1.
Radiat Prot Dosimetry ; 144(1-4): 521-4, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21030398

RESUMEN

Unsealed beta-gamma-emitting sources are used (15 GBq (90)Y each session) in nuclear medicine therapeutic procedures. Inside the manipulation cell and while giving the injection to the patient, the skin exposure is very high; electron radiation field is not homogeneous and thus the exposure of the extremities is not uniform. Particular individual monitoring is adopted: single thermoluminescence dosemeter, wrapped in polyethylene film and placed on an adhesive tape, is positioned on the tip of the fingers; 6-10 dosemeters are assigned to each operator per session. The energy and angle response is studied for X-ray spectra, (90)Sr/Y and (204)Tl--a unique mean calibration factor is calculated in order to estimate H(p)(0.07). Performance of dosemeter is analysed according to ISO 62387-1(2007) and the combined uncertainty (calculated using the Monte Carlo method) results lie in the order of 11 %. This method reveals the critical step of manipulation and administration and ensures that dose limits are not exceeded.


Asunto(s)
Cobre/análisis , Fluoruros/análisis , Compuestos de Litio/análisis , Magnesio/análisis , Medicina Nuclear , Exposición Profesional/prevención & control , Fósforo/análisis , Monitoreo de Radiación/instrumentación , Radiometría/instrumentación , Calibración , Humanos , Método de Montecarlo , Medicina Nuclear/métodos , Fotones , Monitoreo de Radiación/métodos , Radiometría/métodos , Radioterapia/métodos , Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente/métodos , Incertidumbre , Recursos Humanos , Radioisótopos de Itrio/análisis
2.
Nucl Med Commun ; 20(11): 1077-84, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10572919

RESUMEN

A multicentre survey of the quality control of 99Tcm generators has been completed: 245 generators from seven different commercial sources were tested over a period of 2 years. The results indicate that the mean pH of the eluates was 5.8 +/- 0.6; the aluminium contents were typically < 10 ppm; the radiochemical purity was 99.8 +/- 0.4% and the median 99Mo content was 3.8 x 10(-4) percent. The elution profiles gave a volume of 1.9 ml to obtain 50% of the total eluted activity and of 4.9 ml to obtain 95%. Other radionuclide impurities and heavy metal breakthrough were evaluated by graphite furnace absorption spectrometry and inductively coupled plasma mass spectrometry. National guidelines for the standardization of radiopharmacy procedures are currently being compiled.


Asunto(s)
Molibdeno/química , Generadores de Radionúclidos/normas , Radiofármacos/normas , Tecnecio/química , Concentración de Iones de Hidrógeno , Indicadores y Reactivos , Italia , Molibdeno/aislamiento & purificación , Control de Calidad , Radioisótopos , Radiofármacos/química , Radiofármacos/aislamiento & purificación , Espectrofotometría Atómica , Tecnecio/aislamiento & purificación , Oligoelementos/análisis
SELECCIÓN DE REFERENCIAS