RESUMEN
Sudden cardiac death is defined as an abrupt, unexpected death of cardiovascular cause with loss of consciousness within 1 hour of onset of symptoms. In an effort to prevent these events, clinicians need to recognize symptoms to identify at risk patients. There is often an overlap in symptoms of chest pain, palpitations, and syncope. The workup depends on the characteristics of these symptoms. The history and physical examination often provide adequate information, but additional testing and referral to pediatric cardiology are sometimes indicated.
Asunto(s)
Arritmias Cardíacas , Muerte Súbita Cardíaca , Humanos , Niño , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Síncope/etiología , Síncope/complicaciones , Dolor en el Pecho/etiología , Dolor en el Pecho/complicaciones , Examen Físico/efectos adversosRESUMEN
BACKGROUND: Liveborn infants with non-mosaic trisomy 22 are rarely described in the medical literature. Reported lifespan of these patients ranges from minutes to 3 years, with the absence of cardiac anomalies associated with longer-term survival. The landscape for offering cardiac surgery to patients with rare autosomal trisomies is currently evolving, as has been demonstrated recently in trisomies 13 and 18. However, limited available data on patients with rare autosomal trisomies provides a significant challenge in perinatal counseling, especially when there are options for surgical intervention. CASE PRESENTATION: In this case report, we describe an infant born at term with prenatally diagnosed apparently non-mosaic trisomy 22 and multiple cardiac anomalies, including a double outlet right ventricle, hypoplastic aortic valve and severe aortic arch hypoplasia, who underwent cardiac surgery. The decisions made by her family lending to her progress and survival to this day were made with a focus on the shared decision making model and support in the prenatal and perinatal period. We also review the published data on survival and quality of life after cardiac surgery in infants with rare trisomies. CONCLUSIONS: This patient is the only known case of apparently non-mosaic trisomy 22 in the literature who has undergone cardiac surgery with significant survival benefit. This case highlights the impact of using a shared decision making model when there is prognostic uncertainty.
Asunto(s)
Anomalías Múltiples , Cardiopatías Congénitas , Lactante , Embarazo , Femenino , Humanos , Trisomía , Calidad de Vida , Toma de Decisiones Conjunta , Cardiopatías Congénitas/genética , Cardiopatías Congénitas/cirugía , Anomalías Múltiples/genéticaRESUMEN
The objective of this study was to determine medium-term morbidity and mortality of patients who have undergone device closure of an extracardiac Fontan fenestration with an Amplatzer Vascular Plug II (AVPII) or Septal Occluder (ASO). A secondary objective was to compare medium-term morbidity and mortality between these patients and other fenestrated Fontan patients. A retrospective chart review was performed on patients who underwent an extracardiac fenestrated Fontan procedure between 1992 and 2015 at Cardinal Glennon Children's Medical Center. Procedural and follow-up data were obtained and compared between those who underwent fenestration closure and those who did not. Additional outcome measures included whether the fenestration had spontaneously closed, morbidity and mortality, oxygen saturations, and hemodynamics pre- and post-closure. Fifty-nine of 118 patients (50%) with a fenestrated Fontan underwent 60 device closures of the fenestration. Thirty-two (53%) of these were with the AVPII and 28 (47%) with the ASO. There was one device embolization. At a median follow-up of 3.9 years, five patients suffered morbidity, including 2 with arrhythmias, 1 with plastic bronchitis, 1 with protein losing enteropathy, and 1 with stroke. There were no cardiopulmonary deaths in this group. Twenty-three of 118 patients (19%) had spontaneous closure. There was no difference in morbidity and mortality between patients who underwent percutaneous fenestration closure and those who either had spontaneous closure or a persistently patent fenestration. Device closure of Fontan fenestrations is a safe and effective procedure with minimal morbidity and mortality comparable to other patients with fenestrations.
Asunto(s)
Embolización Terapéutica/instrumentación , Procedimiento de Fontan/métodos , Adolescente , Cateterismo Cardíaco/métodos , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Estudios de Seguimiento , Procedimiento de Fontan/efectos adversos , Humanos , Masculino , Estudios Retrospectivos , Dispositivo Oclusor SeptalRESUMEN
The original version of this article unfortunately contained a mistake.
