Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
Eur J Prev Cardiol ; 29(2): 312-320, 2022 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-33624046

RESUMEN

AIMS: To evaluate the impact of various smoking status on 10-year all-cause mortality and to examine a relative treatment benefit of coronary artery bypass grafting (CABG) vs. percutaneous coronary intervention (PCI) according to smoking habits. METHODS AND RESULTS: The SYNTAX Extended Survival study evaluated vital status up to 10 years in 1800 patients with de novo three-vessel disease and/or left main coronary artery disease randomized to CABG or PCI in the SYNTAX trial. In the present analysis, patients were divided into three groups (current, former, or never smokers), and the primary endpoint of 10-year all-cause mortality was assessed according to smoking status. Smoking status was available in 1793 (99.6%) patients at the time of randomization, of whom 363 were current smokers, 798 were former smokers, and 632 were never smokers. The crude rates of 10-year all-cause mortality were 29.7% in current smokers, 25.3% in former smokers, and 25.9% in never smokers (Log-rank P = 0.343). After adjustment for imbalances in baseline characteristics, current smokers had a significantly higher risk of 10-year all-cause mortality than never smokers [adjusted hazard ratio (aHR): 2.29; 95% confidence interval (CI): 1.60-3.27; P < 0.001], whereas former smokers did not. PCI was associated with a higher risk of all-cause mortality than CABG among current smokers (HR: 1.60; 95% CI: 1.09-2.35; P = 0.017), but it failed to show a significant interaction between revascularization strategies and smoking status (Pinteraction = 0.910). CONCLUSION: Current smokers had a higher adjusted risk of 10-year all-cause mortality, whereas former smokers did not. The treatment effect of CABG vs. PCI did not differ significantly according to smoking status. CLINICAL TRIAL REGISTRATION: SYNTAX: ClinicalTrials.gov reference: NCT00114972; SYNTAX Extended Survival. ClinicalTrials.gov reference: NCT03417050.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/efectos adversos , Fumar/efectos adversos , Resultado del Tratamiento
2.
Lancet ; 394(10206): 1325-1334, 2019 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-31488373

RESUMEN

BACKGROUND: The Synergy between PCI with Taxus and Cardiac Surgery (SYNTAX) trial was a non-inferiority trial that compared percutaneous coronary intervention (PCI) using first-generation paclitaxel-eluting stents with coronary artery bypass grafting (CABG) in patients with de-novo three-vessel and left main coronary artery disease, and reported results up to 5 years. We now report 10-year all-cause death results. METHODS: The SYNTAX Extended Survival (SYNTAXES) study is an investigator-driven extension of follow-up of a multicentre, randomised controlled trial done in 85 hospitals across 18 North American and European countries. Patients with de-novo three-vessel and left main coronary artery disease were randomly assigned (1:1) to the PCI group or CABG group. Patients with a history of PCI or CABG, acute myocardial infarction, or an indication for concomitant cardiac surgery were excluded. The primary endpoint of the SYNTAXES study was 10-year all-cause death, which was assessed according to the intention-to-treat principle. Prespecified subgroup analyses were performed according to the presence or absence of left main coronary artery disease and diabetes, and according to coronary complexity defined by core laboratory SYNTAX score tertiles. This study is registered with ClinicalTrials.gov, NCT03417050. FINDINGS: From March, 2005, to April, 2007, 1800 patients were randomly assigned to the PCI (n=903) or CABG (n=897) group. Vital status information at 10 years was complete for 841 (93%) patients in the PCI group and 848 (95%) patients in the CABG group. At 10 years, 248 (28%) patients had died after PCI and 212 (24%) after CABG (hazard ratio 1·19 [95% CI 0·99-1·43], p=0·066). Among patients with three-vessel disease, 153 (28%) of 546 had died after PCI versus 114 (21%) of 549 after CABG (hazard ratio 1·42 [95% CI 1·11-1·81]), and among patients with left main coronary artery disease, 95 (27%) of 357 had died after PCI versus 98 (28%) of 348 after CABG (0·92 [0·69-1·22], pinteraction=0·023). There was no treatment-by-subgroup interaction with diabetes (pinteraction=0·60) and no linear trend across SYNTAX score tertiles (ptrend=0·20). INTERPRETATION: At 10 years, no significant difference existed in all-cause death between PCI using first-generation paclitaxel-eluting stents and CABG. However, CABG provided a significant survival benefit in patients with three-vessel disease, but not in patients with left main coronary artery disease. FUNDING: German Foundation of Heart Research (SYNTAXES study, 5-10-year follow-up) and Boston Scientific Corporation (SYNTAX study, 0-5-year follow-up).


