Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Infect Dis ; 75(Suppl 2): S254-S263, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-35684973

RESUMEN

BACKGROUND: Previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and coronavirus disease 2019 (COVID-19) vaccination, independently and combined ("hybrid immunity"), result in partial protection from subsequent infection and strong protection from severe disease. Proportions of the US population who have been infected, vaccinated, or have hybrid immunity remain unclear, posing a challenge for assessing effective pandemic mitigation strategies. METHODS: In this serial cross-sectional study, nationwide blood donor specimens collected during January-December 2021 were tested for anti-spike and anti-nucleocapsid antibodies, and donor COVID-19 vaccination history of ≥1 dose was collected. Monthly seroprevalence induced from SARS-CoV-2 infection, COVID-19 vaccination, or both, were estimated. Estimates were weighted to account for demographic differences from the general population and were compared temporally and by demographic factors. RESULTS: Overall, 1 123 855 blood samples were assayed. From January to December 2021, the weighted percentage of donations with seropositivity changed as follows: seropositivity due to vaccination without previous infection, increase from 3.5% (95% confidence interval, 3.4%-3.7%) to 64.0%, (63.5%-64.5%); seropositivity due to previous infection without vaccination, decrease from 15.6% (15.2%-16.0%) to 11.7% (11.4%-12.0%); and seropositivity due to hybrid immunity, increase from 0.7% (0.6%-0.7%) to 18.9% (18.5%-19.3%). Combined seroprevalence from infection, vaccination, or both increased from 19.8% (19.3%-20.2%) to 94.5% (93.5%-94.0%). Infection- and vaccination-induced antibody responses varied significantly by age, race-ethnicity, and region, but not by sex. CONCLUSIONS: Our results indicate substantial increases in population humoral immunity from SARS-CoV-2 infection, COVID-19 vaccination, and hybrid immunity during 2021. These findings are important to consider in future COVID-19 studies and long-term pandemic mitigation efforts.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Donantes de Sangre , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , Estudios Transversales , Humanos , Estudios Seroepidemiológicos , Vacunación
2.
Microbiol Spectr ; 10(3): e0247121, 2022 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-35612315

RESUMEN

Serological surveillance studies of infectious diseases provide population-level estimates of infection and antibody prevalence, generating crucial insight into population-level immunity, risk factors leading to infection, and effectiveness of public health measures. These studies traditionally rely on detection of pathogen-specific antibodies in samples derived from venipuncture, an expensive and logistically challenging aspect of serological surveillance. During the COVID-19 pandemic, guidelines implemented to prevent the spread of SARS-CoV-2 infection made collection of venous blood logistically difficult at a time when SARS-CoV-2 serosurveillance was urgently needed. Dried blood spots (DBS) have generated interest as an alternative to venous blood for SARS-CoV-2 serological applications due to their stability, low cost, and ease of collection; DBS samples can be self-generated via fingerprick by community members and mailed at ambient temperatures. Here, we detail the development of four DBS-based SARS-CoV-2 serological methods and demonstrate their implementation in a large serological survey of community members from 12 cities in the East Bay region of the San Francisco metropolitan area using at-home DBS collection. We find that DBS perform similarly to plasma/serum in enzyme-linked immunosorbent assays and commercial SARS-CoV-2 serological assays. In addition, we show that DBS samples can reliably detect antibody responses months postinfection and track antibody kinetics after vaccination. Implementation of DBS enabled collection of valuable serological data from our study population to investigate changes in seroprevalence over an 8-month period. Our work makes a strong argument for the implementation of DBS in serological studies, not just for SARS-CoV-2, but any situation where phlebotomy is inaccessible. IMPORTANCE Estimation of community-level antibody responses to SARS-CoV-2 from infection or vaccination is critical to inform public health responses. Traditional studies of antibodies rely on collection of blood via venipuncture, an invasive procedure not amenable to pandemic-related social-distancing measures. Dried blood spots (DBS) are an alternative to venipuncture, since they can be self-collected by study participants at home and do not require refrigeration for shipment or storage. However, DBS-based assays to measure antibody levels to SARS-CoV-2 have not been widely utilized. Here, we show that DBS are comparable to blood as a sampling method for antibody responses to SARS-CoV-2 infection and vaccination over time measured using four distinct serological assays. The DBS format enabled antibody surveillance in a longitudinal cohort where study participants self-collected samples, ensuring the participants' safety during an ongoing pandemic. Our work demonstrates that DBS are an excellent sampling method for measuring antibody responses whenever venipuncture is impractical.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , COVID-19/diagnóstico , COVID-19/epidemiología , Estudios Epidemiológicos , Humanos , Pandemias , SARS-CoV-2 , Estudios Seroepidemiológicos
3.
Transfusion ; 62(7): 1321-1333, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35607854

