J Neurosurg Spine ; : 1-13, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728765

RESUMEN

OBJECTIVE: The goal of this study was to assess the safety of mapping spinal cord locomotor networks using penetrating stimulation microelectrodes in Yucatan minipigs (YMPs) as a clinically translational animal model. METHODS: Eleven YMPs were trained to walk up and down a straight line. Motion capture was performed, and electromyographic (EMG) activity of hindlimb muscles was recorded during overground walking. The YMPs underwent a laminectomy and durotomy to expose the lumbar spinal cord. Using an ultrasound-guided stereotaxic frame, microelectrodes were inserted into the spinal cord in 8 animals. Pial cuts were made to prevent tissue dimpling before microelectrode insertion. Different locations within the lumbar enlargement were electrically stimulated to map the locomotor networks. The remaining 3 YMPs served as sham controls, receiving the laminectomy, durotomy, and pial cuts but not microelectrode insertion. The Porcine Thoracic Injury Behavioral Scale (PTIBS) and hindlimb reflex assessment results were recorded for 4 weeks postoperatively. Overground gait kinematics and hindlimb EMG activity were recorded again at weeks 3 and 4 postoperatively and compared with preoperative measures. The animals were euthanized at the end of week 4, and the lumbar spinal cords were extracted and preserved for immunohistochemical analysis. RESULTS: All YMPs showed transient deficits in hindlimb function postoperatively. Except for 1 YMP in the experimental group, all animals regained normal ambulation and balance (PTIBS score 10) at the end of weeks 3 and 4. One animal in the experimental group showed gait and balance deficits by week 4 (PTIBS score 4). This animal was excluded from the kinematics and EMG analyses. Overground gait kinematic measures and EMG activity showed no significant (p > 0.05) differences between preoperative and postoperative values, and between the experimental and sham groups. Less than 5% of electrode tracks were visible in the tissue analysis of the animals in the experimental group. There was no statistically significant difference in damage caused by pial cuts between the experimental and sham groups. Tissue damage due to the pial cuts was more frequently observed in immunohistochemical analyses than microelectrode tracks. CONCLUSIONS: These findings suggest that mapping spinal locomotor networks in porcine models can be performed safely, without lasting damage to the spinal cord.

2.
Nat Biomed Eng ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38097809

RESUMEN

Restoring somatosensory feedback in individuals with lower-limb amputations would reduce the risk of falls and alleviate phantom limb pain. Here we show, in three individuals with transtibial amputation (one traumatic and two owing to diabetic peripheral neuropathy), that sensations from the missing foot, with control over their location and intensity, can be evoked via lateral lumbosacral spinal cord stimulation with commercially available electrodes and by modulating the intensity of stimulation in real time on the basis of signals from a wireless pressure-sensitive shoe insole. The restored somatosensation via closed-loop stimulation improved balance control (with a 19-point improvement in the composite score of the Sensory Organization Test in one individual) and gait stability (with a 5-point improvement in the Functional Gait Assessment in one individual). And over the implantation period of the stimulation leads, the three individuals experienced a clinically meaningful decrease in phantom limb pain (with an average reduction of nearly 70% on a visual analogue scale). Our findings support the further clinical assessment of lower-limb neuroprostheses providing somatosensory feedback.

4.
Science ; 382(6671): eabn4732, 2023 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-37943926

RESUMEN

Miniature wireless bioelectronic implants that can operate for extended periods of time can transform how we treat disorders by acting rapidly on precise nerves and organs in a way that drugs cannot. To reach this goal, materials and methods are needed to wirelessly transfer energy through the body or harvest energy from the body itself. We review some of the capabilities of emerging energy transfer methods to identify the performance envelope for existing technology and discover where opportunities lie to improve how much-and how efficiently-we can deliver energy to the tiny bioelectronic implants that can support emerging medical technologies.


