Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Int J Angiol ; 28(1): 11-16, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30880885

RESUMEN

The abdominal viscera blood supply is derived from anterior branches of the abdominal aorta. Visceral artery aneurysms (VAAs) include aneurysms of the following arteries and their branches: the celiac artery, the hepatic artery, the splenic artery, the superior mesenteric artery, the inferior mesenteric artery, the pancreaticoduodenal artery, and the gastroduodenal artery. Overall VAAs comprise < 2% of all types of arterial aneurysms. Asymptomatic VAAs are now being encountered more frequently due to the widespread use of advanced diagnostic abdominal imaging. The incidental finding of a VAA frequently leaves clinicians with a dilemma as to the best course of management. The focus of this review is on current treatment options and management guidelines for both symptomatic and asymptomatic VAAs.

2.
Phys Rev Lett ; 117(5): 055301, 2016 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-27517776

RESUMEN

When an impurity is immersed in a Bose-Einstein condensate, impurity-boson interactions are expected to dress the impurity into a quasiparticle, the Bose polaron. We superimpose an ultracold atomic gas of ^{87}Rb with a much lower density gas of fermionic ^{40}K impurities. Through the use of a Feshbach resonance and radio-frequency spectroscopy, we characterize the energy, spectral width, and lifetime of the resultant polaron on both the attractive and the repulsive branches in the strongly interacting regime. The width of the polaron in the attractive branch is narrow compared to its binding energy, even as the two-body scattering length diverges.

3.
J Vasc Surg ; 54(5): 1478-80, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21723067

RESUMEN

A 56-year-old man with a family history of aortic aneurysm underwent routine repair in 2003. A postoperative computed tomography scan showed a 6-cm perigraft hygroma. Sudden onset of abdominal pain 12 months later revealed a larger hygroma, with an additional anterior fluid collection suggestive of contained rupture. The bilobed hygroma remained stable until 2010, when he presented with chills and severe abdominal pain. A computed tomography scan demonstrated free rupture of the sister hygroma, with air pockets observed within the sac. Conservative management was elected. Air pockets as well as the hygroma eventually resolved, and the patient remains well.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Linfangioma Quístico/etiología , Neoplasias Vasculares/etiología , Dolor Abdominal/etiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Descompresión Quirúrgica , Humanos , Linfangioma Quístico/diagnóstico por imagen , Linfangioma Quístico/cirugía , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Regresión Neoplásica Espontánea , Rotura Espontánea , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Neoplasias Vasculares/diagnóstico por imagen , Neoplasias Vasculares/cirugía
4.
Phys Rev E Stat Nonlin Soft Matter Phys ; 82(1 Pt 1): 011115, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20866573

RESUMEN

Free energies of dissipative media are reviewed. Then we use free-energy-optimal excitation and de-excitation fields to generate a dielectric's time-reversal spectrum, with several properties: a) The spectrum generalizes the time-reversal parity from "even" and "odd" of conservative systems to an interval [-1,+1] of "time-reversal eigenvalues" λ in dissipative media. b) It yields eigenmodes that are complete: any state of the medium is optimally excitable or de-excitable by them. c) These excitations are orthogonal with respect to the work function of the medium and, so, d) characterize field excitations for the given medium that, when superimposed, only do work on the medium, not on each other via the medium-field interaction mechanism. Notions of en masse potential and kinetic energy in the dissipative medium arise through even (λ=+1) and odd (λ=-1) parity, but also other energy notions via alternative parity (|λ|<1) under time reversal.

5.
J Clin Psychol Med Settings ; 16(1): 40-6, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19184375

RESUMEN

A growing body of research has demonstrated the effectiveness of integrating mental/behavioral healthcare with primary care in improving health outcomes. Despite this rich literature, such demonstration programs have proven difficult to maintain once research funding ends. Much of the discussion regarding maintenance of integrated care has been focused on lack of reimbursement. However, provider factors may be just as important, because integrated care systems require providers to adopt a very different role and operate very differently from traditional mental health practice. There is also great variability in definition and operationalization of integrated care. Provider concerns tend to focus on several factors, including a perceived loss of autonomy, discomfort with the hierarchical nature of medical care and primary care settings, and enduring beliefs about what constitutes "good" treatment. Providers may view integrated care models as delivering substandard care and passively or actively resist them. Dissemination of available data regarding effectiveness of these models is essential (e.g. timeliness of treatment, client satisfaction). Increasing exposure and training in these models, while maintaining the necessary training in traditional mental health care is a challenge for training at all levels, yet the challenge clearly opens new opportunities for psychology and psychiatry.