RESUMEN
Rotational angiography (RA) has proven to be an excellent method for evaluating congenital disease (CHD) in the cardiac cath lab, permitting acquisition of 3D datasets with superior spatial resolution. This technique has not been routinely implemented for 3D printing in CHD. We describe our case series of models printed from RA and validate our technique. All patients with models printed from RA were selected. RA acquisitions from a Toshiba Infinix-I system were postprocessed and printed with a Stratasys Eden 260. Two independent observers measured 5-10 points of interest on both the RA and the 3D model. Bland Altman plot was used to compare the measurements on rotational angiography to the printed model. Models were printed from RA in 5 patients (age 2 months-1 year). Diagnoses included (a) coronary artery aneurysm, (b) Glenn shunt, (c) coarctation of the aorta, (d) tetralogy of Fallot with MAPCAs, and (e) pulmonary artery stenosis. There was no significant measurement difference between RA and the printed model (r = 0.990, p < 0.01, Bland Altman p = 0.987). There was also no significant inter-observer variability. The MAPCAs model was referenced by the surgeon intraoperatively and was accurate. Rotational angiography can generate highly accurate 3D models in congenital heart disease, including in small vascular structures. These models can be extremely useful in patient evaluation and management.
Asunto(s)
Angiografía/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Imagenología Tridimensional/métodos , Modelos Anatómicos , Impresión Tridimensional , Niño , Preescolar , Estudios de Factibilidad , Femenino , Corazón/diagnóstico por imagen , Humanos , Lactante , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los ResultadosRESUMEN
Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.
Asunto(s)
Cateterismo Cardíaco/efectos adversos , Dilatación/efectos adversos , Diseño de Prótesis/efectos adversos , Falla de Prótesis/efectos adversos , Stents/efectos adversos , Cateterismo Cardíaco/métodos , Dilatación/métodos , Cardiopatías Congénitas/cirugíaRESUMEN
OBJECTIVES: We sought to evaluate outcomes of stent implantation (SI) for recurrent coarctation of the aorta (RC) following the Norwood operation. BACKGROUND: RC is common following the Norwood operation. Balloon angioplasty (BA) is standard treatment but may result in unsatisfactory relief of RC. SI may improve RC, but outcome data are limited. METHODS: We performed a multi-center retrospective study of patients who underwent SI for RC between the Norwood operation and Fontan completion. Outcomes were examined, including procedural success, serious adverse events (SAE), and freedom from re-intervention. A core laboratory was utilized to review angiograms. Coarctation Index (CI) was calculated before and after SI. Paired t-test and Wilcoxon signed-rank test were used to compare pre- and post-SI variables. RESULTS: Thirty-three patients at 8 centers underwent SI for RC at a median age of 5 months (IQR 4.1, 13.3) and weight of 5.9 kg (5.2, 8.6). Aortic arch gradient improved from 20 (15, 24) to 0 (0, 2) mmHg following SI (P < 0.0001). The median CI improved from 0.54 (0.43, 0.62) to 0.97 (0.89, 1.06) following SI (P < 0.0001). There were no procedural deaths but SAEs occurred in 12 (36%) patients. During a median follow-up duration of 29.7 months (6.8, 48.0), freedom from death or heart transplant was 82%, and from re-intervention was 45%, with median time to re-intervention of 20.1 months (11.4, 40.3). CONCLUSIONS: SI for treatment of RC in patients after the Norwood operation provides excellent acute relief of obstruction. Intraprocedural hemodynamic instability is common and re-intervention is frequent at mid-term follow-up.