Asunto(s)
Transferencia de Energía , Miniaturización , Prótesis e Implantes , Dispositivos Electrónicos Vestibles , Tecnología Inalámbrica , Humanos , Cuerpo Humano
5.
J Neurophysiol ; 130(4): 1008-1014, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37701940

RESUMEN

The dynamics and interaction of spinal and supraspinal centers during locomotor adaptation remain vaguely understood. In this work, we use Hoffmann reflex measurements to investigate changes in spinal reflex gains during split-belt locomotor adaptation. We show that spinal reflex gains are dynamically modulated during split-belt locomotor adaptation. During first exposure to split-belt transitions, modulation occurs mostly on the leg ipsilateral to the speed change and constitutes rapid suppression or facilitation of the reflex gains, followed by slow recovery to baseline. Over repeated exposure, the modulation pattern washes out. We further show that reflex gain modulation strongly correlates with correction of leg asymmetry, and cannot be explained by speed modulation solely. We argue that reflex modulation is likely of supraspinal origins and constitutes an integral part of the neural substrate underlying split-belt locomotor adaptation.NEW & NOTEWORTHY This work presents direct evidence for spinal reflex modulation during locomotor adaptation. In particular, we show that reflexes can be modulated on-demand unilaterally during split-belt locomotor adaptation and speculate about reflex modulation as an underlying mechanism for adaptation of gait asymmetry in healthy adults.


Asunto(s)
Marcha , Reflejo , Adulto , Humanos , Electromiografía , Columna Vertebral , Adaptación Fisiológica , Caminata , Prueba de Esfuerzo
6.
Front Neurosci ; 17: 1104419, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36968482

RESUMEN

Neural engineering is an emerging and multidisciplinary field in which engineering approaches are applied to neuroscience problems. Women are underrepresented in engineering fields, and indeed in science, technology, engineering, and mathematics (STEM) fields generally. Underrepresentation of women is particularly notable at later academic career stages, suggesting that even though women are interested in the field, barriers exist that ultimately cause them to leave. Here, we investigate many of the obstacles to women's success in the field of neural engineering and provide recommendations and materials to overcome them. We conducted a review of the literature from the past 15 years regarding the experiences of women in academic careers, as well as reports on the number of women in fields closely related to neural engineering from the National Science Foundation (NSF) and the American Society for Engineering Education (ASEE). Additionally, we interviewed six women in neural engineering who are involved in initiatives and outreach concerning the inclusion and experiences of women in engineering. Throughout the literature and interviews, we identified common themes spanning the role of identity and confidence, professional relationships, career-related hurdles, and personal and professional expectations. We explore each of these themes in detail and provide resources to support the growth of women as they climb within the field of neural engineering.

7.
J Neural Eng ; 20(1)2023 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-36595241

RESUMEN

Objective.Spinal cord neuromodulation has gained much attention for demonstrating improved motor recovery in people with spinal cord injury, motivating the development of clinically applicable technologies. Among them, transcutaneous spinal cord stimulation (tSCS) is attractive because of its non-invasive profile. Many tSCS studies employ a high-frequency (10 kHz) carrier, which has been reported to reduce stimulation discomfort. However, these claims have come under scrutiny in recent years. The purpose of this study was to determine whether using a high-frequency carrier for tSCS is more comfortable at therapeutic amplitudes, which evoke posterior root-muscle (PRM) reflexes.Approach.In 16 neurologically intact participants, tSCS was delivered using a 1 ms long monophasic pulse with and without a high-frequency carrier. Stimulation amplitude and pulse duration were varied and PRM reflexes were recorded from the soleus, gastrocnemius, and tibialis anterior muscles. Participants rated their discomfort during stimulation from 0 to 10 at PRM reflex threshold.Main Results.At PRM reflex threshold, the addition of a high-frequency carrier (0.87 ± 0.2) was equally comfortable as conventional stimulation (1.03 ± 0.18) but required approximately double the charge to evoke the PRM reflex (conventional: 32.4 ± 9.2µC; high-frequency carrier: 62.5 ± 11.1µC). Strength-duration curves for tSCS with a high-frequency carrier had a rheobase that was 4.8× greater and a chronaxie that was 5.7× narrower than the conventional monophasic pulse, indicating that the addition of a high-frequency carrier makes stimulation less efficient in recruiting neural activity in spinal roots.Significance.Using a high-frequency carrier for tSCS is equally as comfortable and less efficient as conventional stimulation at amplitudes required to stimulate spinal dorsal roots.