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Anciano , Enfermedad de la Arteria Coronaria/patología , Stents Liberadores de Fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 94(3): 334-341, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30597737

RESUMEN

BACKGROUND: The ION Study assessed clinical outcomes for the thin-strut, ION™ (TAXUS Element) Paclitaxel-Eluting Platinum Chromium Coronary Stent System (Boston Scientific, Marlborough, MA) in unselected patients. METHODS: This prospective, open-label registry enrolled the first 1,120 consenting patients treated with the ION stent without clinical or angiographic inclusion criteria at 40 clinical sites. Follow-up was at discharge, 30 days, 180 days, 1 and 2 years. The primary endpoint, the 1-year rate of cardiac death or MI (CD/MI) in PERSEUS-like patients (i.e., patients similar to those enrolled in PERSEUS, the pivotal approval trial), was tested in patients pooled from the ION study (N = 316), the European TAXUS Element post-approval registry (TE-PROVE; N = 306 PERSEUS-like patients), and the PERSEUS WH/SV populations (N = 1,166); and then compared with a prespecified performance goal. Additional outcomes were examined in the overall ION patient population. RESULTS: A total of 1,111 (out of 1,120) enrolled patients received a study stent. Most patients were male (70%) and mean age was 64 years. At 1 year, the primary endpoint of CD/MI occurred in 2.1% (6/292) of PERSEUS-like patients in ION, and 2.3% (40/1,729) of patients in the combined analysis. The upper one-sided 95% confidence interval for the combined analysis was 2.9%, which was significantly less than the performance goal of 7.6% (P < 0.001). Within patients enrolled in the ION study (N = 1,111), the rate of CD/MI was 4.5% at 1 year and 7.5% at 2 years. Definite/probable stent thrombosis occurred in 2.1% of patients at 1 year and 2.5% at 2 years. CONCLUSIONS: The results of the ION Study confirm the mid-term safety and effectiveness of the ION stent for the treatment of coronary artery disease in everyday clinical practice.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Platino (Metal) , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
4.
JAMA ; 319(1): 27-37, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29297076

RESUMEN

Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur. Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR. Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017. Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305). Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set. Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%). Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Bioprótesis , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
EuroIntervention ; 13(14): 1670-1679, 2018 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-28846542

RESUMEN

AIMS: Drug-eluting stents (DES) have evolved to using bioresorbable polymers as a method of drug delivery. The impact of bioresorbable polymer on long-term neointimal formation, inflammation, and healing has not been fully characterised. This study aimed to evaluate the biological effect of polymer resorption on vascular healing and inflammation. METHODS AND RESULTS: A comparative DES study was performed in the familial hypercholesterolaemic swine model of coronary stenosis. Permanent polymer DES (zotarolimus-eluting [ZES] or everolimus-eluting [EES]) were compared to bioresorbable polymer everolimus-eluting stents (BP-EES) and BMS. Post implantation in 29 swine, stents were explanted and analysed up to 180 days. Area stenosis was reduced in all DES compared to BMS at 30 days. At 180 days, BP-EES had significantly lower area stenosis than EES or ZES. Severe inflammatory activity persisted in permanent polymer DES at 180 days compared to BP-EES or BMS. Qualitative para-strut inflammation areas (graded as none to severe) were elevated but similar in all groups at 30 days, peaked at 90 days in DES compared to BMS (p<0.05) and, at 180 days, were similar between BMS and BP-EES but were significantly greater in DES. CONCLUSIONS: BP-EES resulted in a lower net long-term reduction in neointimal formation and inflammation compared to permanent polymer DES in an animal model. Further study of the long-term neointima formation deserves study in human clinical trials.


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Inflamación/prevención & control , Neointima , Intervención Coronaria Percutánea/métodos , Implantes Absorbibles/efectos adversos , Animales , Modelos Animales de Enfermedad , Stents Liberadores de Fármacos/efectos adversos , Everolimus/administración & dosificación , Polímeros , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Porcinos , Cicatrización de Heridas
6.
EuroIntervention ; 14(1): 102-111, 2018 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-29155387

RESUMEN

AIMS: The aim of this study was to investigate short-term and five-year follow-up results from patients randomised to coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI) with paclitaxel-eluting stents in the SYNTAX trial, focusing on patients with chronic kidney disease (CKD). METHODS AND RESULTS: Baseline glomerular filtration rate estimates (eGFR) were available in 1,638 patients (PCI=852 and CABG=786). The Kidney Disease: Improving Global Outcomes (KDIGO) threshold was used to define staging of CKD. At five years, death was significantly higher in patients with CKD compared to patients with normal kidney function after PCI (26.7% vs. 10.8%, p<0.001) and CABG (21.2% vs. 10.6%, p=0.005). Comparing PCI with CABG, there was a significant interaction according to kidney function for death (pint=0.017) but not the composite endpoint of death/stroke/MI (pint=0.070) or MACCE (pint=0.15). In patients with CKD, the rate of MACCE was significantly higher after PCI compared with CABG (42.1% vs. 31.5%, p=0.019), driven by repeat revascularisation (21.9% vs. 8.9%, p=0.004) and all-cause death (26.7% vs. 21.2%, p=0.14). In patients with CKD who also had diabetes, PCI versus CABG was significantly worse in terms of death/stroke/MI (47.9% vs. 24.4%, p=0.005) and all-cause death (40.9% vs. 17.7%, p=0.004). CONCLUSIONS: During a five-year follow-up, adverse event rates were comparable between PCI and CABG patients with moderate CKD but significantly higher compared to the patients with impaired or normal kidney function. The negative impact of CKD on long-term outcome following PCI appears to be stronger when compared to CABG, especially in the CKD patients with diabetes and extensive coronary disease.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Insuficiencia Renal Crónica/complicaciones , Adulto , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Diabetes Mellitus/cirugía , Stents Liberadores de Fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
7.
JACC Cardiovasc Interv ; 10(23): 2392-2400, 2017 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-29217001

