Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Pathogens ; 10(7)2021 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-34357989

RESUMEN

During the coronavirus disease 2019 (COVID-19) pandemic, several case studies demonstrated that many asymptomatic patients with COVID-19 underwent fluorine-18 fluorodeoxyglucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) examination for various indications. However, there is a lack of literature to characterize the pattern of [18F]FDG PET/CT imaging on asymptomatic COVID-19 patients. Therefore, a systematic review to analyze the pulmonary findings of [18F]FDG PET/CT on asymptomatic COVID-19 patients was conducted. This systematic review was performed under the guidelines of PRISMA. PubMed, Medline, and Web of Science were used to search for articles for this review. Articles with the key words: "asymptomatic", "COVID-19", "[18F]FDG PET/CT", and "nuclear medicine" were searched for from 1 January 2020 to 20 May 2021. Thirty asymptomatic patients with COVID-19 were included in the eighteen articles. These patients had a mean age of 62.25 ± 14.85 years (male: 67.71 ± 12.00; female: 56.79 ± 15.81). [18F]FDG-avid lung lesions were found in 93.33% (28/30) of total patients. The major lesion was [18F]FDG-avid multiple ground-glass opacities (GGOs) in the peripheral or subpleural region in bilateral lungs, followed by the consolidation. The intensity of [18F]FDG uptake in multiple GGOs was 5.605 ± 2.914 (range from 2 to 12) for maximal standardized uptake value (SUVmax). [18F]FDG-avid thoracic lymph nodes (LN) were observed in 40% (12/40) of the patients. They mostly appeared in both mediastinal and hilar regions with an SUVmax of 5.8 ± 2.93 (range from 2.5 to 9.6). The [18F]FDG uptake was observed in multiple GGOs, as well as in the mediastinal and hilar LNs. These are common patterns in PET/CT of asymptomatic patients with COVID-19.

2.
Sensors (Basel) ; 18(8)2018 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-30096759

RESUMEN

In this study, we study a heat transfer model, with the surface of the microbolometer device receiving radiation from blackbody constructed using a COMSOL Multiphysics simulator. We have proposed three kinds of L-type 2-leg and 4-leg with the pixel pitch of 35 µm based on vanadium oxide absorbent membrane sandwiched with top passivated and bottom Si3N4 supporting films, respectively. Under the blackbody radiation, the surface temperature changes and distributions of these samples are simulated and analyzed in detail. The trend of change of the temperature dependent resistance of the four kinds of bolometer devices using the proposed heat transfer model is consistent with the actual results of the change of resistance of 4 samples irradiated with 325 K blackbody located in the front distance of 5 cm. In this paper, ΔT indicates the averaged differences of the top temperature on the suspended membrane and the lowest temperature on the post of legs of the microbolometers. It is shown that ΔT ≈ 17 mK is larger in nominal 2-leg microbolometer device than that of 4-leg one and of 2-leg with 2 µm × 2 µm central square hole and two 7.5 µm × 2 µm slits in suspended films. Additionally, only ΔT ≈ 5 mK with 4-leg microbolometer device under the same radiated energy of 325 K blackbody results from the larger total thermal conductance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA