Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Curr Glaucoma Pract ; 17(3): 134-140, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37920373

RESUMEN

Aims and background: As the use of minimally invasive or microinvasive glaucoma surgery (MIGS) continues to expand, it is important to look at its outcomes in the hands of trainees. This study aims to examine the efficacy and safety of Kahook Dual Blade (KDB) goniotomy and endocyclophotocoagulation (ECP) with cataract extraction (CE) done by residents and fellows. Methods: All cases of KDB or ECP performed with CE between 2012 and 2020 at Parkland were reviewed, excluding cases with multiple MIGS procedures or other procedures. Results: A total of 153 eyes of 136 patients who underwent KDB and 125 eyes of 124 patients who underwent ECP were included. Mean intraocular pressure (IOP) decreased from 17.2 ± 5.2 at baseline to 15.4 ± 5.5 mm Hg at postoperative (post-op) month (POM) 12 in the KDB group (p = 0.02) and from 18.6 ± 6.3 at baseline to 15.1 ± 4.9 mm Hg at POM12 in the ECP group (p < 0.001), with wide variation in IOP change among subjects for both. The mean change in IOP across all time points was statistically significant for both groups. Medication counts were reduced from baseline at POMs 1, 3, and 6, but not 12, in both the KDB and ECP groups (p = 0.43 and p = 0.35, respectively). The rate of serious complications was very low; the most common complication was cystoid macular edema (CME) (six cases) and active inflammation beyond POM1 (15 cases) for KDB and ECP, respectively. Conclusion: Combined CE/MIGS procedures performed by trainees were safe but less efficacious in lowering IOP and medications compared to literature reporting outcomes of attending surgeons, apart from ECP/MIGS with regards to IOP lowering, which was found to be similarly efficacious. Clinical significance: Cataract extraction (CE) combined with KDB or ECP in the hands of trainees decreased mean IOP from baseline and was safe. IOP and medication reduction of MIGS/CE in the hands of trainees were overall lesser than reported values by attending surgeons. How to cite this article: Da J, Gillings M, Kamat S, et al. Outcomes of Trainee-performed MIGS at Parkland Memorial Hospital: A Retrospective Cohort Study. J Curr Glaucoma Pract 2023;17(3):134-140.

3.
Am J Ophthalmol ; 227: 201-210, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33626362

RESUMEN

PURPOSE: To characterize and compare patient-reported recovery of function after cataract or glaucoma surgery using a novel visual analog scale. DESIGN: Prospective observational cohort study. METHODS: Daily for 2 weeks and weekly thereafter, patients recovering from trabeculectomy, tube shunt implantation, or cataract extraction (CE) completed a diary-style questionnaire including visual analog scales (VASs; scored 0-100) grading pain and global function. Clinical examination data and medical histories were collected. Generalized estimating equation models evaluated associations between VAS function scores and pain or visual acuity (VA) and compared scores between surgery types. RESULTS: Among 51 participants followed for 12 weeks, tube shunt placement reduced postoperative day 1 (POD1) function by 47 of 100 points vs CE (P = .006), while trabeculectomy did not reduce POD1 function vs CE (P = .33). After CE, trabeculectomy, and tube shunt placement, average VAS function scores increased 13.94 per week for 2 weeks (P < .001), 4.18 per week for 4 weeks (P = .02), and 7.76 per week for 7 weeks (P < .001), respectively. After those timepoints, there was no further significant change. Beyond 2 weeks, pain levels plateaued, and VA returned to baseline across surgery types; function was inversely related to pain or VA only for the first 2 or 4 weeks, respectively. CONCLUSIONS: Patients recovering from cataract and glaucoma surgery report reduced function in the postoperative period. Tube shunt implantation causes greater morbidity than trabeculectomy, and both are associated with slower improvement than CE. Early postoperative function is associated with VA and pain, but neither fully explains reported impairment. A VAS for function may efficiently capture postoperative recovery.


Asunto(s)
Implantes de Drenaje de Glaucoma , Presión Intraocular/fisiología , Facoemulsificación , Recuperación de la Función/fisiología , Trabeculectomía , Agudeza Visual/fisiología , Campos Visuales/fisiología , Anciano , Anciano de 80 o más Años , Catarata/fisiopatología , Femenino , Glaucoma/fisiopatología , Humanos , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Encuestas y Cuestionarios , Escala Visual Analógica
4.
Ophthalmology ; 127(2): 167-176, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31648802

