Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Opt Lett ; 42(10): 1887-1890, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28504751

RESUMEN

Coherent beam combining in the femtosecond regime of a record number of 19 fibers is demonstrated. The interferometric phase measurement technique, particularly well suited to phase-lock a very large number of fibers, is successfully demonstrated in the femtosecond regime. A servo loop is implemented to control piezoelectric fiber stretchers for both phase and delay variation compensation. The residual phase errors are below λ/60 rms. Nearly 50% of the total energy is contained in the far-field central lobe. After compression, we obtain a combined pulse width of 300 fs identical to the master oscillator pulse width.

2.
Opt Express ; 20(19): 21627-34, 2012 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-23037281

RESUMEN

We report on the passive coherent combining of up to 8 temporally and spatially separated ultrashort pulses amplified in a stretcher-free ytterbium-doped fiber system. An initial femtosecond pulse is split into 4 temporal replicas using divided-pulse amplification, and subsequently divided in two counter-propagating beams in a Sagnac interferometer containing a fiber amplifier. The spatio-temporal distribution of the peak-power inside the amplifier allows the generation of record 3.1 µJ and 50 fs pulses at 1 MHz of repetition rate with 52 MW of peak-power from a stretcher-free fiber amplifier and without additional nonlinear post-compression stages.

3.
Opt Lett ; 37(9): 1460-2, 2012 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-22555704

RESUMEN

Using passive coherent beam combining of two ultrafast fiber amplifiers, we demonstrate the generation of high temporal quality 300 fs and 650 µJ pulses corresponding to 60 W of average power at a repetition rate of 92 kHz. Furthermore, at 2 MHz of repetition rate record coherent combining average powers of 135 W before and 105 W after compression are measured. A combining efficiency higher than 90% is maintained over the whole range of output powers and repetition rates investigated demonstrating the efficiency and robustness of the passive combining technique. The measured pulse-to-pulse relative power fluctuation at high energy is 2%, indicating that the system is essentially immune to environmental phase noise. We believe the passive combining method to be an attractive approach for compact multi-GW peak power femtosecond fiber-based sources.

4.
Opt Lett ; 37(4): 650-2, 2012 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-22344136

RESUMEN

We experimentally investigate the impact of spectral phase mismatch on the coherent beam combining of two femtosecond fiber chirped-pulse amplifiers. By measuring the differential spectral phase, both linear and nonlinear contributions are identified. An accumulated nonlinear phase as high as 6 rad has been measured, for which a combination efficiency of 91% can be obtained by symmetrizing the pump and injection powers. This also allows us to quantitatively separate the spatial and temporal contributions of the nonperfect combining efficiency.

5.
Opt Lett ; 36(5): 621-3, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21368927

RESUMEN

We demonstrate coherent beam combining of two femtosecond fiber chirped-pulse amplifiers seeded by a common oscillator. Using a feedback loop based on an electro-optic phase modulator, an average power of 7.2 W before compression is obtained with a combining efficiency of 90%. The spatial and temporal qualities of the oscillator are retained, with a recombined pulse width of 325 fs. This experiment opens up a way to scale the peak/average power of ultrafast fiber sources.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...