Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
PLoS Negl Trop Dis ; 13(10): e0007762, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31584959

RESUMEN

BACKGROUND: The Global Programme to Eliminate Lymphatic Filariasis (LF) emphasizes hygiene, exercise, and other measures to reduce morbidity and disability related to LF. We recently reported that a portable, three-dimensional, infrared imaging system (3DIS) provides accurate limb volume measurements in patients with filarial lymphedema. To assess the practical utility of repeated 3DIS measurements for longitudinal lymphedema management, we examined intraday and day-to-day leg volume changes in adults with filarial lymphedema in southern Sri Lanka. METHODOLOGY AND PRINCIPAL FINDINGS: We assessed 41 participants with lower extremity lymphedema (stages 1-6) in their homes in the mornings (6:00-9:00 AM) and afternoons (2:00-6:00 PM) of three days within one calendar week. Two examiners performed replicate 3DIS volume measurements at each visit. Median coefficient of variation among replicate volume measurements was 1.7% (IQR 1.1% - 2.3%) for left legs and 2.2% (IQR 1.6% - 2.8%) for right legs. Median intraday volume increase was 3.0%. Range among daily volume measurements tended to be lower for afternoon measurements (median 2.25%, IQR 1.4%- 5.4%) than for morning measurements (median 3.0%, IQR 1.4% - 8.4%). CONCLUSIONS AND SIGNIFICANCE: Limb volume measurements by 3DIS are accurate and reproducible, and this technique is feasible for use in patients' homes. We have developed practical suggestions for optimal outcomes with 3DIS. Duplicate measurements should be performed and repeat assessments should be done at approximately the same time of day to minimize bias. Duplicate measures that vary by more than 8% should prompt review of scanning technique with a repeat measurement. With proper training and attention to technique, 3DIS can be a valuable tool for healthcare workers who work with lymphedema patients.


Asunto(s)
Filariasis Linfática/diagnóstico por imagen , Extremidades/diagnóstico por imagen , Imagenología Tridimensional/métodos , Rayos Infrarrojos , Adulto , Anciano , Extremidades/patología , Femenino , Personal de Salud/educación , Humanos , Pierna/diagnóstico por imagen , Linfedema/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Sri Lanka
2.
Am J Trop Med Hyg ; 97(6): 1836-1842, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29141750

RESUMEN

The World Health Organization's Global Program to Eliminate Lymphatic Filariasis (LF) has reduced LF transmission worldwide, but millions remain affected by filarial lymphedema. Tools for clinically monitoring lymphedema in developing nations are limited. We tested a novel, portable, infrared three-dimensional imaging system (3DIS) against water displacement (WD) and tape measurement of limb circumference (TMLC) among patients with filarial leg lymphedema in Galle, Sri Lanka. Outcomes were accuracy and reproducibility of imaging system measurements. In parallel, we also tested the reproducibility of skin thickness ultrasound (STU) measurements. We examined 52 patients (104 limbs) with lymphedema of stages 0-6 (N = 28, 19, 20, 21, 2, 4, and 10, respectively). 3DIS measurements correlated nearly perfectly with WD (r2 = 0.9945) and TMLC values (r2 > 0.9801). The median time required to acquire imaging system measurements for both legs was 2.1 minutes, compared with 17, 7, and 29 minutes, respectively, for WD, TMLC, and STU. Median interexaminer coefficients of variation (CVs) for volume measurements were 1.1% (interquartile range [IQR] 0.5-2.1%) for WD and 1.7% (IQR 1.2-2.4%) for the 3DIS. CVs for circumference measurements were 1.4% (IQR 0.8-2.4%) by TMLC and 1.3% (0.8-1.9%) by 3DIS. Median interexaminer CV for STU was 13.7% (IQR 8.5-21.3%). The portable imaging system noninvasively provided accurate and reproducible limb volume and circumference measurements in approximately 2 minutes per patient. This portable technology has the potential to greatly improve assessment and monitoring of lymphedema in the clinic and in the field.


Asunto(s)
Filariasis Linfática/diagnóstico por imagen , Extremidades/diagnóstico por imagen , Imagenología Tridimensional/instrumentación , Humanos , Modelos Lineales , Reproducibilidad de los Resultados , Sri Lanka
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...