Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Front Oncol ; 14: 1414337, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39286020

RESUMEN

The objective of this review is to examine the potential benefits and challenges of CT-based lung function imaging in radiotherapy over recent decades. This includes reviewing background information, defining related concepts, classifying and reviewing existing studies, and proposing directions for further investigation. The lung function imaging techniques reviewed herein encompass CT-based methods, specifically utilizing phase-resolved four-dimensional CT (4D-CT) or end-inspiratory and end-expiratory CT scans, to delineate distinct functional regions within the lungs. These methods extract crucial functional parameters, including lung volume and ventilation distribution, pivotal for assessing and characterizing the functional capacity of the lungs. CT-based lung ventilation imaging offers numerous advantages, notably in the realm of thoracic radiotherapy. By utilizing routine CT scans, additional radiation exposure and financial burdens on patients can be avoided. This imaging technique also enables the identification of different functional areas of the lung, which is crucial for minimizing radiation exposure to healthy lung tissue and predicting and detecting lung injury during treatment. In conclusion, CT-based lung function imaging holds significant promise for improving the effectiveness and safety of thoracic radiotherapy. Nevertheless, challenges persist, necessitating further research to address limitations and optimize clinical utilization. Overall, this review highlights the importance of CT-based lung function imaging as a valuable tool in radiotherapy planning and lung injury monitoring.

2.
Front Oncol ; 12: 1021119, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36465406

RESUMEN

Objective: Our study aims to estimate intra-fraction six-dimensional (6D) tumor motion with rotational correction and the related correlations between motions of different degrees of freedom (DoF), as well as quantify sufficient anisotropic clinical target volume (CTV) to planning target volume (PTV) margins during stereotactic body radiotherapy (SBRT) of liver cancer with fiducial tracking technique. Methods: A cohort of 12 patients who were implanted with 3 or 4 golden markers were included in this study, and 495 orthogonal kilovoltage (kV) pairs of images acquired during the first fraction were used to extract the spacial position of each golden marker. Translational and rotational motions of tumor were calculated based on the marker coordinates by using an iterative closest point (ICP) algorithm. Moreover, the Pearson product-moment correlation coefficients (r) were applied to quantify the correlations between motions with different degrees of freedom (DoFs). The population mean displacement ( M P ¯ ), systematic error (Σ) and random error (σ) were obtained to calculate PTV margins based on published recipes. Results: The mean translational variability of tumors were 0.56, 1.24 and 3.38 mm in the left-right (LR, X), anterior-posterior (AP, Y), and superior-inferior (SI, Z) directions, respectively. The average rotational angles θ X , θ Y and θ Z around the three coordinate axes were 0.88, 1.24 and 1.12, respectively. (|r|>0.4) was obtainted between Y -Z , Y - θ Z , Z -θ Z and θ X - θ Y . The PTV margins calculated based on 13 published recipes in X, Y, and Z directions were 1.08, 2.26 and 5.42 mm, and the 95% confidence interval (CI) of them were (0.88,1.28), (1.99,2.53) and (4.78,6.05), respectively. Conclusions: The maximum translational motion was in SI direction, and the largest correlation coefficient of Y-Z was obtained. We recommend margins of 2, 3 and 7 mm in LR, AP and SI directions, respectively.

