RESUMEN
The International Liaison Committee on Resuscitation engages in a continuous review of new, peer-reviewed, published cardiopulmonary resuscitation and first aid science. Draft Consensus on Science With Treatment Recommendations are posted online throughout the year, and this annual summary provides more concise versions of the final Consensus on Science With Treatment Recommendations from all task forces for the year. Topics addressed by systematic reviews this year include resuscitation of cardiac arrest from drowning, extracorporeal cardiopulmonary resuscitation for adults and children, calcium during cardiac arrest, double sequential defibrillation, neuroprognostication after cardiac arrest for adults and children, maintaining normal temperature after preterm birth, heart rate monitoring methods for diagnostics in neonates, detection of exhaled carbon dioxide in neonates, family presence during resuscitation of adults, and a stepwise approach to resuscitation skills training. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the quality of the evidence, using Grading of Recommendations Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations. Insights into the deliberations of the task forces are provided in the Justification and Evidence-to-Decision Framework Highlights sections. In addition, the task forces list priority knowledge gaps for further research. Additional topics are addressed with scoping reviews and evidence updates.
Asunto(s)
Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Nacimiento Prematuro , Adulto , Femenino , Niño , Recién Nacido , Humanos , Primeros Auxilios , Consenso , Paro Cardíaco Extrahospitalario/terapia , Reanimación Cardiopulmonar/métodosRESUMEN
BACKGROUND: Bronchopulmonary dysplasia (BPD), an inflammatory-mediated chronic lung disease, is common in extremely preterm infants born before 28 weeks' gestation and is associated with an increased risk of adverse neurodevelopmental and respiratory outcomes in childhood. Effective and safe prophylactic therapies for BPD are urgently required. Systemic corticosteroids reduce rates of BPD in the short term but are associated with poorer neurodevelopmental outcomes if given to ventilated infants in the first week after birth. Intratracheal administration of corticosteroid admixed with exogenous surfactant could overcome these concerns by minimizing systemic sequelae. Several small, randomized trials have found intratracheal budesonide in a surfactant vehicle to be a promising therapy to increase survival free of BPD. The primary objective of the PLUSS trial is to determine whether intratracheal budesonide mixed with surfactant increases survival free of bronchopulmonary dysplasia (BPD) at 36 weeks' postmenstrual age (PMA) in extremely preterm infants born before 28 weeks' gestation. METHODS: An international, multicenter, double-blinded, randomized trial of intratracheal budesonide (a corticosteroid) mixed with surfactant for extremely preterm infants to increase survival free of BPD at 36 weeks' postmenstrual age (PMA; primary outcome). Extremely preterm infants aged < 48 h after birth are eligible if (1) they are mechanically ventilated, or (2) they are receiving non-invasive respiratory support and there is a clinical decision to treat with surfactant. The intervention is budesonide (0.25 mg/kg) mixed with poractant alfa (200 mg/kg first intervention, 100 mg/kg if second intervention), administered intratracheally via an endotracheal tube or thin catheter. The comparator is poractant alfa alone (at the same doses). Secondary outcomes include the components of the primary outcome (death, BPD prior to or at 36 weeks' PMA), and potential systemic side effects of corticosteroids. Longer-term outcomes will be published separately, and include cost-effectiveness, early childhood health until 2 years of age, and neurodevelopmental outcomes at 2 years of age (corrected for prematurity). STATISTICAL ANALYSIS PLAN: A sample size of 1038 infants (519 in each group) is required to provide 90% power to detect a relative increase in survival free of BPD of 20% (an absolute increase of 10%), from the anticipated event rate of 50% in the control arm to 60% in the intervention (budesonide) arm, alpha error 0.05. To allow for up to 2% of study withdrawals or losses to follow-up, PLUSS aimed to enroll a total of 1060 infants (530 in each arm). The binary primary outcome will be reported as the number and percentage of infants who were alive without BPD at 36 weeks' PMA for each randomization group. To estimate the difference in risk (with 95% CI), between the treatment and control arms, binary regression (a generalized linear multivariable model with an identity link function and binomial distribution) will be used. Along with the primary outcome, the individual components of the primary outcome (death, and physiological BPD at 36 weeks' PMA), will be reported by randomization group and, again, binary regression will be used to estimate the risk difference between the two treatment groups for survival and physiological BPD at 36 weeks' PMA.