RESUMEN

OBJECTIVES: The authors sought to evaluate the final 5-year safety and effectiveness of the platinum-chromium everolimus-eluting stent (PtCr-EES) in the randomized trial, as well as in 2 single-arm substudies that evaluated PtCr-EES in small vessels (diameter <2.5 mm; n = 94) and long lesions (24 to 34 mm; n = 102). BACKGROUND: In the multicenter, randomized PLATINUM (PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions), the PtCr-EES was noninferior to the cobalt-chromium everolimus-eluting stent (CoCr-EES) at 1 year in 1,530 patients undergoing percutaneous coronary intervention. METHODS: Patients with 1 or 2 de novo coronary artery lesions (reference vessel diameter 2.50 to 4.25 mm, length ≤24 mm) were randomized 1:1 to PtCr-EES versus CoCr-EES. All patients in the substudies received PtCr-EES. The primary endpoint was target lesion failure (TLF), a composite of target vessel-related cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: In the randomized trial, the 5-year TLF rate was 9.1% for PtCr-EES and 9.3% for CoCr-EES (hazard ratio [HR]: 0.97; p = 0.87). Landmark analysis demonstrated similar TLF rates from discharge to 1 year (HR: 1.12; p = 0.70) and from 1 to 5 years (HR: 0.90; p = 0.63). There were no significant differences in the rates of cardiac death, myocardial infarction, target lesion or vessel revascularization, or stent thrombosis. PtCr-EES had 5-year TLF rates of 7.0% in small vessels and 13.6% in long lesions. CONCLUSIONS: PtCr-EES demonstrated comparable safety and effectiveness to CoCr-EES through 5 years of follow-up, with low rates of stent thrombosis and other adverse events. The 5-year event rates were also acceptable in patients with small vessels and long lesions treated with PtCr-EES. (The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions [PLATINUM]; NCT00823212; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions in Small Vessels [PLATINUM SV]; NCT01498692; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of Long De Novo Coronary Artery Lesions [PLATINUM LL]; NCT01500434).


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Anciano , Asia , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
8.
EuroIntervention ; 13(10): 1210-1217, 2017 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-28741576

RESUMEN

AIMS: The EVOLVE China randomised study sought to evaluate the clinical safety and effectiveness of the SYNERGY bioabsorbable polymer-coated everolimus-eluting stent (EES) for the treatment of patients with coronary heart disease in China. METHODS AND RESULTS: Eligible patients with de novo native coronary artery lesions were randomised (1:1) to receive the SYNERGY or PROMUS Element Plus stent. The primary endpoint was in-stent late loss at nine months. Secondary endpoints included death, MI, revascularisation, and stent thrombosis up to 12 months. A total of 412 subjects were randomised (205 SYNERGY; 207 PROMUS Element Plus) at 14 sites in China from October 2013 to July 2014. SYNERGY was non-inferior to PROMUS Element Plus for the primary endpoint of nine-month in-stent late loss: SYNERGY 0.20±0.33 mm vs. PROMUS Element Plus 0.17±0.38 mm with an upper one-sided 97.5% confidence interval of the difference (0.10 mm), significantly less than the non-inferiority margin (0.15 mm; p<0.0008). Clinical adverse event rates were low and not significantly different between groups at nine and 12 months (all p>0.05). CONCLUSIONS: In the EVOLVE China trial, the SYNERGY bioabsorbable polymer-coated EES was noninferior to the PROMUS Element Plus permanent polymer-coated EES for the primary endpoint of late loss at nine months.