3.
Front Oncol ; 12: 1015999, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36483053

RESUMEN

Objective: The aim is to investigate the influence of single planning (Plan S) and double plannings (Plan D) on bilateral lung cancer stereotactic body radiation therapy planning from the perspective of dosimetry and biology respectively. Methods Cases with bilateral lung cancer patients who had undergone SBRT with the Cyber-Knife were enrolled, and a single planning and double plannings were designed in the Multiplan@4.2 treatment planning system equipped with the Cyber-Knife system. The single plan was to optimize the two target volumes in a separate plan, while the dual plan is to optimize two target volumes respectively in two separate plans, then perform dose superposition. Then based on the dosimetric results, the biological parameters were calculated. Thus the quality of SBRT plans for those bilateral lung cancer designed by the two methods were compared and evaluated according to the dosimetric and biological results. Results: The dose distribution of both planning target volumes and surrounding organs at risk in Plan S and Plan D could meet the clinical prescription requirements. The target conformity index and the new conformity index of PTV were closer to 1 in the Double plannings, and the dose gradient GI in the Plan D was smaller than Plan S. For organs at risks, the doses received by the Plan D were relatively small. In terms of biological models, for the equivalent uniform dose of normal lung tissue, heart and esophagus, the Plan D was 6.51% (P=0.045), 19.8% (P=0.022), 27.08% (P>0.05) lower than Plan S respectively. The results showed that the equivalent uniform dose of normal tissue in the Plan D was lower relative to Plan S. Conclusions: Dosimetric and biological results show that both the use of Plan D have an advantage of protecting normal tissues, and it was suggested that to design double plannings for bilateral lung cancer stereotactic body radiation therapy planning based on Cyber-Knife in the clinical practice.

4.
Front Oncol ; 12: 992358, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36185221

RESUMEN

The application of metal nanoparticles (MNPs) as sensitization materials is a common strategy that is used to study dose enhancement in radiotherapy. Recent in vitro tests have revealed that magnetic gold nanoparticles (NPs) can be used in cancer therapy under a magnetic field to enhance the synergistic efficiency in radiotherapy and photothermal therapy. However, magnetic gold NPs have rarely been studied as sensitization materials. In this study, we obtained further results of the sensitization properties of the magnetic gold NPs (Fe3O4@AuNPs) with or without magnetic field using the TOPAS-nBio Monte Carlo (MC) toolkit. We analyzed the properties of Fe3O4@AuNP in a single NP model and in a cell model under monoenergetic photons and brachytherapy, and we investigated whether the magnetic field contributes to the physical sensitization process. Our results revealed that the dose enhancement factor (DEF) of Fe3O4@AuNPs was lower than that of gold nanoparticles (AuNPs) in a single NP and in a cell irradiated by monoenergetic photons. But it's worth mentioning that under a magnetic field, the DEF of targeted Fe3O4@AuNPs in a cell model with a clinical brachytherapy source was 22.17% (cytoplasm) and 6.89% (nucleus) higher than those of AuNPs (50 mg/mL). The Fe3O4@AuNPs were proved as an effective sensitization materials when combined with the magnetic field in MC simulation for the first time, which contributes to the research on in vitro tests on radiosensitization as well as clinical research in future.

5.
Front Oncol ; 12: 987971, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36147903

RESUMEN

Objective: The aim of this study was to investigate the impact of collimator angle optimization in single-isocenter coplanar volume modulated arc therapy (VMAT) stereotactic radiosurgery (SRS) for multiple metastases with respect to dosimetric quality and treatment delivery efficiency. In particular, this is achieved by a novel algorithm of sub-arc collimator angle optimization (SACAO). Methods: Twenty patients with multiple brain metastases were retrospectively included in this study. A multi-leaf collimator (MLC) conformity index (MCI) that is defined as the ratio of the area of target projection in the beam's eye view (BEV) to the related area fitted by MLC was applied. Accordingly, for each control point, 180 MCI values were calculated with a collimator angle interval of 1°. A two-dimensional heatmap of MCI as a function of control point and collimator angle for each full arc was generated. The optimal segmentation of sub-arcs was achieved by avoiding the worst MCI at each control point. Then, the optimal collimator angle for each sub-arc would be determined by maximizing the summation of MCI. Each patient was scheduled to undergo single-center coplanar VMAT SRS based on either the novel SACAO algorithm or the conventional VMAT with static collimator angle (ST-VMAT). The dosimetric parameters, field sizes, and the monitoring units (Mus) were evaluated. Results: The mean dose-volumetric parameters for the target volume of SACAO were comparable to ST-VMAT, while the conformity index (CI), homogeneity index (HI), and gradient index (GI) were reduced by SACAO. Improved sparing of organs at risk (OARs) was also obtained by SACAO. In particular, the SACAO method significantly (p < 0.01) reduced the field size (76.59 ± 32.55 vs. 131.95 ± 56.71 cm2) and MUs (655.35 ± 71.99 vs. 729.85 ± 73.52) by 41.11%. Conclusions: The SACAO method could be superior in improving the CI, HI, and GI of the targets as well as normal tissue sparing for multiple brain metastases SRS. In particular, SACAO has the potential of increasing treatment efficiency in terms of field size and MU.

