Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Adv Mater ; : e2402254, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38884948

RESUMEN

The transition-metal chalcogenides include some of the most important and ubiquitous families of 2D materials. They host an exceptional variety of electronic and collective states, which can in principle be readily tuned by combining different compounds in van der Waals heterostructures. Achieving this, however, presents a significant materials challenge. The highest quality heterostructures are usually fabricated by stacking layers exfoliated from bulk crystals, which - while producing excellent prototype devices - is time consuming, cannot be easily scaled, and can lead to significant complications for materials stability and contamination. Growth via the ultra-high vacuum deposition technique of molecular-beam epitaxy (MBE) should be a premier route for 2D heterostructure fabrication, but efforts to achieve this are complicated by non-uniform layer coverage, unfavorable growth morphologies, and the presence of significant rotational disorder of the grown epilayer. This work demonstrates a dramatic enhancement in the quality of MBE grown 2D materials by exploiting simultaneous deposition of a sacrificial species from an electron-beam evaporator during the growth. This approach dramatically enhances the nucleation of the desired epi-layer, in turn enabling the synthesis of large-area, uniform monolayers with enhanced quasiparticle lifetimes, and facilitating the growth of epitaxial van der Waals heterostructures.

2.
Nat Commun ; 15(1): 3354, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637529

RESUMEN

The discovery of Mn-Ca complex in photosystem II stimulates research of manganese-based catalysts for oxygen evolution reaction (OER). However, conventional chemical strategies face challenges in regulating the four electron-proton processes of OER. Herein, we investigate alpha-manganese dioxide (α-MnO2) with typical MnIV-O-MnIII-HxO motifs as a model for adjusting proton coupling. We reveal that pre-equilibrium proton-coupled redox transition provides an adjustable energy profile for OER, paving the way for in-situ enhancing proton coupling through a new "reagent"- external electric field. Based on the α-MnO2 single-nanowire device, gate voltage induces a 4-fold increase in OER current density at 1.7 V versus reversible hydrogen electrode. Moreover, the proof-of-principle external electric field-assisted flow cell for water splitting demonstrates a 34% increase in current density and a 44.7 mW/cm² increase in net output power. These findings indicate an in-depth understanding of the role of proton-incorporated redox transition and develop practical approach for high-efficiency electrocatalysis.

3.
Can J Anaesth ; 71(5): 650-670, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38600285

RESUMEN

PURPOSE: Echocardiographic strain analysis by speckle tracking allows assessment of myocardial deformation during the cardiac cycle. Its clinical applications have significantly expanded over the last two decades as a sensitive marker of myocardial dysfunction with important diagnostic and prognostic values. Strain analysis has the potential to become a routine part of the perioperative echocardiographic examination for most anesthesiologist-echocardiographers but its exact role in the perioperative setting is still being defined. CLINICAL FEATURES: This clinical report reviews the principles underlying strain analysis and describes its main clinical uses pertinent to the field of anesthesiology and perioperative medicine. Strain for assessment of left and right ventricular function as well as atrial strain is described. We also discuss the potential role of strain to aid in perioperative risk stratification, surgical patient selection in cardiac surgery, and guidance of anesthetic monitor choice and clinical decision-making in the perioperative period. CONCLUSION: Echocardiographic strain analysis is a powerful tool that allows seeing what conventional 2D imaging sometimes fails to reveal. It often provides pathophysiologic insight into various cardiac diseases at an early stage. Strain analysis is readily feasible and reproducible thanks to the use of highly automated software platforms. This technique shows promising potential to become a valuable tool in the arsenal of the anesthesiologist-echocardiographer and aid in perioperative risk-stratification and clinical decision-making.


RéSUMé: OBJECTIF: L'analyse échocardiographique de la déformation cardiaque (strain analysis) par suivi des marqueurs acoustiques (speckle-tracking) permet d'évaluer la déformation du myocarde au cours du cycle cardiaque. Ses applications cliniques se sont considérablement développées au cours des deux dernières décennies en tant que marqueur sensible du dysfonctionnement myocardique, avec des valeurs diagnostiques et pronostiques importantes. L'analyse de la déformation cardiaque a le potentiel de devenir une partie intégrante de l'examen échocardiographique périopératoire de routine pour la plupart des anesthésiologistes-échocardiographes, mais son rôle exact dans le cadre périopératoire est encore en cours de définition. CARACTéRISTIQUES CLINIQUES: Ce rapport clinique passe en revue les principes qui sous-tendent l'analyse de la déformation cardiaque et décrit ses principales utilisations cliniques pertinentes dans le domaine de l'anesthésiologie et de la médecine périopératoire. L'analyse de la déformation cardique pour l'évaluation de la fonction ventriculaire gauche et droite ainsi que de la déformation auriculaire sont décrites. Nous discutons également du rôle potentiel de l'analyse de la déformation cardiaque pour aider à la stratification du risque périopératoire, à la sélection des patients en chirurgie cardiaque, à l'orientation du choix des moniteurs anesthésiques, et à la prise de décision clinique en période périopératoire. CONCLUSION: L'analyse échocardiographique de la déformation cardiaque est un outil puissant qui permet de voir ce que l'imagerie 2D conventionnelle ne parvient parfois pas à révéler. Elle fournit souvent un aperçu physiopathologique de diverses maladies cardiaques à un stade précoce. L'analyse de la déformation cardiaque est facilement réalisable et reproductible grâce à l'utilisation de plateformes logicielles hautement automatisées. Cette technique est potentiellement prometteuse et pourrait devenir un outil précieux dans l'arsenal de l'anesthésiologiste-échocardiographe et aider à la stratification du risque périopératoire et à la prise de décision clinique.