Asunto(s)
Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Intervención Coronaria Percutánea , Adolescente , Adulto , Anciano , China , Cromo , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Platino (Metal) , Polímeros/efectos adversos , Sirolimus/uso terapéutico , Resultado del Tratamiento , Adulto Joven
9.
Eur Heart J ; 38(45): 3359-3366, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28651336

RESUMEN

AIMS: RESPOND is a prospective, open-label, single-arm study evaluating the outcomes following transcatheter aortic valve implantation (TAVI) with the repositionable and fully retrievable Lotus Valve used in routine clinical practice for the treatment of patients with aortic valve stenosis. METHODS AND RESULTS: RESPOND enrolled 1014 patients at sites across Europe, New Zealand, and Latin America; 996 patients received a Lotus Valve (mean age: 80.8 years; 50.8% female; Society of Thoracic Surgeons score: 6.0 ± 6.9). Repositioning was attempted in 29.2% of patients, with 99% success. The rate of all-cause mortality in the intent-to-treat population at 30 days (primary endpoint) was 2.6% (P < 0.001 vs. pre-specified performance goal). Thirty-day clinical follow-up was completed for 97.3% of patients. Among patients who received a Lotus Valve, the 30-day overall and disabling stroke rates were 3.0% and 2.2%, respectively. The 30-day permanent pacemaker implantation rate was 30.0% in all patients, and 34.6% in pacemaker-naïve patients. Echocardiographic data at baseline and pre-discharge were assessed by an independent core laboratory. Mean aortic valve gradient declined from 37.7 ± 15.2 mmHg at baseline to 10.8 ± 4.6 mmHg at hospital discharge (P < 0.001). Aortic valve area increased from 0.7 ± 0.2 cm2 at baseline to 1.8 ± 0.4 cm2 at discharge (P < 0.001). At hospital discharge, paravalvular leak (PVL) was absent or trace in 92% of patients; no patients had severe PVL, 0.3% of patients exhibited moderate PVL, and 7.7% of patients had mild PVL. Clinical follow-up in RESPOND will extend to 5 years. CONCLUSION: The results of RESPOND confirm the safety and efficacy of TAVI with the Lotus Valve in routine clinical practice. TRIAL REGISTRATION: ClinicalTrials.gov #NCT 02031302.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Medición de Resultados Informados por el Paciente , Seguridad del Paciente , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Calidad de Vida , Sistema de Registros , Reoperación/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
EuroIntervention ; 13(7): 788-795, 2017 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-28555592

RESUMEN

AIMS: The REPRISE IIE trial aimed to evaluate outcomes following transcatheter aortic valve implantation of the fully repositionable and retrievable LOTUS valve with a unique seal designed to minimise paravalvular leak (PVL). METHODS AND RESULTS: This prospective, multicentre study enrolled 250 patients with severe aortic stenosis considered high-risk for surgery by a multidisciplinary Heart Team. An independent clinical events committee adjudicated events per Valve Academic Research Consortium criteria. Mean age was 84 years; 77% were in NYHA Class III/IV. LOTUS valve implantation produced significant haemodynamic improvements at one year without valve embolisation, ectopic valve deployment, or additional valve implantation. Primary endpoints were met as the 30-day mortality rate in the extended cohort (4.4%, N=250), and mean valve gradient in the main cohort (11.5±5.2 mmHg, N=120) were below (p<0.001) their predefined performance objectives. At 30 days, disabling stroke was 2.8% and new pacemaker implantation was 28.9% in all patients and 32.0% in pacemaker-naïve patients. By one year, all-cause mortality was 11.6%, disabling stroke was 3.6%, 95% of patients alive were in NYHA Class I/II, and there was no core laboratory-adjudicated moderate/severe PVL. CONCLUSIONS: LOTUS valve implantation produced good valve haemodynamics, minimal PVL, sustained significant improvement in functional status, and good clinical outcomes one year post implant.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Bioprótesis , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis/métodos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
11.
Am J Cardiol ; 120(2): 292-299, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28535962

RESUMEN

Paravalvular leak (PVL) after transcatheter aortic valve replacement is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative Adaptive Seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL after implantation of the Lotus transcatheter aortic valve. The REPRISE II (REpositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Evaluation of Safety and Performance) Study With Extended Cohort enrolled 250 high-surgical risk patients with severe symptomatic aortic stenosis. Aortic regurgitation was assessed by echocardiography pre-procedure, at discharge and 30 days, by an independent core laboratory. Baseline and procedural predictors of mild or greater PVL at 30 days (or at discharge if 30-day data were not available) were determined using a multivariate regression model (n = 229). Of the 229 patients, 197 (86%) had no/trace PVL, 30 had mild, and 2 had moderate PVL; no patient had severe PVL. Significant predictors of mild/moderate PVL included device:annulus area ratio (odds ratio [OR] 0.87; 95% CI 0.83 to 0.92; p <0.001), left ventricular outflow tract calcium volume (OR 2.85; 95% CI 1.44 to 5.63; p = 0.003), and annulus area (OR 0.89; 95% CI 0.82 to 0.96; p = 0.002). When the device:annulus area ratio was <1, the rate of mild/moderate PVL was 53.1% (17 of 32). The rates of mild/moderate PVL with 0% to 5%, 5% to 10%, and >10% annular oversizing by area were 17.5% (11 of 63), 2.9% (2 of 70), and 3.2% (2 of 63), respectively. Significant independent predictors of PVL included device:annulus area ratio and left ventricular outflow tract calcium volume. When the prosthetic valve was oversized by ≥5%, the rate of mild or greater PVL was only 3%. In conclusion, the overall rates of PVL with the Lotus Valve are low and predominantly related to device/annulus areas and calcium; these findings have implications for optimal device sizing.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Pronóstico , Diseño de Prótesis , Falla de Prótesis , Índice de Severidad de la Enfermedad
12.
Eur J Cardiothorac Surg ; 52(3): 445-453, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28520861