Asunto(s)
Anomalías Múltiples , Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Procedimientos de Norwood/métodos , Sociedades Médicas , Stents , Angiografía , Aorta Torácica/cirugía , Coartación Aórtica/diagnóstico , Cardiología , Femenino , Estudios de Seguimiento , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico , Lactante , Masculino , Diseño de Prótesis , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados UnidosRESUMEN
BACKGROUND: Follow-up of transcatheter pulmonary valve replacement (TPVR) with the Melody valve has demonstrated good short-term and long-term outcomes, but there are no published studies focused on valve performance in the Contegra bovine jugular vein conduit. METHODS AND RESULTS: This is a retrospective, multicenter study of the short- and intermediate-term outcomes of Melody TPVR within the Contegra conduit in the right ventricle to pulmonary artery position. Data from 13 centers were included in the analysis. During the study period, 136 patients underwent 139 catheterizations for attempted Melody TPVR with a median follow-up of 3 years (1 day to 9.1 years). Of the 136 patients, 117 underwent successful Melody TPVR. Two patients underwent a second Melody TPVR. The majority of patients underwent placement of ≥1 stents before transcatheter pulmonary valve implantation. There was a significant reduction in peak conduit pressure gradient acutely after transcatheter pulmonary valve implantation (39 versus 10 mm Hg; P<0.001). At most recent follow-up, the maximum pulmonary valve gradient by echocardiogram remained significantly reduced relative to prevalve implant measurements (65.9 versus 27.3 mm Hg; P<0.001). The incidence of Melody transcatheter pulmonary valve stent fracture (3.4%) and infectious endocarditis (4.3%) were both low. Serious adverse events occurred in 3 patients. CONCLUSIONS: Melody TPVR in Contegra conduits is safe and effective and can be performed in a wide range of conduit sizes with preserved valve function and low incidence of stent fracture and endocarditis.
Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Cardíaco/instrumentación , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/cirugía , Venas Yugulares/trasplante , Arteria Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Animales , Implantación de Prótesis Vascular/efectos adversos , Cateterismo Cardíaco/efectos adversos , Bovinos , Niño , Preescolar , Europa (Continente) , Femenino , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Xenoinjertos , Humanos , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/fisiopatología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Arteria Pulmonar/anomalías , Arteria Pulmonar/fisiopatología , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Adulto JovenRESUMEN
OBJECTIVES: We describe the use of trans-thoracic and trans-conduit puncture to access the atria and perform interventional procedures in patients who have undergone conduit total cavopulmonary anastomosis. BACKGROUND: Catheter access to the atria following intra or extra-cardiac Fontan is desirable when there is a need for trans-atrial interventions. METHODS: Between 2009 and 2014, 5 patients ages 7 to 28 years underwent this approach; three trans-thoracic and 2 trans-conduit punctures. Various therapeutic aims were achieved. Included are: placement of pacing wire in the left atrial appendage, access to re-canalized left superior vena cava via the coronary sinus for device occlusion eliminating cyanosis, access with subsequent device closure of a dormant pulmonary valve thought to be the nidus of an embolic event, and access to the atria for ablation of an atrial tachycardia. RESULTS: Entry to the atria was successful in all five patients with either trans-thoracic access or trans-conduit puncture with subsequent intended intervention performed successfully. CONCLUSIONS: Trans-conduit puncture and trans-thoracic access may allow therapeutic procedures which mitigate the need for further open heart surgery. © 2017 Wiley Periodicals, Inc.
Asunto(s)
Cateterismo Cardíaco/métodos , Procedimiento de Fontan , Cardiopatías Congénitas/cirugía , Complicaciones Posoperatorias/terapia , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Angiografía Coronaria , Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/fisiopatología , Humanos , Cuidados Paliativos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Punciones , Resultado del Tratamiento , Adulto JovenRESUMEN
OBJECTIVE: Intravascular stents are now routinely used to treat young patients with vascular stenoses. Future stent redilations are often necessary to account for somatic growth. The purpose of this study was to compile a database of characteristics for stents commonly used in the treatment of congenital heart disease patients, and compare serial dilation to direct dilation to the maximal diameter. DESIGN: A standardized bench testing protocol was established and utilized in the assessment of all stents. Ultra high pressure balloons were used to serially dilate each stent by set increments until the stent reached at least 24 mm in diameter, developed a napkin-ring configuration, or fractured. Length and diameter of each stent were measured at baseline and following each stage of dilation. Maximal stent diameters, foreshortening properties, and ability to fracture were reported. Stents were then tested for direct dilation from the primary diameter to the maximal diameter, and the same data was obtained. RESULTS: A total of 127 stents were bench-tested, 80 of which were serially dilated and 47 directly dilated. Most premounted stents could be serially dilated to approximately twice their stated nominal diameter. All tested unmounted stents could be serially dilated to ≥20 mm. Foreshortening occurred at larger diameters, but varied significantly among different stent types. Serial dilation offered more consistent results with significantly less foreshortening and more symmetric expansion when compared with direct dilation. Most premounted stents could be fractured when serially dilated. CONCLUSIONS: All tested vascular stents can be dilated beyond their nominal implantation diameter. Serial dilation offers a much more reliable response with uniform expansion, less foreshortening, greater maximal diameter, and improved intentional fracture potential, as compared to direct dilation from the nominal to maximal diameter. In vivo studies are necessary to corroborate these findings in the congenital heart disease population.