Asunto(s)
Anestesiólogos , Procedimientos Quirúrgicos Cardíacos , Humanos , Ecocardiografía/métodos , Pronóstico
4.
Korean J Anesthesiol ; 76(4): 267-279, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36824043

RESUMEN

Off-pump coronary surgery requires mechanical cardiac displacement, which results in bi-ventricular systolic and diastolic dysfunction. Although transient, subsequent hemodynamic deterioration can be associated with poor prognosis and, in extreme cases, emergency conversion to on-pump surgery, which is associated with high morbidity and mortality. Thus, appropriate decision-making regarding whether the surgery can be proceeded based on objective hemodynamic targets is essential before coronary arteriotomy. For adequate hemodynamic management, avoiding myocardial oxygen supply-demand imbalance, which includes maintaining mean arterial pressure above 70 mmHg and preventing an increase in oxygen demand beyond the patient's coronary reserve, must be prioritized. Maintaining mixed venous oxygen saturation above 60%, which reflects the lower limit of adequate global oxygen supply-demand balance, is also essential. Above all, severe mechanical cardiac displacement incurring compressive syndromes, which cannot be overcome by adjusting major determinants of cardiac output, should be avoided. An uncompromising form of cardiac constraint can be ruled out as long as the central venous pressure is not equal to or greater than the pulmonary artery diastolic (or occlusion) pressure, as this would reflect tamponade physiology. In addition, transesophageal echocardiography should be conducted to rule out mechanical cardiac displacement-induced ventricular interdependence, dyskinesia, severe mitral regurgitation, and left ventricular outflow tract obstruction with or without systolic motion of the anterior leaflet of the mitral valve, which cannot be tolerated during grafting. Finally, the ascending aorta should be carefully inspected for gas bubbles to prevent hemodynamic collapse caused by a massive gas embolism obstructing the right coronary ostium.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Humanos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Hemodinámica/fisiología , Gasto Cardíaco , Ecocardiografía Transesofágica , Oxígeno
5.
ACS Appl Polym Mater ; 5(2): 1565-1576, 2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36817335

RESUMEN

The uses of pressure-sensitive adhesives (PSAs) are wide ranging, with applications including labels, tapes, and graphics. To achieve good adhesion, a PSA must exhibit a balance of viscous and elastic properties. Previous research has found that a thin, elastic surface layer on top of a softer, dissipative layer resulted in greater tack adhesion compared with the single layers. Superior properties were achieved through a bilayer obtained via successive depositions, which consume energy and time. To achieve a multilayered structure via a single deposition process, we have stratified mixtures of waterborne colloidal polymer particles with two different sizes: large poly(acrylate) adhesive particles (ca. 660 nm in diameter) and small poly(butyl acrylate) (pBA) particles (ca. 100 nm). We used two types of pBA within the particles: either viscoelastic pBA without an added cross-linker or elastic pBA with a fully cross-linked network. Stratified surface layers of deuterium-labeled pBA particles with thicknesses of at least 1 µm were found via elastic recoil detection and qualitatively verified via the analysis of surface topography. The extent of stratification increased with the evaporation rate; films that were dried slowest exhibited no stratification. This result is consistent with a model of diffusiophoresis. When the elastic, cross-linked pBA particles were stratified at the surface, the tack adhesion properties made a transition from brittle failure to tacky. For pBA without an added cross-linker, all adhesives showed fibrillation during debonding, but the extent of fibrillation increased when the films were stratified. These results demonstrate that the PSA structure can be controlled through the processing conditions to achieve enhanced properties. This research will aid the future development of layered or graded single-deposition PSAs with designed adhesive properties.

