Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38731065

RESUMEN

Background: This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period. Methods: Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient's eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control. Results: In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals (p < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group. Conclusions: XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

2.
J Glaucoma ; 33(5): 375-380, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38129940

RESUMEN

PRCIS: This study showed that the XEN patency should be verified by OCT imaging in cases of encapsulated blebs. Although fibrosis plays the principal role, humor aqueous flow reduction could affect the "spacer" effect that inhibits the fibroblast attachments. PURPOSE: To evaluate the application of the anterior segment optical coherence tomography (AS-OCT) imaging in studying the relationship between a low flow rate through the XEN63 and the development of a cystic bleb. METHODS: Retrospective case series of 3 eyes presenting a cystic bleb after an XEN63 implantation for uncontrolled intraocular pressure (IOP). Demographic and clinical data were obtained from medical records. The imaging findings, complications, and managements following the surgery were evaluated. RESULTS: Three patients, with an average age of 67.3 years, initially showed a patent stent lumen and a functional bleb after surgery. The IOP of all eyes increased on average at 28.3 days from the surgery, with a mean value of 39.66 mm Hg. The slit lamp examination showed a cystic bleb. The AS-OCT imaging confirmed the previous finding and revealed either a partial or total occlusion of the stent internal ostium. A Nd:YAG laser, in proximity to the ostium, was performed to resolve the obstruction. Although the AS-OCT imaging showed the device patency and the IOP immediately decreased, the latter became elevated again. Consequently, in all the cases, a further needling procedure was needed to achieve an adequate IOP reduction. Six months after the two-step procedure, the IOP averaged 13.33 mm Hg, the XEN63 lumens appeared cleared, and the blebs showed a functional morphology. No adverse events were observed. CONCLUSION: The development of a cystic bleb may result from an altered balance between the flow rate through the XEN63 and the fibrosis development in the postoperative healing process. A proper follow-up based on slit lamp biomicroscopy, IOP measurement, and AS-OCT imaging is advisable to estimate and manage a cystic bleb following XEN63 implantation.


Asunto(s)
Segmento Anterior del Ojo , Implantes de Drenaje de Glaucoma , Presión Intraocular , Anciano , Femenino , Humanos , Persona de Mediana Edad , Segmento Anterior del Ojo/diagnóstico por imagen , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Hipertensión Ocular/diagnóstico , Complicaciones Posoperatorias , Estudios Retrospectivos , Stents , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular
3.
Pharmaceuticals (Basel) ; 16(10)2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37895903

RESUMEN

Pregnancy is a medical condition in which the physiological changes in the maternal body and the potential impact on the developing fetus require a cautious approach in terms of drug administration. Individual treatment, a thorough assessment of the extent of the disease, and a broad knowledge of the therapeutic options and different routes of administration of ophthalmic drugs are essential to ensure the best possible results while minimizing risks. Although there are currently several routes of administration of drugs for the treatment of eye diseases, even with topical administration, there is a certain amount of systemic absorption that must be taken into account. Despite continuous developments and advances in ophthalmic drugs, no updated data are available on their safety profile in these contexts. The purpose of this review is both to summarize the current information on the safety of ophthalmic treatments during pregnancy and lactation and to provide a practical guide to the ophthalmologist for the treatment of eye diseases while minimizing harm to the developing fetus and addressing maternal health needs.

4.
Cureus ; 15(3): e36216, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37073199

RESUMEN

An accidental injection of a dexamethasone implant inside the crystalline lens was observed in the right eye of a 63-year-old woman suffering from a macular edema secondary to a central retinal vein occlusion. A 23-gauge pars plana vitrectomy and lensectomy followed by an intraocular lens implantation were performed to carefully remove the lens and save the whole implant in order to preserve its therapeutics effects. A strict follow-up over the following 3 months revealed an improving of macular edema and no postoperative complications. The injection of a dexamethasone implant into the lens could be effectively and successfully managed with a pars plana vitrectomy and lensectomy.