Asunto(s)
Angioplastia de Balón/instrumentación , Cardiopatías Congénitas/complicaciones , Stents , Enfermedades Vasculares/terapia , Bases de Datos Factuales , Análisis de Falla de Equipo , Humanos , Ensayo de Materiales , Presión , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Enfermedades Vasculares/etiologíaRESUMEN
BACKGROUND: Host autoimmune activity in myocarditis has been proposed to play a role in development of cardiac disease, but evidence of autoimmunity and relationship to outcomes have not been evaluated in pediatric myocarditis. METHODS: We performed a multi-institutional study of children with clinical myocarditis. Newly diagnosed patients were followed for up to 12 months and previously diagnosed patients at a single follow-up for serum levels of autoantibodies to human cardiac myosin, beta-adrenergic receptors 1 and 2, muscarinic-2 receptors, and antibody-mediated protein kinase A (PKA) activation in heart cells in culture. Results were compared with those of healthy control children. RESULTS: Both previously diagnosed patient at follow-up (P = .0061) and newly diagnosed patients at presentation (P = .0127) had elevated cardiac myosin antibodies compared with control subjects. Antibody levels were not associated with recovery status at follow-up in either group. PKA activation was higher at presentation in the newly diagnosed patients who did not recovery normal function (P = .042). CONCLUSIONS: Children with myocarditis have evidence of autoantibodies against human cardiac myosin at diagnosis and follow-up compared with control subjects. Differences in antibody-mediated cell signaling may contribute to differences in patient outcomes, as suggested by elevated antibody-mediated PKA activation in heart cells by the serum from nonrecovered patients.
Asunto(s)
Autoanticuerpos/inmunología , Autoinmunidad , Miosinas Cardíacas/inmunología , Proteínas Quinasas Dependientes de AMP Cíclico/inmunología , Miocarditis/inmunología , Miocitos Cardíacos/inmunología , Autoanticuerpos/sangre , Niño , Preescolar , Proteínas Quinasas Dependientes de AMP Cíclico/análisis , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Lactante , Miocarditis/sangre , Miocarditis/diagnóstico por imagen , Miocitos Cardíacos/químicaRESUMEN
Specific viruses are associated with pediatric myocarditis, but the prevalence of viral DNAemia detected by blood polymerase chain reaction (PCR) is unknown. We evaluated the prevalence of known cardiotropic viruses (enterovirus, adenovirus, human herpesvirus 6, and parvovirus B19) in children with clinical myocarditis (n = 21). Results were compared to pediatric controls with similar viral PCR testing. The majority of positive PCR (89 %) was noted in children ≤12 months of age at diagnosis compared to older children. Infant myocarditis patients (8/10) had increased the prevalence of PCR positivity compared to infant pediatric controls (4/114) (p < 0.0001). Other than age, patient characteristics at diagnosis were similar between PCR-positive and PCR-negative patients. Both PCR-negative myocarditis infants had clinical recovery at follow-up. Of the PCR-positive myocarditis infants, 4 had clinical recovery, 2 developed chronic cardiomyopathy, 1 underwent heart transplant, and 1 died. Infants with clinical myocarditis have a high rate of blood viral positivity, which is higher compared to older children with myocarditis and healthy infant controls. Age-related differences in PCR positivity may be due to differences in host and/or virus characteristics. Our findings suggest that viral blood PCR may be a useful diagnostic tool and identify patients who would potentially benefit from virus-specific therapy.