Asunto(s)
Displasia Broncopulmonar , Surfactantes Pulmonares , Humanos , Recién Nacido , Displasia Broncopulmonar/prevención & control , Budesonida , Recien Nacido Extremadamente Prematuro , TensoactivosRESUMEN
The International Liaison Committee on Resuscitation engages in a continuous review of new, peer-reviewed, published cardiopulmonary resuscitation and first aid science. Draft Consensus on Science With Treatment Recommendations are posted online throughout the year, and this annual summary provides more concise versions of the final Consensus on Science With Treatment Recommendations from all task forces for the year. Topics addressed by systematic reviews this year include resuscitation of cardiac arrest from drowning, extracorporeal cardiopulmonary resuscitation for adults and children, calcium during cardiac arrest, double sequential defibrillation, neuroprognostication after cardiac arrest for adults and children, maintaining normal temperature after preterm birth, heart rate monitoring methods for diagnostics in neonates, detection of exhaled carbon dioxide in neonates, family presence during resuscitation of adults, and a stepwise approach to resuscitation skills training. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the quality of the evidence, using Grading of Recommendations Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations. Insights into the deliberations of the task forces are provided in the Justification and Evidence-to-Decision Framework Highlights sections. In addition, the task forces list priority knowledge gaps for further research. Additional topics are addressed with scoping reviews and evidence updates.
Asunto(s)
Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Nacimiento Prematuro , Adulto , Femenino , Niño , Recién Nacido , Humanos , Primeros Auxilios , Consenso , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapiaRESUMEN
BACKGROUND: Bronchopulmonary dysplasia (BPD), an inflammatory-mediated chronic lung disease, is common in extremely preterm infants born before 28 weeks' gestation and is associated with an increased risk of adverse neurodevelopmental and respiratory outcomes in childhood. Effective and safe prophylactic therapies for BPD are urgently required. Systemic corticosteroids reduce rates of BPD in the short-term but are associated with poorer neurodevelopmental outcomes if given to ventilated infants in the first week after birth. Intratracheal administration of corticosteroid admixed with exogenous surfactant could overcome these concerns by minimizing systemic sequelae. Several small, randomized trials have found intratracheal budesonide in a surfactant vehicle to be a promising therapy to increase survival free of BPD. METHODS: An international, multicenter, double-blinded, randomized trial of intratracheal budesonide (a corticosteroid) mixed with surfactant for extremely preterm infants to increase survival free of BPD at 36 weeks' postmenstrual age (PMA; primary outcome). Extremely preterm infants aged < 48 h after birth are eligible if: (1) they are mechanically ventilated, or (2) they are receiving non-invasive respiratory support and there is a clinical decision to treat with surfactant. The intervention is budesonide (0.25 mg/kg) mixed with poractant alfa (200 mg/kg first intervention, 100 mg/kg if second intervention), administered intratracheally via an endotracheal tube or thin catheter. The comparator is poractant alfa alone (at the same doses). Secondary outcomes include the components of the primary outcome (death, BPD prior to or at 36 weeks' PMA), potential systemic side effects of corticosteroids, cost-effectiveness, early childhood health until 2 years of age, and neurodevelopmental outcomes at 2 years of age (corrected for prematurity). DISCUSSION: Combining budesonide with surfactant for intratracheal administration is a simple intervention that may reduce BPD in extremely preterm infants and translate into health benefits in later childhood. The PLUSS trial is powered for the primary outcome and will address gaps in the evidence due to its pragmatic and inclusive design, targeting all extremely preterm infants regardless of their initial mode of respiratory support. Should intratracheal budesonide mixed with surfactant increase survival free of BPD, without severe adverse effects, this readily available intervention could be introduced immediately into clinical practice. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ( https://www.anzctr.org.au ), ACTRN12617000322336. First registered on 28th February 2017.