Asunto(s)
Prestación Integrada de Atención de Salud/economía , Prestación Integrada de Atención de Salud/organización & administración , Servicios de Salud Mental/economía , Servicios de Salud Mental/organización & administración , Medicina de la Conducta , Necesidades y Demandas de Servicios de Salud , Humanos , Medicina , Evaluación de Resultado en la Atención de Salud , Mecanismo de Reembolso/economía , Especialización , Estados Unidos
6.
Ann Vasc Surg ; 22(4): 534-40, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18538980

RESUMEN

We evaluated the safety of suprarenal aortic clamping in patients with abdominal aortic aneurysm (AAA) treated by open aortic replacement by retrospectively reviewing all patients who underwent elective AAA replacement at a university hospital from 1993 until 2003. We reviewed 249 patient charts and divided them into three groups according to the clamp location during aortic replacement: group 1, infrarenal clamp group (n = 185); group 2, suprarenal clamp group (n = 52); and group 3, supraceliac clamp group (n = 12). Groups 1 and 2 were compared with respect to risk factors, intraoperative events, and postoperative events. Statistical analysis was done using Wilcoxon's rank-sum test, chi-squared test, and Fisher's exact test. Risk factors were comparable in groups 1 and 2 except for weight, which was higher in group 1. Intraoperative urine output, hypotensive episodes, and use of renal protective drugs were comparable in the two groups. Operation time, blood loss, and use of IV fluids were all significantly higher in group 2, while total aortic clamp time was higher in group 1. Postoperative events were comparable except for postoperative peak creatinine, intensive care unit length of stay, and postoperative length of stay, which were higher in group 2; however, discharge creatinine was comparable without a significant difference. Suprarenal clamping is a safe method of aortic control during open AAA replacement surgery. The selection of clamping site should be individualized according to the intraoperative anatomy. Supraceliac clamping is not necessarily the preferable method of aortic control when the infrarenal location is not suitable for clamping.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Anciano , Implantación de Prótesis Vascular , Constricción , Femenino , Humanos , Complicaciones Intraoperatorias , Masculino , Insuficiencia Renal/etiología , Procedimientos Quirúrgicos Vasculares/efectos adversos
7.
Ann Vasc Surg ; 22(3): 346-57, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18411026

RESUMEN

We assessed the long-term patency of kissing stent reconstruction of the aortoiliac bifurcation and identified variables that may influence it. We retrospectively reviewed our experience with stent-reconstruction procedures of the aortoiliac bifurcation from January 1998 through June 2005. The impact of demographic variables, vascular risk factors, disease location and characteristics, stent material and design, and stenting configuration on stent patency was assessed using univariate and multivariate analysis. In particular, we evaluated the effect of geometric mismatch between the protruding segment of the stents and the distal aortic lumen. Sixty-six patients underwent aortobi-iliac stent reconstruction. Indications were bifurcation or bilateral proximal iliac disease in 52 patients and unilateral ostial disease requiring contralateral protection in 14 patients. Limited disease (TASC A and B) was present in 40 limbs in 19 patients; extensive/diffuse disease (TASC C and D) was present in 78 limbs in 47 patients. Complete occlusions were present in 37 limbs in 28 patients (bilateral in nine patients). Self-expanding stents were used in 56 procedures and balloon-expandable stents in 10. Crossing configuration was used in 43 procedures, while abutting configuration was used in 23 procedures. Technical success was achieved in 62 patients (94%), with all four failures due to inability to cross a chronically occluded limb. Three of these patients underwent aortomono-iliac stenting with a crossover femoral-femoral bypass graft, with the remaining one opting for no further interventions. Median combined follow-up was 37 +/- 27 months (range 0-102). Hemodynamically significant restenosis developed in nine patients (14%). The management of restenosis was endovascular in eight patients and was successful in all (balloon dilation in four, restenting in three, thrombolysis and stenting in one) and operative in one patient who developed aortic occlusion and underwent aortobifemoral grafting. Survival table analysis showed primary and assisted patency rates at 4 years of 81% and 94%, respectively. The mortality rate during follow-up was 19 (cardiac cause in eight, pulmonary cause in three, and malignancy in five). Univariate analysis showed radial mismatch (aortic lumen dead space around the protruding segment of the stents), female gender, prior occlusion, and residual stenosis to be significant predictors of restenosis. Multivariate logistic regression analysis showed radial mismatch to be the only significant determinant of restenosis, although the statistical power of the model was limited by the small number of restenoses. Stent reconstruction of the aortoiliac bifurcation for occlusive disease is effective and durable, even with complex aortoiliac disease and long segment occlusions. Most restenoses are amenable to endovascular treatment, with excellent long-term assisted patency. Geometric variables related to individual aortic anatomy and disease pattern (patient-dependent) and stenting configuration (operator-dependent) may have an impact on long-term patency.