RESUMEN

OBJECTIVES: To examine differences among participating countries in baseline characteristics, clinical practice, medication strategies and outcomes of patients randomized to coronary artery bypass grafting and percutaneous coronary intervention in the SYNTAX trial. METHODS: In SYNTAX, centres in 18 different countries enrolled 1800 patients, of which 8 countries enrolled ≥80 patients, what was projected to be a large enough sample size to be included in the analysis. Baseline characteristics, practice patterns and clinical outcomes were compared between the USA (n = 245), the UK (n = 267), Italy (n = 197), France (n = 208), Germany (n = 179), Netherlands (n = 148), Belgium (n = 91) and Hungary (n = 83). The remaining patients from other participating countries were pooled together (n = 382). RESULTS: Five-year results demonstrated significantly different outcomes between countries. After adjustment, percutaneous coronary intervention patients in France had lower rates of major adverse cardiac and cerebrovascular events [hazard ratio (HR) = 0.60, 95% confidence interval (CI) 0.37-0.98], while the incidence of repeat revascularization was higher in Hungary (HR = 1.89, 95% CI 1.14-3.42). Coronary artery bypass grafting showed the lowest rate of repeat revascularization in the UK (HR = 0.32, 95% CI 0.12-0.85). There were numerous differences in the risk profile of patients between participating countries, as well as marked differences in surgical practice across countries in the use of blood cardioplegia (range 3.1-89.0%; P < 0.001), bilateral internal mammary artery usage (range 7.8-68.2%; P < 0.001) and off-pump procedures (range 3.9-44.4%; P < 0.001). Variation was also found for percutaneous coronary intervention in the number of implanted stents (range 4.0 ± 2.3 to 6.1 ± 2.6; P < 0.001) as well as for the entire stents length (range 69.0 ± 45.1 to 124.1 ± 60.9; P < 0.001). Remarkable differences were observed in the prescription of post-coronary artery bypass grafting medication in terms of acetylsalicylic acid (range 79.6-95.0%; P = 0.004), thienopyridine (6.8-31.1%; P < 0.001) and statins (41.3-89.1%; P < 0.001). CONCLUSIONS: Patient characteristics and clinical patterns are significantly different between countries, resulting in significantly different 5-year outcomes. This article presents specific data that can further improve outcomes in each country. CLINICAL TRIALS REGISTRY: NCT00114972.


Asunto(s)
Puente de Arteria Coronaria/normas , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/normas , Complicaciones Posoperatorias/epidemiología , Pautas de la Práctica en Medicina , Mejoramiento de la Calidad , Anciano , Antineoplásicos Fitogénicos/farmacología , Stents Liberadores de Fármacos , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/farmacología , Factores de Tiempo , Estados Unidos/epidemiología
13.
EuroIntervention ; 13(7): 796-803, 2017 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-28506942

RESUMEN

AIMS: This analysis aimed to evaluate the incidence and predictors of the need for permanent pacemaker (PPM) implantation following implantation of the repositionable and fully retrievable LOTUS Aortic Valve Replacement System. METHODS AND RESULTS: The prospective, single-arm, multicentre REPRISE II study with extended cohort enrolled 250 symptomatic, high surgical risk patients with severe aortic stenosis for transfemoral transcatheter aortic valve implantation (TAVI) with a 23 mm or 27 mm LOTUS valve. Echocardiography, computed tomography, and electrocardiography data were evaluated by independent core labs. Post TAVI, 32.0% (72/225) of pacemaker-naïve patients underwent new PPM implantation at 30 days. Most (59/72, 82%) patients were implanted for third-degree atrioventricular block, and >10% overstretch of the LVOT by area was observed in 59.7% (43/72) of PPM patients. Significant independent predictors of PPM at 30 days included baseline RBBB (odds ratio [OR] 12.7, 95% CI: 4.5, 36.2; p<0.001) and LVOT overstretch >10% (OR 3.4, 95% CI: 1.7, 6.7; p<0.001). There was a trend towards a lower 30-day PPM rate in patients with a shallower (≤5 mm) implant depth (23.9% ≤5 mm vs. 36.9% >5 mm depth from LCS; p=0.06). CONCLUSIONS: Careful attention to valve sizing and implant depth may help to reduce the rate of PPM with the LOTUS valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
14.
EuroIntervention ; 13(7): 828-834, 2017 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-28320685