Asunto(s)
Displasia Broncopulmonar , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Surfactantes Pulmonares , Preescolar , Recién Nacido , Lactante , Humanos , Tensoactivos , Budesonida/efectos adversos , Displasia Broncopulmonar/diagnóstico , Displasia Broncopulmonar/prevención & control , Recien Nacido Extremadamente Prematuro , Australia , Surfactantes Pulmonares/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como AsuntoRESUMEN
BACKGROUND: Many small, sick, and preterm infants are unable to co-ordinate sucking, swallowing, and breathing, and therefore require gavage feeding. In gavage feeding, milk feeds are delivered through a tube passed via the nose or the mouth into the stomach. Intermittent bolus milk feeds may be administered by a syringe to gently push milk into the infant's stomach (push feed). Alternatively, milk can be poured into a syringe attached to the tube and allowed to drip in by gravity (gravity feed). OBJECTIVES: To determine whether use of push feeding compared with gravity feeding results in more rapid establishment of full gavage feeds without increasing adverse events among preterm or low birth weight infants, or both, who require intermittent bolus tube feeding. SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2020, Issue 7), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions(R); and the Cumulative Index to Nursing and Allied Health Literature (CINAHL), on 30 July 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials (RCTs) and quasi-RCTs. SELECTION CRITERIA: We included RCTs and quasi-RCTs comparing push versus gravity intermittent gavage tube feeding in preterm (less than 37 weeks' gestation) or low birth weight (less than 2500 grams) infants, or both. DATA COLLECTION AND ANALYSIS: We assessed the methods of trials regarding blinding of randomisation and outcome measurement. We evaluated treatment effects with a fixed-effect model using risk ratio (RR), relative risk reduction, risk difference (RD), and number needed to treat for an additional beneficial outcome (NNTB) for categorical data; and using mean, standard deviation, and mean difference (MD) for continuous data. We analysed outcomes measured as count data, for example, frequency of apnoea, bradycardia, and episodes of pulse oximeter oxygen (SpO2) desaturation, by comparing rates of events and the rate ratio. We evaluated heterogeneity to help determine the suitability of pooling results. We used the GRADE approach to assess the certainty of evidence. MAIN RESULTS: One small cross-over trial (31 infants) met the criteria for inclusion in this review. The certainty of evidence for all outcomes was very low due to imprecision of estimates, wide confidence intervals, and unclear risk of bias. The primary outcome - time taken to establish full gavage feeding (days) and feeding intolerance (number of episodes per day) - was not reported in the included study. The evidence is very uncertain about the effects of push versus gravity intermittent gavage tube feeding on all other outcomes. Investigators reported respiratory rate (breaths per minute) at completion of feeding (MD 0.58, 95% confidence interval (CI) -5.97 to 7.13; 1 study, 31 participants; very low-certainty evidence); respiratory rate (breaths per minute) 10 to 30 minutes after completion of feeding (MD 3.1, 95% CI -3.43 to 9.63; 1 study, 31 participants; very low-certainty evidence); heart rate (beats per minute) at completion of feeding (MD 2.6, 95% CI -9.71 to 4.51; 1 study, 31 participants; very low-certainty evidence); and heart rate (beats per minute) 10 to 30 minutes after completion of feeding (MD 2.4, 95% CI -9.16 to 4.36; 1 study, 31 participants; very low-certainty evidence). We are very uncertain of the effects of push versus gravity intermittent gavage feeding on respiratory rate during and after feeding. AUTHORS' CONCLUSIONS: We do not have sufficient evidence to determine the effects of intermittent bolus gavage feeding for preterm and low birth weight infants. The single small study of 31 infants comparing effects of push versus gravity bolus gavage feeding did not report the primary outcome identified in this review. Thus, evidence is insufficient to show whether use of push compared with gravity gavage feeding results in more rapid establishment of full gavage feeds without increasing adverse events in preterm or low birth weight infants who receive intermittent bolus gavage feeding. In addition, the included study was too small to measure potential adverse events that can occur during gavage tube feeding, for example, episodes of oxygen desaturation, apnoea, or bradycardia.
Asunto(s)
Nutrición Enteral , Recién Nacido de Bajo Peso , Animales , Estudios Cruzados , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , LecheRESUMEN
OBJECTIVE: To perform a systematic review of trials comparing interfaces for delivering non-invasive PPV to a newborn in the delivery room (DR). METHODS: MEDLINE, PUBMED, EMBASE, CINAHL and COCHRANE databases were searched on March 1, 2020 and 2826 articles were screened. The review was conducted using the Cochrane Collaboration and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Primary outcomes were intubation in the DR and mortality. Secondary outcomes were chest compressions, intraventricular haemorrhage (IVH), necrotising enterocolitis (NEC) and mask leak. RESULTS: Five randomized-control trials were eligible for inclusion. Sample size and gestational age varied amongst the trials, ranging from 56 to 617 infants and 24-39 weeks' respectively. Three trials compared nasal cannulae (NC) with face masks (FMs). Pooled analysis showed that NC were associated with a decreased use of chest compressions (RR 0.2 (95% CI 0.08-0.47). A reduction in rate of intubation in the DR was statistically significant only in the trial in which bi-nasal rather than single nasal cannulae were used (RR 0.10, 95% CI 0.02-0.44). However, there was no important difference in mortality (RR 0.72, 95% CI 0.47-1.13). Two trials compared different FM models (Laerdal versus Fisher & Paykel and Laerdal versus Resusi-sure) and both found no significant difference in primary and secondary outcomes. CONCLUSION: There is little high-quality evidence to guide clinicians choosing an interface to provide PPV during newborn resuscitation. Nasal interfaces, particularly binasal cannulae, appear to offer some advantages over FMs but need further testing in larger, well designed trials. STUDY REGISTRATION: PROSPERO CRD42020151870.
Asunto(s)
Salas de Parto , Resucitación , Femenino , Edad Gestacional , Humanos , Recién Nacido , Intubación , EmbarazoRESUMEN
OBJECTIVE: Positive pressure ventilation (PPV) using a ventilation device and a face mask is recommended for compromised newborn infants in the delivery room (DR). Airway obstruction and face mask leak during PPV may contribute to failure of resuscitation. Using an oropharyngeal airway (OPA) may improve efficacy of mask PPV. To determine whether the use of an OPA with mask PPV in the DR during stabilization of infants <34 weeks' gestational age, reduces the incidence of airway obstruction. INTERVENTION AND MEASUREMENTS: An international two center unblinded randomized trial. Infants assessed by the clinical team to require PPV, were randomly assigned to receive PPV using a T Piece device with either a soft round face mask alone or in combination with an appropriately sized OPA. Resuscitation protocols were standardized. A hot-wire anemometer flow sensor measured respiratory function during the first five minutes of stabilization. The primary outcome was the incidence of airway obstruction, either complete (no gas flow) or partial (minimal gas flows resulting in expired tidal volumes <2â¯mL/kg). MAIN RESULTS: A total of 137 infants were enrolled. Obstructed inflations were more frequently observed in infants stabilized with an OPA (81% vs. 64%; pâ¯=â¯0.03). Partial obstruction was more common in infants stabilized with an OPA (70% vs 54%; pâ¯=â¯0.04). There were no differences in mortality or respiratory outcomes for the whole cohort or in gestational age subgroups. CONCLUSIONS: Airway obstruction is common in preterm infants receiving mask ventilation in the DR. Using an oropharyngeal airway significantly increases the incidence of airway obstruction. REGISTERED CLINICAL TRIAL: Australian and New Zealand Clinical Trials Register; ACTRN 12612000392864.
Asunto(s)
Obstrucción de las Vías Aéreas/prevención & control , Máscaras Laríngeas , Respiración con Presión Positiva/instrumentación , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Factores de Edad , Obstrucción de las Vías Aéreas/etiología , Salas de Parto , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Masculino , Respiración con Presión Positiva/efectos adversos , Síndrome de Dificultad Respiratoria del Recién Nacido/mortalidadRESUMEN
BACKGROUND: In neonatal resuscitation, a ventilation device providing positive end-expiratory pressure (PEEP) is recommended. There is limited information about PEEP delivery in vivo, using different models of self-inflating bag (SIB) at different inflation rates and PEEP settings. METHODS: We compared PEEP delivery to intubated preterm lambs using four commonly available models of paired SIBs and PEEP valves, with a T-piece, with gas flow of 8 L/min. Peak inspiratory pressure inflations of 30 cmH2O, combined with set PEEP of 5, 7 and 10 cmH2O, were delivered at rates of 20, 40 and 60/min. These combinations were repeated without gas flow. We measured mean PEEP, maximum and minimum PEEP, and its difference (PEEP reduction). RESULTS: A total of 3288 inflations were analysed. The mean PEEP delivered by all SIBs was lower than set PEEP (P<0.001), although some differences were <0.5 cmH2O. In 55% of combinations, the presence of gas flow resulted in increased PEEP delivery (range difference 0.3-2 cmH2O). The mean PEEP was closer to set PEEP with faster inflation rates and higher set PEEPs. The mean (SD) PEEP reduction was 3.9 (1.6), 8.2 (1.8), 2 (0.6) and 1.1 (0.6) cmH2O with the four SIBs, whereas it was 0.5 (0.2) cmH2O with the T-piece. CONCLUSIONS: PEEP delivery with SIBs depends on the set PEEP, inflation rate, device model and gas flow. At recommended inflation rates of 60/min, some devices can deliver PEEP close to the set level, although the reduction in PEEP makes some SIBs potentially less effective for lung recruitment than a T-piece.