6.
Langmuir ; 38(41): 12689-12701, 2022 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-36194469

RESUMEN

The distribution of surfactants in waterborne colloidal polymer films is of significant interest for scientific understanding and defining surface properties in applications including pressure-sensitive adhesives and coatings. Because of negative effects on appearance, wetting, and adhesion, it is desirable to prevent surfactant accumulation at film surfaces. The effect of particle deformation on surfactant migration during film formation was previously investigated by Gromer et al. through simulations, but experimental investigations are lacking. Here, we study deuterium-labeled sodium dodecyl sulfate surfactant in a poly(butyl acrylate) latex model system. The particle deformability was varied via cross-linking of the intraparticle polymer chains by differing extents. The cross-linker concentration varied from 0 to 35 mol % in the copolymer, leading to a transition from viscoelastic to elastic. Ion beam analysis was used to probe the dry films and provide information on the near-surface depth distribution of surfactant. Films of nondeformable particles, containing the highest concentration of cross-linker, show no surfactant accumulation at the top surface. Films from particles partially deformed by capillary action show a distinct surfactant surface layer (ca. 150 nm thick). Films of coalesced particles, containing little or no cross-linker, show a very small amount of surfactant on the surface (ca. 20 nm thick). The observed results are explained by considering the effect of cross-linking on rubber elasticity and applying the viscous particle deformation model by Gromer et al. to elastically deformed particles. We find that partially deformed particles allow surfactant transport to the surface during film formation, whereas there is far less transport when skin formation acts as a barrier. With elastic particles, the surfactant is carried in the water phase as it falls beneath the surface of packed particles. The ability to exert control over surfactant distribution in waterborne colloidal films will aid in the design of new high-performance adhesives and coatings.

8.
JTCVS Open ; 8: 446-460, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36004190

RESUMEN

Background: A radial-to-femoral pressure gradient (RFPG) can occur in roughly one-third of cardiac surgical patients. Such a gradient has been associated with smaller stature and potentially smaller radial artery diameter. We hypothesized that preoperative radial artery diameter could be a predictor of RFPG. We also investigated the clinical impact of using a femoral versus a radial arterial catheter in terms of vasoactive support. Methods: Using ultrasound, we measured the bilateral radial artery diameters of 160 cardiac surgical patients. All arterial pressure values were continuously recorded. Significant RFPG was defined as ≥25 mm Hg in systolic and/or ≥10 mm Hg in mean arterial pressure. One hundred and forty-nine additional patients were used to validate the impact of our observations. Results: Using 78,013 pressure datapoints in 129 patients, 34.8% of patients had an RFPG with a mean duration of 54 ± 48 minutes. Patients with a radial artery diameter <1.8 mm were more likely to have an RFPG (n = 14 [48.3%] vs 12 [22.2%]; P = .042). Patients with only a radial catheter received more phenylephrine (P = .016) despite undergoing shorter and less complex procedures. In the validation cohort, similar observations were made, and patients with a radial artery catheter received a longer duration of vasoactive support in the intensive care unit. Conclusions: A significant RFPG occurs in one-third of cardiac surgical patients and in 48% of those with a radial artery diameter <1.8 mm. The use of a single radial arterial catheter instead of dual radial and femoral catheters was associated with greater vasopressor requirements in the operating room and in the intensive care unit. We do not recommend the use of a single radial artery catheter in cardiac surgery.

9.
J Cardiothorac Vasc Anesth ; 35(5): 1334-1340, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33376068

RESUMEN

OBJECTIVES: The aim of the present study was to describe a bicaval endovascular occlusion technique in minimally invasive tricuspid valve (TV) surgery in patients with previous cardiac surgery. DESIGN: Case series. SETTING: Single tertiary university center. PARTICIPANTS: The study comprised ten patients. INTERVENTIONS: Endovascular occlusion of vena cavae for minimally invasive TV redo surgery. MEASUREMENTS AND MAIN RESULTS: Between 2008 and 2017, ten patients with previous cardiac surgery underwent TV minimally invasive surgery (repair or replacement; isolated or with concomitant procedures) using the Coda balloon catheter (Cook Medical, Bloomington, IN) to occlude both vena cavae. Data were collected retrospectively from electronic medical records. Superior and inferior vena cava occlusion with Coda balloon catheters was successful with no complications. The drainage of the vena cavae was optimal with excellent surgical exposure. Cardiopulmonary bypass time was 131 ± 119 minutes, with 30% of patients undergoing aortic clamping (two with a Chitwood clamp, one with an endoaortic balloon). Intensive care unit length of stay was 3.9 ± 2.7 days, and the in-hospital mortality rate was 30%. CONCLUSION: Bicaval endovascular occlusion of vena cavae is a feasible and effective technique in patients with previous cardiac surgery who are undergoing a minimally invasive TV procedure. The high mortality rate is associated with the inherent risk of a redo surgery involving the TV.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Tricúspide , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
10.
J Anesth Analg Crit Care ; 1(1): 12, 2021 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37386580