RESUMEN

AIMS: The use of multiple geographical sites for randomised cardiovascular trials may lead to important heterogeneity in treatment effects. This study aimed to determine whether treatment effects from different geographical recruitment regions impacted significantly on five-year MACCE rates in the SYNTAX trial. METHODS AND RESULTS: Five-year SYNTAX results (n=1,800) were analysed for geographical variability by site and country for the effect of treatment (CABG vs. PCI) on MACCE rates. Fixed, random, and linear mixed models were used to test clinical covariate effects, such as diabetes, lesion characteristics, and procedural factors. Comparing five-year MACCE rates, the pooled odds ratio (OR) between study sites was 0.58 (95% CI: 0.47-0.71), and countries 0.59 (95% CI: 0.45-0.73). By homogeneity testing, no individual site (X2=93.8, p=0.051) or country differences (X2=25.7, p=0.080) were observed. For random effects models, the intraclass correlation was minimal (ICC site=5.1%, ICC country=1.5%, p<0.001), indicating minimal geographical heterogeneity, with a hazard ratio of 0.70 (95% CI: 0.59-0.83). Baseline risk (smoking, diabetes, PAD) did not influence regional five-year MACCE outcomes (ICC 1.3%-5.2%), nor did revascularisation of the left main vs. three-vessel disease (p=0.241), across site or country subgroups. For CABG patients, the number of arterial (p=0.49) or venous (p=0.38) conduits used also made no difference. CONCLUSIONS: Geographic variability has no significant treatment effect on MACCE rates at five years. These findings highlight the generalisability of the five-year outcomes of the SYNTAX study.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/métodos , Factores de Riesgo , Resultado del Tratamiento
15.
EuroIntervention ; 12(16): 1987-1994, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-27840326

RESUMEN

AIMS: Bioabsorbable polymer drug-eluting stents (DES) may reduce the inflammation and delayed healing associated with some permanent polymer-coated DES. Whether late clinical outcomes are improved, particularly among patients with medically treated diabetes, is unknown. Therefore, we analysed outcomes from a pre-specified substudy of the EVOLVE II trial to evaluate the safety and effectiveness of the SYNERGY stent in patients with diabetes mellitus. METHODS AND RESULTS: SYNERGY is a thin-strut, platinum-chromium everolimus-eluting stent with an ultra-thin bioabsorbable poly(DL-lactide-co-glycolide) abluminal polymer. The EVOLVE II randomised, controlled trial proved the non-inferiority of the SYNERGY versus the PROMUS Element Plus stent for one-year target lesion failure (TLF: ischaemia-driven target lesion revascularisation [ID-TLR], target vessel myocardial infarction [TVMI], or cardiac death). The pre-specified EVOLVE II diabetes substudy prospectively pooled randomised patients with diabetes (N=263) with a sequential single-arm diabetic cohort (n=203). The substudy primary endpoint was one-year TLF compared with a pre-specified performance goal (14.5%). The primary endpoint occurred in 7.5% of SYNERGY-treated patients with diabetes, significantly less than the performance goal (p<0.0001). The two-year rate of TLF was 11.2% (cardiac death 1.5%, TVMI 6.4%, ID-TLR 6.8%) and definite/probable stent thrombosis occurred in 1.1% of patients. CONCLUSIONS: The EVOLVE II diabetes substudy demonstrates the efficacy and safety of the SYNERGY stent in patients with medically treated diabetes.


Asunto(s)
Implantes Absorbibles , Complicaciones de la Diabetes , Diabetes Mellitus , Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Infarto del Miocardio/cirugía , Sirolimus/uso terapéutico , Implantes Absorbibles/efectos adversos , Anciano , Anciano de 80 o más Años , Muerte , Stents Liberadores de Fármacos/efectos adversos , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/métodos , Polímeros/efectos adversos , Resultado del Tratamiento
16.
JACC Cardiovasc Interv ; 9(24): 2493-2507, 2016 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-28007201