Asunto(s)
Angioplastia/instrumentación , Aorta/cirugía , Enfermedades de la Aorta/cirugía , Arteriopatías Oclusivas/cirugía , Arteria Ilíaca/cirugía , Stents , Anciano , Anciano de 80 o más Años , Angioplastia/efectos adversos , Aorta/patología , Aorta/fisiopatología , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/mortalidad , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/mortalidad , Arteriopatías Oclusivas/fisiopatología , Constricción Patológica , Femenino , Estudios de Seguimiento , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Diseño de Prótesis , Radiografía , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
8.
Nat Biotechnol ; 24(9): 1151-61, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16964229

RESUMEN

Over the last decade, the introduction of microarray technology has had a profound impact on gene expression research. The publication of studies with dissimilar or altogether contradictory results, obtained using different microarray platforms to analyze identical RNA samples, has raised concerns about the reliability of this technology. The MicroArray Quality Control (MAQC) project was initiated to address these concerns, as well as other performance and data analysis issues. Expression data on four titration pools from two distinct reference RNA samples were generated at multiple test sites using a variety of microarray-based and alternative technology platforms. Here we describe the experimental design and probe mapping efforts behind the MAQC project. We show intraplatform consistency across test sites as well as a high level of interplatform concordance in terms of genes identified as differentially expressed. This study provides a resource that represents an important first step toward establishing a framework for the use of microarrays in clinical and regulatory settings.


Asunto(s)
Perfilación de la Expresión Génica/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Garantía de la Calidad de Atención de Salud/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Perfilación de la Expresión Génica/métodos , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
9.
Ann R Coll Surg Engl ; 86(2): 99-103, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15005927

RESUMEN

INTRODUCTION: Untreated malignant large bowel obstruction is rapidly fatal. Short-term palliation of symptoms can be achieved by formation of a stoma in those patients for whom resection surgery is inappropriate. In the final months of life, a stoma represents a significant burden for both patients and carers. Palliative endoluminal stenting may therefore be an attractive alternative option for this poor prognostic group. PATIENTS: Thirty-six patients were studied of whom 18 had obstructing left-sided colon cancer relieved by placement of endoluminal stents. These were compared with 18 historical controls with similar clinicopathological features that were treated more conventionally with palliative stoma formation in the same hospital. RESULTS: Patients in the two groups had similar sex distribution (P = 0.5); however, patients undergoing palliative stoma formation were significantly younger than patients being stented (P = 0.0065). As well as being older, there was a trend towards greater co-morbidities, stent patients having higher ASA grades (P = 0.01). Both groups of patients gained relief of obstructive symptoms. There were no differences in survival (P = 0.5) or in hospital mortality (2 in each group). The median length of palliation is 92 days (42-infinity days) for stenting and 121 days (89-281 days) for palliative stoma formation. Formation of a stoma required a significantly longer stay in ITU (P = 0.003) but total hospital stay was similar. CONCLUSIONS: As an alternative to palliative surgery, selected patients benefit from colonic endoluminal stenting with relief of obstructive symptoms and no adverse effect on survival. They may be spared the potential problems associated with palliative stoma formation and the morbidity of surgery. Stenting can be offered to the very frail patient who would otherwise be managed conservatively.


Asunto(s)
Neoplasias del Colon/cirugía , Obstrucción Intestinal/cirugía , Cuidados Paliativos/métodos , Anciano , Anciano de 80 o más Años , Neoplasias del Colon/complicaciones , Cuidados Críticos , Femenino , Humanos , Obstrucción Intestinal/etiología , Tiempo de Internación , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Derivación y Consulta , Stents , Análisis de Supervivencia
10.
J Vasc Surg ; 39(2): 421-6, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14743147

RESUMEN

PURPOSE: The purpose of this study was to evaluate the role of balloon angioplasty in the treatment of failing infrainguinal vein bypass (IVB) grafts. METHODS: A retrospective chart review of patients undergoing revision of a failing IVB graft by vascular surgeons at a tertiary care center from 1990 to 2001 was performed. Failing bypass grafts were identified by routine duplex scan surveillance and physical examination. The criteria for endovascular intervention varied on the basis of surgeon preferences and time period; factors considered when choosing balloon angioplasty included significant comorbidities that precluded operative intervention, the lack of adequate conduit for surgical revision, or poor accessibility of the stenotic lesion. Data recorded included demographic patient data, type of IVB graft, patency status, further procedures performed, and all complications and mortalities. Cumulative primary and assisted patency rates were calculated by using Kaplan-Meier life-table analysis. RESULTS: A total of 45 balloon angioplasties were performed in 36 patients. There were 36 angioplasties of vein bypass grafts, and additional balloon angioplasties were performed on nine of these patients. Locations of IVB grafts included femoropopliteal (13 patients), femorodistal (13), and popliteal to distal (10). Initial success was achieved in 33 of 36 vein bypass grafts (91.7%). In these bypass grafts, the stenotic lesions were identified and treated at the proximal anastomosis (3 patients), mid-bypass graft (6 patients), and distal anastomosis (27 patients). Autogenous vein was used for all bypass grafts. Cumulative vein bypass graft (life-table analysis) primary patency rates (those free of occlusion or bypass graft threatening stenosis) were 74.2% at 6 months, 62.7% at 12 months, and 58.2% at 24 months. Repeat interventions included surgical thrombectomy with vein patch angioplasty or bypass graft revision, as well as repeat balloon angioplasty with or without thrombolysis. Cumulative assisted vein bypass graft patency rates (those free of occlusion or bypass graft threatening stenosis) were 87.0%, 83.2%, and 78.9% at 6, 12, and 24 months, respectively. Two patients (4%) developed thigh hematomas; no other procedure-related complications were noted, and there were no deaths in the perioperative period. CONCLUSION: Balloon angioplasty of failing infrainguinal vein bypass grafts can be successfully performed with a low rate of complications. Acceptable short-term patency can be achieved. This procedure should be considered as an initial option in failing IVB grafts.


Asunto(s)
Angioplastia de Balón , Prótesis Vascular , Oclusión de Injerto Vascular/terapia , Complicaciones Posoperatorias/terapia , Falla de Prótesis , Anciano , Derivación Arteriovenosa Quirúrgica , Implantación de Prótesis Vascular , Femenino , Humanos , Tablas de Vida , Masculino , Estudios Retrospectivos , Factores de Tiempo , Grado de Desobstrucción Vascular
11.
Vascular ; 12(6): 362-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15895759

RESUMEN

Lower extremity bypass procedures restore function and prevent amputation in many patients with severe peripheral arterial occlusive disease. The regular postoperative use of aspirin offers the dual benefit of extending bypass patency and patient survival. Previous trials of adjunctive oral anticoagulant therapy with warfarin have infrequently combined warfarin with aspirin. We hypothesized that the addition of oral anticoagulant therapy would further enhance the benefits of aspirin but may increase the risk of clinically important bleeding. Eligible patients (N = 831) scheduled for elective lower extremity arterial bypass surgery were randomized to receive either warfarin plus aspirin (WA) (n = 418) or aspirin alone (n = 413). At monthly intervals, the warfarin dose was adjusted to a target international normalized ratio (INR) of 1.4 to 2.8; both groups received aspirin (325 mg/d). The end point of major hemorrhagic events, defined as intracranial hemorrhage or bleeding that required intervention, is reported, and INR values and compliance with warfarin therapy are presented. Major hemorrhagic events occurred more frequently in the WA group (35 in the WA group vs 15 in the aspirin group; p = .02) during a mean follow-up of 38 months. In the WA group, an intracranial hemorrhage occurred in six patients (two had an INR > 3.0), of whom four died; one subdural hemorrhage occurred in the aspirin group. Transfusions and interventions for bleeding were more frequent in the WA group, as were minor bleeding events. Of the 8,946 INR determinations, 58% were in the target range, whereas a higher value occurred in 10% and a lower value in 32%. Compliance with warfarin was maintained in 65% of the patients after the first year of observation. In patients with elective lower extremity bypass procedures, the postoperative adjunctive use of warfarin with aspirin increased the risk of major hemorrhagic events. Most of these events occurred when the INR was in the target range.