Asunto(s)
Adenoviridae/aislamiento & purificación , ADN Viral/sangre , Enterovirus/aislamiento & purificación , Herpesvirus Humano 6/aislamiento & purificación , Miocarditis/diagnóstico , Parvovirus B19 Humano/aislamiento & purificación , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Corazón/virología , Trasplante de Corazón , Humanos , Lactante , Masculino , Miocarditis/sangre , Miocarditis/virología , Reacción en Cadena de la Polimerasa , Estados UnidosAsunto(s)
Anomalías de los Vasos Coronarios/patología , Vasos Coronarios/patología , Muerte Súbita Cardíaca/patología , Autopsia , Biopsia , Causas de Muerte , Niño , Anomalías de los Vasos Coronarios/complicaciones , Muerte Súbita Cardíaca/etiología , Resultado Fatal , Humanos , Masculino , Factores de RiesgoRESUMEN
OBJECTIVE: Two different strategies have emerged in the initial palliation for hypoplastic left heart syndrome, the conventional Norwood operation and the so-called hybrid procedure. We have used each of these at our center. The purpose of the present study was to compare the outcomes of both procedures. METHODS: From 2007 to 2012, 40 patients presented to the Cardinal Glennon Children's Medical Center with hypoplastic left heart syndrome or 1 of its variants. Of the 40 patients, 24 underwent a hybrid procedure and 16 a Norwood procedure for initial palliation. The medical records, echocardiograms, and cardiac catheterization data were retrospectively reviewed. Standard statistical analysis was performed. RESULTS: The patients who underwent the hybrid procedure weighed less than those who underwent the Norwood procedure. Overall unadjusted survival was better in the Norwood group, although this did not reach statistical significance. Overall hospital resource usage was similar in both cohorts, taking into account both first and second palliation stages. CONCLUSIONS: In our review, we found no statistically significant difference in survival or resource usage between those patients undergoing the Norwood procedure and those undergoing a hybrid procedure as initial palliation for hypoplastic left heart syndrome.
Asunto(s)
Implantación de Prótesis Vascular , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Procedimientos de Norwood , Arteria Pulmonar/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Peso Corporal , Femenino , Recursos en Salud/estadística & datos numéricos , Hemodinámica , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico , Síndrome del Corazón Izquierdo Hipoplásico/mortalidad , Síndrome del Corazón Izquierdo Hipoplásico/fisiopatología , Recién Nacido , Ligadura , Masculino , Missouri , Procedimientos de Norwood/efectos adversos , Procedimientos de Norwood/mortalidad , Cuidados Paliativos , Selección de Paciente , Arteria Pulmonar/crecimiento & desarrollo , Arteria Pulmonar/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVES: Our aim was to determine key characteristics of stents commonly implanted in the aorta through bench testing and to describe our technique and acute results in patients weighing <30 kg. BACKGROUND: Despite the increasing use of stents for interventional treatment for coarctation of the aorta (CoA) in larger patients, use of large stents is controversial in small children. METHODS: Methods included bench testing of large stents, and retrospective review of all patients over 1 year of age who had stent implantation for treatment of CoA. Patients were divided into 2 groups based on weight. Paired comparisons were made before and after stent implantation, and group outcomes were compared. RESULTS: Sixty patients comprised the entire sample, with 22 patients assigned to group I (<30 kg) and 38 patients assigned to group II (>or=30 kg). The mean minimum diameters of the CoA (group I 5.0 to 10.7 mm; group II 8.0 to 15.0 mm) and the ratio of the coarctation diameter to the descending aorta diameter measured at the level of the diaphragm (CoA/DAo ratio) (group I 0.4 to 0.93; group II 0.46 to 0.94) increased significantly in both groups (all p < 0.05). The mean systolic gradient decreased significantly in both groups (group I 23.0 to 2.0 mm Hg; group II 24.0 to 2.8 mm Hg; both p = 0.001). No difference was found between the groups in the CoA/DAo ratio, residual systolic gradients, or the decrease in systolic gradient after stent implantation. There were no significant complications in patients under 30 kg. CONCLUSIONS: As in larger patients, use of large stents for treatment of CoA in small children is effective and safe in the short term. In these patients, stent redilations will be required, and follow-up is ongoing.
