RESUMEN
BACKGROUND: The aim of this study was to develop and validate a short and feasible questionnaire to measure health-related quality of life (HRQoL) in patients with peripheral artery disease (PAD). The content of the new instrument is intended to correspond with the simultaneously developed instrument Patient Benefit Index for PAD (PBI-PAD), which evaluates treatment goals and benefits in this patient group. METHODS: Fifty patients stated their disease burden on free-text questionnaires, which was used by an interdisciplinary expert panel to develop 12 items for the new instrument, named Quality of Life questionnaire for patients with peripheral artery disease (QOLPAD). The validity of the instrument was tested in patients from Germany with PAD stages I to IV who completed the QOLPAD, EuroQol questionnaire (EQ-5D-3L; EuroQol visual analogue scale (EQ VAS)), and Vascular Quality of Life questionnaire (VascuQoL) before (baseline) and three months after (follow-up) treatment. RESULTS: One hundred and three patients were included at baseline (mean age: 68.6 years; 68% male), among whom, 57 provided data at follow-up. Most patients (86.4%) rated the completion of QOLPAD as being easy. Internal consistency was satisfactory, with a Cronbach's alpha of 0.74 (baseline) and 0.84 (follow-up). Convergent validity was indicated by significant correlations with the EQ-5D-3L (baseline: - 0.62; follow-up: - 0.81), EQ VAS (baseline: - 0.44, follow-up: - 0.79), VascuQoL global score (baseline: - 0.77; follow-up: - 0.87), global rating of impairment (baseline: 0.64; follow-up: 0.71), and PAD stage (baseline: 0.40; follow-up: 0.67). Sensitivity to change was confirmed by significant correlations of change in the QOLPAD with changes in convergent criteria; however, the high number of dropouts limits the generalizability of this finding. CONCLUSION: This study provided evidence that the QOLPAD is internally consistent and valid in patients receiving treatment for PAD in Germany.
RESUMEN
BACKGROUND: The aim of this study was to analyse the influence of true, false, and combined lumen perfusion of renal arteries on mid- and long-term kidney volume in patients with type B aortic dissection (TBAD). METHODS: Retrospective analysis of patients diagnosed with a TBAD between 2008 and 2015 in a single high-volume European center. The origin of the renal arteries was evaluated on a dedicated 3D workstation (TeraRecon Inc., San Mateo, CA, USA) and coded as either arising from the true lumen (TL), false lumen (FL) or from a combination of both (CL). Additional evaluated anatomical parameters were renal volume, length, width, and depth of the kidneys. Measurements were recorded at the time of diagnosis (T0) and at 1-month (T1), 6-months (T2), 18-months (T3) and 36-month of follow-up time (T4). RESULTS: A total of 131 renal arteries and kidneys were evaluated in 69 patients. Mean age was 64±13 years and 77% were male. The absolute number and percentage of assessed renal arteries/kidneys was 131 (100%) at T0, 89 (68%) at T1, 73 (56%) at T2, 57 (44%) at T3 and 43 (44%) at T4. At the time of diagnosis, 71.6% renal arteries originated from the TL, 19.1% from the FL and 9.2% from a CL. TEVAR was performed in 92.7% patients and nine patients had additional renal artery stenting. At T0 the mean renal volume was 212.1±70.9cm3, 178±61.2 in women versus 222.2±70.6 in men (P=0.002). Forty-three percent of the patients had a renal volume reduction ≥15% from T0 to their last available CTA. Mixed model analysis showed a significant overall renal volume reduction of 13.7cm3 from T0 to T4 (P<0.05). No significant differences in renal-volume reduction were observed depending on origin of the renal artery, though an estimated reduction of renal volume from T0 to T4 of 40.8 cm3 was seen when the kidneys were perfused by a CL, while TL perfusion only caused a reduction of 15.6 cm3 and no relevant volume change over time was observed when the renal artery originated from FL. Alongside a renal volume reduction, mixed model analysis also showed a significant serum-creatinine increase, from 0.8618mg/at T0 to 1.38±0.56 mg/dL at T4 (P<0.001), as well as a significant glomerular filtration rate reduction over time, from > 60mL/min at T0 to 49±13 mL/min at T4 (P<0.001). A negative correlation was observed between creatinine values and renal volume change, while a positive correlation was observed between GFR and renal volume change (P<0.001). CONCLUSIONS: There is a significant mid-term renal-volume reduction in patients with TBAD, independent of the origin of the renal arteries. Albeit not statistically significant, combined renal artery perfusion may lead to a greater volume reduction, potentially secondary to a relevant dynamic compression by the dissection membrane. Further multicentre studies are warranted to determine the effect on long-term renal function and on possible preventive strategies.
Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Creatinina , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Riñón/fisiología , Masculino , Persona de Mediana Edad , Perfusión , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVES: To study the outcome of endovascular treatment of aortic pathologies in patients with Marfan syndrome (MFS) at a single institution. METHODS: Consecutive MFS patients who underwent endovascular repair or hybrid procedures for aortic pathologies from January 2010 to May 2020 were identified. Several endovascular and hybrid strategies have been used. Technical success, short- and mid-term survival, complications, and re-interventions were retrospectively analyzed. RESULTS: During the study period, 24 patients with MFS (median age, 48 [13-78] years; 58% males) were treated. Indications for intervention were chronic aortic dissection with aneurysm degeneration in 16 patients (67%), acute type B aortic dissection in 4 patients (17%), aortic aneurysm without any dissection in 3 patients (13%), and aortic intramural hematoma in 1 patient (4%). Most patients were asymptomatic (83%), three (13%) were symptomatic and one (4%) had a contained rupture. The median aneurysm diameter was 56 (35-86) mm. Hybrid procedures were performed in 7 (29%) patients. Thoracic endovascular repair was performed in 12 (50%) patients, a fenestrated or branched endovascular aortic repair in 4 (17%) patients, and placement of an iliac artery stent-graft in 1 (4%) patient. Procedures were staged in 12 (50%) patients. Technical success was achieved in all patients. The median intensive care unit stay was 6 (range, 1-30) days, and the median hospital stay was 23 (range, 3-112) days. Early mortality was reported in 1 (4%) patient. Wound infection was seen in 7 (29%) patients and gastrointestinal complications in 3 (13%) patients. The median follow-up was 42 (range, 1-127) months. The cumulative survival rate was 87% at 24 months. The cumulative freedom from re-intervention was 77% at 12 months. CONCLUSIONS: Endovascular treatment of aortic pathologies in patients with MFS appears feasible with acceptable early and mid-term outcomes in terms of mortality and re-intervention rates. Endovascular therapy plays an increasing role in MFS patients with aortic pathology.
Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Síndrome de Marfan , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
AIMS: In this secondary analysis of the VOYAGER trial, rivaroxaban 2.5 mg twice/day plus aspirin 100 mg/day was assessed in older adults. Advanced age is associated with elevated bleeding risk and unfavourable net benefit for dual antiplatelet therapy in chronic coronary artery disease. The risk-benefit of low-dose rivaroxaban in patients ≥75 years with peripheral artery disease (PAD) after lower extremity revascularization (LER) has not been described. METHODS AND RESULTS: The primary endpoint was a composite of acute limb ischaemia, major amputation, myocardial infarction, ischaemic stroke, or cardiovascular death. The principal safety outcome was thrombolysis in myocardial infarction (TIMI) major bleeding analysed by the pre-specified age cut-off of 75 years. Of 6564 patients randomized, 1330 (20%) were >75 years. Absolute 3-year Kaplan-Meier cumulative incidence rates for primary efficacy (23.4% vs. 19.0%) and safety (3.5% vs. 1.5%) endpoints were higher in elderly vs. non-elderly patients. Efficacy of rivaroxaban (P-interaction 0.83) and safety (P-interaction 0.38) was consistent irrespective of age. The combination of intracranial and fatal bleeding was not increased in patients >75 years (2 rivaroxaban vs. 8 placebo). Overall, benefits (absolute risk reduction 3.8%, number needed to treat 26 for the primary endpoint) exceeded risks (absolute risk increase 0.81%, number needed to harm 123 for TIMI major bleeding). CONCLUSION: Patients ≥75 years with PAD are at both heightened ischaemic and bleeding risk after LER. No excess harm with respect to major, intracranial or fatal bleeding was seen in older patients yet numerically greater absolute benefits were observed. This suggests that low-dose rivaroxaban combined with aspirin should be considered in PAD after LER regardless of age.
Asunto(s)
Isquemia Encefálica , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Anciano , Aspirina/efectos adversos , Quimioterapia Combinada , Inhibidores del Factor Xa/efectos adversos , Humanos , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/tratamiento farmacológico , Enfermedad Arterial Periférica/cirugía , Inhibidores de Agregación Plaquetaria/efectos adversos , Rivaroxabán/efectos adversos , Accidente Cerebrovascular/tratamiento farmacológicoRESUMEN
OBJECTIVES: Peripheral arterial occlusive disease (PAOD) and periodontitis are common chronic diseases, which together affect almost 1 billion people worldwide. There is growing evidence suggesting a relationship between chronic inflammatory conditions such as periodontitis and PAOD. This study aims to determine an association between both entities using high quality research data and multiple phenotypes derived from an epidemiological cohort study. DESIGN: This population-based cross-sectional cohort study included data from 3271 participants aged between 45 and 74 years enrolled in the Hamburg City Health Study (NCT03934957). MATERIAL & METHODS: An ankle-brachial-index below 0.9, color-coded ultrasound of the lower extremity arteries, and survey data was used to identify participants with either asymptomatic or symptomatic PAOD. Periodontitis data was collected at six sites per tooth and included the probing depth, gingival recession, clinical attachment loss, and bleeding on probing index. Multivariate analyses using logistic regression models were adjusted for variables including age, sex, smoking, education, diabetes, and hypertension. RESULTS: The baseline characteristics differed widely between participants neither affected by periodontitis nor PAOD vs. the group where both PAOD and severe periodontitis were identified. A higher rate of males, higher age, lower education level, smoking, diabetes, and cardiovascular disease was observed in the group affected by both diseases. After adjusting, presence of severe periodontitis (odds ratio 1.265; 97.5% CI 1.006-1.591; p = 0.045) was independently associated with PAOD. CONCLUSION: In this cross-sectional analysis of a prospective cohort study, an independent association between periodontitis and PAOD was revealed. The results of the current study emphasize a potential for preventive medicine in an extremely sensitive target population. Future studies should determine the underlying factors modifying the relationship between both diseases.