Asunto(s)
Anticoagulantes/efectos adversos , Arteriopatías Oclusivas/cirugía , Enfermedades Vasculares Periféricas/cirugía , Hemorragia Posoperatoria/inducido químicamente , Warfarina/efectos adversos , Aspirina/uso terapéutico , Quimioterapia Combinada , Femenino , Oclusión de Injerto Vascular/prevención & control , Humanos , Relación Normalizada Internacional , Pierna/irrigación sanguínea , Masculino , Persona de Mediana Edad , Cooperación del Paciente , Estudios Prospectivos , Procedimientos Quirúrgicos Vasculares/métodos
12.
J. vasc. bras ; 2(4): 296-302, dez. 2003. tab
Artículo en Portugués | LILACS | ID: lil-358730

RESUMEN

Objetivo: Avaliar a condição anatômica e funcional da veia safena magna após ressecção parcial, proximal(região da coxa) e distal(região do tornozelo), para angioplastia carotídea, e verificar sua possível utilização em cirurgias arteriais.Método: Trinta e um pacientes foram submetidos à cirurgia da artéria carótida, utilizando-se patch de veia safena para fechamento da arteriotomia no Serviço de Cirurgia Vascular da Universidade de Iowa, Estados Unidos, entre julho de 1992 e janeiro de 1995.Vinte e seis pacientes tiveram ressecção parcial proximal da veia safena magna(grupo A) e cinco tiveram ressecção distal ( grupo B). A veia safena magna foi totalmente avaliada em ambos os membros inferiores através do eco-Doppler vascular, com medida dos diâmetros em cinco pontos: região inguinal, coxa, joelho, perna e tornozelo.Resultados: Não houve diferença estatisticamente significativa entre os dois grupos (A e B) quanto ao tamanho das incisões cirúrgicas, segmentos de veias pérvios, diâmetros mínimos e máximos. Apenas dois pacientes do grupo A(7,69 por cento) e um do grupo B(20 por cento) apresentaram perda de segmento residual da veia safena magna, sendo todos homens e com idade superior a 77 anos. Nenhum paciente apresentou segmento venoso pérvio com menos de 2mm de diâmetro ao eco-Doppler.Conclusões: A ressecção parcial da veia safena magna ao nível de coxa e tornozelo, a fim de ser utilizada para angioplastia carotídea, apresenta pequeno índice de perda residual (9,67 por cento). Sua utilização prévia não exclui seu uso em futuros procedimentos arteriais.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Vena Safena , Angioplastia , Endarterectomía Carotidea , Estudios de Seguimiento , Factores de Tiempo
13.
J Vasc Surg ; 38(4): 692-8, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14560214

RESUMEN

PURPOSE: To evaluate the safety and assess the role of endovascular therapy in a variety of conditions related to celiac and mesenteric vascular occlusive disease. Patients and methods Our retrospective study population included 25 consecutive patients (mean age, 66 years), in whom 28 procedures were performed on 26 stenosed or occluded mesenteric vessels (superior mesenteric artery [SMA] or celiac artery [CA]). Indications included chronic mesenteric ischemia (21 patients), including 2 patients who underwent stenting prior to a planned operative repair of a juxtamesenteric AAA. Three liver transplantation patients underwent stenting of an associated CA stenosis. One patient with a splenorenal bypass underwent stenting on an associated CA stenosis. The technical and clinical success rates and the incidence of complications were determined. Follow-up parameters included maintained patency on duplex sonography and sustained clinical benefit. The need for additional interventions was noted. RESULTS: All procedures but one were technically successful (96%). Major complications occurred in three patients (one transient contrast-induced nephrotoxicity and two pseudoaneurysms). Immediate clinical success was achieved in 22 patients (88%). The three clinical failures included two patients with an excellent angiographic outcome, but with single-vessel moderate severity disease. Survival table analysis of delayed clinical outcome showed primary and primary-assisted clinical benefits at 11 months of 85% and 91%, respectively. Primary and primary-assisted stent patencies, as assessed by duplex sonography and/or angiography, at 6 months were both 92%. Angiographically documented restenosis occurred in three patients. Restenosis in two patients with CA stents was due to extrinsic compression, and it was without symptoms in one patient and was treated satisfactorily by restenting in the other patient. Restenosis in one patient with an SMA stent was successfully treated by restenting. CONCLUSIONS: Our experience suggests a potential role for endovascular therapy of celiac and mesenteric arterial occlusive disease in a variety of clinical scenarios, with a low incidence of complications and a high technical success rate.