6.
Technol Cancer Res Treat ; 21: 15330338221116494, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36114641

RESUMEN

Purpose: To identify the dosimetric predictors of lymphocytopenia and retrospectively analyze the changing trend of peripheral lymphocyte counts and lymphocyte-related inflammatory indicators in patients with simple pelvic radiotherapy. Methods and Materials: We retrospectively reviewed the clinical data of 188 patients with pelvic malignancies undergoing pelvic radiotherapy. The absolute count of neutrophils, lymphocytes, monocytes, and platelets at each time point was collected, and lymphocyte-related inflammation indicators were obtained, including neutrophil-to-lymphocyte ratio (NLR), lymphocyte-to-monocyte ratio (LMR), platelet-to-lymphocyte ratio (PLR), and the systemic immune-inflammation index (SII). The total pelvic bone (TPB) and the body within the 5 Gy coverage were retrospectively delineated for each patient. Dose-volume histograms corresponding to the delivered volumetric arc therapy plan were used to assess the dose volumes received by the TPB and body. A paired-samples t-test or Wilcoxon signed-rank test for matched pairs was applied for pairwise comparisons. We also established a stepwise multiple linear regression model for the peripheral lymphocyte count (PLC) value at the end of radiotherapy. Results: The PLC and lymphocyte-related inflammatory indicators changed significantly after the start of radiotherapy and persisted for 3-6 months after radiotherapy. The nadirs of PLC occurred at RT-End, and the PLC was still significantly lower than the baseline value at RT-3 months and RT-6 months. NLR, PLR, and SII at RT-End are about 3.5 times the value at RT-Baseline, while LMR is one-fourth of the basal value. In a further multiple stepwise linear regression analysis, the basal PLC (ß = 0.156, p ≤ .001), gender (ß = 0.096, p = .005), and TPB-V5 (ß = -0.016, p ≤ .001) turned out to be the predictor of the absolute value of lymphocytes at the end of radiotherapy. Conclusions: The impact of pelvic radiotherapy on PLC and lymphocyte-related inflammatory indicators is considerable and long-lasting. Minimizing pelvic bone radiation exposure dose (5 Gy) may help to avoid severe cases of lymphocytopenia.


Asunto(s)
Linfopenia , Neoplasias Pélvicas , Humanos , Inflamación/etiología , Inflamación/patología , Recuento de Linfocitos , Linfocitos/patología , Linfopenia/patología , Neoplasias Pélvicas/patología , Estudios Retrospectivos
7.
Radiat Oncol ; 17(1): 60, 2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346264