RESUMEN
INTRODUCTION: The repair of long-term complications of open abdominal aortic repair such as para-anastomotic aneurysm (PAA) and pseudoaneurysm (PSA) is very challenging. The aim of this study was to assess the outcomes of endovascular repair of PAA/PSA after previous open aortic surgery for aneurismal or occlusive disease. EVIDENCE ACQUISITION: A systematic review was undertaken; a search was performed (PRISMA) in MEDLINE, CENTRAL, Cochrane databases and key references of all studies of endovascular treatment of PAA/PSA after open aortic surgery. EVIDENCE SYNTHESIS: Eighteen studies included totally 433 patients (86.3% males) with mean age of 71±2.5 years were identified. Most of the patients were asymptomatic (76%) and diagnosed with PAA (60.5%), while 81.6% had history of open aortic reconstruction for aneurismal disease. The mean diameter of para-anastomotic aneurysms was 59.7 mm (from 23 mm to 110 mm) and the mean duration until their diagnosis was 10±2 years. Standard bifurcated (23.7%), fenestrated (23.4%) and aorto-uni-iliac stent-grafts (16.3%) were mostly used. The technical success rate was 97.8% (391/400) with 1.4% (6/433) 30 day-mortality rate and mean hospital stay of 6±3 days. The mean 1- and 2- year survival rate was 87.8% and 78.8%, respectively. The follow-up ranged from 9 to 43 months, with presenting complications such as endoleak type I (24/378; 6.3%), type II (15/354; 4.3%), type III (3/378;0.8%), migration (4/378; 1%) and limb occlusion (5/310;1.6%). Additionally, 5.7% (19/332) of the patients underwent open conversion, while the total re-intervention rate was 11.4% (39/340; time of reintervention ranged from 7 to 30 months). In cases in which a stent was used for splanchnic vessels (renal artery: 188, superior mesenteric artery: 98, celiac artery: 64), the primary patency rate was 97.4% (341/350). CONCLUSIONS: Endovascular treatment of PAAs and PSAs after previous open aortic surgery is a feasible and efficient option with high technical success rate, low 30-day mortality and good mid-term outcomes.
Asunto(s)
Aneurisma Falso/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/cirugía , Procedimientos Endovasculares/métodos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Aneurisma Falso/etiología , Aneurisma Falso/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aortografía/métodos , Implantación de Prótesis Vascular/métodos , Causas de Muerte , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Laparotomía/métodos , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Pronóstico , Reoperación/métodos , Reoperación/mortalidad , Medición de Riesgo , Análisis de Supervivencia , Resultado del TratamientoRESUMEN
OBJECTIVE: The aim of our study was to analyze the incidence of spinal cord ischemia (SCI) in patients presenting with complex aortic aneurysms treated with endovascular aneurysm repair (EVAR) and to identify risk factors associated with this complication. METHODS: A retrospective study was undertaken of prospectively collected data including patients presenting with complex aortic aneurysm (pararenal abdominal aortic aneurysm and thoracoabdominal aortic aneurysm) treated with fenestrated EVAR (F-EVAR) or branched EVAR (B-EVAR). The primary end point was the incidence of SCI and the assessment of any associated factors. RESULTS: Between January 2011 and August 2017, a total of 243 patients (mean aneurysm diameter, 65.2 ± 15.3 mm; mean age, 72.4 ± 7.5 years; 73% male) were treated with F-EVAR or B-EVAR. Asymptomatic patients were treated in 73% of the cases (177/243, in contrast to 27% urgent), and 52% (126/243) were treated for thoracoabdominal aortic aneurysm (in contrast to 48% for pararenal abdominal aortic aneurysm). F-EVAR (mean number of fenestrations, 3.3/case) and B-EVAR (mean number of branches, 3.7/case) were undertaken in 67% (164/243) and 33% (79/243), respectively. The total incidence of SCI was 17.7% [43/243; paraplegia in 4% (10/243) and paraparesis in 13.7% (33/243)]. Most of the patients with SCI presented with immediate postoperative symptoms (72% [31/43]). A spinal drain was preoperatively placed in 53% (130/243) and was associated with the prevention of SCI (SCI with spinal drainage, 12% [16/130]; SCI without spinal drainage, 24% [27/113]; P = .018). The 30-day mortality rate was 9% (21/243). After multiple logistic regression analysis, SCI was associated with preoperative renal function (SCI with preoperative glomerular filtration rate <60 mL/min/1.73 m2: odds ratio [OR], 2.43; 95% confidence interval [CI], 1.18-4.99; P = .016) and the number of vertebral segments covered (SCI with higher position of proximal stent in terms of vertebra: OR, 1.2; 95% CI, 1.1-1.3; P = .000). A similar outcome was derived when the height of the proximal end of the stent graft was replaced by the total length of aortic coverage (SCI with preoperative glomerular filtration rate <60 mL/min/1.73 m2: OR, 2.36 [95% CI, 1.11-5.00; P = .025]; SCI with longer length of aortic coverage: OR, 1.01 [95% CI, 1.003-1.009; P = .000]). CONCLUSIONS: The majority of SCI incidence after F-EVAR or B-EVAR of complex aortic aneurysms is manifested immediately postoperatively. The use of preoperative spinal drainage may prevent SCI. Patients with GRF <60 mL/min/1.73 m2 and with longer aortic stent graft coverage are at higher risk of SCI.
Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Isquemia de la Médula Espinal/epidemiología , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/mortalidad , Femenino , Tasa de Filtración Glomerular , Humanos , Incidencia , Riñón/fisiopatología , Masculino , Flujo Sanguíneo Regional , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Isquemia de la Médula Espinal/diagnóstico por imagen , Isquemia de la Médula Espinal/mortalidad , Isquemia de la Médula Espinal/fisiopatología , Factores de Tiempo , Resultado del TratamientoRESUMEN
Ilioiliac fistulae are a rare condition, for which diagnosis and treatment can be challenging. In this report, we describe the case of a 74-year-old patient with a high-flow fistula between the left common iliac artery and the ipsilateral common iliac vein presenting with heart failure. The fistula was probably iatrogenic, caused by prostatic surgery 1 year earlier. We describe imaging findings on computed tomography angiography and the treatment by 2 back-table reversed stent grafts. The satisfactory results demonstrated in our case and those in the literature suggest that an endovascular treatment for this rare condition should be considered as the first-line therapy.
Asunto(s)
Fístula Arteriovenosa/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Vena Ilíaca/cirugía , Stents , Anciano , Fístula Arteriovenosa/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Humanos , Arteria Ilíaca/diagnóstico por imagen , Vena Ilíaca/diagnóstico por imagen , Masculino , Diseño de Prótesis , Resultado del TratamientoRESUMEN
BACKGROUND: Residual patent false lumen (FL) after chronic type B aortic dissection (cTBAD) or type A aortic dissection (TAAD) treatment is independently associated with poor long-term outcomes. The aim of our study was to present endovascular techniques and the existing experience with targeted FL thrombosis after cTBAD or TAAD treatment. MATERIAL AND METHODS: A systematic review was performed (Preferred Reporting Items for Systematic reviews and Meta-Analyses) searching in MEDLINE, CENTRAL, and Cochrane databases for studies reporting on targeted FL occlusion after cTBAD or TAAD treatment. RESULTS: One hundred one patients either after open repair of a TAAD (n = 40; 3 case reports and 3 retrospective studies) or after cTBAD (n = 61; 13 case reports and 6 retrospective studies) underwent an endovascular procedure for intentional FL occlusion (2 studies reported on both procedures). Among TAAD patients, 27 of 40 (68%) had previous open repair, whereas 48 of 61 (79%) with cTBAD had a previous endovascular repair. Thirty-one (78%) patients with TAAD and fifty-one (83%) with cTBAD were treated electively. Four main techniques were used: (1) the candy-plug (19/101), (2) the knickerbocker (3/91), (3) the "cork in the bottle neck" technique (2/101), and (4) FL embolization with combined use of coils, onyx, plugs, and glue (77/101). The technical success rate was 100%, with a 30-day mortality rate of 2.5% (1/40) in TAAD and 0% in cTBAD patients. During follow-up (ranging: 2 to 63 months), the mortality rate was 0% (0/31) and 7.1% (4/61) in TAAD and cTBAD patients, respectively. The FL remained completely thrombosed in 78% (31/40) of TAAD and 62% (38/61) of cTBAD patients, whereas it was partially thrombosed in 3 and 2 patients, respectively (no report for 22 patients). CONCLUSIONS: Intentional FL occlusion seems to be a feasible less invasive approach after cTBAD or TAAD treatment, which is not broadly used. Future larger studies with longer follow-up duration may demonstrate the apparent benefit in terms of aortic remodeling or stabilization of the disease progression.
Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Embolización Terapéutica , Procedimientos Endovasculares , Trombosis , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/fisiopatología , Aortografía/métodos , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVES: DeBakey Type I aortic dissections are frequently treated by an ascending aortic tube graft or hemiarch replacement with the residual dissection remaining untreated. We investigated the outcomes of branched thoracic endovascular repair for post-dissection aneurysms of the aortic arch. METHODS: We conducted a retrospective, single-centre evaluation of 20 consecutive patients with a false-lumen aneurysm after a DeBakey I aortic dissection treated with branched thoracic endovascular repair. The indication for endovascular repair was agreed on in an interdisciplinary case conference. Study end points were technical success, 30-day mortality rate, complications and late complications and reinterventions. RESULTS: Between 2012 and 2016, 20 patients (14 men, age 65 ± 9 years) were treated for false-lumen aneurysm formation after a DeBakey Type I aortic dissection. All patients had undergone open ascending aortic repair either isolated (n = 16) or with partial arch repair (n = 4). Technical success was achieved in 19 of 20 cases. The 30-day mortality rate and incidence of stroke were each 5% (1/20). Simultaneous procedures to exclude false-lumen perfusion included implantation of a Knickerbocker graft in 3 (15%) patients and a candy-plug graft in 7 (35%) patients. Early postoperative computed tomography angiography revealed persistent false-lumen perfusion in 10 cases that required secondary interventions in 6 cases. During 17 ± 14 months of mean follow-up, there was 1 aortic-related death and 2 deaths of non-aortic reasons. The estimated overall survival was 89 ± 7% and 75 ± 15% at 12 and 36 months, respectively. CONCLUSIONS: Treatment of residual aortic arch dissections with branched thoracic endovascular repair appears feasible and safe with few deaths and low stroke rates. A high rate of secondary procedures is required to achieve thoracic false-lumen occlusion.
Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Prótesis Vascular , Anciano , Disección Aórtica/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/estadística & datos numéricos , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios RetrospectivosRESUMEN
OBJECTIVE: The objective of this study was to assess the early and midterm outcomes of endovascular repair of complex aortic aneurysm cases using the Multilayer Flow Modulator (MFM; Cardiatis, Isnes, Belgium) endograft in Germany. METHODS: A retrospective study including patients presenting with abdominal aortic aneurysm (AAA), thoracic aortic aneurysm, or thoracoabdominal aortic aneurysm treated with the MFM was conducted in Germany. Mortality and morbidity (in terms of spinal cord ischemia, visceral ischemia, and stroke) at 30 days postoperatively were evaluated. In addition, during follow-up, freedom from reintervention, rupture, and failure mode were also assessed. RESULTS: Between 2009 and 2014, a total of 61 patients with AAA, thoracoabdominal aortic aneurysm, or thoracic aortic aneurysm were treated with the MFM endograft in 29 hospitals around Germany. However, data of 40 patients with a mean age of 73.4 ± 11.2 years (72.5% male; 29/40) and mean aortic aneurysm diameter of 60.3 ± 16.6 mm from 14 hospitals were available for this retrospective study. Thirty-seven (93%) patients were treated urgently. In 12 cases (12/40 [30%]), patients were treated outside instructions for use because of aortic aneurysm diameter >65 mm. A total of 69 MFM stents were used (1.7/patient). The technical success rate was 95% (38/40). Postoperatively, no patient presented with spinal cord ischemia, renal function deterioration, stroke, or intestinal ischemia, except for one patient who developed multiorgan failure because of early stent migration. The intraoperative and 30-day mortality rate was 0% and 2.5%, respectively. The mean follow-up was 12.9 months (±14.9 months), with a survival rate at 1 month, 6 months, and 12 months of 97%, 78%, and 70%, respectively. Freedom from failure mode (type I or II) at 1 month, 6 months, and 12 months was 97.5%, 88%, and 86%, respectively, and visceral vessel patency was 99.3% (155/156 available). During follow-up, 4 patients (4/39 [10%]) had an aneurysm sac rupture and 10 (10/39 [25%]) underwent a reintervention. Freedom from rupture and freedom from reintervention at 1 month, 6 months, and 12 months were 97.5% and 100%, 96% and 84%, and 86% and 75%, respectively. CONCLUSIONS: The use of the MFM for endovascular treatment of complex aortic aneurysm in urgent cases appears to be technically feasible in terms of mortality and morbidity, with moderate 30-day and acceptable midterm outcomes. Reinterventions may be needed to expand the utility of outcomes.
Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Supervivencia sin Enfermedad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Estudios de Factibilidad , Femenino , Alemania , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción VascularRESUMEN
OBJECTIVE: The aim of this study was to assess the immediate postoperative and midterm outcome of complex aortic aneurysm treatment necessitating four-vessel revascularization with either a total endovascular approach (fenestrated-branched stent graft [FBSG]) or a hybrid technique of visceral debranching plus stenting. METHODS: The clinical data of consecutively treated patients presenting with a complex aortic aneurysm that necessitated four-vessel revascularization between 2010 and 2015 were retrospectively analyzed. RESULTS: There were 98 patients (65 men [68%]) with a mean age of 70.65 ± 4 years who presented with aortic aneurysm (Crawford type I, 12; type II, 18; type III, 12; type IV, 24; type V, 6; and juxtarenal and suprarenal, 26) and were treated with either FBSG (76/98 [77.5%]) or hybrid repair (22/98 [22.4%]). Twenty-six patients were symptomatic (16, pain; 10, contained rupture). The mean maximum aneurysm diameter was 65 ± 15 mm, and 53% of the patients had a prior aortic intervention. In FBSG-treated patients, 15 off-the-shelf multibranched stent grafts, 3 surgeon-modified fenestrated stent grafts, and 58 custom-made devices tailored to the patient's anatomy were used. Four fenestrations, four branches, and their combination were used in 38 cases, 30 cases, and 8 cases, respectively. A total of 304 target vessels were addressed, with technical success rate of 96% (292/304). In most hybrid cases (18/22 [82%]), a two-stage procedure was undertaken. All target vessels were successfully revascularized with 88 bypasses. The 30-day mortality was 15.3% (15/98), and the early target vessel occlusion was 9.1% (2 in FBSG, 7 in hybrid). After multivariate analysis, type of procedure (hybrid) was independently associated with higher early mortality (odds ratio, 6.3; P = .01). The morbidity was mainly attributed to pulmonary complications (16.3%), lower extremity weakness (16.3%), mesenteric ischemia (6.1%), dialysis on discharge (6.1%), and complete paraplegia (4.3%). Acute renal failure (2.6% vs 18%; P = .03) and mesenteric ischemia (3% vs 23%; P = .001) presented more commonly in the hybrid group. The mean follow-up was 16.4 ± 5 months, and the mortality rate was 19.4% (12% in the FBSG group vs 45% in the hybrid group; P = .05). The graft and stent graft patency rate was 87.8% (three branches and nine bypasses were occluded). CONCLUSIONS: FBSG and hybrid technique seem to be feasible treatment options for complex aortic aneurysms that necessitate four-vessel revascularization. FBSG may be associated with lower mortality and morbidity rates in comparison to the hybrid procedure. FBSG should be the treatment of choice for complex aneurysms in patients with comorbidities, whereas hybrid repair should be considered for acute cases unsuitable for endovascular repair.
Asunto(s)
Aneurisma de la Aorta/cirugía , Prótesis Vascular , Procedimientos Endovasculares/métodos , Stents , Anciano , Aneurisma de la Aorta/diagnóstico , Aneurisma de la Aorta/mortalidad , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del TratamientoRESUMEN
BACKGROUND: The aim of the present study was to examine the frequency of gas within the aneurysm sac following endovascular aneurysm repair (EVAR) on early postoperative computed tomography (CT) scans, to measure its volume, record the location, and analyze anatomical and procedural risk factors of its presence. METHODS: A retrospective analysis of prospectively collected data of patients undergoing standard, fenestrated, or branched EVAR between January 2013 and December 2015 was undertaken. The presence, position, and size of gas in the postoperative computed tomography angiography (CTA) (within 10 days) was examined, classified as (1) gas near aortic wall; (2) between aortic wall and endograft; and (3) near endograft and further analyzed in terms of anatomical and procedural risk factors associated with its presence. RESULTS: From a total of 241 (85% males, 204/241 and 15% females, 37/241) patients who were treated with EVAR, CTA within 10 days was available in 211 patients with mean age of 73 ± 8.3 years. Gas was present on postoperative CT scan in 83 of 211 (39%) patients; 59/83 (71%) standard, 19/83 (23%) fenestrated, and 5/83 (6%) branched EVAR. The location of the gas was more frequently near the aortic wall (a) (46/83; 55.4%), with the mean gas volume to be 0.41 mL (range 0.01-2.74). Endoleak type II was diagnosed in 31.2% (66/211) of the cases and was not associated with the presence of gas (20/83; presence vs. 46/128; absence of gas; P = 0.069). The presence of gas was associated with larger preoperative diameter of the aortic perfused lumen (P = 0.013). The type of graft was correlated to the presence of gas on postoperative CTA (more frequent in standard EVAR [odds ratio 8; 95% confidence interval {CI} 2.01-31.25] and fenestrated [odds ratio 5.81; 95% CI 1.41-23.81]). In standard EVAR patients, the presence of gas was more frequently identified in early CTA (<5 days) than in later one (6-10 days) (P = 0.000). During the first month follow-up, no patient demonstrated any signs of infection in clinical and radiological assessment. CONCLUSIONS: The presence of gas in the aneurysm sac after EVAR is a frequent finding on postoperative CTA and not related to infection or endoleak. Type of stent graft and size of the perfused lumen is associated with the presence of gas.
Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Complicaciones Posoperatorias/diagnóstico por imagen , Diseño de Prótesis , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Femenino , Gases , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION: This study evaluates the current experience on endovascular repair of the aortic arch pathologies, the feasibility and safety of the procedure. EVIDENCE ACQUISITION: A systematic review was performed. MEDLINE, CENTRAL, and Cochrane databases were searched with PRISMA methodology for published studies reporting on endovascular repair of aortic arch pathologies from 2000 to 2018. EVIDENCE SYNTHESIS: Thirteen non-randomized retrospective studies (either single or multicenter), two multicenter Registries and one multicenter non-randomized interventional study were included in the systematic review. The total number of patients who underwent total endovascular repair of the aortic arch pathology with either fenestrated, branched, or a combination of those devices or chimney technique was 952 patients (73%; 634/872 males, mean age ranging from 51 to 78 years). The technical success rate was 96.7% (921/952), while the 30-day mortality rate was 3.3% (32/952). The most common adverse events were endoleak type I (13.5%; 35/259), stroke (5.1%; 49/952), spinal cord ischemia (1.4%; 14/952) and retrograde dissection (1%; 8/952). During the follow-up period (mean ranging: 16.9 to 41.4 months; median ranging: 9 to 44.8 months) the total number of deaths was 31 (4.4%; 31/693). The total loss of supra-aortic vessel patency rate was 1.7% (14/803) and a re-intervention was needed in 50 patients (9%; 50/559; 11 open conversion). CONCLUSIONS: Endovascular repair of aortic arch pathologies is a feasible treatment option with good early and reasonable mid-term outcomes. This treatment modality approaches a level of maturity and may be considered as a solid alternative method of treatment.
Asunto(s)
Aorta Torácica/cirugía , Prótesis Vascular , Procedimientos Endovasculares/tendencias , Stents , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Humanos , Diseño de PrótesisRESUMEN
BACKGROUND: The aim of this study was to evaluate the long term durability of fenestrated endovascular aortic aneurysm repair (F-EVAR) of juxta-renal aortic aneurysms (JAAAs) in terms of mortality, target visceral vessel (TVV) patency and Reintervention rates. EVIDENCE ACQUISITION: A systematic review and meta-analysis was performed. MEDLINE, CENTRAL, and Cochrane databases were searched with PRISMA methodology for studies reporting on F-EVAR of JAAA presenting follow-up >36 months. Articles with <15 patients, follow-up <36 months, comparison of F-EVAR with other treatment modalities were excluded. EVIDENCE SYNTHESIS: Seven non-randomized retrospective studies of prospectively collected data were analysed including 772 patients (mean age and diameter ranging from 71.5 to 74 years and from 60 to 65mm, respectively) underwent F-EVAR for JAAA during 2001-2015. The pooled mortality rates during 12, 24, 36, 48 and 60 months were 0.080 (0.060-0.106), 0.129 (0.097-0.169), 0.211 (0.158-0.277), 0.279 (0.193-0.386) and 0.405 (0.303-0.517), respectively. The pooled Reintervention rates during 12, 24, 36 and 48 months were 0.097 (0.066-0.140), 0.131 (0.082-0.203), 0.281 (0.182-0.406) and 0.244 (0.103-0.477), respectively. The pooled loss of TVV patency rates during 12, 24, 36, 48 and 60 months were 0.046 (0.035-0.060), 0.081 (0.058-0.110), 0.088 (0.060-0.127), 0.123 (0.067-0.214) and 0.132 (0.081-0.207). CONCLUSIONS: F-EVAR for the treatment of patients with JAAA is a durable procedure with good long term outcomes in terms of mortality and visceral vessels patency. During long term period the need for a Reintervention continues to exists, thus follow-up of those cases may be important for preserving the good results.
Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción VascularRESUMEN
OBJECTIVE: Type II endoleak after endovascular aneurysm repair (EVAR) is frequently caused by persistent flow from the inferior mesenteric artery (IMA). The aim of this study was to assess the perioperative and midterm efficacy of laparoscopic ligation of the IMA for treatment of endoleak. METHODS: MEDLINE, Cochrane Central Register of Controlled Trials, and Cochrane databases and key references were searched with Preferred Reporting Items for Systematic Reviews and Meta-Analyses methodology for studies reporting on laparoscopic ligation of the IMA for treatment of type II endoleak after EVAR. RESULTS: Eight case studies and one study of a retrospective nature were identified. In total, 20 patients (18 men; mean age, 73.6 ± 2 years; with a mean abdominal aortic aneurysm diameter of 64.3 ± 10 mm) who underwent post-EVAR laparoscopic ligation of the IMA for type II endoleak were analyzed. The mean time from EVAR until intervention ranged from 6 to 18 months. All but one patient were asymptomatic; in 9, the aneurysm sac was enlarged, and in 11, the endoleak was considered persistent without sac enlargement. The mean procedural duration was 99 ± 24 minutes, with technical success rate of 90% (18/20); in two cases, the patients were successfully reoperated on laparoscopically in 24 hours. The mean hospitalization was 3.6 ± 1.2 days, with 0% (0/20) perioperative and 30-day mortality. No patient underwent open conversion or showed signs of intestinal ischemia. During follow-up of 32.6 ± 12 months, 13 of 20 patients had aneurysm sac regression, whereas the rest had a stable sac diameter without evidence of persistent type II endoleak. CONCLUSIONS: Laparoscopic ligation of the IMA for treatment of type II endoleak after EVAR is a feasible and safe technique in specialized centers with high technical success rate and good midterm outcomes.
Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Laparoscopía , Arteria Mesentérica Inferior/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/fisiopatología , Endofuga/diagnóstico , Endofuga/etiología , Endofuga/fisiopatología , Femenino , Humanos , Laparoscopía/efectos adversos , Ligadura , Masculino , Arteria Mesentérica Inferior/diagnóstico por imagen , Arteria Mesentérica Inferior/fisiopatología , Persona de Mediana Edad , Circulación Esplácnica , Resultado del TratamientoRESUMEN
BACKGROUND: Surgeon modification of commercially available aortic stent grafts represents a salvage option to treat complex aortic pathologies in high-risk patients. TECHNIQUE: A 68-year-old male was referred to our hospital with a contained rupture of the visceral aorta. The patient was previously treated with an infrarenal tube graft 16 years earlier as well as with a Crawford procedure with island patch of the celiac trunk (TC) and the superior mesenteric artery (SMA) and bypasses to both renal arteries 6 years before admission. The computed tomography demonstrated a "blowout aneurysm" of the TC and SMA patch. The bypass to the left renal artery originated from the level of the TC. We therefore modified a commercially available t-branch (Cook® Medical, Bloomington, IN) with surgeon-made fenestrations for both renal arteries. The procedure was successful, and the patient could be discharged to home on the seventh postoperative day. CONCLUSIONS: The use of surgeon-modified "off-the-shelf" t-branches broadens the possibilities of treating even anatomically very challenging aortic pathologies otherwise not suitable for the t-branch.
Asunto(s)
Aneurisma de la Aorta/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Cirujanos , Anciano , Aneurisma de la Aorta/tratamiento farmacológico , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/métodos , Angiografía por Tomografía Computarizada , Humanos , Masculino , Diseño de Prótesis , Resultado del TratamientoRESUMEN
The incidence of primary aorto-enteric fistula (PAEF) is low with only few case reports and case series published. Depending on the location of the PAEF, the perforation leads to upper or lower gastrointestinal haemorrhages. We conducted a MEDLINE search according to the PRISMA statement. Articles with publication dates from 2000 to 2016 were included and present an own case report. We considered all case reports and series reporting on PAEF and identified 85 individual patients from 32 case reports and five case series. The majority of PAEF is associated with atherosclerotic or aneurysmatic findings of the aorta and in particular with inflammatory aortic diseases. Most commonly, the duodenum (64 %) was mentioned as location of the perforation. Other cases involved the jejunum (< 10 %) and the colon (5 %). Almost all patients were diagnosed either with gastrointestinal haemorrhage, abdominal or back pain, or anaemia due to bleeding. The immediate and correct diagnosis of this entity remains difficult. Therefore, treatment is delayed leading to an extraordinary high mortality of almost 100 % in untreated cases. Duplex ultrasound and contrast-enhanced CT angiography have high diagnostic sensitivity and specificity to rule out acute abdominal aortic pathologies. New endovascular approaches can help to lower mortality.
Asunto(s)
Enfermedades de la Aorta/complicaciones , Enfermedades Duodenales/complicaciones , Hemorragia Gastrointestinal/etiología , Fístula Intestinal/complicaciones , Fístula Vascular/complicaciones , Enfermedades de la Aorta/diagnóstico , Autopsia , Resultado Fatal , Hemorragia Gastrointestinal/diagnóstico , Humanos , Fístula Intestinal/diagnóstico , Masculino , Persona de Mediana Edad , Fístula Vascular/diagnósticoRESUMEN
BACKGROUND: Cardiovascular diseases are the leading cause of death in Germany. The knowledge of causal risk factors and their distribution is of utmost importance to design screening programs. PROBANDS AND METHODS: In this cross-sectional study design we used STROBE criteria to achieve the highest comparability possible. Anthropometric measures (height and weight), total cholesterol, glucose level, and blood pressure were measured. Probands' history was collected by using a standardized questionnaire. The data was age- and gender-adjusted for the working population 16 to 70 years of age, derived from the micro census, the 1 %-sample census of the German statistical office. For each study year weight factors were calculated. Logistic regression analysis was conducted regarding the cardiovascular risk factors: smoking, arterial hypertension, diabetes, hypercholesterolemia, and obesity. RESULTS: Between 2006 and 2015 a total of 28,293 employees took part in the ongoing company screenings. The mean age was 42.3 years for both sexes (median: 43 years). The mean body mass index (BMI) was 25.6 kg/m2 (men: 26.5 kg/m2, women: 24.7 kg/m2). A history of hypertension was present in 16 % of the employees (men: 17.8 %, women: 13.8 %). Of the respondents 2 % suffered from diabetes (men: 2.4 %, women: 1.6 %). Lipid-lowering drugs were taken by 2.8 % of all employees (3.6 % men and 1.9 % women). 23.3 % of the men and women indicated to be active smokers. In the regression analysis obesity was associated with a four times higher risk of hypertension and a three times higher risk of elevated glucose levels, thus manifesting as main contributor for vascular diseases. Meanwhile the risk for obesity was 140 % higher in probands who are former smokers. CONCLUSIONS: We regard obesity as the number one cardiovascular risk which should be assessed by various medical, legislative, and socio-economic actions to limit future mortality and health-care costs in Germany.