Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artif Intell Med ; 149: 102772, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38462273

RESUMEN

The current medical practice is more responsive rather than proactive, despite the widely recognized value of early disease detection, including improving the quality of care and reducing medical costs. One of the cornerstones of early disease detection is clinically actionable predictions, where predictions are expected to be accurate, stable, real-time and interpretable. As an example, we used stroke-associated pneumonia (SAP), setting up a transformer-encoder-based model that analyzes highly heterogeneous electronic health records in real-time. The model was proven accurate and stable on an independent test set. In addition, it issued at least one warning for 98.6 % of SAP patients, and on average, its alerts were ahead of physician diagnoses by 2.71 days. We applied Integrated Gradient to glean the model's reasoning process. Supplementing the risk scores, the model highlighted critical historical events on patients' trajectories, which were shown to have high clinical relevance.


Asunto(s)
Neumonía , Accidente Cerebrovascular , Humanos , Medición de Riesgo , Factores de Riesgo , Registros Electrónicos de Salud , Neumonía/diagnóstico , Neumonía/epidemiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología
2.
Sci Rep ; 11(1): 4145, 2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33603047

RESUMEN

The pandemic of Coronavirus Disease 2019 (COVID-19) is causing enormous loss of life globally. Prompt case identification is critical. The reference method is the real-time reverse transcription PCR (RT-PCR) assay, whose limitations may curb its prompt large-scale application. COVID-19 manifests with chest computed tomography (CT) abnormalities, some even before the onset of symptoms. We tested the hypothesis that the application of deep learning (DL) to 3D CT images could help identify COVID-19 infections. Using data from 920 COVID-19 and 1,073 non-COVID-19 pneumonia patients, we developed a modified DenseNet-264 model, COVIDNet, to classify CT images to either class. When tested on an independent set of 233 COVID-19 and 289 non-COVID-19 pneumonia patients, COVIDNet achieved an accuracy rate of 94.3% and an area under the curve of 0.98. As of March 23, 2020, the COVIDNet system had been used 11,966 times with a sensitivity of 91.12% and a specificity of 88.50% in six hospitals with PCR confirmation. Application of DL to CT images may improve both efficiency and capacity of case detection and long-term surveillance.


Asunto(s)
COVID-19/diagnóstico por imagen , COVID-19/diagnóstico , Tomografía Computarizada por Rayos X/métodos , COVID-19/epidemiología , COVID-19/metabolismo , China/epidemiología , Exactitud de los Datos , Aprendizaje Profundo , Humanos , Pulmón/patología , Neumonía/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...