RESUMEN

PURPOSE: This study aimed at evaluating the clinical impact of full intensity-modulated radiotherapy (IMRT), hybrid IMRT (H-IMRT) and hybrid volumetric-modulated arc therapy (H-VMAT) for early-stage breast cancer with simultaneous integrated boost (SIB), in terms of plan quality and second cancer risk (SCR). METHODS: Three different plans were designed in full IMRT, hybrid IMRT, and hybrid VMAT for each of twenty patients with early-stage breast cancer. Target quality, organs at risk (OARs) sparing, and SCR were compared among the three plans for each case. RESULTS: In compared with H-IMRT, IMRT plans showed deterioration in terms of D2% of SIB, V10 of ipsilateral lung, and excess absolute risk (EAR) to contralateral lung (C-Lung) and esophagus. D2% and the homogeneity index (HI) of SIB, V5 of ipsilateral lung (I-Lung), the Dmean of the esophagus, the EAR to C-Lung and the esophagus with hybrid VMAT dramatically increased by 0.63%, 10%, 17.99%, 149.27%, 230.41%, and 135.29%, respectively (p = 0.024; 0.025; 0.046; 0.011; 0.000; 0.014). Dmean of the heart, the EAR to contralateral breast (C-Breast) and C-Lung by full IMRT was significantly decreased in comparison to the H-VMAT (4.67%, p = 0.033, 26.76%, p = 0.018; 48.05%, p = 0.036). CONCLUSION: The results confirmed that H-IMRT could achieve better target quality and OARs sparing than IMRT and H-VMAT for SIB radiotherapy of early-stage right breast cancer. H-IMRT was the best treatment option, while H-VMAT performed the worst among the three plans in terms of SCR to peripheral OARs.


Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Neoplasias de la Mama/radioterapia , Femenino , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
8.
Radiat Oncol ; 17(1): 1, 2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-34980178

RESUMEN

PURPOSE: To evaluate the sensitivity to set up the uncertainty of VMAT plans in Nasopharyngeal carcinoma (NPC) treatment by proposing a plan robustness evaluation method. METHODS: 10 patients were selected for this study. A 2-arc volumetric-modulated arc therapy (VMAT) plan was generated for each patient using Varian Eclipse (13.6 Version) treatment planning system (TPS). 5 uncertainty plans (U-plans) were recalculated based on the first 5 times set-up errors acquired from cone-beam computer tomography (CBCT). The dose differences of the original plan and perturbed plan corresponded to the plan robustness for the structure. Tumor control probability (TCP) and normal tissues complication probability (NTCP) were calculated for biological evaluation. RESULTS: The mean dose differences of D98% and D95% (ΔD98% and ΔD95%) of PTVp were respectively 3.30 Gy and 2.02 Gy. The ΔD98% and ΔD95% of CTVp were 1.12 Gy and 0.58 Gy. The ΔD98% and ΔD95% of CTVn were 1.39 Gy and 1.03 Gy, distinctively lower than those in PTVn (2.8 Gy and 2.0 Gy). The CTV-to-PTV margin increased the robustness of CTVs. The ΔD98% and ΔD95% of GTVp were 0.56 Gy and 0.33 Gy. GTVn exhibited strong robustness with little variation of D98% (0.64 Gy) and D95% (0.39 Gy). No marked mean dose variations of Dmean were seen. The mean reduction of TCP (ΔTCP) in GTVp and CTVp were respectively 0.4% and 0.3%. The mean ΔTCPs of GTVn and CTVn were 0.92% and 1.3% respectively. The CTV exhibited the largest ΔTCP (2.2%). In OARs, the brain stem exhibited weak robustness due to their locations in the vicinity of PTV. Bilateral parotid glands were sensitive to set-up uncertainty with a mean reduction of NTCP (ΔNTCP) of 6.17% (left) and 7.70% (right). The Dmax of optical nerves and lens varied slightly. CONCLUSION: VMAT plans had a strong sensitivity to set-up uncertainty in NPC radiotherapy, with increasing risk of underdose of tumor and overdose of vicinal OARs. We proposed an effective method to evaluate the plan robustness of VMAT plans. Plan robustness and complexity should be taken into account in photon radiotherapy.