5.
Eur J Ophthalmol ; 33(6): 2285-2289, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36987589

RESUMEN

PURPOSE: To evaluate efficacy and safety of intraoperative cryoretinopexy in cases of rhegmatogenous retinal detachment (RRD). METHODS: In this retrospective, interventional case series, we review the medical records of 85 consecutive cases of RRD treated with pars plana vitrectomy and gas tamponade, without the use of perfluorocarbon liquids. Baseline best-corrected visual acuity, intraocular pressure, number and location of retinal breaks, location and extension of retinal detachment, duration of symptoms, macula status, presence, and grade of proliferative vitreoretinopathy (PVR) were registered. Follow-up visits were at 1 day, 15 days, 1 month and 3 months. Anatomical and functional outcomes and any adverse event were recorded. RESULTS: Primary anatomical success was obtained in 82/85 patients (96%). During the postoperative period, PVR was observed in 4/85 cases (4.7%), 3 of whom developed recurrence of retinal detachment. 7/85 (8.2%) patients developed ocular hypertension. We built a model of logistic regression including age, sex, lens status, macula status, number of quadrants involved, number of ruptures and duration of symptoms. None of the variables considered was found to be a predictor of postoperative PVR development. Symptom's duration (ß = 0.429; 95% CI = 0.009-0.023; P < 0.001) and preoperative BCVA (ß = 0.273; 95% CI = 0.034-0.184; P = 0.005) were predictors for final BCVA. CONCLUSION: These findings emphasize the safety and efficacy of the use of intraoperative cryotherapy, associated with PPV and gas tamponade, for the management of uncomplicated RRDs.

6.
Healthcare (Basel) ; 11(3)2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-36766862

RESUMEN

The COVID-19 pandemic has hampered the optimum management of retinal diseases. This study examined the impact of the pandemic on the intravitreal-injection practice in two academic centers in Italy along with the related medico-legal implications. A retrospective analysis of electronic medical records from 16 March 2020 to 14 March 2021 at the ophthalmological departments of University of Cagliari (SGD) and University Magna Græcia of Catanzaro (UMG) was conducted. The data collected between 16 March 2020 and 14 June 2020 (lockdown), 15 June 2020 and 13 September 2020 (unlock), and 14 September 2020 and 14 March 2021 (second wave) were compared with those of the same period of the previous year. Weekly data on the administered drug and the number and type of treated disease were collected and analyzed. During the lockdown, a drop of 59% at SGD (p < 0.00001) and 77% at UMG (p < 0.00001) in intravitreal injections was found. In the first year of the pandemic, the reduction in injections was approximately of 27% (p < 0.0008) and 38% (p < 0.0001) at SGD and UMG, respectively. The COVID-19-related containment measures and the health resources redistribution have led to a delay in the treatment of chronic diseases of the retina, prioritizing the undeferrable ones. The lack of management guidelines has conceived relevant ethical and medico-legal issues that need to be considered in future measures planning.

7.
Life (Basel) ; 12(10)2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-36294925

RESUMEN

The aim of this study was to investigate ocular surface changes associated with face mask (FMs) use of healthcare personnel during the COVID-19 pandemic. We prospectively evaluated 200 eyes of 100 individuals during working hours and 40 eyes of 20 individuals during their rest days as a control group. Dry eye symptoms were assessed with the Ocular Surface Disease Index (OSDI) and McMonnies questionnaire. The clinical investigation included the best corrected visual acuity (BCVA), corneal fluorescein staining (FS), break-up time (BUT), and Schirmer test I before and after a 7-h work shift with a continuative use of surgical or N95 masks. The control group was evaluated similarly twice a day, at 8:00 a.m. and at 3:00 p.m.. In the study group, BCVA, FS, BUT, and Schirmer test were investigated and there was a significant negative variation at the end of the shift. On the contrary, the control group did not show significant variations of any clinical feature. Furthermore, no significant changes in clinical parameters were observed during the use of surgical or N95 masks. In conclusion, FMs continuative use resulted in daily ocular surface modifications specifically in healthcare personnel.

8.
Am J Ophthalmol Case Rep ; 27: 101626, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35761878

RESUMEN

Purpose: To describe a case of an infective vitreitis with an exudative retinal detachment in a 56-year-old lady who was previously affected by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Observations: A broad workup for infections including the main viruses and bacteria was performed. Salivary droplets, tear film and vitreous samples were collected, resulting positive only for Epstein-Barr virus (EBV). Viraemia and immunoglobulin M for EBV negative, whereas immunoglobulin G positive. The patient showed a simultaneous painless erosion on the right margin of the tongue that's with the lab swab demonstrated the presence of EBV at the same time the vitreitis in the left eye was present. Conclusions and Importance: Our speculation is that a continuous use of the mask, especially in immunocompromised subjects, it might create a new route for spreading infectious oral agents in the ocular area, and this case is a warning for all the ophthalmologists that have to be aware of this threatening possibility in the COVID era.