RESUMEN

BACKGROUND: A national serosurvey of U.S. blood donors conducted in partnership with the Centers for Disease Control and Prevention (CDC) was initiated to estimate the prevalence of SARS-CoV-2 infections and vaccinations. METHODS: Beginning in July 2020, the Nationwide Blood Donor Seroprevalence Study collaborated with multiple blood collection organizations, testing labs, and leadership from government partners to capture, test, and analyze approximately 150,000 blood donation specimens per month in a repeated, cross-sectional seroprevalence survey. RESULTS: A CDC website (https://covid.cdc.gov/covid-data-tracker/#nationwide-blood-donor-seroprevalence) provided stratified, population-level results to public health professionals and the general public. DISCUSSION: The study adapted operations as the pandemic evolved, changing specimen flow and testing algorithms, and collecting additional data elements in response to changing policies on universal blood donation screening and administration of SARS-CoV-2 spike-based vaccines. The national serosurvey demonstrated the utility of serosurveillance testing of residual blood donations and highlighted the role of the blood collection industry in public-private partnerships during a public health emergency.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , COVID-19/epidemiología , Estudios Transversales , Humanos , Pandemias , Estudios Seroepidemiológicos
4.
Transfusion ; 56(10): 2422-2425, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27739151

RESUMEN

BACKGROUND: Understanding the effect of delayed processing of whole blood on plasma ferritin will inform the feasibility of both routine ferritin testing in donors and clinical research study design. STUDY DESIGN AND METHODS: Whole blood tubes drawn from 16 donors were held at 4°C and centrifuged at 24-hour intervals to assess plasma ferritin concentration up to 5 days after draw. Intraindividual variation over time was measured in 21 healthy donors in blood samples collected weekly for 4 weeks and then at 12 weeks. RESULTS: No significant variation in plasma ferritin concentration was observed in blood stored at 4°C for up to 5 days after draw (p = 0.32). The estimated loss of 4.75% ferritin over 5 days was within the reported 5% variation of the assay. Moderate intraindividual variation occurs over time in both sexes, with variability increasing with the mean. No difference was detected between men and women in the regression of standard deviation on mean ferritin (p = 0.43). CONCLUSIONS: Ferritin is stable in whole blood up to 5 days, demonstrating operational feasibility of its use in monitoring donor iron stores. Moderate fluctuations over time occur, but ferritin measurements are sufficiently reliable to determine donor iron status on the day of donation.


Asunto(s)
Donantes de Sangre , Ferritinas/sangre , Control de Calidad , Adulto , Conservación de la Sangre/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Temperatura , Factores de Tiempo , Adulto Joven
5.
Transfusion ; 56(7): 1875-82, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27184253

RESUMEN

BACKGROUND: Babesia microti is the foremost infectious risk to the US blood supply for which a Food and Drug Administration (FDA)-licensed test is unavailable for donation screening. Characterization of the antibody response to B. microti and correlation with parasitemia is necessary to guide screening and donor management policies. STUDY DESIGN AND METHODS: During an FDA licensure trial, blood donors were prospectively screened (July-November 2013) using a B. microti-specific antibody enzyme immunoassay (EIA, Immunetics) in highly endemic (New York [NY]; n = 13,688), moderately endemic (Minnesota [MN]; n = 4583), and nonendemic (New Mexico [NM]; n = 8451) regions. Blood donors with repeat-reactive (RR) results participated in a 12-month prospective cohort study using B. microti EIA, immunofluorescent assay, polymerase chain reaction (PCR), blood smear, and clinical questionnaire. RESULTS: Thirty-seven (61.67%; 24 NY, seven MN, six NM) of 60 eligible RR donors enrolled in the study; 20 of 37 (54%) completed the 12-month follow-up visit of which 15 (75%) were still seroreactive. Nine PCR-positive donors were identified during index screening; five participated in the follow-up study, three were PCR positive at 6 months, and two remained positive at final follow-up (378 and 404 days). Most RR donors displayed low-level seroreactivity that was either stable or waning during follow-up. The level and pattern of reactivity correlated poorly with PCR positivity. CONCLUSION: The findings indicate prolonged seropositivity in blood donors. Although rare, asymptomatic, persistent PCR positivity supports the current policy of indefinite deferral for donors with a history of babesiosis or positive test results. Repeat testing by PCR and serology will be necessary if reinstatement is to be considered.


Asunto(s)
Babesiosis/diagnóstico , Donantes de Sangre , Tamizaje Masivo/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antiprotozoarios/sangre , Babesiosis/epidemiología , Estudios de Seguimiento , Humanos , Técnicas para Inmunoenzimas , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Estudios Prospectivos , Pruebas Serológicas , Adulto Joven
6.
Transfusion ; 56(7): 1866-74, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27224258

RESUMEN

BACKGROUND: The tick-borne pathogen Babesia microti has become recognized as the leading infectious risk associated with blood transfusion in the United States, yet no Food and Drug Administration-licensed screening tests are currently available to mitigate this risk. The aim of this study was to evaluate the performance of an investigational enzyme immunoassay (EIA) for B. microti as a screening test applied to endemic and nonendemic blood donor populations. STUDY DESIGN AND METHODS: The study aimed to test 20,000 blood donors from areas of the United States considered endemic for B. microti and 10,000 donors from a nonendemic area with the investigational B. microti EIA. Repeat-reactive samples were retested by polymerase chain reaction (PCR), blood smear, immunofluorescent assay (IFA), and immunoblot assay. In parallel, serum samples from symptomatic patients with confirmed babesiosis were tested by EIA, IFA, and immunoblot assays. RESULTS: A total of 38 of 13,757 (0.28%) of the donors from New York, 7 of 4583 (0.15%) from Minnesota, and 11 of 8363 (0.13%) from New Mexico were found repeat reactive by EIA. Nine of the 56 EIA repeat-reactive donors (eight from New York and one from Minnesota) were positive by PCR. The specificity of the assay in a nonendemic population was 99.93%. Among IFA-positive clinical babesiosis patients, the sensitivity of the assay was 91.1%. CONCLUSION: The B. microti EIA detected PCR-positive, potentially infectious blood donors in an endemic population and exhibited high specificity among uninfected and unexposed individuals. The EIA promises to provide an effective tool for blood donor screening for B. microti in a format amenable to high-throughput and cost-effective screening.


Asunto(s)
Babesia microti/aislamiento & purificación , Donantes de Sangre , Técnicas para Inmunoenzimas/métodos , Tamizaje Masivo/métodos , Pruebas Serológicas/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Babesiosis/sangre , Babesiosis/epidemiología , Enfermedades Endémicas , Femenino , Ensayos Analíticos de Alto Rendimiento , Humanos , Técnicas para Inmunoenzimas/normas , Masculino , Persona de Mediana Edad , Estados Unidos , Adulto Joven
7.
Transfusion ; 54(9): 2237-44, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24995863