RESUMEN

BACKGROUND: Left ventricular (LV) diastolic function (DF) may play an important role in predicting fluid responsiveness. However, few studies assessed the role of diastolic function in predicting fluid responsiveness. The aim of this pilot study was to assess whether parameters of right and left diastolic function assessed with transesophageal echocardiography, including the mitral E/e' ratio, is associated with fluid responsiveness among patients undergoing elective bypass graft surgery. We also sought to compare other methods of fluid responsiveness assessment, including echocardiographic and hemodynamic parameters, pulse pressure variation, and stroke volume variation (SVV) (arterial pulse contour analysis, Flotrac/Vigileo system). RESULTS: We prospectively studied seventy patients undergoing coronary artery bypass grafting (CABG) monitored with a radial arterial catheter, transesophageal echocardiography (TEE), and a pulmonary artery catheter (for cardiac output measurements), before and after the administration of 500 mL of crystalloid over 10 min after the anesthetic induction. Thirteen patients were excluded (total of 57 patients). Fluid responsiveness was defined as an increase in cardiac index of ≥ 15%. There were 21 responders (36.8%) and 36 non-responders (63.2%). No difference in baseline pulsed wave Doppler echocardiographic measurements of any components of the mitral, tricuspid, and pulmonary and hepatic venous flows were found between responders and non-responders. There was no difference in MV tissue Doppler measurements between responders and non-responders, including E/e' ratio (8.7 ± 4.1 vs. 8.5 ± 2.8 in responders vs. non-responders, P = 0.85). SVV was the only independent variable to predict an increase in cardiac index by multivariate analysis (P = 0.0208, OR = 1.196, 95% CI (1.028-1.393)). CONCLUSIONS: In this pilot study, we found that no parameters of right and left ventricular diastolic function were associated with fluid responsiveness in patients undergoing CABG. SVV was the most useful parameter to predict fluid responsiveness. TRIAL REGISTRATION: ClinicalTrials.gov , NCT02714244 . Registered 21 March 2016-retrospectively registered.

11.
J Cardiothorac Vasc Anesth ; 34(9): 2369-2374, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32014311

RESUMEN

OBJECTIVE: In vivo protamine titration (IVPT) is based on the observation of a plateau on the decay curve of the celite activated clotting times (ACTs) during protamine infusion for heparin reversal. The aim of the present study was to determine the optimal protamine/heparin ratio to reverse anticoagulation using IVPT curves. DESIGN: Prospective, randomized study. SETTING: Tertiary care university hospital. PARTICIPANTS: The study comprised 138 patients undergoing elective cardiac surgery requiring cardiopulmonary bypass. INTERVENTIONS: The control group was given a protamine infusion of 1.3 mg per 1 mg (100 U) of heparin over 21 minutes. ACT was measured every 3 minutes. In the test group, the protamine dose was prepared using the same ratio as for the control group, and ACT values were measured every 3 minutes until a plateau was reached (2 consecutive ACT values <160 s), at which time the protamine infusion was stopped. The protamine/heparin ratio, blood losses, transfusions, and heparin concentrations were recorded. RESULTS: The protamine dose was lower in the test group (456.00 ± 105.66 mg [control group] v 295.25 ± 100.60 mg [test group]; p < 0.0001). The mean protamine/heparin ratios were 1.30 ± 0.10 (control group) and 0.81 ± 0.22 (test group) (p < 0.0001). Heparin concentrations were greater in the test group 15 minutes (0.10 [0-0.2] U/mL v 0 [0-0.1] U/mL; p = < 0.0001) and 3 hours (0 [0-0.1] U/mL v 0 [0-0] U/mL; p = 0.0002) after protamine infusion. There was no difference in the blood losses and transfusion requirements. CONCLUSIONS: IVPT is safe and efficient in this low-risk population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Protaminas , Anticoagulantes , Puente Cardiopulmonar , Heparina , Antagonistas de Heparina , Humanos , Estudios Prospectivos , Tiempo de Coagulación de la Sangre Total
12.
J Cardiothorac Vasc Anesth ; 33(3): 651-660, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30683595

RESUMEN

OBJECTIVE: To report the authors' 12 years of experience with intratracheal milrinone administration and to assess the efficacy and limitations of intratracheal milrinone bolus administration for the treatment of unexpected acute right ventricular (RV) failure in patients undergoing cardiac surgery. DESIGN: Retrospective analysis. SETTING: Single-center university hospital. PARTICIPANTS: One hundred seventy-six patients (4.6%) undergoing on-pump cardiac surgery. INTERVENTIONS: Endotracheal tube administration of milrinone (5-mg bolus) after unexpected acute RV failure during separation from cardiopulmonary bypass (CPB) weaning. RV failure was defined as the simultaneous presence of all of the following criteria: (1) hemodynamic instability or difficult separation from CPB with associated elevated central venous pressure or abnormal RV pressure waveform, (2) >20% reduction of RV fractional area change from baseline evaluated by transesophageal echocardiography, and (3) anatomical visualization of impaired or absent RV wall motion by direct intraoperative visual inspection. MEASUREMENTS AND MAIN RESULTS: Intratracheal milrinone administration was found to improve RV failure in 109 patients (61.9%) whereas RV failure persisted in 67 patients (38.1%). Using a multiple logistic regression model, severely decreased left ventricular ejection fraction (<35% v >50%) (adjusted odds ratio [OR] 3.72; 95% confidence interval [CI] 1.2-11.3; p = 0.012), longer CPB time (adjusted OR 1.014; CI 1.01-1.02; p = 0.001) and elevated postoperative fluid balance (adjusted OR 1.39; CI 1.1-1.8; p = 0.02) were found to be significant predictors of persistent RV failure. CONCLUSION: Intratracheal instillation of milrinone was associated with clinical improvement of RV failure occurring during separation from CPB in almost two-thirds of patients. Factors limiting its therapeutic efficacy include severe left ventricular dysfunction, increased fluid balance, and long CPB time.