Asunto(s)
Traumatismos de la Médula Espinal , Estimulación de la Médula Espinal , Humanos , Estimulación de la Médula Espinal/métodos , Médula Espinal/fisiología , Raíces Nerviosas Espinales/fisiología , Músculo Esquelético/fisiología
8.
Int IEEE EMBS Conf Neural Eng ; 2021: 609-612, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34630868

RESUMEN

Chronic pain affects millions of people in the United States and pharmacological treatments have been ineffective. Dorsal root ganglion (DRG) stimulation is a neuromodulation method that delivers electrical stimulation to the DRG to relieve pain. DRG electrodes are rigid and cylindrical. The implantation of DRG electrodes requires a technically-challenging surgery that involves steering electrodes laterally towards the DRG. The Injectrode is an injectable conductive polymer that cures in place and is capable of delivering electrical current to stimulate neural tissue. We used the Injectrode to stimulate the L6 and L7 DRG in cats, measuring neural responses evoked in the sciatic, tibial, and common peroneal nerves to measure the thresholds for activating fibers. A cylindrical stainless-steel electrode was used for comparison. Thresholds were 38% higher with the Injectrode versus stainless-steel, likely owing to its larger contact surface area with the DRG. Both Aα and Aß sensory fibers were activated using DRG stimulation. The Injectrode has the potential to offer a new and simple method for DRG stimulation that can potentially offer more complete coverage of the DRG.

9.
J Neural Eng ; 18(5)2021 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-34650008

RESUMEN

Objective. The goal of this work was to compare afferent fiber recruitment by dorsal root ganglion (DRG) stimulation using an injectable polymer electrode (Injectrode®) and a more traditional cylindrical metal electrode.Approach. We exposed the L6 and L7 DRG in four cats via a partial laminectomy or burr hole. We stimulated the DRG using an Injectrode or a stainless steel (SS) electrode using biphasic pulses at three different pulse widths (80, 150, 300µs) and pulse amplitudes spanning the range used for clinical DRG stimulation. We recorded antidromic evoked compound action potentials (ECAPs) in the sciatic, tibial, and common peroneal nerves using nerve cuffs. We calculated the conduction velocity of the ECAPs and determined the charge-thresholds and recruitment rates for ECAPs from Aα, Aß, and Aδfibers. We also performed electrochemical impedance spectroscopy measurements for both electrode types.Main results. The ECAP thresholds for the Injectrode did not differ from the SS electrode across all primary afferents (Aα, Aß, Aδ) and pulse widths; charge-thresholds increased with wider pulse widths. Thresholds for generating ECAPs from Aßfibers were 100.0 ± 32.3 nC using the SS electrode, and 90.9 ± 42.9 nC using the Injectrode. The ECAP thresholds from the Injectrode were consistent over several hours of stimulation. The rate of recruitment was similar between the Injectrodes and SS electrode and decreased with wider pulse widths.Significance. The Injectrode can effectively excite primary afferents when used for DRG stimulation within the range of parameters used for clinical DRG stimulation. The Injectrode can be implanted through minimally invasive techniques while achieving similar neural activation to conventional electrodes, making it an excellent candidate for future DRG stimulation and neuroprosthetic applications.


Asunto(s)
Ganglios Espinales , Nervio Peroneo , Potenciales de Acción , Estimulación Eléctrica/métodos , Electrodos , Potenciales Evocados , Ganglios Espinales/fisiología
10.
J Neural Eng ; 18(3)2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33578409

