Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 70(4): 1038-46, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23197329

RESUMEN

At clinical MRI field strengths (1.5 and 3 T), quantitative maps of the longitudinal relaxation time T1 of the myocardium reveal diseased tissue without requiring contrast agents. Cardiac T1 maps can be measured by Look-Locker inversion recovery sequences such as ShMOLLI at 1.5 and 3 T. Cardiovascular MRI at a field strength of 7 T has recently become feasible, but doubts have remained as to whether magnetization inversion is possible in the heart due to subject heating and technical limitations. This work extends the repertoire of 7 T cardiovascular MRI by implementing an adiabatic inversion pulse optimized for use in the heart at 7 T. A "ShMOLLI+IE" adaptation of the ShMOLLI pulse sequence has been introduced together with new postprocessing that accounts for the possibility of incomplete magnetization inversion. These methods were validated in phantoms and then used in a study of six healthy volunteers to determine the degree of magnetization inversion and the T1 of normal myocardium at 7 T within a 22-heartbeat breathhold. Using a scanner with 16 × 1 kW radiofrequency outputs, inversion efficiencies ranging from -0.79 to -0.83 (intrasegment means; perfect 180° would give -1) were attainable across the myocardium. The myocardial T1 was 1925 ± 48 ms (mean ± standard deviation).


Asunto(s)
Algoritmos , Ventrículos Cardíacos/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Función Ventricular Izquierda/fisiología , Femenino , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Magn Reson Med ; 61(1): 244-8, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19097214

RESUMEN

The objective of this study was to investigate the feasibility of whole-body imaging at 7T. To achieve this objective, new technology and methods were developed. Radio frequency (RF) field distribution and specific absorption rate (SAR) were first explored through numerical modeling. A body coil was then designed and built. Multichannel transmit and receive coils were also developed and implemented. With this new technology in hand, an imaging survey of the "landscape" of the human body at 7T was conducted. Cardiac imaging at 7T appeared to be possible. The potential for breast imaging and spectroscopy was demonstrated. Preliminary results of the first human body imaging at 7T suggest both promise and directions for further development.


Asunto(s)
Algoritmos , Mama/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen de Cuerpo Entero/métodos , Estudios de Factibilidad , Femenino , Humanos , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...