Asunto(s)
Arteria Celíaca/cirugía , Arterias Mesentéricas/cirugía , Oclusión Vascular Mesentérica/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia de Balón , Constricción Patológica/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Grado de Desobstrucción Vascular
14.
J Vasc Interv Radiol ; 13(7): 695-702, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12119328

RESUMEN

PURPOSE: The authors prospectively evaluated optimized multiphase high-resolution (HR) Gadolinium (Gd)-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and standard two-dimensional (2D) time-of-flight (TOF) MR angiography for their ability to delineate distal calf and pedal vessels. MATERIALS AND METHODS: Twelve patients (20 limbs) with limb-threatening peripheral arterial occlusive disease underwent HR Gd-enhanced and 2D TOF MR angiography to identify targets for distal bypass. Imaging of the region of the ankle and foot was performed on a 1.5 T system with a head coil. A standard 2D TOF MR angiography sequence was performed first. The HR Gd-enhanced MR angiography sequence was then performed after injection of 0.01-0.2 mmol/kg of gadodiamide, allowing the acquisition of multiple consecutive coronal partitions, each in 18-25 seconds. Two experienced angiographers independently analyzed both studies. Comparison with intraoperative conventional angiography was available in 10 limbs. RESULTS: HR Gd-enhanced MR angiography allowed significantly faster imaging time (P <.0001) and larger coverage area (P <.0001) than 2D TOF MR angiography. All segments seen on 2D TOF MR angiography were visualized on HR Gd MR angiography, and significantly more suitable targets were seen well on HR Gd-enhanced MR angiography than on 2D TOF MR angiography (mean targets per limb: 3.9 +/- 1.9 vs 2.6 +/- 1.5, respectively; P =.02). In addition, HR Gd-enhanced MR angiography allowed better visualization of the arcuate pedal branch than 2D TOF MR angiography (P <.0001). Excellent correlation was demonstrated between HR Gd-enhanced MR angiography and intraoperative angiography in 29 segments (binary similarity coefficient, 0.90). A significantly higher percentage of artifacts adversely affected image interpretation with 2D TOF MR angiography than with HR Gd-enhanced MR angiography (14 limbs vs five limbs, P <.001). Artifacts on HR Gd-enhanced MR angiography included suboptimal mask in two limbs, venous contamination in one patient (two limbs), and motion artifact in one limb, although the studies remained diagnostic in all cases. CONCLUSION: HR Gd-enhanced MR angiography identified more distal target vessels with greater confidence than 2D TOF MR angiography. Optimized HR Gd-enhanced MR angiography may replace 2D TOF MR angiography as the gold standard examination for evaluation of distal runoff.


Asunto(s)
Tobillo/irrigación sanguínea , Pie/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Distribución de Chi-Cuadrado , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/cirugía , Estudios Prospectivos , Radiografía , Estadísticas no Paramétricas
15.
Pain ; 19(1): 59-69, 1984 May.
Artículo en Inglés | MEDLINE | ID: mdl-6739114

RESUMEN

The Dartmouth Pain Questionnaire is presented as an adjunct to the McGill Pain Questionnaire. It adds assessment of 4 objective measurements (pain complaints, somatic interventions, impaired functioning, and remaining positive aspects of function) and 1 subjective measure (changes in self-esteem since onset of pain). The entire device fits on one piece of paper and patients easily learn to self-administer it. Standardization results show acceptable levels of reliability and validity.


Asunto(s)
Dolor/diagnóstico , Adulto , Enfermedad Crónica , Humanos , Masculino , Persona de Mediana Edad , Dolor/psicología , Personalidad , Autoimagen , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...