RESUMEN

Objective. Established guidelines for safe levels of electrical stimulation for neural prostheses are based on a limited range of the stimulus parameters used clinically. Recent studies have reported particulate platinum (Pt) associated with long-term clinical use of these devices, highlighting the need for more carefully defined safety limits. We previously reported no adverse effects of Pt corrosion products in the cochleae of guinea pigs following 4 weeks of electrical stimulation using charge densities far greater than the published safe limits for cochlear implants. The present study examines the histopathological effects of Pt within the cochlea following continuous stimulation at a charge density well above the defined safe limits for periods up to 6 months.Approach. Six cats were bilaterally implanted with Pt electrode arrays and unilaterally stimulated using charge balanced current pulses at a charge density of 267µC cm-2phase-1using a tripolar electrode configuration. Electrochemical measurements were made throughout the implant duration and evoked potentials recorded at the outset and on completion of the stimulation program. Cochleae were examined histologically for particulate Pt, tissue response, and auditory nerve survival; electrodes were examined for surface corrosion; and cochlea, brain, kidney, and liver tissue analysed for trace levels of Pt.Main results. Chronic stimulation resulted in both a significant increase in tissue response and particulate Pt within the tissue capsule surrounding the electrode array compared with implanted, unstimulated control cochleae. Importantly, there was no stimulus-induced loss of auditory neurons (ANs) or increase in evoked potential thresholds. Stimulated electrodes were significantly more corroded compared with unstimulated electrodes. Trace analysis revealed Pt in both stimulated and control cochleae although significantly greater levels were detected within stimulated cochleae. There was no evidence of Pt in brain or liver; however, trace levels of Pt were recorded in the kidneys of two animals. Finally, increased charge storage capacity and charge injection limit reflected the more extensive electrode corrosion associated with stimulated electrodes.Significance. Long-term electrical stimulation of Pt electrodes at a charge density well above existing safety limits and nearly an order of magnitude higher than levels used clinically, does not adversely affect the AN population or reduce neural function, despite a stimulus-induced tissue response and the accumulation of Pt corrosion product. The mechanism resulting in Pt within the unstimulated cochlea is unclear, while the level of Pt observed systemically following stimulation at these very high charge densities does not appear to be of clinical significance.


Asunto(s)
Implantes Cocleares , Platino (Metal) , Animales , Cóclea/patología , Estimulación Eléctrica , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Cobayas , Solubilidad
11.
Front Bioeng Biotechnol ; 9: 796042, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34988068

RESUMEN

Minimally invasive neuromodulation technologies seek to marry the neural selectivity of implantable devices with the low-cost and non-invasive nature of transcutaneous electrical stimulation (TES). The Injectrode® is a needle-delivered electrode that is injected onto neural structures under image guidance. Power is then transcutaneously delivered to the Injectrode using surface electrodes. The Injectrode serves as a low-impedance conduit to guide current to the deep on-target nerve, reducing activation thresholds by an order of magnitude compared to using only surface stimulation electrodes. To minimize off-target recruitment of cutaneous fibers, the energy transfer efficiency from the surface electrodes to the Injectrode must be optimized. TES energy is transferred to the Injectrode through both capacitive and resistive mechanisms. Electrostatic finite element models generally used in TES research consider only the resistive means of energy transfer by defining tissue conductivities. Here, we present an electroquasistatic model, taking into consideration both the conductivity and permittivity of tissue, to understand transcutaneous power delivery to the Injectrode. The model was validated with measurements taken from (n = 4) swine cadavers. We used the validated model to investigate system and anatomic parameters that influence the coupling efficiency of the Injectrode energy delivery system. Our work suggests the relevance of electroquasistatic models to account for capacitive charge transfer mechanisms when studying TES, particularly when high-frequency voltage components are present, such as those used for voltage-controlled pulses and sinusoidal nerve blocks.

13.
J Neural Eng ; 17(5): 056009, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-32916669

RESUMEN

OBJECTIVE: Cochleae of long-term cochlear implant users have shown evidence of particulate platinum (Pt) corroded from the surface of Pt electrodes. The pathophysiological effect of Pt within the cochlea has not been extensively investigated. We previously evaluated the effects of Pt corrosion at high charge densities and reported negligible pathophysiological impact. The present study extends this work by examining techniques that may reduce Pt corrosion. APPROACH: Deafened guinea pigs were continuously stimulated for 28 d using biphasic current pulses at extreme charge densities using: (i) electrode shorting; (ii) electrode shorting with capacitive coupling (CC); or (iii) electrode shorting with alternating leading phase (AP). On completion of stimulation, cochleae were examined for corrosion product, tissue response, auditory nerve (AN) survival and trace levels of Pt; and electrodes examined for surface corrosion. MAIN RESULTS: Pt corrosion was evident at ≥200 µC cm-2 phase-1; the amount dependent on charge density (p< 0.01) and charge recovery technique (p < 0.01); reduced corrosion was apparent using CC. Tissue response increased with charge density (p< 0.007); cochleae stimulated at ≥200 µC cm-2 phase-1 exhibited a vigorous response including a focal region of necrosis and macrophages. Notably, tissue response was not dependent on the charge recovery technique (p = 0.56). Despite stimulation at high charge densities resulting in significant levels of Pt corrosion, there was no stimulus induced loss of ANs. SIGNIFICANCE: Significant increases in tissue response and Pt corrosion were observed following stimulation at high charge densities. Charge recovery using CC, and to a lesser extent AP, reduced the amount of Pt corrosion but not the tissue response. Stimulation at change densities an order of magnitude higher than those used when programming cochlear implant recipients in the clinic, produced a vigorous tissue response and corrosion products without evidence of neural loss.