Asunto(s)
Respiración con Presión Positiva/métodos , Respiración , Resucitación/métodos , Animales , Animales Recién Nacidos , Diseño de Equipo , Insuflación , OvinosRESUMEN
INTRODUCTION: Umbilical venous catheter (UVC) placement is a common neonatal procedure. It is important to position the UVC tip accurately at the first attempt to prevent complications and minimise handling. Catheters positioned too low need to be removed, but catheters positioned too high may be withdrawn in a sterile fashion to a safe position. We aimed to determine the precision and accuracy of five published formulae developed to guide UVC placement. METHODS: This was a prospective observational study. Following UVC insertion, anteroposterior and lateral X-rays were performed to identify catheter tip position. Parameters required to apply the five formulae were recorded. Insertion lengths were then calculated and compared with the gold standard (UVC tip at the level of the diaphragm on the lateral X-ray). They were also used to classify predicted UVC tip position as either correct (UVC tip at or up to 1 cm above the diaphragm), too high or too low. RESULTS: Of 118 eligible infants, 70 had the UVC tip in a position where measurements could be used. Their median (IQR) gestational age and weight were 28.5 (26-36) weeks and 1035 (745-2788) g, respectively. The predicted success rate for each formula ranged from 44.9% to 55.7%. A formula based on birth weight had the highest rate of either correct or high position (95.8%). CONCLUSIONS: Inserting a UVC into a safe position on first attempt is difficult and low tip placement is common. Around half of UVCs need to be manipulated to achieve the desired position.
Asunto(s)
Cateterismo Periférico/métodos , Cuidado del Lactante/métodos , Venas Umbilicales , Peso al Nacer , Catéteres de Permanencia , Femenino , Edad Gestacional , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , RadiografíaRESUMEN
AIM: Facial measurements of preterm infants indicate that standard diameter facemasks used during positive pressure ventilation are too large, which may lead to mask leak and compromise resuscitation. We aimed to determine whether the use of a facemask that better complies with the dimensions of preterm faces, compared with a standard facemask, reduces facemask leak. METHODS: Parallel group, randomised controlled trial. Preterm infants ≤32 weeks' gestation receiving facemask ventilation prior to intubation in the neonatal intensive care unit, and those 28-32+6 weeks' receiving facemask ventilation in the delivery room were eligible. Infants were randomised to receive ventilation via a standard (50mm) (control), or a smaller (35mm or 42mm) diameter facemask (intervention), stratified by gestation (≤26 weeks'; 35mm, 27-32+6; 42mm). The primary outcome was leak between the mask and the infants face. RESULTS: Of 298 eligible infants, 139 were randomised and 131 were included in the final analysis; 66 in the intervention group and 65 in the control group. The median (IQR) leak was 42% (13-69%) in the intervention group compared with 39% (22-66%) in the control group P=0.43. The median (IQR) lowest oxygen saturation was similar in both groups [intervention 70% (34-93%) vs. control 71% (40-93%) P=0.75]. One infant crossed over from the intervention to the control group due to poor response to ventilation with the intervention facemask. CONCLUSIONS: Smaller facemasks did not reduce mask leak in preterm facemask ventilation. All facemasks had high leak, particularly in infants ≤26 weeks' gestation. CLINICAL TRIAL REGISTRATION: This trial is registered with the Australian New Zealand Clinical Trials Registry, ACTRN12614000709640, www.anzctr.org.au.
Asunto(s)
Máscaras , Respiración con Presión Positiva/métodos , Cara/anatomía & histología , Femenino , Edad Gestacional , Humanos , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recién Nacido de muy Bajo Peso , Masculino , Respiración con Presión Positiva/normas , Método Simple CiegoRESUMEN
OBJECTIVE: To determine whether the use of a hydrocolloid nasal barrier dressing during binasal continuous positive airway pressure (CPAP) therapy, compared with no barrier dressing, reduces the rate of nasal injury in very preterm and/or very low birth weight infants. STUDY DESIGN: A single-center randomized controlled trial conducted in the neonatal intensive care unit at The Royal Women's Hospital, Melbourne. Eligible infants were born <30 weeks of gestation and/or with birth weight <1250 g, and had received ≥4 hours, but <48 hours, of CPAP. Infants were randomly allocated to receive either a hydrocolloid nasal barrier dressing during CPAP (barrier group), or no barrier dressing (no barrier group). The primary outcome was the incidence of any nasal injury during CPAP support, until the infant was both >30 weeks of postmenstrual age and >1250 g, unless CPAP therapy was stopped earlier. Nasal injury was regularly assessed by bedside nurses using a standardized form. RESULTS: A total of 108 preterm infants were enrolled: 53 infants in the barrier group and 55 infants in the no barrier group. Infants in the barrier group had a significantly lower rate of nasal injury compared with the no barrier group: 18 of 53 (34%) vs 31 of 55 (56%), respectively (P = .02), number needed to treat; 5 infants. No significant differences were detected in any secondary respiratory outcomes, or in the rate of common neonatal morbidities. CONCLUSIONS: Prophylactic use of a nasal barrier dressing within 48 hours of commencing treatment with binasal CPAP in very preterm or very low birth weight infants reduces nasal injury. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Register ACTRN12616000438459.