RESUMEN

OBJECTIVES: The study sought to determine the incidence, predictors, characteristics, and outcomes of repeat revascularization during 5-year follow-up of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery) trial. BACKGROUND: Limited in-depth long-term data on repeat revascularization are available from randomized trials comparing percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). METHODS: Incidence and timing of repeat revascularization and its relation to the long-term composite safety endpoint of death, stroke, and myocardial infarction were analyzed in the SYNTAX trial (n = 1,800) using Kaplan-Meier analysis. RESULTS: At 5 years, repeat revascularization occurred more often after initial PCI than after initial CABG (25.9% vs. 13.7%, respectively; p < 0.001), and more often consisted of multiple repeat revascularizations (9.0% vs. 2.8%, respectively; p = 0.022). Significantly more repeat PCI procedures were performed on de novo lesions in patients after initial PCI than initial CABG (33.3% vs. 13.4%, respectively; p < 0.001). At 5-year follow-up, patients who underwent repeat revascularization versus patients not undergoing repeat revascularization had significantly higher rates of the composite safety endpoint of death, stroke, and myocardial infarction after initial PCI (33.8% vs. 16.6%, respectively; p < 0.001), and a trend was found after initial CABG (22.4% vs. 15.8%, respectively; p = 0.07). After multivariate adjustment, repeat revascularization was an independent predictor of the composite safety endpoint after both initial PCI (hazard ratio [HR]: 2.2; 95% confidence interval [CI]: 1.6 to 3.0; p < 0.001) and initial CABG (HR: 1.8; 95% CI: 1.2 to 2.9; p = 0.011). CONCLUSIONS: Repeat revascularization rates are significantly higher after initial PCI than after initial CABG for complex coronary disease. Repeat revascularization is an independent predictor of death, stroke, and myocardial infarction for myocardial revascularization.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea , Anciano , Distribución de Chi-Cuadrado , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Retratamiento , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
17.
EuroIntervention ; 12(6): 790-7, 2016 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-27542793

RESUMEN

AIMS: Our aim was to evaluate arterial responses to paclitaxel and a novel fluorocopolymer-coated nitinol low-dose paclitaxel-eluting stent (FP-PES). METHODS AND RESULTS: Human smooth muscle cell (SMC) migration was assessed after exposure to paclitaxel in vitro. For pharmacokinetics and vascular response, FP-PES or bare metal stents (BMS) were implanted in porcine iliofemoral arteries. Paclitaxel significantly inhibited human coronary and femoral artery SMC migration at doses as low as 1 pM. Inhibition was significantly greater for femoral compared with coronary artery SMCs from 1 pM to 1 µM. Pharmacokinetics showed consistent paclitaxel release from FP-PES over the study duration. The peak arterial wall paclitaxel level was 3.7 ng/mg at 10 days, with levels decreasing to 50% of peak at 60 days and 10% at 180 days. Paclitaxel was not detected in blood or remote organs. Arteriogram and histomorphometry analyses showed FP-PES significantly inhibits neointimal proliferation versus BMS at 30 and 90 days. Re-endothelialisation scores were not different between groups. CONCLUSIONS: Paclitaxel affected femoral artery SMC migration at lower concentrations and to a greater degree than it did coronary artery SMCs. The novel FP-PES used in this preclinical study demonstrated a vascular healing response similar to BMS, while significantly inhibiting neointimal formation up to 90 days.


Asunto(s)
Antineoplásicos Fitogénicos/administración & dosificación , Stents Liberadores de Fármacos , Miocitos del Músculo Liso/efectos de los fármacos , Paclitaxel/administración & dosificación , Aleaciones , Animales , Antineoplásicos Fitogénicos/farmacocinética , Movimiento Celular/efectos de los fármacos , Vasos Coronarios/citología , Arteria Femoral/citología , Humanos , Modelos Animales , Neointima/prevención & control , Paclitaxel/farmacocinética , Polímeros , Porcinos
18.
JACC Cardiovasc Interv ; 9(4): 376-384, 2016 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-26892084

RESUMEN

OBJECTIVES: This analysis presents the first report of 1-year outcomes of the 120 patients enrolled in the REPRISE II (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Evaluation of Safety and Performance) study. BACKGROUND: The fully repositionable and retrievable Lotus Valve (Boston Scientific, Marlborough, Massachusetts) was designed to facilitate accurate positioning, early valve function, and hemodynamic stability during deployment and to minimize paravalvular regurgitation in patients undergoing transcatheter aortic valve replacement. METHODS: The study enrolled 120 symptomatic patients 70 years of age or older at 14 centers in Australia and Europe. Patients had severe calcific aortic stenosis and were deemed to be at high or extreme risk of surgery based on assessment by the heart team. RESULTS: The mean age was 84.4 ± 5.3 years, 57% (68 of 120) of patients were women, and the mean Society of Thoracic Surgeons score was 7.1 ± 4.6. The mean baseline aortic valve area was 0.7 ± 0.2 cm(2), and the mean transvalvular pressure gradient was 46.4 ± 15.0 mm Hg. All patients were successfully implanted with a Lotus Valve, and 1-year clinical follow-up was available for 99.2% (119 of 120 of patients). The mean 1-year transvalvular aortic pressure gradient was 12.6 ± 5.7 mm Hg, and the mean valve area was 1.7 ± 0.5 cm(2). A total of 88.6% patients had no or trivial paravalvular aortic regurgitation at 1 year by independent core lab adjudication, and 97.1% of patients were New York Heart Association functional class I or II. At 1 year, the all-cause mortality rate was 10.9% (13 of 119 patients), disabling stroke rate was 3.4% (4 of 119 patients), disabling bleeding rate was 5.9% (7 of 119 patients), with no repeat procedures for valve-related dysfunction. A total of 31.9% (38 of 119 patients) underwent new permanent pacemaker implantation at 1 year. CONCLUSIONS: At 1 year of follow-up, the Lotus Valve demonstrated excellent valve hemodynamics, no moderate or severe paravalvular regurgitation, and significant and sustained improvement in New York Heart Association functional class status, with good clinical outcomes. (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Evaluation of Safety and Performance [REPRISE II]; NCT01627691).