RESUMEN

BACKGROUND: Transfusion-transmitted babesiosis caused by Babesia microti has emerged as a significant risk to the US blood supply. This study estimated the prevalence of B. microti antibodies in blood donors using an investigational enzyme immunoassay (EIA). STUDY DESIGN AND METHODS: A peptide-based EIA that detects both immunoglobulin (Ig)G and IgM antibodies to B. microti was developed and validated. Donor samples randomly selected from areas defined as high-risk endemic, lower-risk endemic, and nonendemic for B. microti were deidentified and tested using the investigational EIA. Samples that were EIA repeat reactive were further tested by B. microti immunofluorescent assay (IFA), polymerase chain reaction (PCR) on red blood cell lysates, and peripheral blood smear examination. A random subset of 1272 samples from high-risk endemic areas was tested by IFA, PCR, and peripheral blood smear in parallel with EIA. RESULTS: Among 15,000 donations tested with the investigational B. microti EIA, EIA repeat-reactive rates were 1.08% (54/5000) in a high-risk endemic area, 0.74% (37/5000) in a lower-risk area, and 0.40% (20/5000) in a nonendemic area. After application of a revised cutoff, these values were reduced to 0.92%, (46/5000), 0.54% (27/5000), and 0.16% (8/5000). Overall concordance between EIA and IFA among donor samples was 99.34%. One seropositive sample was positive by PCR. CONCLUSION: The seroprevalence of B. microti in blood donors in a high-risk area measured by an investigational EIA was approximately 1%. The EIA shows promise as an efficient high-throughput blood donor screening assay for B. microti.


Asunto(s)
Babesia microti/aislamiento & purificación , Babesiosis/sangre , Babesiosis/parasitología , Donantes de Sangre/estadística & datos numéricos , Técnicas para Inmunoenzimas/métodos , Anticuerpos Antiprotozoarios/sangre , Babesia microti/inmunología , Humanos , Estudios Seroepidemiológicos , Reacción a la Transfusión
8.
J Clin Virol ; 59(4): 223-7, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24529844

RESUMEN

BACKGROUND: Current diagnostic tests for Hepatitis C Virus (HCV) involve phlebotomy and serologic testing for HCV antibodies (anti-HCV) and RNA, which are not always feasible. Dried blood spots (DBS) present a minimally invasive sampling method and are suitable for sample collection, storage and testing. OBJECTIVES: To assess the utility of DBS in HCV detection, we evaluated the sensitivity and specificity of DBS for anti-HCV and HCV RNA detection compared to plasma specimens. STUDY DESIGN: This cross-sectional validation study was conducted in the context of an existing prospective study of HCV in young injection drug users. Blood samples were collected by venipuncture into serum separator tubes (SST) and via finger stick onto Whatman 903(®) protein-saver cards. Plasma samples and eluates from the DBS were tested for anti-HCV using either a third generation enzyme-linked or chemiluminescent immunoassay (IA), and HCV RNA using discriminatory HCV transcription-mediated amplification assay (dHCV TMA). DBS results were compared to their corresponding plasma sample results. RESULTS: 148 participants were tested for anti-HCV and 132 participants were tested for HCV RNA. For anti-HCV, the sensitivity of DBS was 70%, specificity was 100%, positive predictive value (PPV) was 100%, negative predictive value (NPV) was 76% and Kappa was 0.69. For HCV RNA, the sensitivity of DBS was 90%, specificity was 100%, PPV was 100%, NPV was 94% and Kappa was 0.92. CONCLUSIONS: DBS are sensitive and very specific in detecting anti-HCV and HCV RNA, demonstrate good correlation with plasma results, and have potential to facilitate diagnosis of HCV infection.


Asunto(s)
Desecación , Hepacivirus/aislamiento & purificación , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , ARN Viral/sangre , Manejo de Especímenes/métodos , Adulto , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Hepacivirus/genética , Hepacivirus/inmunología , Humanos , Masculino , Técnicas de Amplificación de Ácido Nucleico , Estudios Prospectivos , Sensibilidad y Especificidad , Adulto Joven
9.
Transfusion ; 53(6): 1302-8, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22998131