Asunto(s)
Puente Cardiopulmonar/tendencias , Cardiotónicos/administración & dosificación , Intubación Intratraqueal/tendencias , Milrinona/administración & dosificación , Disfunción Ventricular Derecha/tratamiento farmacológico , Disfunción Ventricular Derecha/cirugía , Enfermedad Aguda , Anciano , Ecocardiografía Transesofágica/tendencias , Femenino , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Disfunción Ventricular Derecha/diagnóstico por imagen
13.
J Cardiothorac Vasc Anesth ; 33(5): 1197-1204, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30655202

RESUMEN

OBJECTIVE: To compare myocardial protection with retrograde cardioplegia alone with antegrade and retrograde cardioplegia in minimally invasive mitral valve surgery (MIMS). DESIGN: Retrospective study. SETTING: Tertiary care university hospital. PARTICIPANTS: The authors studied 97 MIMS patients using retrograde cardioplegia alone and 118 MIMS patients using antegrade and retrograde cardioplegia. INTERVENTIONS: The data from patients admitted for MIMS using retrograde cardioplegia (MIMS retro) between 2009 to 2012 were compared with the data from patients undergoing MIMS with antegrade and retrograde cardioplegia (MIMS ante-retro) between 2006 and 2010 (control group). Cardioplegia in the MIMS retro group was delivered solely through an endovascular coronary sinus (CS) catheter positioned under echographic and fluoroscopic guidance. Antegrade and retrograde cardioplegia was used in the MIMS ante-retro group. Data regarding myocardial infarction (MI; creatine kinase Mb, troponin T, electrocardiogram), myocardial function, and hemodynamic stability were collected for comparison. MEASUREMENTS AND MAIN RESULTS: Adequate cardioplegia administration (CS pressure >30 mmHg and asystole) was attained in 74.2% of the patients with retrograde cardioplegia alone. In 23.7% of the patients, the addition of an antegrade cardioplegia was necessary. No difference was observed in the incidence of MI (0 MIMS retro v 1 for MIMS ante-retro, p = 0.3623), difficult separation from cardiopulmonary bypass, and postoperative malignant arrhythmia. No difference was found for maximal creatine kinase Mb (39.1 [28.0-49.1] v 37.9 [28.6-50.9]; p = 0.8299) and for maximal troponin T levels (0.39 [0.27-0.70] v 0.47 [0.32-0.79]; p = 0.1231) for MIMS retro and MIMS ante-retro, respectively. However, lactate levels in the MIMS retro group were significantly lower than in the MIMS ante-retro group (2.1 [1.4-3.05] v 2.4 [1.8-3.3], respectively; p = 0.0453). No difference was observed in duration of intensive care unit stay and death. MIMS retro patients had a shorter hospital stay (7.0 [6.0-8.0] v 8.0 [7.0-9.0] days; p = 0.0003). CONCLUSION: Retrograde cardioplegia administration alone provided comparable myocardial protection to antegrade and retrograde cardioplegia during MIMS, but was not sufficient to achieve asystole in one-fifth of patients.


Asunto(s)
Cateterismo Cardíaco/métodos , Seno Coronario/cirugía , Procedimientos Endovasculares/métodos , Paro Cardíaco Inducido/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/cirugía , Adulto , Anciano , Cateterismo Cardíaco/normas , Soluciones Cardiopléjicas/administración & dosificación , Terapia Combinada/métodos , Terapia Combinada/normas , Procedimientos Endovasculares/normas , Femenino , Paro Cardíaco Inducido/normas , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/normas , Estudios Retrospectivos
14.
J Cardiothorac Vasc Anesth ; 33(4): 1090-1104, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30269893