Asunto(s)
Vendas Hidrocoloidales , Presión de las Vías Aéreas Positiva Contínua/efectos adversos , Ventilación con Presión Positiva Intermitente/efectos adversos , Nariz/lesiones , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Australia , Presión de las Vías Aéreas Positiva Contínua/instrumentación , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Puntaje de Gravedad del Traumatismo , Unidades de Cuidado Intensivo Neonatal , Ventilación con Presión Positiva Intermitente/instrumentación , MasculinoRESUMEN
INTRODUCTION: Over five percent of infants born worldwide will need help breathing after birth. Delayed cord clamping (DCC) has become the standard of care for vigorous infants. DCC in non-vigorous infants is uncommon because of logistical difficulties in providing effective resuscitation during DCC. In Baby-Directed Umbilical Cord Clamping (Baby-DUCC), the umbilical cord remains patent until the infant's lungs are exchanging gases. We conducted a feasibility study of the Baby-DUCC technique. METHODS: We obtained antenatal consent from pregnant women to enroll infants born at ≥32 weeks. Vigorous infants received ≥2â¯min of DCC. If the infant received respiratory support, the umbilical cord was clamped ≥60â¯s after the colorimetric carbon dioxide detector turned yellow. Maternal uterotonic medication was administered after umbilical cord clamping. A paediatrician and researcher entered the sterile field to provide respiratory support during a cesarean birth. Maternal and infant outcomes in the delivery room and prior to hospital discharge were analysed. RESULTS: Forty-four infants were enrolled, 23 delivered via cesarean section (8 unplanned) and 15 delivered vaginally (6 via instrumentation). Twelve infants were non-vigorous. ECG was the preferred method for recording HR. Two infants had a HRâ¯<â¯100 BPM. All HR values were >100 BPM by 80â¯s after birth. Median time to umbilical cord clamping was 150 and 138â¯s in vigorous and non-vigorous infants, respectively. Median maternal blood loss was 300â¯ml. CONCLUSIONS: It is feasible to provide resuscitation to term and near-term infants during DCC, after both vaginal and cesarean births, clamping the umbilical cord only when the infant is physiologically ready.
Asunto(s)
Parto Obstétrico/métodos , Resucitación/métodos , Cordón Umbilical/irrigación sanguínea , Estudios de Cohortes , Constricción , Estudios de Factibilidad , Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Intercambio Gaseoso Pulmonar/fisiología , Factores de TiempoRESUMEN
INTRODUCTION: Over 5% of infants worldwide receive breathing support immediately after birth. Our goal was to define references ranges for exhaled carbon dioxide (ECO2), exhaled tidal volume (VTe), and respiratory rate (RR) immediately after birth in spontaneously breathing, healthy infants born at 36 weeks' gestational age or older. METHODS: This was a single-centre, observational study at the Royal Women's Hospital in Melbourne, Australia, a busy perinatal referral centre. Immediately after the infant's head was delivered, we used a face mask to measure ECO2, VTe, and RR through the first ten minutes after birth. Respiratory measurements were repeated at one hour. RESULTS: We analysed 14,731 breaths in 101 spontaneously breathing infants, 51 born via planned caesarean section and 50 born vaginally with a median (IQR) gestational age of 391/7 weeks (383/7-395/7). It took a median of 7 (4-10) breaths until ECO2 was detected. ECO2 quickly increased to peak value of 48â¯mmHg (43-53) at 143â¯s (76-258) after birth, and decreased to post-transitional values, 31â¯mmHg (28-24), by 7â¯min. VTe increased after birth, reaching a plateau of 5.3â¯ml/kg (2.5-8.4) by 130â¯s for the remainder of the study period. Maximum VTe was 19â¯ml/kg (16-22) at 257â¯s (82-360). RR values increased slightly over time, being higher from minute five to ten as compared to the first two minutes after birth. CONCLUSIONS: This study provides reference ranges of exhaled carbon dioxide, exhaled tidal volumes, and respiratory rate for the first ten minutes after birth in term infants who transition without resuscitation.