Asunto(s)
Angioplastia de Balón/instrumentación , Coartación Aórtica/terapia , Peso Corporal , Selección de Paciente , Stents , Angioplastia de Balón/efectos adversos , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/fisiopatología , Aortografía , Niño , Preescolar , Femenino , Hemodinámica , Humanos , Lactante , Masculino , Ensayo de Materiales , Diseño de Prótesis , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
Herein, we describe a technique that facilitates percutaneous vascular access when the traditional method of achieving access is unsuccessful. For multiple reasons, gaining access to small vessels in pediatric patients is sometimes difficult. In instances of atrial, ventricular, or great arterial communications, a wire can be positioned from a vein or artery across the communications into an artery or vein to which access needs to be gained. This wire then serves as a target for vascular access. All pediatric patients who underwent cardiac catheterization at Mattel Children's Hospital from July 2003 through June 2006, and at Rady Children's Hospital from July through December 2006, were considered for the wire-target technique when access could not be achieved in vessels of interest via traditional methods. Fifteen wire-target procedures were undertaken in 14 patients (ages, 4 d-11 yr). By use of a directional catheter, a Wholey or 0.014-inch coronary wire was positioned in a vessel to which access was desired. Anterior-posterior and lateral fluoroscopic views were used to target the wire and attain vascular access. The patients' diagnoses, ages, vessels to which access was gained via traditional methods and via the wire-target technique, and wire routes were retrospectively recorded, and outcomes were noted. In all instances, the technique was performed successfully and without complications. In selected pediatric patients in whom percutaneous vascular access is difficult, the wire-target technique may be used safely and effectively to establish arterial, venous, or transhepatic access.
Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , California , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Angiografía Coronaria , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Radiografía Intervencional , Estudios Retrospectivos , Factores de TiempoRESUMEN
Surgical shunts are the basic form of palliation for many types of congenital heart disease. The Glenn shunt (superior cavopulmonary connection) and central shunt (aortopulmonary connection) represent surgical interventions that could potentially be accomplished by transcatheter techniques. We sought to investigate the efficacy of using neodymium iron boron (NdFeB) magnetic catheters to create transcatheter cavopulmonary and aortopulmonary shunts. NdFeB magnets were machined and integrated into catheters. "Target" catheters were placed in the pulmonary arteries (PAs), and radiofrequency "perforation" catheters were placed in either the descending aorta (DAo) for central shunts or the superior vena cava (SVC) for Glenn shunts. The magnet technique or "balloon target" method was used to pass wires from the DAo or the SVC into the PA. Aortopulmonary and cavopulmonary connections were then created using Atrium iCAST covered stents. Magnet catheters were used to perforate the left pulmonary artery from the DAo, thereby establishing a transcatheter central shunt. Given the orientation of the vasculature, magnetic catheters could not be used for SVC-to-PA connections; however, perforation from the SVC to the right pulmonary artery was accomplished with a trans-septal needle and balloon target. Transcatheter Glenn or central shunts were successfully created in four swine.
Asunto(s)
Aorta/cirugía , Derivación Arteriovenosa Quirúrgica , Puente Cardíaco Derecho/instrumentación , Arteria Pulmonar/cirugía , Animales , Cateterismo/instrumentación , Estudios de Factibilidad , Modelos Animales , PorcinosRESUMEN
Interventionalists in many specialties have the need for improved, low profile covered stents. Thin films of nitinol (<5-10 microns) could be used to improve current covered stent technology. A "hot target" sputter deposition technique was used to create thin films of nitinol for this study. Covered stents were created from commercially available balloon-inflatable and self-expanding stents. Stents were deployed in a laboratory flow loop and in four swine. Uncovered stent portions served as controls. Postmortem examinations were performed 2-6 weeks after implantation. In short-term testing, thin film nitinol covered stents deployed in the arterial circulation showed no intimal proliferation and were easily removed from the arterial wall postmortem. Scanning electron microscopy showed a thin layer of endothelial cells on the thin film, which covered the entire film by 3 weeks. By contrast, significant neointimal hyperplasia occurred on the luminal side of stents deployed in the venous circulation. Extremely low-profile covered stents can be manufactured using thin films of nitinol. Although long-term studies are needed, thin film nitinol may allow for the development of low-profile, nonthrombogenic covered stents.