Asunto(s)
Implantes Cocleares , Estimulación Eléctrica , Potenciales Evocados Auditivos del Tronco Encefálico , Platino (Metal) , Animales , Cobayas , Solubilidad
14.
J Neural Eng ; 17(3): 036012, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32408281

RESUMEN

OBJECTIVE: To evaluate the electrochemical properties, biological response, and surface characterization of an electrodeposited Platinum-Iridium (Pt-Ir) electrode coating on cochlear implants subjected to chronic stimulation in vivo. APPROACH: Electrochemical impedance spectroscopy (EIS), charge storage capacity (CSC), charge injection limit (CIL), and voltage transient (VT) impedance were measured bench-top before and after implant and in vivo. Coated Pt-Ir and uncoated Pt electrode arrays were implanted into cochlea of normal hearing rats and stimulated for ∼4 h d, 5 d week-1 for 5 weeks at levels within the normal clinical range. Neural function was monitored using electrically-evoked auditory brainstem responses. After explant, the electrode surfaces were assessed, and cochleae examined histologically. MAIN RESULTS: When measured on bench-top before and after stimulation, Pt-Ir coated electrodes had significantly lower VT impedance (p < 0.001) and significantly higher CSC (p < 0.001) and CIL (p < 0.001) compared to uncoated Pt electrodes. In vivo, the CSC and CIL of Pt-Ir were significantly higher than Pt throughout the implantation period (p= 0.047 and p< 0.001, respectively); however, the VT impedance (p= 0.3) was not. There was no difference in foreign body response between material cohorts, although cochleae implanted with coated electrodes contained small deposits of Pt-Ir. There was no evidence of increased neural loss or loss of neural function in either group. Surface examination revealed no Pt corrosion on any electrodes. SIGNIFICANCE: Electrodeposited Pt-Ir electrodes demonstrated significant improvements in electrochemical performance on the bench-top and in vivo compared to uncoated Pt. Neural function and tissue response to Pt-Ir electrodes were not different from uncoated Pt, despite small deposits of Pt-Ir in the tissue capsule. Electrodeposited Pt-Ir coatings offer promise as an improved electrode coating for active neural prostheses.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Animales , Electrodos , Iridio , Platino (Metal) , Ratas
15.
J Neural Eng ; 17(3): 036002, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32348970

RESUMEN

OBJECTIVE: Neuromodulation technologies are increasingly used for improving function after neural injury. To achieve a symbiotic relationship between device and user, the device must augment remaining function, and independently adapt to day-to-day changes in function. The goal of this study was to develop predictive control strategies to produce over-ground walking in a model of hemisection spinal cord injury (SCI) using intraspinal microstimulation (ISMS). APPROACH: Eight cats were anaesthetized and placed in a sling over a walkway. The residual function of a hemisection SCI was mimicked by manually moving one hind-limb through the walking cycle. ISMS targeted motor networks in the lumbosacral enlargement to activate muscles in the other, presumably 'paralyzed' limb, using low levels of current (<130 µA). Four people took turns to move the 'intact' limb, generating four different walking styles. Two control strategies, which used ground reaction force and angular velocity information about the manually moved 'intact' limb to control the timing of the transitions of the 'paralyzed' limb through the step cycle, were compared. The first strategy used thresholds on the raw sensor values to initiate transitions. The second strategy used reinforcement learning and Pavlovian control to learn predictions about the sensor values. Thresholds on the predictions were then used to initiate transitions. MAIN RESULTS: Both control strategies were able to produce alternating, over-ground walking. Transitions based on raw sensor values required manual tuning of thresholds for each person to produce walking, whereas Pavlovian control did not. Learning occurred quickly during walking: predictions of the sensor signals were learned rapidly, initiating correct transitions after ≤4 steps. Pavlovian control was resilient to different walking styles and different cats, and recovered from induced mistakes during walking. SIGNIFICANCE: This work demonstrates, for the first time, that Pavlovian control can augment remaining function and facilitate personalized walking with minimal tuning requirements.