RESUMEN

BACKGROUND: In the United States, blood products are tested for infectious diseases including human T-lymphotropic virus (HTLV)-I/II. Positive results of maternal blood samples at the time of cord blood (CB) donation must be reported to mother and physician. Tests for HTLV have a high false-positive rate. This is problematic because there is no prenatal testing of the mother. STUDY DESIGN AND METHODS: This study involves 119,769 maternal blood samples at time of CB donation and evaluates positive results for HTLV in screening tests, supplemental immunoassays, and nucleic acid tests (NATs). Infectious disease markers (IDMs) and maternal health histories of HTLV-positive and -negative mothers were compared. RESULTS: Of 119,769 mothers donating CB, 545 tested positive with the screening test, 33 were positive with the supplemental tests, and two were positive with NAT. When indeterminate results were excluded from the supplemental test only six were positive. Eight of 34 mothers with positive or indeterminate supplemental test results had received intravenous immunoglobulin. There were no significant differences between HTLV-positive and -negative mothers with regard to the incidence of other IDMs. CONCLUSIONS: Testing maternal blood for HTLV is problematic for CB banks, obstetricians, and mothers because of the high false-positive rate. CB banks need rapid turnaround time and supplemental testing. If results on the latter are positive the obstetrician should be notified, educated, do follow-up testing, and counseling. Indeterminate results on supplemental tests are most likely false positives. We recommend that mothers with positive or indeterminate supplemental test results have follow-up NAT.


Asunto(s)
Seguridad de la Sangre/estadística & datos numéricos , Sangre Fetal/virología , Infecciones por HTLV-I , Infecciones por HTLV-II , Virus Linfotrópico T Tipo 1 Humano/aislamiento & purificación , Virus Linfotrópico T Tipo 2 Humano/aislamiento & purificación , Bancos de Sangre/estadística & datos numéricos , Anticuerpos Antideltaretrovirus/sangre , Reacciones Falso Positivas , Femenino , Infecciones por HTLV-I/sangre , Infecciones por HTLV-I/epidemiología , Infecciones por HTLV-I/transmisión , Infecciones por HTLV-II/sangre , Infecciones por HTLV-II/epidemiología , Infecciones por HTLV-II/transmisión , Humanos , Anamnesis , Embarazo , Diagnóstico Prenatal/estadística & datos numéricos , Prevalencia , Factores de Riesgo , Estudios Seroepidemiológicos , Estados Unidos/epidemiología
10.
Am J Epidemiol ; 167(6): 743-50, 2008 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-18203734

RESUMEN

Hospital-based studies suggest that hepatitis C virus (HCV) infection causes frequent cirrhosis, hepatocellular carcinoma, and mortality, but epidemiologic studies have shown less morbidity and mortality. The authors performed a retrospective cohort study of 10,259 recombinant immunoblot assay-confirmed, HCV antibody-positive (HCV+), allogeneic blood donors from 1991 to 2002 and 10,259 HCV antibody-negative (HCV-) donors matched for year of donation, age, gender, and Zone Improvement Plan Code (ZIP Code). Vital status through 2003 was obtained from the US National Death Index, and hazard ratios with 95% confidence intervals were calculated by survival analysis. After a mean follow-up of 7.7 years, there were 601 (2.92%) deaths: 453 HCV+ and 148 HCV- (hazard ratio (HR) = 3.13, 95% confidence interval (CI): 2.60, 3.76). Excess mortality in the HCV+ group was greatest in liver-related (HR = 45.99, 95% CI: 11.32, 186.74), drug- or alcohol-related (HR = 10.81, 95% CI: 4.68, 24.96), and trauma/suicide (HR = 2.99, 95% CI: 2.05, 4.36) causes. There was also an unexpected increase in cardiovascular mortality among the HCV+ donors (HR = 2.21, 95% CI: 1.41, 3.46). HCV infection is associated with a significant, threefold increase in overall mortality among former blood donors, including significantly increased mortality from liver and cardiovascular causes. High rates of mortality from drug/alcohol and trauma/suicide causes are likely due to lifestyle factors and may be at least partially preventable.


Asunto(s)
Donantes de Sangre , Cardiopatías/etiología , Hepatitis C/complicaciones , Hepatopatías/etiología , Adulto , Anciano , California/epidemiología , Femenino , Cardiopatías/mortalidad , Hepatitis C/epidemiología , Hepatitis C/mortalidad , Humanos , Hepatopatías/mortalidad , Masculino , Persona de Mediana Edad , Mortalidad , Estudios Retrospectivos , Riesgo , Estadísticas Vitales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...