Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Neonatal Screen ; 9(2)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37367213

RESUMEN

Mucopolysaccharidosis type II (MPS-II, Hunter syndrome, OMIM:30990) is a lysosomal storage disorder (LSD) that results in iduronate 2-sulphatase (I2S) enzyme deficiency. MPS-II was added to the Recommended Uniform Screening Panel (RUSP) in August 2022; thus, there is an increased demand for multiplexing I2S into existing LSD screening assays. After incubation with LSD synthetic substrates, extracts are cleaned using liquid-liquid extraction with ethyl acetate or protein precipitation using acetonitrile (ACN). We investigated cold-induced water ACN phase separation (CIPS) to improve the combination of 6-plex and I2S extracts to create a 7-plex assay, and compared it to room temperature ACN and ethyl acetate liquid-liquid extraction. The extracts were dried and resuspended in the mobile phase, and then analyzed using an optimized 1.9 min injection-to-injection liquid chromatography method coupled with tandem mass spectrometry (LC-MS/MS). The combination of ACN and CIPS improved the detection for I2S products without significant detriment to other analytes, which is attributable to a more complete coagulation and separation of heme, proteins, and extracted residual salts. Using CIPS for sample cleanup in dried blood spots (DBS) appears to represent a promising and straightforward way of achieving cleaner sample extracts in a new 7-plex LSD screening panel.

2.
Clin Chem ; 69(5): 470-481, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36920064

RESUMEN

BACKGROUND: Classical homocystinuria (HCU) results from deficient cystathionine ß-synthase activity, causing elevated levels of Met and homocysteine (Hcy). Newborn screening (NBS) aims to identify HCU in pre-symptomatic newborns by assessing Met concentrations in first-tier screening. However, unlike Hcy, Met testing leads to a high number of false-positive and -negative results. Therefore, screening for Hcy directly in first-tier screening would be a better biomarker for use in NBS. METHODS: Dried blood spot (DBS) quality control and residual clinical specimens were used in analyses. Several reducing and maleimide reagents were investigated to aid in quantification of total Hcy (tHcy). The assay which was developed and validated was performed by flow injection analysis-tandem mass spectrometry (FIA-MS/MS). RESULTS: Interferents of tHcy measurement were identified, so selective derivatization of Hcy was employed. Using N-ethylmaleimide (NEM) to selectively derivatize Hcy allowed interferent-free quantification of tHcy by FIA-MS/MS in first-tier NBS. The combination of tris(2-carboxyethyl)phosphine (TCEP) and NEM yielded significantly less matrix effects compared to dithiothreitol (DTT) and NEM. Analysis of clinical specimens demonstrated that the method could distinguish between HCU-positive, presumptive normal newborns, and newborns receiving total parenteral nutrition. CONCLUSIONS: Here we present the first known validated method capable of screening tHcy in DBS during FIA-MS/S first-tier NBS.


Asunto(s)
Homocistinuria , Tamizaje Neonatal , Humanos , Recién Nacido , Tamizaje Neonatal/métodos , Espectrometría de Masas en Tándem/métodos , Homocistinuria/diagnóstico , Control de Calidad , Análisis de Inyección de Flujo , Homocisteína
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...