RESUMEN

Right ventricular (RV) dysfunction is a cause of increased morbidity and mortality in both cardiac surgery and noncardiac surgery and in the intensive care unit. Early diagnosis of this condition still poses a challenge. The diagnosis of RV dysfunction traditionally is based on a combination of echocardiography, hemodynamic measurements, and clinical symptoms. This review describes the method of using RV pressure waveform analysis to diagnose and grade the severity of RV dysfunction. The authors describe the technique, optimal use, and pitfalls of this method, which has been used at the Montreal Heart Institute since 2002, and review the current literature on this method. The RV pressure waveform is obtained using a pulmonary artery catheter with the capability of measuring RV pressure by connecting a pressure transducer to the pacemaker port. The authors describe how RV pressure waveform analysis can facilitate the diagnosis of systolic and diastolic RV dysfunction, the evaluation of RV-arterial coupling, and help diagnose RV outflow tract obstruction. RV pressure waveform analysis also can be used to guide pharmacologic treatment and fluid resuscitation strategies for RV dysfunction.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Monitoreo Intraoperatorio/métodos , Atención Perioperativa/métodos , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/fisiopatología , Presión Ventricular/fisiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Disfunción Ventricular Derecha/cirugía , Función Ventricular Derecha/fisiología
15.
J Cardiothorac Vasc Anesth ; 32(2): 692-698, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29217231

RESUMEN

OBJECTIVE: To identify risk factors associated with radial-to-femoral pressure gradient during cardiac surgery with cardiopulmonary bypass (CPB). DESIGN: This is a retrospective, observational study. SETTING: Single specialized cardiothoracic hospital in Montreal, Canada. PARTICIPANTS: Consecutive patients that underwent heart surgery with CPB between 2005 and 2015 (n = 435). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A radial-to-femoral pressure gradient occurred in 146 patients of the 435 patients (34%). Based on the 10,000 bootstrap samples, simple logistic regression models identified the 17 most commonly significant variables across the bootstrap runs. Using these variables, a backward multiple logistic model was performed on the original sample and identified the following independent variables: body surface area (m2) (odds ratio [OR] 0.08, 95% confidence interval [CI] 0.030-0.232), clamping time (minutes) (OR 1.01, 95% CI 1.007-1.018), fluid balance (for 1 liter) (OR 0.81, 95% CI 0.669-0.976), and preoperative hypertension (OR 1.801, 95% CI 1.131-2.868). CONCLUSION: A radial-to-femoral pressure gradient occurs in 34% of patients during cardiac surgery. Patients at risk seem to be of smaller stature, hypertensive, and undergo longer and more complex surgeries.


Asunto(s)
Presión Sanguínea/fisiología , Puente Cardiopulmonar/tendencias , Arteria Femoral/fisiología , Complicaciones Intraoperatorias/fisiopatología , Monitorización Neurofisiológica Intraoperatoria/métodos , Arteria Radial/fisiología , Anciano , Tamaño Corporal/fisiología , Puente Cardiopulmonar/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Hipertensión/diagnóstico por imagen , Hipertensión/epidemiología , Hipertensión/fisiopatología , Complicaciones Intraoperatorias/diagnóstico por imagen , Complicaciones Intraoperatorias/epidemiología , Masculino , Persona de Mediana Edad , Arteria Radial/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo
16.
J Cardiothorac Vasc Anesth ; 32(2): 656-663, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29217241

RESUMEN

OBJECTIVE: To compare antegrade and retrograde cardioplegia administration in minimally invasive mitral valve surgery (MIMS) and open mitral valve surgery (OMS) for myocardial protection. DESIGN: Retrospective study. SETTING: Tertiary care university hospital. PARTICIPANTS: The study comprised 118 patients undergoing MIMS and 118 patients undergoing OMS. INTERVENTIONS: The data of patients admitted for MIMS from 2006 to 2010 were reviewed. Patients undergoing isolated elective OMS from 2004 to 2006 were used as a control group. Cardioplegia in the MIMS group was delivered via the distal port of the endoaortic clamp and an endovascular coronary sinus catheter positioned using echographic and fluoroscopic guidance. Antegrade and retrograde cardioplegia were used in OMS. Data regarding myocardial infarction (MI) (creatine kinase [CK]-MB, troponin T, electrocardiography); myocardial function; and hemodynamic stability were collected. MEASUREMENTS AND MAIN RESULTS: There was no difference in the perioperative MI incidence between both groups (1 in each group, p = 0.96). No statistically significant difference was found for maximal CK-MB (35.9 µg/L [25.1-50.1] v 37.9 µg/L [28.6-50.9]; p = 0.31) or the number of patients with CK-MB levels >50 µg/L (29 v 33; p = 0.55) or CK-MB >100 µg/L (3 v 4; p = 0.70) between the OMS and MIMS groups. However, maximum troponin T levels in the MIMS group were significantly lower (0.47 µg/L [0.32-0.79] v 0.65 µg/L [0.45-0.94]; p = 0.0007). No difference in the incidence of difficult weaning from bypass and intra-aortic balloon pump use between the MIMS and OMS groups was found. CONCLUSIONS: Antegrade and retrograde cardioplegia administration during MIMS and OMS provided comparable myocardial protection.