Asunto(s)
Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Radioterapia de Intensidad Modulada/métodos , Incertidumbre , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
9.
Comput Methods Programs Biomed ; 209: 106338, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34390935

RESUMEN

PURPOSE: To evaluate the quality of robust stereotactic body proton therapy (RSBPT) plans generated by one-clicking scripting method for patients with lung cancer. MATERIALS AND METHODS: Retrospective analysis was performed on fifty lung cancer patients whose plan with robustly stereotactic body radiation therapy (SBRT). Thirty out of fifty patients were used for training to build a regression model, based on robust SBRT reference doses, to predict EUD values of ROIs for robust SBPT planning. Thereafter, robust SBPT plans with both automated EUD-Based mimicking (Automated Robust Proton ARP) and manual (Manual Robust Proton MRP) methods were evaluated in the remaining 20 patients. Plans were compared in terms of dosimetric parameters and planning time. RESULTS: A statistically significantly improvement in target dose fall off was observed for ARP plans compare to MRP plans (Dose fall off: 135 for MRP and 88 for ARP, p < 0.01), while no differences in target coverage and conformity. A statistically significantly reduce in normal lung tissue were observed for ARP plans compare to MRP plans (Lung [Dmean cGy (RBE)]: MRP: 478 vs. ARP: 351, p < 0.01; Lung [V5Gy (RBE) (%)]: MRP: 16.1 vs. ARP: 12.1, p < 0.01; Lung [V20Gy (RBE) (%)]: MRP: 8.5 vs. ARP: 6.8, p < 0.01). Planning time was reduced for ARP plans compare to MRP plans (optimization time: 12 min for MRP vs. 8 min for ARP; total plan time: 23 min for MRP vs. 18 min for ARP). CONCLUSION: The automated robust SBPT plans using EUD-Based mimicking of SBRT reference dose improve target dose fall off, reduced the radiation doses to the lungs, reduce planning time, which might be beneficial for patient with lung cancer in clinical.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Neoplasias Pulmonares/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
10.
Sci Rep ; 11(1): 4065, 2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33603030

RESUMEN

To perform a comparison of the different stereotactic body radiotherapy (SBRT) plans between the Varian EDGE and CyberKnife (CK) systems for locally advanced unresectable pancreatic cancer. Fifteen patients with pancreatic cancer were selected in this study. The median planning target volume (PTV) was 28.688 cm3 (5.736-49.246 cm3). The SBRT plans for the EDGE and CK were generated in the Eclipse and Multiplan systems respectively with the same contouring and dose constrains for PTV and organs at risk (OARs). Dose distributions in PTV were evaluated in terms of coverage, conformity index (CI), new conformity index (nCI), homogeneity index (HI), and gradient index (GI). OARs, including spinal cord, bowel, stomach, duodenum and kidneys were statistically evaluated by different dose-volume metrics and equivalent uniform dose (EUD). The volume covered by the different isodose lines (ISDL) ranging from 10 to 100% for normal tissue were also analyzed. All SBRT plans for EDGE and CK met the dose constraints for PTV and OARs. For the PTV, the dosimetric metrics in EDGE plans were lower than that in CK, except that D99 and GI were slightly higher. The EDGE plans with lower CI, nCI and HI were superior to generate more conformal and homogeneous dose distribution for PTV. For the normal tissue, the CK plans were better at OARs sparing. The radiobiological indices EUD of spinal cord, duodenum, stomach, and kidneys were lower for CK plans, except that liver were higher. The volumes of normal tissue covered by medium ISDLs (with range of 20-70%) were lower for CK plans while that covered by high and low ISDLs were lower for EDGE plans. This study indicated that both EDGE and CK generated equivalent plan quality, and both systems can be considered as beneficial techniques for SBRT of pancreatic cancer. EDGE plans offered more conformal and homogeneous dose distribution for PTV, while the CK plans could minimize the exposure of OARs.