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Calcinosis/terapia , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Australia , Calcinosis/diagnóstico , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Estimulación Cardíaca Artificial , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
19.
Am J Cardiol ; 117(4): 539-545, 2016 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-26732420

RESUMEN

The PROMUS Element Plus US Post-Approval Study (PE-Plus PAS) was a prospective, open-label, multicenter, observational study designed to examine outcomes in everyday clinical practice in patients treated with everolimus-eluting, platinum-chromium PROMUS Element Plus stents at 52 centers in the United States. This is the first report of results from this large study. The primary end point of the PE-Plus PAS was 12-month cardiac death or myocardial infarction in the more restricted population of "PLATINUM-like" patients pooled from the PE-Plus PAS, PE-PROVE (PROMUS Element European post-approval study), and PLATINUM Workhorse/Small Vessel trials. Additional clinical end points were tested in the overall PE-Plus PAS patient population. Of the 2,683 patients enrolled in PE-Plus PAS, 70% were men, mean age was 64 years, 33% had diabetes, and 29% were "PLATINUM-like." Among the PLATINUM-like patients, 12-month cardiac death or myocardial infarction was 1.8% (33 of 1,855) with an upper 1-sided 95% confidence interval of 2.3%, which was significantly less than the prespecified performance goal of 3.2% (pnoninferiority <0.001). In the overall PE-Plus population, 12-month target vessel failure (defined as death, MI, or revascularization related to the target vessel) was 6.7% (170 of 2,554), cardiac death was 1.4% (37 of 2,554), MI was 1.1% (28 of 2,554), and ARC-definite/probable stent thrombosis was 0.7% (19 of 2,554). A prespecified secondary end point of 12-month target vessel failure in diabetic patients demonstrated a rate of 4.2% (14 of 332) with an upper 1-sided 95% confidence interval of 6.03%, which was significantly less than the performance goal of 12.6% (pnoninferiority <0.001). In conclusion, in this large registry of unselected patients, coronary artery revascularization with the PROMUS Element Plus everolimus-eluting stent demonstrates favorable results with low 1-year clinical event rates.


Asunto(s)
Cromo , Enfermedad de la Arteria Coronaria/cirugía , Aprobación de Recursos , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Platino (Metal) , Sirolimus/farmacología , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
20.
J Am Coll Cardiol ; 67(1): 42-55, 2016 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-26764065

RESUMEN

BACKGROUND: There are no data available on specific causes of death from randomized trials that have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI). OBJECTIVES: The purpose of this study was to investigate specific causes of death, and its predictors, after revascularization for complex coronary disease in patients. METHODS: An independent Clinical Events Committee consisting of expert physicians who were blinded to the study treatment subclassified causes of death as cardiovascular (cardiac and vascular), noncardiovascular, or undetermined according to the trial protocol. Cardiac deaths were classified as sudden cardiac, related to myocardial infarction (MI), and other cardiac deaths. RESULTS: In the randomized cohort, there were 97 deaths after CABG and 123 deaths after PCI during a 5-year follow-up. After CABG, 49.4% of deaths were cardiovascular, with the greatest cause being heart failure, arrhythmia, or other causes (24.6%), whereas after PCI, the majority of deaths were cardiovascular (67.5%) and as a result of MI (29.3%). The cumulative incidence rates of all-cause death were not significantly different between CABG and PCI (11.4% vs. 13.9%, respectively; p = 0.10), whereas there were significant differences in terms of cardiovascular (5.8% vs. 9.6%, respectively; p = 0.008) and cardiac death (5.3% vs. 9.0%, respectively; p = 0.003), which were caused primarily by a reduction in MI-related death with CABG compared with PCI (0.4% vs. 4.1%, respectively; p <0.0001). Treatment with PCI versus CABG was an independent predictor of cardiac death (hazard ratio: 1.55; 95% confidence interval: 1.09 to 2.33; p = 0.045). The difference in MI-related death was seen largely in patients with diabetes, 3-vessel disease, or high SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries) trial scores. CONCLUSIONS: During a 5-year follow-up, CABG in comparison with PCI was associated with a significantly reduced rate of MI-related death, which was the leading cause of death after PCI. Treatments following PCI should target reducing post-revascularization spontaneous MI. Furthermore, secondary preventive medication remains essential in reducing events post-revascularization. (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972).


Asunto(s)
Puente de Arteria Coronaria , Enfermedad Coronaria/mortalidad , Enfermedad Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Causas de Muerte , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...