Asunto(s)
Cateterismo Cardíaco/métodos , Paro Cardíaco Inducido/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias/prevención & control , Esternotomía/métodos , Adulto , Cateterismo Cardíaco/tendencias , Femenino , Paro Cardíaco Inducido/tendencias , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/tendencias , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Estudios Retrospectivos , Esternotomía/tendencias
17.
J Cardiothorac Vasc Anesth ; 31(5): 1611-1617, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28803773

RESUMEN

OBJECTIVE: The incidence of postoperative nonischemic seizures associated with the use of tranexamic acid (TXA) and the possibility of prevention with a low-dose regimen of TXA were evaluated. DESIGN: Retrospective study. SETTING: Tertiary care university hospital. PARTICIPANTS: A total of 12,195 patients who underwent cardiac surgical procedures under cardiopulmonary bypass (CPB) were evaluated. INTERVENTIONS: The files of every clinical seizure case diagnosed in the surgical intensive care unit between April 2006 and April 2014 were reviewed. Patients who experienced a postoperative seizure underwent a cerebral computed tomography scan to exclude an ischemic lesion. Dosage and type of antifibrinolytic used and surgery characteristics were retrieved from perfusion files. Low-dose TXA was defined as 1,000-mg bolus, 400-mg/h infusion, and 500 mg in CPB priming. High-dose TXA was defined as 30-mg/kg bolus, 15 mg/kg/h, and 2 mg/kg in CPB priming. RESULTS: No seizure was observed in the 886 patients who did not receive antifibrinolytics. A total of 98 clinical seizures (0.8%) were recorded in the intensive care unit, and ischemic cause was excluded in the majority of them after computed tomography scan results were reviewed (91 patients [93%]). Low-dose TXA was associated with fewer seizures than was high-dose TXA (46 of 7,452 cases [0.70%] v 34 of 2,190 cases [1.55%], respectively; p < 0.0001). Open-chamber cardiac surgery also was linked to a higher incidence of seizures compared with revascularization (80 of 6,662 [1.20%] and 11 of 5,533 [0.20%], respectively; p < 0.0001). CONCLUSIONS: Lower doses of TXA were associated with a lower incidence of nonischemic seizures compared with higher doses of the drug.


Asunto(s)
Antifibrinolíticos/administración & dosificación , Procedimientos Quirúrgicos Cardíacos/tendencias , Puente Cardiopulmonar/tendencias , Convulsiones/prevención & control , Ácido Tranexámico/administración & dosificación , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Convulsiones/diagnóstico por imagen , Convulsiones/etiología
18.
Turk J Anaesthesiol Reanim ; 45(6): 367-373, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29359077

RESUMEN

OBJECTIVE: Normative values of left ventricular (LV) end-diastolic area and diameter (EDA and EDD) for intraoperative transoesophageal echocardiography (TEE) have not been established. We aimed to define the ranges of LV EDA and EDD for intraoperative TEE examinations in patients undergoing coronary artery bypass graft (CABG) surgery. METHODS: A MEDLINE search for studies reporting LV EDA and EDD in CABG patients was performed. Individual-level dataset from 333 anaesthetised and mechanically ventilated patients with preserved LV function (study population) were received from 8 studies. EDA and calculated EDD values in the study population were compared with summary mean EDD values obtained by transthoracic echocardiography (TTE) in 2 studies of 500 awake patients with coronary artery disease (CAD). Further, the influence of prespecified factors on EDD was evaluated through a multivariate regression model. RESULTS: LV EDA and EDD values measured by TEE in anaesthetised CABG patients were 16.7±4.7 cm2 and 4.6±0.6 cm, respectively. EDD values measured by TEE in anaesthetised patients were 10% to 13% less those measured by TTE in 2 studies of awake patients (p<0.001). Body surface area, age and fractional area change but not sex were factors that affected LV EDD. CONCLUSION: LV EDD values measured by intraoperative TEE in anaesthetised and mechanically ventilated CABG patients were 10% to 13% less than those measured by TTE in awake CAD patients. This finding indicates that independent normative values specific for intraoperative TEE should be established for guiding intraoperative clinical decisions.