Asunto(s)
Dióxido de Carbono/análisis , Cesárea/métodos , Parto Normal/métodos , Respiración , Nacimiento a Término/fisiología , Volumen de Ventilación Pulmonar/fisiología , Australia , Pruebas Respiratorias/métodos , Espiración/fisiología , Femenino , Edad Gestacional , Humanos , Recién Nacido , Masculino , Embarazo , Valores de Referencia , Frecuencia RespiratoriaRESUMEN
OBJECTIVE: To compare the suction mask, a new facemask that uses suction to create a seal between the mask and the infant's face, with a conventional soft, round silicone mask during positive pressure ventilation (PPV) in the delivery room in newborn infants >34 weeks of gestation. STUDY DESIGN: Single-center randomized controlled trial in the delivery room. The primary outcome was mask leak. RESULTS: Forty-five infants were studied at a median gestational age of 38.1 weeks (IQR, 36.4-39.0 weeks); 22 were randomized to the suction mask and 23 to the conventional mask. The suction mask did not reduce mask leak (49.9%; IQR, 11.0%-92.7%) compared with the conventional mask (30.5%; IQR, 10.6%-48.8%; P = .51). The suction mask delivered lower peak inspiratory pressure (27.2 cm H2O [IQR, 25.0-28.7 cm H2O] vs 30.4 cm H2O [IQR, 29.4-32.5 cm H2O]; P < .05) and lower positive end expiratory pressure (3.7 cm H2O [IQR, 3.1-4.5 cm H2O] vs 5.1 cm H2O [IQR, 4.2-5.7 cm H2O ]; P < .05). There was no difference in the duration of PPV or rates of intubation or admission to the neonatal intensive care unit. In 5 infants (23%), the clinician switched from the suction to the conventional mask, 2 owing to intermittently low peak inspiratory pressure, 2 owing to failure to respond to PPV, and 1 owing to marked facial bruising after 6 minutes of PPV. CONCLUSIONS: The use of the suction mask to provide PPV in newborn infants did not reduce facemask leak. Adverse effects such as the inability to achieve the set pressures and transient skin discoloration are concerning. TRIAL REGISTRATION: Australian and New Zealand Clinical Trial Registry ACTRN12616000768493.
Asunto(s)
Máscaras , Respiración con Presión Positiva/instrumentación , Succión , Salas de Parto , Diseño de Equipo , Falla de Equipo , Femenino , Edad Gestacional , Humanos , Recién Nacido , MasculinoRESUMEN
OBJECTIVE: Skin-to-skin care (SSC) has proven benefits in preterm infants, but increased hypoxic and bradycardic events have been reported. This may make clinicians hesitant to recommend SSC as standard care. We hypothesised that regional cerebral oxygenation (rStO2) measured with near infrared spectroscopy is not worse during SSC compared with standard incubator care. DESIGN: Prospective, observational, non-inferiority study. SETTING: Single tertiary perinatal centre in Australia. PATIENTS: Forty preterm infants (median (IQR) 30.6 (29.1-31.7) weeks' gestation) not receiving respiratory support were studied on day 14 (8-38). INTERVENTIONS: Recordings during 90 min of incubator care, followed by 90 min of SSC. Each infant acted as their own control and caregivers were blinded to the rStO2 measurements. MAIN OUTCOME MEASURES: The primary outcome was the mean difference in rStO2 between SSC and incubator care. The prespecified margin of non-inferiority was -1.5%. Secondary outcomes included heart rate (HR), peripheral oxygen saturation (SpO2), time in quiet sleep, temperature and hypoxic (SpO2 <80% for >5 s) or bradycardic events (HR <80 bpm for >5 s) and time spent in cerebral hypoxia (rStO2<55%) and hyperoxia (rStO2>85%). RESULTS: Mean (SD) rStO2 was lower during SSC compared with incubator care: 73.6 (6.0)% vs 74.8 (4.6)%, mean difference (95% CI) 1.3 (2.2 to 0.4)%. HR was 5 bpm higher, SpO2 1% lower and time in quiet sleep 24% longer during SSC. Little evidence of a difference was observed in temperature. The number of hypoxic or bradycardic events as well as the proportion of time spent in cerebral hypoxia and hyperoxia was very low in both periods. CONCLUSIONS: Mean rStO2 was marginally lower during SSC without observed differences in hypoxic or bardycardic events but an increase in time spent in quiet sleep. TRIAL REGISTRATION NUMBER: This trial is linked to Australian New Zealand Clinical Trials Registry: identifier 12616000240448. It was registered pre-results.