Asunto(s)
Aleaciones , Materiales Biocompatibles Revestidos , Stents , Angioplastia Coronaria con Balón , Animales , Aorta Torácica , Fenómenos Biomecánicos , Ingeniería Biomédica , Rastreo Diferencial de Calorimetría , Diseño de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Sus scrofa , Resistencia a la Tracción , Vena Cava Inferior , Vena Cava SuperiorRESUMEN
OBJECTIVE: Pulmonary arteriovenous malformations (PAVM) develop in patients with a lung deprived of hepatic blood flow. Unidirectional Fontan patients have superior vena cava (SVC) blood directed to the left or right pulmonary artery (PA), and inferior vena cava (IVC) and hepatic blood baffled to the contra-lateral PA. Cyanosis often develops due to PAVM in the lung deprived of hepatic blood. We report experiences with transcatheter PA reconnection in patients with unidirectional Fontan and PAVM. DESIGN: Patients with unidirectional Fontan, cyanosis, and PAVM underwent transcatheter PA reconnection. Following simultaneous injection of contrast into PAs, a transseptal needle was used to puncture from one PA to the other. A balloon-mounted, uncovered stent was positioned bridging the pulmonary arteries. The procedure provided a nonrestrictive, permanent communication between the PAs. Results were retrospectively reviewed. Catheterization data and oxygen saturations before and after procedure were analyzed. RESULTS: Six patients with a median age of 14 years (range 13-35 years) were identified. All patients had functional single ventricle with unidirectional Fontan and PAVM in the lung supplied solely by SVC flow. The reconnection procedure was performed successfully without complications in all cases. The median follow-up time for all 6 patients was 12.8 months (range 5.8-19.3 months). Median oxygen saturation was 0.86 (range 0.81-0.92) prior to the procedure, and 0.95 (range 0.92-0.98) on follow-up, with a median increase of 9% (range 8-11%). CONCLUSION: Patients with unidirectional Fontan and PAVM demonstrate increased oxygen saturations following reconnection of PAs, suggesting regression of PAVM. This procedure can be performed safely using uncovered stents, and it is effective in improving systemic oxygen saturations.
Asunto(s)
Malformaciones Arteriovenosas/terapia , Cateterismo Cardíaco , Procedimiento de Fontan/efectos adversos , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Stents , Adolescente , Adulto , Malformaciones Arteriovenosas/diagnóstico por imagen , Malformaciones Arteriovenosas/etiología , Cineangiografía , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Masculino , Oxígeno/sangre , Inducción de Remisión , Resultado del TratamientoRESUMEN
OBJECTIVE: The aim of this study is to report our experience using the Amplatzer Duct Occluder (ADO) for occlusion of significant coronary artery fistulae (CAF). BACKGROUND: Transcatheter closure of CAF with coils is well described. Use of newer devices may offer advantages such as improved control of device placement, use of a single instead of multiple devices, and high rates of occlusion. METHODS: A retrospective review of all patients catheterized for CAF from July 2002 through August 2005 was performed. RESULTS: Thirteen patients with CAF underwent cardiac catheterization, of which a total of 6 patients had ADO placement in CAF (age, 21 days to 56 years; median age, 4.3 years and weight, 3.8 kg to 74.6 kg; median weight, 13.3 kg). An arteriovenous wire loop was used to advance a long sheath antegrade to deploy the ADO in the CAF. Immediate and short-term outcomes (follow-up, 3 months to 14 months; median follow-up, 8.5 months) demonstrated complete CAF occlusion in 5 patients and minimal residual shunt in 1 patient (who had resolution of right atrial and right ventricular enlargement). On follow-up clinical evaluation, all 6 patients had absence of fistula-related murmurs, and 2 previously symptomatic patients had resolution of congestive heart failure symptoms. Early complications included transient palpitations and atrial arrhythmia in the 2 oldest patients (52 and 56 years old). CONCLUSIONS: Use of the ADO is applicable for transcatheter closure of significant CAF. Advantages of using the ADO include the antegrade approach, use of a single device, and effective CAF occlusion.