Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Pediatrics ; 146(1)2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32393606

RESUMEN

BACKGROUND: In the United States in 2019, there was an outbreak of electronic cigarette, or vaping, product use-associated lung injury (EVALI). The manifestations of EVALI in adolescents are not well characterized. We describe the diagnosis, evaluation, and management of EVALI in adolescents hospitalized at a tertiary care, university-affiliated children's hospital. METHODS: A multidisciplinary committee developed an EVALI algorithm on the basis of guidelines from the Centers for Disease Control and Prevention. A retrospective chart review was conducted on patients diagnosed with EVALI. Descriptive analyses included sociodemographic characteristics, clinical presentation, laboratory and imaging results, pulmonary function testing, oxygen requirements, and clinic follow-up. RESULTS: Thirteen hospitalized adolescents were diagnosed with confirmed or probable EVALI. The majority were female (54%) with a mean age of 15.9 years. Sixty-nine percent of patients presented with respiratory symptoms, whereas gastrointestinal symptoms were prominent in 85% of patients. Vaping Δ-9-tetrahydrocannabinol was reported in 92% of patients, and vaping nicotine was reported in 62% of patients. All had bilateral ground-glass opacities on the chest computed tomography (CT) scan. Treatment with glucocorticoids led to clinical improvement in 11 of 12 patients. Treatment with glucocorticoids led to improvement in both forced expiratory volume in 1 second and forced vital capacity (P < .05). Four patients required home oxygen on the basis of 6-minute walk test results. CONCLUSIONS: Diagnosis of EVALI should be suspected on the basis of vaping history and clinical presentation. Glucocorticoid treatment led to an improvement in symptoms and lung function. The 6-minute walk test may help determine oxygen needs at discharge.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Lesión Pulmonar/epidemiología , Lesión Pulmonar/etiología , Vapeo/efectos adversos , Vapeo/epidemiología , Adolescente , Femenino , Humanos , Lesión Pulmonar/diagnóstico , Lesión Pulmonar/terapia , Masculino , Estudios Retrospectivos , Estados Unidos/epidemiología
2.
Radiology ; 295(2): 430-438, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32125258

RESUMEN

Background Electronic cigarette or vaping product use-associated lung injury (EVALI) is a serious public health concern with substantial morbidity and mortality, particularly in young individuals. Purpose To evaluate chest radiographic and chest CT findings of EVALI in the pediatric population. Materials and Methods This was a retrospective study of children who presented to a tertiary pediatric hospital from December 2018 to December 2019. Patients fulfilled the Centers for Disease Control and Prevention criteria for EVALI and had chest radiographs and CT images available at initial presentation. Two pediatric radiologists independently reviewed imaging for pattern, distribution, and extent of pulmonary abnormalities, as well as for extrapulmonary abnormalities. Clinical information, management, and outcomes were reviewed. Interobserver agreement was measured with Cohen κ coefficient. Results Seven male patients (50%) and seven female patients (50%) (mean age, 16 years; range, 13-18 years) were evaluated. All patients underwent chest radiography and CT within 4 days of presentation (range, 0-4 days). Chest radiographic findings included ground-glass opacity in 14 of 14 (100%) and consolidation in eight of 14 (57%). CT findings included ground-glass opacity in 14 of 14 (100%), consolidation in nine of 14 (64%), and interlobular septal thickening in two of 14 (14%). At CT, subpleural sparing was seen in 11 of 14 (79%) and a reversed halo sign was seen in five of 14 (36%). Chest radiographic and CT abnormalities were predominately bilateral in 14 of 14 (100%) and symmetric in 13 of 14 (93%), with lower lobe predominance in seven of 14 (50%). Extent of abnormality was predominately diffuse at both chest radiography and CT. There was almost perfect interobserver agreement between two reviewers for detecting abnormalities on chest radiographs (κ = 0.99; 95% confidence interval: 0.97, 1.00) and CT (κ = 0.99; 95% confidence interval: 0.98, 1.00). Conclusion In pediatric patients, electronic cigarette or vaping product use-associated lung injury is characterized by bilateral symmetric ground-glass opacities, consolidation, and a lower lobe predominance at CT. © RSNA, 2020.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Lesión Pulmonar/inducido químicamente , Lesión Pulmonar/diagnóstico por imagen , Radiografía Torácica , Tomografía Computarizada por Rayos X , Vapeo/efectos adversos , Adolescente , Femenino , Humanos , Masculino , Estudios Retrospectivos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...