Asunto(s)
Circulación Cerebrovascular/fisiología , Recien Nacido Prematuro , Método Madre-Canguro/métodos , Oxígeno/sangre , Australia , Femenino , Humanos , Recien Nacido Extremadamente Prematuro , Recién Nacido , Masculino , Oximetría , Estudios Prospectivos , Espectroscopía Infrarroja CortaRESUMEN
OBJECTIVE: Binasal prongs are the most commonly used interface for the delivery of nasal positive airway pressure (CPAP) to preterm infants. However, they are associated with pressure-related nasal injury, which causes pain and discomfort. Nasal injury may necessitate a change in interface and occasionally damage is severe enough to require surgical repair. We aim to determine the incidence and risk factors for nasal injury in preterm infants, and to provide clinicians with strategies to effectively prevent and treat it. DESIGN: We conducted a systematic search of databases including MEDLINE (PubMed including the Cochrane Library), EMBASE, CINAHL and Scopus. Included studies enrolled human preterm infants and were published prior to 20 February 2017. RESULTS: Forty-five studies were identified, including 14 ra ndomised controlled trials, 10 observational studies, two cohort studies, eight case reports and 11 reviews. The incidence of nasal injury in preterm infants ranged from 20-100%. Infants born <30 weeks' gestation are at highest risk. Strategies shown to reduce nasal injury included: nasal barrier dressings (2 studies, n=244, risk ratio (RD) -0.12, 95%, CI - 0.20 to -0.04), nasal high flow therapy as an alternative to binasal prong CPAP (7 studies, n=1570, risk difference (RD) -0.14, 95% CI -0.17 to -0.10), and nasal masks rather than binasal prongs (5 studies, n=544, RR 0.80, 95% CI 0.64 to 1.00). CONCLUSIONS AND RELEVANCE: Nasal injury is common in preterm infants born <30 weeks' gestational age receiving CPAP via binasal prongs. Larger randomised trials are required to fully evaluate strategies to reduce nasal injury.
Asunto(s)
Traumatismos del Nacimiento , Deformidades Adquiridas Nasales , Respiración con Presión Positiva/efectos adversos , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Traumatismos del Nacimiento/etiología , Traumatismos del Nacimiento/prevención & control , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Deformidades Adquiridas Nasales/etiología , Deformidades Adquiridas Nasales/prevención & control , Respiración con Presión Positiva/métodosRESUMEN
Oxygen saturation, measured by pulse oximetry (SpO2), is a vital clinical measure. Our descriptive, cross-sectional study describes SpO2 measurements from 6289 healthy subjects from age 1 to 80 years at 15 locations from sea level up to the highest permanent human habitation. Oxygen saturation measurements are illustrated as percentiles. As altitude increased, SpO2 decreased, especially at altitudes above 2500 m. The increase in altitude had a significant impact on SpO2 measurements for all age groups. Our data provide a reference range for expected SpO2 measurements in people from 1 to 80 years from sea level to the highest city in the world.
Asunto(s)
Altitud , Oxígeno/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Oximetría , Perú , Valores de ReferenciaRESUMEN
OBJECTIVE: To determine whether the use of heated-humidified gases for respiratory support during the stabilization of infants <30 weeks of gestational age (GA) in the delivery room reduces rates of hypothermia on admission to the neonatal intensive care unit (NICU). STUDY DESIGN: A multicenter, unblinded, randomized trial was conducted in Melbourne, Australia, between February 2013 and June 2015. Infants <30 weeks of GA were randomly assigned to receive either heated-humidified gases or unconditioned gases during stabilization in the delivery room and during transport to NICU. Infants born to mothers with pyrexia >38°C were excluded. Primary outcome was rate of hypothermia on NICU admission (rectal temperature <36.5°C). RESULTS: A total of 273 infants were enrolled. Fewer infants in the heated-humidified group were hypothermic on admission to NICU (36/132 [27%]) compared with controls (61/141 [43%], P < .01). There was no difference in rates of hyperthermia (>37.5°C); 20% (27/132) in the heated-humidified group compared with 16% (22/141) in the controls (P = .30). There were no differences in mortality or respiratory outcomes. CONCLUSIONS: The use of heated-humidified gases in the delivery room significantly reduces hypothermia on admission to NICU in preterm infants, without increased risk of hyperthermia. CLINICAL TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Register (www.anzctr.org.au) ACTRN12613000093785.
Asunto(s)
Gases/administración & dosificación , Hipotermia/prevención & control , Terapia Respiratoria/métodos , Australia , Salas de Parto , Femenino , Fiebre/epidemiología , Gases/efectos adversos , Humanos , Humidificadores , Hipotermia/epidemiología , Recién Nacido , Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Masculino , Terapia Respiratoria/efectos adversosRESUMEN
This review examines devices used during newborn stabilisation. Evidence for their use to optimise the thermal, respiratory and cardiovascular management in the delivery room is presented. Mechanisms of action and rationale of use are described, current developments are presented and areas of future research are highlighted.