Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Imaging ; 7(9)2021 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-34564111

RESUMEN

OBJECTIVES: To compare the conspicuity of lobular breast cancers at digital breast tomosynthesis (DBT) versus synthesized 2D mammography (synt2D). MATERIALS AND METHODS: Seventy-six women (mean age 61.2 years, range 50-74 years) submitted to biopsy in our institution, from 2019 to 2021, with proven invasive lobular breast cancer (ILC) were enrolled in this retrospective study. The participants underwent DBT and synt2D. Five breast radiologists, with different years of experience in breast imaging, independently assigned a conspicuity score (ordinal 6-point scale) to DBT and synt2D. Lesion conspicuity was compared, for each reader, between the synt2D overall conspicuity interpretation and DBT overall conspicuity interpretation using a Wilcoxon matched pairs test. RESULTS: A total of 50/78 (64%) cancers were detected on both synt2D and DBT by all the readers, while 28/78 (26%) cancers where not recognized by at least one reader on synt2D. For each reader, in comparison with synt2D, DBT increased significantly the conspicuity of ILC (p < 0.0001). The raw proportion of high versus low conspicuity by modality confirmed that cancers were more likely to have high conspicuity at DBT than synt2D. CONCLUSIONS: ILCs were more likely to have high conspicuity at DBT than at synt2D, increasing the chances of the detection of ILC breast cancer.

2.
Radiology ; 298(1): 49-57, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33170101

RESUMEN

Background Few results are available about subsequent outcomes after screening with digital breast tomosynthesis (DBT). Purpose To compare the diagnostic accuracy of a screening round with DBT plus synthetic mammography (SM) (hereafter, DBT+SM) and the repeat screening round with DBT with SM (hereafter, DBT+SM) or full-field digital mammography (FFDM) with FFDM screening. Materials and Methods This prospective study (Verona Pilot Study, clinical trial identification: 2015/1238) included women screened with DBT+SM between April 2015 and March 2017 and rescreened with DBT+SM or FFDM between April 2017 and March 2019. Screening performance (recall rate, cancer detection rate [CDR], and positive predictive value of recall [PPV1]) was compared with that obtained from 28 680 women screened with FFDM between 2013 and 2014 (control group). Cancer stages were compared between modalities and screening rounds. A χ2 test was used to evaluate differences. P < .05 was indicative of a statistically significant difference. Results Of 34 638 women enrolled, 32 870 (median age, 58 years; age range, 52-71 years) underwent repeat screening-16 198 with DBT+SM and 16 672 with FFDM. The CDR was higher for repeat screening with DBT+SM than for the control group with FFDM (8.1 per 1000 women screened vs 4.5 per 1000 women screened, respectively; P < .01) and was not significantly lower for repeat screening with FFDM (3.5 per 1000 women screened vs 4.5 per 1000 women screened, respectively; P = .11). Compared with the control group, there was no difference in the recall rate at repeat screening with both DBT+SM (3.71% vs 3.40%, respectively; P = .10) and FFDM (3.71% vs 3.69%, P = .92), whereas PPV1 was higher only when repeat screening was performed with DBT+SM (23.8% vs 12.0%, P < .01). At repeat screening, the proportion of cancers stage II or higher was 14.5% (19 of 131 cancers) with DBT+SM and 8.5% (five of 59 cancers) with FFDM, both of which were lower than the proportion in the control group with FFDM (30 of 110 cancers, 27.3%) (P ≤ .01). Conclusion At repeat screening, digital breast tomosynthesis plus synthetic mammography depicted more cancers than full-field digital mammography (FFDM) and found a lower number of stage II cancers compared with FFDM. © RSNA, 2020 See also the editorial by Bae in this issue.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Anciano , Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
Radiology ; 287(1): 37-46, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29237146

RESUMEN

Purpose To examine the outcomes of a breast cancer screening program based on digital breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography compared with those after full-field digital mammography (FFDM). Materials and Methods This prospective study included 16 666 asymptomatic women aged 50-69 years who were recruited in April 2015 through March 2016 for DBT plus synthetic 2D screening in the Verona screening program. A comparison cohort of women screened with FFDM (n = 14 423) in the previous year was included. Screening detection measures for the two groups were compared by calculating the proportions associated with each outcome, and the relative rates (RRs) were estimated with multivariate logistic regression. Results Cancer detection rate (CDR) for DBT plus synthetic 2D imaging was 9.30 per 1000 screening examinations versus 5.41 per 1000 screening examinations with FFDM (RR, 1.72; 95% confidence interval [CI]: 1.30, 2.29). CDR was significantly higher in patients screened with DBT plus synthetic 2D imaging than in those screened with FFDM among women classified as having low breast density (RR, 1.53; 95% CI: 1.13, 2.10) or high breast density (RR, 2.86; 95% CI: 1.42, 6.25). The positive predictive value (PPV) for recall was almost doubled with DBT plus synthetic 2D imaging: 23.3% versus 12.9% of recalled patients who were screened with FFDM (RR, 1.81; 95% CI: 1.34, 2.47). The recall rate was similar between groups (RR, 0.95; 95% CI: 0.84, 1.06), whereas the recall rate with invasive assessment was higher for DBT plus synthetic 2D imaging than for FFDM (RR, 1.93; 95% CI: 1.31, 2.03). The mean number of screening studies interpreted per hour was significantly lower for screening examinations performed with DBT plus synthetic 2D imaging (38.5 screens per hour) than with FFDM (60 screens per hour) (P < .001). Conclusion DBT plus synthetic 2D imaging increases CDRs with recall rates comparable to those of FFDM. DBT plus synthetic 2D imaging increased image reading time and the time needed for invasive assessments. © RSNA, 2017.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Tamizaje Masivo/métodos , Anciano , Mama/diagnóstico por imagen , Femenino , Humanos , Italia , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...