9.
J Clin Med ; 12(1)2022 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-36614951

RESUMEN

The aim of this study was to evaluate the choroidal vascularity analyzing en face optical coherence tomography (OCT) images in patients with unilateral central serous chorioretinopathy (CSC). We retrospectively evaluated 40 eyes of 20 CSC patients and 20 eyes of 10 gender- and age-matched healthy individuals. The sample consisted of: (1) CSC affected eyes; (2) unaffected fellow eyes; (3) healthy eyes. Multiple cross-sectional enhanced depth imaging OCT scans were obtained to create a volume scan. En face scans of the whole choroid were obtained at 5µm intervals and were binarized to calculate the choroidal vascularity index (CVI). The latter, defined as the proportion of the luminal area to the total choroidal area, was calculated at the level of choriocapillaris, superficial, medium and deep layers. No significant differences between choriocapillaris, superficial, medium and deep CVI were found in both eyes of CSC patients, whereas a significant different trend of changes was found in healthy eyes. Nevertheless, the en face CVI shows no difference between affected fellow and healthy eyes. In conclusion, CSC-affected eyes and fellow eyes showed a similar vascular architecture, with no statistical difference between all choroidal layers.

10.
BMC Ophthalmol ; 21(1): 446, 2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-34961501

RESUMEN

BACKGROUND: Despite the XEN gel stent low-risk profile, various complications following the implant have been described, including internal and external occlusion, with a consequent postoperative rise in intraocular pressure (IOP). In this case report we aimed to present a XEN45 stent internal occlusion successfully treated by trimming in situ its proximal end with a 25 G vitreous scissors using a bimanual technique. CASE PRESENTATION: A 63-year-old male patient affected by primary open angle glaucoma (IOP = 25 mmHg) and a full thickness macular hole in his right eye, underwent ab-interno Xen gel stent implantation and, 1 month later, a 25 G vitrectomy surgery. Despite a significant IOP reduction after stent implant, 6 days after vitrectomy, IOP increased (25 mmHg) and the conjunctival bleb flattened following occlusion of stent internal ostium by a clot of presumed fibrinous material. The Nd:YAG laser failed to remove the clot, so that we decided to snip a small bit of the proximal end of the Xen tube (about 0,5 mm length) with a 25 G vitreous scissors, using a bimanual technique. In the postoperative day 1 and month 1, the IOP was 8 mmHg and 12 mmHg, respectively. The Anterior Segment OCT confirmed a functional, layered, filtering bleb, and the normal appearance and patency of the XEN proximal segment. No side effects from the intervention were observed. CONCLUSIONS: Ab interno trimming with vitreous scissors of the occluded proximal end of the XEN stent may represent a safe, rapid and efficient method to restore aqueous humor subconjunctival drainage.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Glaucoma de Ángulo Abierto/cirugía , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Stents , Tonometría Ocular , Resultado del Tratamiento
11.
Am J Ophthalmol Case Rep ; 22: 101070, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33763622

RESUMEN

PURPOSE: To report an unusual non-iatrogenic case of central macular and posterior full-thickness retinal holes (FTRHs). OBSERVATIONS: A 60-year-old man presented with a progressive visual loss in the right eye. A complete ophthalmological evaluation including best corrected visual acuity (BCVA) measurement, fundus examination and spectral - domain optical coherence tomography (SD-OCT) was performed.Fundus examination and SD-OCT confirmed the presence of simultaneous macular and posterior FTRHs. A 25-gauge vitrectomy was performed and the internal limiting membrane (ILM) was grasped and peeled off around the two holes. A fragment of the peeled-off ILM anchored on the FTRHs edges was left and inserted into the gaps.Closure of both retinal holes was achieved at 1-month, and BCVA improved from 20/630 at baseline to 20/63 at month 3. No intraoperative or postoperative complications were recorded. CONCLUSIONS AND IMPORTANCE: Inverted ILM flap technique represents a good treatment option in this rare non-iatrogenic condition, allowing a good anatomical and functional recovery.