Asunto(s)
Traumatismos de la Médula Espinal , Caminata , Animales , Gatos , Extremidades , Miembro Posterior
16.
J Neural Eng ; 17(2): 026018, 2020 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-32135529

RESUMEN

OBJECTIVE: Evaluate electrochemical properties, biological response, and surface characterization of a conductive hydrogel (CH) coating following chronic in vivo stimulation. APPROACH: Coated CH or uncoated smooth platinum (Pt) electrode arrays were implanted into the cochlea of rats and stimulated over a 5 week period with more than 57 million biphasic current pulses. Electrochemical impedance spectroscopy (EIS), charge storage capacity (CSC), charge injection limit (CIL), and voltage transient (VT) impedance were measured on the bench before and after stimulation, and in vivo during the stimulation program. Electrically-evoked auditory brainstem responses were recorded to monitor neural function. Following explant, the cochleae were examined histologically and electrodes were examined using scanning electron microscopy. MAIN RESULTS: CH coated electrodes demonstrated a bench-top electrochemical advantage over Pt electrodes before and after the electrical stimulation program. In vivo, CH coated electrodes also had a significant advantage over Pt electrodes throughout the stimulation program, exhibiting higher CSC (p= 0.002), larger CIL (p = 0.002), and lower VT impedance (p < 0.001). The CH cohort exhibited a greater tissue response (p= 0.003) with small deposits of particulate material within the tissue capsule. There was no loss in auditory neuron density or change in neural response thresholds in any cochleae. Examination of the electrode surface revealed that most CH electrodes exhibited some coating loss; however, there was no evidence of corrosion in the underlying Pt. SIGNIFICANCE: CH coated electrodes demonstrated significant electrochemical advantages on the bench-top and in vivo and maintained neural function despite an increased tissue response and coating loss. While further research is required to understand the cause of the coating loss, CH electrodes provide promise for use in neural prostheses.


Asunto(s)
Implantes Cocleares , Animales , Cóclea , Estimulación Eléctrica , Electrodos , Electrodos Implantados , Potenciales Evocados Auditivos del Tronco Encefálico , Hidrogeles , Ratas
17.
J Neural Eng ; 17(1): 016015, 2019 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-31652427

RESUMEN

OBJECTIVE: To systematically compare the in vitro electrochemical and mechanical properties of several electrode coatings that have been reported to increase the efficacy of medical bionics devices by increasing the amount of charge that can be delivered safely to the target neural tissue. APPROACH: Smooth platinum (Pt) ring and disc electrodes were coated with reduced graphene oxide, conductive hydrogel, or electrodeposited Pt-Ir. Electrodes with coatings were compared with uncoated smooth Pt electrodes before and after an in vitro accelerated aging protocol. The various coatings were compared mechanically using the adhesion-by-tape test. Electrodes were stimulated in saline for 24 hours/day 7 days/week for 21 d at 85 °C (1.6-year equivalence) at a constant charge density of 200 µC/cm2/phase. Electrodes were graded on surface corrosion and trace analysis of Pt in the electrolyte after aging. Electrochemical measurements performed before, during, and after aging included electrochemical impedance spectroscopy, cyclic voltammetry, and charge injection limit and impedance from voltage transient recordings. MAIN RESULTS: All three coatings adhered well to smooth Pt and exhibited electrochemical advantage over smooth Pt electrodes prior to aging. After aging, graphene coated electrodes displayed a stimulation-induced increase in impedance and reduction in the charge injection limit (p  < 0.001), alongside extensive corrosion and release of Pt into the electrolyte. In contrast, both conductive hydrogel and Pt-Ir coated electrodes had smaller impedances and larger charge injection limits than smooth Pt electrodes (p  < 0.001) following aging regardless of the stimulus level and with little evidence of corrosion or Pt dissolution. SIGNIFICANCE: This study rigorously tested the mechanical and electrochemical performance of electrode coatings in vitro and provided suitable candidates for future in vivo testing.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Técnicas Electroquímicas/métodos , Galvanoplastia/métodos , Grafito/química , Hidrogeles/química , Platino (Metal)/química , Implantes Cocleares , Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/métodos , Técnicas Electroquímicas/instrumentación , Electrodos Implantados
18.
J Neural Eng ; 15(5): 056023, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30084388

RESUMEN

OBJECTIVE: The goal of this study was to develop control strategies to produce alternating, weight-bearing stepping in a cat model of hemisection spinal cord injury (SCI) using intraspinal microstimulation (ISMS). APPROACH: Six cats were anesthetized and the functional consequences of a hemisection SCI were simulated by manually moving one hind-limb through the gait cycle over a moving treadmill belt. ISMS activated the muscles in the other leg by stimulating motor networks in the lumbosacral enlargement using low levels of current (<110 µA). The control strategy used signals from ground reaction forces and angular velocity from the manually-moved limb to anticipate states of the gait cycle, and controlled ISMS to move the other hind-limb into the opposite state. Adaptive control strategies were developed to ensure weight-bearing at different stepping speeds. The step period was predicted using generalizations obtained through four supervised machine learning algorithms and used to adapt the control strategy for faster steps. MAIN RESULTS: At a single speed, 100% of the steps had sufficient weight-bearing; at faster speeds without adaptation, 97.6% of steps were weight-bearing (significantly less than that for single speed; p = 0.002). By adapting the control strategy for faster steps using the predicted step period, weight-bearing was achieved in more than 99% of the steps in three of four methods (significantly more than without adaptation p < 0.04). Overall, a multivariate model tree increased the number of weight-bearing steps, restored step symmetry, and maintained alternation at faster stepping speeds. SIGNIFICANCE: Through the adaptive control strategies guided by supervised machine learning, we were able to restore weight-bearing and maintain alternation and step symmetry at varying stepping speeds.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Cojera Animal/fisiopatología , Prótesis Neurales , Traumatismos de la Médula Espinal/rehabilitación , Médula Espinal , Soporte de Peso , Algoritmos , Animales , Gatos , Marcha , Miembro Posterior/fisiopatología , Cojera Animal/etiología , Locomoción , Aprendizaje Automático , Masculino , Red Nerviosa , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/fisiopatología
19.
J Nanosci Nanotechnol ; 13(4): 2885-91, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23763175

RESUMEN

Exploitation of anodically formed self-organized TiO2 nanotube arrays in mass-manufactured, disposable biosensors, rollable electrochromic displays and flexible large-area solar cells would greatly benefit from integration with transparent and flexible polymeric substrates. Such integration requires the vacuum deposition of a thin film of titanium on the desired substrate, which is then anodized in suitable media to generate TiO2 nanotube arrays. However the challenges associated with control of Ti film morphology, nanotube array synthesis conditions, and film adhesion and transparency, have necessitated the use of substrate heating during deposition to temperatures of at least 300 degrees C and as high as 500 degrees C to generate highly ordered open-pore nanotube arrays, thus preventing the use of polymeric substrates. We report on a film growth technique that exploits atomic peening to achieve high quality transparent TiO2 nanotube arrays with lengths up to 5.1 microm at room temperature on polyimide substrates without the need for substrate heating or substrate biasing or a Kauffman ion source. The superior optical quality and uniformity of the nanotube arrays was evidenced by the high specular reflectivity and the smooth pattern of periodic interferometric fringes in the transmission spectra of the nanotube arrays, from which the wavelength-dependent effective refractive index was extracted for the air-TiO2 composite medium. A fluorescent immunoassay biosensor constructed using 5.1 microm-long transparent titania nanotube arrays (TTNAs) grown on Kapton substrates detected human cardiac troponin I at a concentration of 0.1 microg ml(-1).


Asunto(s)
Técnicas Biosensibles , Electrónica , Nanotubos , Plásticos , Titanio/química , Fluorescencia , Inmunoensayo