance Image guided linear accelerator (MR-linac). To prepare this, the detectability, volume changes and intra-fraction motion of elective lymph nodes on the MR-linac was assessed. Materials and methods: A total of 15 HNC patients underwent diagnostic pre-treatment MRI. Additionally, two MR-linac scans were obtained with a 10-minute time difference in the first week of radiation treatment. Elective lymph node contours inside lymph node levels (Ib-V) were segmented on the pre-treatment MRI and the MR-linac scans and compared on number and maximal transversal diameter. Intra-fraction motion of elective lymph nodes on the MR-linac was estimated using Center of Mass (COM) distances and incremental isotropic expansion of lymph node segmentations. Results: Of all 679 detected lymph nodes on the pre-treatment MRI, eight lymph nodes were not detectable on the first MR-linac scan and 16 new lymph nodes were detected. Lymph node diameters between the pre-treatment MRI scan and the MR-linac scan varied from -0.19 to + 0.13 mm. COM distances varied from 1.2 to 1.7 mm and lymph node contours had to be expanded with 3 mm. Conclusions: Nearly all elective lymph nodes were detectable on the 1.5T MR-linac scan with no major changes in target volumes compared to the pre-treatment MRI. Simulated intra-fraction motion during the MR-linac scans was smaller than the 5-mm margin that will be used in the first elective lymph node radiation treatment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...