19.
Anesth Analg ; 122(3): 624-632, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26599795

RESUMEN

BACKGROUND: A central-to-radial arterial pressure gradient may occur after cardiopulmonary bypass (CPB), which, in some patients, may last for a prolonged time after CPB. Whenever there is a pressure gradient, the radial artery pressure measure may underestimate a more centrally measured systemic pressure, which may result in a misguided therapeutic strategy. It is clinically important to identify the risk factors that may predict the appearance of a central-to-radial pressure gradient, because more central sites of measurements might then be considered to monitor systemic arterial pressure in high-risk patients. The objective of this study was to assess preoperative and intraoperative risk factors for central-to-radial pressure gradient. METHODS: Seventy-three patients undergoing cardiac surgery using CPB were included in this prospective observational study. A significant central-to-radial arterial pressure gradient was defined as a difference of 25 mm Hg in systolic pressure or 10 mm Hg in mean arterial pressure for a minimum of 5 minutes. Preoperative data included demographics, presence of comorbidities, and medications. Intraoperative data included type of surgery, CPB and aortic clamping time, use of inotropic drugs, and vasodilators or vasopressors agents. The diameter of the radial and femoral artery was measured before the induction of anesthesia using B-mode ultrasonography. RESULTS: Thirty-three patients developed a central-to-radial arterial pressure gradient (45%). Patients with a significant pressure gradient had a smaller weight (71.0 ± 16.9 vs 79.3 ± 17.3 kg, P = 0.041), a smaller height (162.0 ± 9.6 vs 166.3 ± 8.6 cm, P = 0.047), a smaller radial artery diameter (0.24 ± 0.03 vs 0.29 ± 0.05 cm, P < 0.001), and were at a higher risk as determined by the Parsonnet score (30.3 ± 24.9 vs 17.0 ± 10.9, P = 0.007). In addition, a longer aortic clamping time (85.8 ± 51.0 vs 64.2 ± 29.3 minutes, P = 0.036), mitral and complex surgery (P = 0.007 and P = 0.017, respectively), and administration of vasopressin (P = 0.039) were identified as potential independent predictors of a central-to-radial pressure gradient. By using multivariate logistic regression analysis, the following independent risk factors were identified: Parsonnet score (odds ratio [OR], 1.076; 95% confidence interval [CI], 1.027-1.127, P = 0.002), aortic clamping time >90 minutes (OR, 8.521; 95% CI, 1.917-37.870, P = 0.005), and patient height (OR, 0.933, 95% CI, 0.876-0.993, P = 0.029). The relative risk (RR) estimates remained statistically significant for the Parsonnet score and the aortic clamping time ≥90 minutes (RR, 1.010; 95% CI, 1.003-1.018, P = 0.009 and RR, 2.253; 95% CI, 1.475-3.443, P < 0.001 respectively) while showing a trend for patient height (RR, 0.974; 95% CI, 0.948-1.001, P = 0.058). CONCLUSIONS: Central-to-radial gradients are common in cardiac surgery. The threshold for using a central site for blood pressure monitoring should be low in small, high-risk patients undergoing longer surgical interventions to avoid inappropriate administration of vasopressors and/or inotropic agents.


Asunto(s)
Presión Arterial , Procedimientos Quirúrgicos Cardíacos/métodos , Complicaciones Intraoperatorias/epidemiología , Arteria Radial/fisiopatología , Anciano , Puente Cardiopulmonar , Comorbilidad , Constricción , Interacciones Farmacológicas , Electrocardiografía , Femenino , Humanos , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/terapia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Vasoconstrictores/efectos adversos , Vasoconstrictores/uso terapéutico , Vasopresinas/efectos adversos , Vasopresinas/uso terapéutico
20.
J Cardiothorac Vasc Anesth ; 29(4): 836-44, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25976606

RESUMEN

OBJECTIVE: To assess if right ventricular (RV) dysfunction is associated with increased mortality after cardiac surgery. DESIGN: Post-hoc analysis of a single-center double-blind randomized controlled trial. SETTING: University hospital. PARTICIPANTS: A total of 120 patients undergoing simple or complex valvular surgery. INTERVENTIONS: Patients were randomized to receive intravenous amiodarone or placebo intraoperatively. As secondary analysis, patients were divided into those requiring or not requiring postoperative inotropic agents. MEASUREMENTS AND MAIN RESULTS: After cardiopulmonary bypass (CPB), there were significant increases in heart rate, cardiac index, systolic and mean arterial pressures, central venous pressure and pulmonary capillary wedge pressure with reduction in systemic vascular resistance (p<0.05). Right ventricular end-systolic area became larger in those without inotropes and tricuspid annular plane systolic excursion was reduced in all patients; mitral annular systolic velocities were higher in patients receiving inotropes. Both right- and left-sided Doppler signals were altered significantly after CPB, which may be attributed to increased filling pressure. Inotropic agents were required in 56 patients after CPB (47%). The use of inotropic agents was associated with increased left and right atrial velocities (p<0.05). There were no differences in postoperative complications between groups; however, the number of deaths at 6 years was increased in patients who received inotropes after CPB (p = 0.0247). CONCLUSIONS: The increases in right-sided dimensions after CPB are associated with reduction in RV function and increased biventricular filling pressure, suggesting worsening biventricular function and interventricular dependence. Inotropic medications were associated with unaltered RV dimensions and increased biatrial activity.


Asunto(s)
Puente Cardiopulmonar/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Anciano , Puente Cardiopulmonar/tendencias , Método Doble Ciego , Femenino , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Ultrasonografía , Disfunción Ventricular Derecha/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...