RESUMEN

PURPOSE: To assess the impact of OCT signal strength (SS) and artifact on retinal nerve fiber layer (RNFL) measurement reliability and to understand whether glaucoma severity modifies this relationship. DESIGN: Retrospective, longitudinal cohort study. PARTICIPANTS: Two thousand nine hundred ninety-two OCT scans from 474 eyes of 241 patients with glaucoma or glaucoma suspect status. METHODS: We extracted mean RNFL thickness and SS and manually graded scans for artifact. To analyze the effect of SS and artifact on OCT reliability, we (1) created a multilevel linear model using measured RNFL thickness values and demographic and clinical data to estimate the true (predicted) RNFL thickness, (2) calculated model residuals (ΔRNFL) as our reliability measure, and (3) created a second multilevel linear model with splines and interaction terms that modeled overall and quadrant specific reliability (ΔRNFL) as the outcome, using SS and artifact as predictors. MAIN OUTCOME MEASURES: Impact of SS and artifact on ΔRNFL. RESULTS: For SS between 10 and 3, the impact of decreases in SS on OCT reliability is modest (-0.67 to -1.25 ΔRNFL per 1-point decrease in SS; P < 0.05). But at less than 3, changes in SS have a large impact on reliability (-15.70 to -16.34 ΔRNFL per 1-point decrease in SS; P < 0.05). At SS between 10 and 3, decreases in SS tend to have a larger impact on reliability in eyes with severe glaucoma (-1.25 per 1-point decrease in SS; P < 0.05) compared with eyes with mild or moderate glaucoma (-0.67 to -0.75 per 1-point decrease in SS; P < 0.05). The presence of artifact has a significant impact on OCT reliability independent of the effects of SS (-4.76 ΔRNFL; P < 0.05). Artifact affects reliability solely in the quadrant in which it occurs, with artifact in one quadrant showing no impact on ΔRNFL in the opposite quadrant (P > 0.05). CONCLUSIONS: Signal strength decreases down to 3 have relatively mild impacts on OCT reliability. At less than 3, the impact of further decreases in SS on reliability are substantial. The effect of SS on reliability is greater in severe glaucoma. Artifacts result in a decrease in reliability independent of the effect of SS. We propose evidence-based guidelines to guide physicians on whether to trust the results of an OCT scan.


Asunto(s)
Glaucoma/diagnóstico , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/normas , Adulto , Anciano , Medicina Basada en la Evidencia , Femenino , Humanos , Modelos Lineales , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos
5.
Mol Cancer Res ; 17(12): 2480-2491, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31611308

RESUMEN

A key hallmark of cancer, unlimited replication, requires cancer cells to evade both replicative senescence and potentially lethal chromosomal instability induced by telomere dysfunction. The majority of cancers overcome these critical barriers by upregulating telomerase, a telomere-specific reverse transcriptase. However, a subset of cancers maintains telomere lengths by the telomerase-independent Alternative Lengthening of Telomeres (ALT) pathway. The presence of ALT is strongly associated with recurrent cancer-specific somatic inactivating mutations in the ATRX-DAXX chromatin-remodeling complex. Here, we generate an ALT-positive adenocarcinoma cell line following functional inactivation of ATRX and telomerase in a telomerase-positive adenocarcinoma cell line. Inactivating mutations in ATRX were introduced using CRISPR-cas9 nickase into two prostate cancer cell lines, LAPC-4 (derived from a lymph node metastasis) and CWR22Rv1 (sourced from a xenograft established from a primary prostate cancer). In LAPC-4, but not CWR22Rv1, abolishing ATRX was sufficient to induce multiple ALT-associated hallmarks, including the presence of ALT-associated promyelocytic leukemia bodies (APB), extrachromosomal telomere C-circles, and dramatic telomere length heterogeneity. However, telomerase activity was still present in these ATRXKO cells. Telomerase activity was subsequently crippled in these LAPC-4 ATRXKO cells by introducing mutations in the TERC locus, the essential RNA component of telomerase. These LAPC-4 ATRXKO TERCmut cells continued to proliferate long-term and retained ALT-associated hallmarks, thereby demonstrating their reliance on the ALT mechanism for telomere maintenance. IMPLICATIONS: These prostate cancer cell line models provide a unique system to explore the distinct molecular alterations that occur upon induction of ALT, and may be useful tools to screen for ALT-specific therapies.


Asunto(s)
Neoplasias de la Próstata/genética , ARN/genética , Telomerasa/genética , Homeostasis del Telómero/genética , Proteína Nuclear Ligada al Cromosoma X/genética , Sistemas CRISPR-Cas/genética , Línea Celular Tumoral , Ensamble y Desensamble de Cromatina/genética , Inestabilidad Cromosómica/genética , Regulación Neoplásica de la Expresión Génica/genética , Técnicas de Inactivación de Genes , Humanos , Masculino , Mutación , Próstata/metabolismo , Próstata/patología , Neoplasias de la Próstata/patología , Telómero/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...