Asunto(s)
Neoplasias Pancreáticas/radioterapia , Radiocirugia/métodos , Adulto , Humanos , Órganos en Riesgo/efectos de la radiación , Páncreas/efectos de la radiación , Radiometría/métodos , Radiocirugia/instrumentación
11.
Radiat Oncol ; 15(1): 34, 2020 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-32054496

RESUMEN

BACKGROUND: Both plan quality and robustness were investigated through comparing some dosimetric metrics between intensity modulated proton therapy (IMPT) and helical tomotherapy based intensity modulated radiotherapy (IMRT) for cervical cancer. METHODS: Both a spot-scanning robust (SRO) IMPT plan and a helical tomotherapy robust (TRO) IMRT plan were generated for each of 18 patients. In order to evaluate the quality of nominal plans without dose perturbations, planning scores (PS) on clinical target volume (CTV) and five organs at risk (OARs) based on clinical experience, and normal tissue complication probabilities (NTCP) of rectum and sigmoid were calculated based on Lyman-Kutcher-Burman (LKB) model. Dose volume histogram bands width (DVHBW) were calculated in 28 perturbed scenarios to evaluate plan robustness. RESULTS: Compared with TRO, the average scores of SRO nominal plans were higher in target metrics [V46.8Gy, V50Gy, Conformity and Homogeneity](16.5 vs. 15.1), and in OARs metrics (60.9 vs. 53.3), including bladder [V35,V45, Dmean,D2cc], rectum [V40,V45,D2cc,Dmax], bowel [V35,V40,V45, Dmax], sigmoid [V40,Dmax] and femoral heads [V30,Dmax]. Meanwhile, NTCP calculation showed that the toxicities of rectum and sigmoid in SRO were lower than those in TRO (rectum: 2.8% vs. 4.8%, p < 0.05; sigmoid: 5.2% vs. 5.7%, p < 0.05). DVHBW in target coverage for the SRO plan was smaller than that for the TRO plan (0.6% vs. 2.1%), which means that the SRO plan generated a more robust plan in target. CONCLUSION: Better CTV coverage and OAR Sparing were obtained in SRO nominal plan. Based on NTCP calculation, SRO was expected to allow a small reduction in rectal toxicity. Furthermore, SRO generated a more robust plan in CTV target coverage.


Asunto(s)
Órganos en Riesgo/efectos de la radiación , Garantía de la Calidad de Atención de Salud/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias del Cuello Uterino/radioterapia , Femenino , Humanos , Dosificación Radioterapéutica , Estudios Retrospectivos
12.
Radiat Oncol ; 14(1): 185, 2019 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-31665054

RESUMEN

BACKGROUND: Tumor motion may compromise the accuracy of liver stereotactic radiotherapy. In order to carry out a precise planning, estimating liver tumor motion during radiotherapy has received a lot of attention. Previous approach may have difficult to deal with image data corrupted by noise. The iterative closest point (ICP) algorithm is widely used for estimating the rigid registration of three-dimensional point sets when these data were dense or corrupted. In the light of this, our study estimated the three-dimensional (3D) rigid motion of liver tumors during stereotactic liver radiotherapy using reconstructed 3D coordinates of fiducials based on the ICP algorithm. METHODS: Four hundred ninety-five pairs of orthogonal kilovoltage (KV) images from the CyberKnife stereo imaging system for 12 patients were used in this study. For each pair of images, the 3D coordinates of fiducial markers inside the liver were calculated via geometric derivations. The 3D coordinates were used to calculate the real-time translational and rotational motion of liver tumors around three axes via an ICP algorithm. The residual error was also investigated both with and without rotational correction. RESULTS: The translational shifts of liver tumors in left-right (LR), anterior-posterior (AP),and superior-inferior (SI) directions were 2.92 ± 1.98 mm, 5.54 ± 3.12 mm, and 16.22 ± 5.86 mm, respectively; the rotational angles in left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions were 3.95° ± 3.08°, 4.93° ± 2.90°, and 4.09° ± 1.99°, respectively. Rotational correction decreased 3D fiducial displacement from 1.19 ± 0.35 mm to 0.65 ± 0.24 mm (P<0.001). CONCLUSIONS: The maximum translational movement occurred in the SI direction. Rotational correction decreased fiducial displacements and increased tumor tracking accuracy.