13.
Drug Des Devel Ther ; 13: 2001-2008, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31354245

RESUMEN

Background: Effective and tolerable therapeutic strategies for patients with refractory persistent epithelial defects (PEDs) are limited and generally provide poor outcomes. This retrospective case review describes four refractory cases of PEDs associated with recurrent corneal erosions (RCEs) and dry eye disease (DED), which were successfully treated with cyclosporine eye drops. Methods: Patients were treated with cyclosporine A 0.05% eye drops twice a day for at least 12 months. At enrolling time, each patient was asked to suspend topical steroids or other eye drops used for ocular surface abnormalities with the exception of lubricants and eye washing. A complete evaluation of ocular surface symptoms was performed including the McMonnies Dry Eye Questionnaire, Ocular Surface Disease Index, slit-lamp biomicroscopy, fluorescein break-up time, the fluorescein staining of the cornea and conjunctiva (according to the Oxford grading system), the Schirmer I test, and the meibomian secretion after digital pressure application on the lids. This set of exams was carried out at baseline and repeated at all follow-up assessments. Results: All participants that did not benefit from previous therapies, including corticosteroids tapering schedule, showed an important improvement in the clinical picture after two months with topical cyclosporine medication. Moreover, after 12 months of continuous therapy, all patients showed a clinical improvement in DED signs and symptoms, related to the absence of new RCE episodes. The treatment was well tolerated, and no adverse effects were reported. Conclusion: Although a small number of cases were available of our analysis, the treatment with cyclosporine eye drops represents a promising approach in the management of refractory PEDs with associated ocular comorbidities, since it may reduce the RCE episodes and improve the tear film stability, in absence of systemic or local side effects.


Asunto(s)
Enfermedades de la Córnea/tratamiento farmacológico , Ciclosporina/farmacología , Síndromes de Ojo Seco/tratamiento farmacológico , Epitelio Corneal/efectos de los fármacos , Soluciones Oftálmicas/farmacología , Administración Tópica , Adulto , Enfermedades de la Córnea/patología , Ciclosporina/administración & dosificación , Síndromes de Ojo Seco/patología , Epitelio Corneal/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas/administración & dosificación , Tamaño de la Partícula , Estudios Retrospectivos , Propiedades de Superficie
14.
PLoS One ; 13(11): e0207891, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30496218

RESUMEN

PURPOSE: To evaluate the feasibility of 3D anterior segment optical coherence tomography (AS-OCT) for the detection of corneal endothelial features in patients with Fuchs' Endothelial Corneal Dystrophy (FECD). METHODS: Twenty patients with clinical diagnosis of FECD (group A), and 20 control subjects (group B) were enrolled. In all patients a complete ophthalmological examination was performed, including best corrected visual acuity (BCVA), slit lamp examination for subjective grading of FECD and corneal endothelial specular microscopy. A 512x128 AS-OCT cube centered on the corneal apex was performed, and then the inner surface of the cornea was visualized and analyzed individually. RESULTS: Overall, the study participants were adults (mean age was 57.35 ± 8.45 years [mean ± SD] 80% female) with a BCVA ranged from 1.3 to 0 LogMAR. The OCT analysis disclosed three different patterns of the corneal endothelium (1, 2, 3) according to the signal distribution and the level of reflectivity: a homogenous, hypo-reflective surface (pattern 1); the presence of hyper-reflective orange-yellowish points (pattern 2); and a mottled appearance with a variable number of hyper-reflective areas (pattern 3). The distributions of these morphological models in the two populations were as follows: patterns 1, 2 and 3 were observed respectively in 0%, 80%, and 20% of patients in group A, and in 80%, 20% and 0% of subjects in group B. Correlation analysis unveiled a positive relationship between OCT corneal endothelium reflectivity and the clinical severity score (assessed with biomicroscopy), as well as an inverse relationship between the OCT pattern and the integrity of corneal endothelium. CONCLUSION: 3D AS-OCT is a useful tool in investigation of endothelial features and therefore may represent a valuable support in the setting of FECD diagnosis and staging.


Asunto(s)
Endotelio Corneal/diagnóstico por imagen , Distrofia Endotelial de Fuchs/diagnóstico por imagen , Imagenología Tridimensional , Tomografía de Coherencia Óptica , Estudios de Casos y Controles , Endotelio Corneal/patología , Estudios de Factibilidad , Femenino , Distrofia Endotelial de Fuchs/patología , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...