Asunto(s)
Neoplasias Hepáticas/radioterapia , Radiocirugia/métodos , Adulto , Anciano , Algoritmos , Marcadores Fiduciales , Humanos , Persona de Mediana Edad , Rotación
13.
Onco Targets Ther ; 12: 6385-6391, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31496740

RESUMEN

PURPOSES: The main aim of the study was to investigate the dosimetric difference between acuros XB algorithm (AXB), anisotropic analytic algorithm (AAA), and pencil beam convolution (PBC) algorithm in stereotactic body radiation therapy (SBRT) plan for non-small cell lung cancer (NSCLC). PATIENTS AND METHODS: Thirty-eight NSCLC patients were included. GTV, PTV, and organs at risk were delineated by the radiation oncologists. Three optimized SBRT plans for each patients were gained using three algorithms of AXB, AAA, and PBC with the identical plan parameters. Dosimetric endpoints were collected and compared among the three plans, including dosimetric criteria: V100%, V90%, PTV Dmin, Dmax, Dmean, homogeneity index (HI), and Paddick conformity index (CI). RESULTS: AXB plan resulted in decreased V100% with a mean difference 6.14% compared with PBC plan (For V100%, AXB vs AAA vs PBC=93.44% vs 95.54% vs 99.58%, P<0.05). Three plans showed no significant difference as to the parameter V90%. AXB plan leaded to reduced Dmin of PTV compared with other two algorithms (For Dmin of PTV, AXB vs AAA vs PBC=4048cGy vs 4365Gy vs 4873Gy, P<0.05). PBC induced the enhanced trend of Dmax of PTV compared with other two algorithms (Dmax among three algorithms, P>0.05); and increased the Dmean of PTV in three algorithms with significant difference (For Dmean of PTV, AXB vs AAA vs PBC=5332cGy vs 5330Gy vs 5785Gy, P<0.05). AXB algorithm achieved a similar plan conformity with other two algorithms (For CI, AXB vs AAA vs PBC=0.80 vs 0.85 vs 0.71, P>0.05). CONCLUSION: For SBRT plan of NSCLC, AAA and PBC algorithms overestimate target coverage, AXB algorithm is recommended for the SBRT plan of NSCLC.

14.
J Neurosurg ; 132(4): 1024-1032, 2019 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-30901747

RESUMEN

OBJECTIVE: The authors sought to compare the dosimetric quality of hypofractionated stereotactic radiosurgery in treating sizeable brain tumors across the following treatment platforms: GammaKnife (GK) Icon, CyberKnife (CK) G4, volumetric modulated arc therapy (VMAT) on the Varian TrueBeam STx, double scattering proton therapy (DSPT) on the Mevion S250, and intensity modulated proton therapy (IMPT) on the Varian ProBeam. METHODS: In this retrospective study, stereotactic radiotherapy treatment plans were generated for 10 patients with sizeable brain tumors (> 3 cm in longest diameter) who had been treated with VMAT. Six treatment plans, 20-30 Gy in 5 fractions, were generated for each patient using the same constraints for each of the following radiosurgical methods: 1) GK, 2) CK, 3) coplanar arc VMAT (VMAT-C), 4) noncoplanar arc VMAT (VMAT-NC), 5) DSPT, and 6) IMPT. The coverage; conformity index; gradient index (GI); homogeneity index; mean and maximum point dose of organs at risk; total dose volume (V) in Gy to the normal brain for 2 Gy (V2), 5 Gy (V5), and 12 Gy (V12); and integral dose were compared across all platforms. RESULTS: Among the 6 techniques, GK consistently produced a sharper dose falloff despite a greater central target dose. GK gave the lowest GI, with a mean of 2.7 ± 0.1, followed by CK (2.9 ± 0.1), VMAT-NC (3.1 ± 0.3), and VMAT-C (3.5 ± 0.3). The highest mean GIs for the proton beam treatments were 3.8 ± 0.4 for DSPT and 3.9 ± 0.4 for IMPT. The GK consistently targeted the lowest normal brain volume, delivering 5 to 12 Gy when treating relatively smaller- to intermediate-sized lesions (less than 15-20 cm3). Yet, the differences across the 6 modalities relative to GK decreased with the increase of target volume. In particular, the proton treatments delivered the lowest V5 to the normal brain when the target size was over 15-20 cm3 and also produced the lowest integral dose to the normal brain regardless of the target size. CONCLUSIONS: This study provides an insightful understanding of dosimetric quality from both photon and proton treatment across the most advanced stereotactic radiotherapy platforms.

15.
Radiat Oncol ; 13(1): 11, 2018 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-29357875

RESUMEN

BACKGROUND: To identify optimization of dose distributions of target volumes and decrease of radiation doses to normal tissues during stereotactic body radiation therapy (SBRT) for pancreatic cancer with dose-limiting auto-shells. METHODS: With the same prescription dose, dose constraints of normal organs and calculation algorithm, treatment plans of each eligible patient were re-generated with 3 shells, 5 shells and 7 shells, respectively. The prescription isodose line and beam number of each patient in 3-shell, 5-shell and 7-shell plan remained the same. Hence, a triplet data set of dosimetric parameters was generated and analyzed. RESULTS: As the increase of shell number, the conformal index, volumes encompassed by 100% prescription isodose line and 30% prescription isodose line significantly decreased. The new conformal index was higher in 3-shell group than that in 5-shell and 7-shell group. A sharper dose fall-off was found in 5-shell and 7-shell group compared to 3-shell group. And the tumor coverage in 7-shell was better than that of 3-shell and 5-shell. Lower D5cc of the intestine, D10cc of the stomach, Dmax of the spinal cord and smaller V10 of the spleen was confirmed in 7-shell group compared to 3-shell group. CONCLUSIONS: More conformal dose distributions of target volumes and lower radiation doses to normal organs could be performed with the increase of dose-limiting auto-shells, which may be more beneficial to potential critical organs without established dose constraints.


Asunto(s)
Neoplasias Pancreáticas/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
16.
Med Dosim ; 43(3): 207-213, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28993019

RESUMEN

To provide a modified formula consistent with the Monte Carlo (MC) algorithm for dose calculations during stereotactic ablative body radiotherapy for non-small cell lung cancer. Seventy CyberKnife treatment plans were calculated and analyzed by MC and ray-tracing (RT) algorithms, separately. Parameters of treatment plans were compared, and those associated with differences of dose distributions were analyzed to establish a modified formula. Gross tumor volume and tumor tracking volume (TTV) were defined as the evident disease on the sequences of the window width and level of the lung and the mediastinum. Additionally, the formula was validated by another 20 plans. The prescription dose of the 90 patients was 60 Gy/5f. The RT algorithm overestimated the planning target volume (PTV) D95 by an average of 8.59 Gy and the gross tumor volume D99 by an average of 5.84 Gy. The homogeneity index of PTV was underestimated by 0.11 on average, whereas the conformity index and new conformity index was underestimated by 0.05. The RT algorithm overestimated the dose distribution to the spinal cord by 2.23 Gy, the esophagus by 1.96 Gy, the trachea by 1.89 Gy, the left-sided bronchus by 1.77 Gy, the right-sided bronchus by 1.64 Gy, and the heart by 2.16 Gy. The average whole-lung dose volumes of lung tissues and dose volumes of V5 were overestimated by 2.69 Gy and 7.52%, respectively. A power function distribution (R2 = 0.8626) was confirmed between PTV D95 and TTV volumes. PTV D95 calculated by the MC algorithm could be computed easily with TTV and PTV D95 calculated by the RT algorithm based on the formula. The modified equation was more consistent with MC algorithm than with other formula, which could be a reference to those not accessible to the MC algorithm.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Radiocirugia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...