Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Interv Card Electrophysiol ; 56(2): 199-203, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29858762

RESUMEN

PURPOSE: Audit has played a key role in monitoring and improving clinical practice. However, audit often fails to drive change as summative institutional data alone may be insufficient to do so. We hypothesised that the practice of attributed audit, wherein each individual's procedural performance is presented will have a greater impact on clinical practice. This hypothesis was tested in an observational study evaluating improvement in fluoroscopy times for AF ablation. METHODS: Retrospective analyses of fluoroscopy times in AF ablations at the Barts Heart Centre (BHC) from 2012-2017. Fluoroscopy times were compared pre- and post- the introduction of attributed audit in 2012 at St Bartholomew's Hospital (SBH). In order to test the hypothesis, this concept was introduced to a second group of experienced operators from the Heart Hospital (HH) as part of a merger of the two institutions in 2015 and change in fluoroscopy times recorded. RESULTS: A significant drop in fluoroscopy times (33.3 ± 9.14 to 8.95 ± 2.50, p < 0.0001) from 2012-2014 was noted after the introduction of attributed audit. At the time of merger, a significant difference in fluoroscopy times between operators from the two centres was seen in 2015. Each operator's procedural performance was shared openly at the audit meeting. Subsequent audits showed a steady decrease in fluoroscopy times for each operator with the fluoroscopy time (min, mean±SD) decreasing from 13.29 ± 7.3 in 2015 to 8.84 ± 4.8 (p < 0.0001) in 2017 across the entire group. CONCLUSIONS: Systematic improvement in fluoroscopy times for AF ablation procedures was noted byevaluating individual operators' performance. Attributing data to physicians in attributed audit can promptsignificant improvement and hence should be adopted in clinical practice.


Asunto(s)
Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/normas , Auditoría Médica , Ablación por Catéter , Estudios Transversales , Femenino , Fluoroscopía , Humanos , Londres , Masculino , Tempo Operativo , Mejoramiento de la Calidad , Radiografía Intervencional , Estudios Retrospectivos
2.
Heart ; 103(15): 1210-1215, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28249993

RESUMEN

OBJECTIVE: Cardiac electrophysiology (EP) procedures can be performed under moderate sedation without the direct involvement of an anaesthetist. However, concerns have been raised over the safety of this approach. This study examines the use of a standardised nurse-led physician-directed sedation protocol for EP procedures to determine the safety of moderate sedation administered by non-anaesthesia personnel who have been trained in sedation techniques. METHODS AND RESULTS: Consecutive EP procedures done under moderate sedation over 12 years at our institution were evaluated. Serious adverse events were defined as (i) procedural death related to sedation; (ii) intubation and ventilation; and (iii) hypotension requiring inotropic support. Reversal of sedation constituted a minor adverse event. Up to 7117 procedures were included. These comprised ablations (55%), devices (43%) and other procedures (2%). A majority of patients were men with a mean age of 61±10 years. 99.98% of procedures were completed successfully without sedation-related serious adverse events. Two patients (0.02%) required anaesthetic support for intubation. Sedation was reversed in 1.2% of procedures with less than 1% requiring reversal because of persistent drop in oxygen saturation, hypoventilation or markedly reduced level of consciousness. There was no significant difference in the patient characteristics, mean doses of sedative agents and procedure types in the group requiring reversal of sedation when compared with the whole cohort. CONCLUSIONS: Our study demonstrates that nurse-led, physician-directed moderate sedation is safe. Anaesthesia services are not required routinely for invasive cardiac EP procedures and should be available on a need basis.


Asunto(s)
Electrofisiología Cardíaca/métodos , Procedimientos Quirúrgicos Cardíacos , Sedación Consciente/métodos , Monitoreo Fisiológico/métodos , Anciano , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
3.
Int J Cardiol ; 222: 57-61, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27454616

RESUMEN

BACKGROUND: Current guidelines for epicardial catheter ablation for ventricular tachycardia (VT) advocate that epicardial access is avoided in anticoagulated patients and should be performed prior to heparinisation. Recent studies have shown that epicardial access may be safe in heparinised patients. However, no data exist for patients on oral anticoagulants. We investigated the safety of obtaining epicardial access on uninterrupted warfarin. METHODS: A prospective registry of patients undergoing epicardial VT ablation over two years was analysed. Consecutive patients in whom epicardial access was attempted were included. All patients were heparinised prior to epicardial access with a target activated clotting time (ACT) of 300-350s. Patients who had procedures performed on uninterrupted warfarin (in addition to heparin) were compared to those not taking an oral anticoagulant. RESULTS: 46 patients were included of which 13 were taking warfarin. There was no significant difference in clinical and procedural characteristics (except INR and AF) between the two groups. Epicardial access was achieved in all patients. There were no deaths and no patients required surgery. A higher proportion of patients in the warfarin group had a drop in haemoglobin of >2g/dL compared to the no-warfarin group (38.5% versus 27.3%, p=0.74) and delayed pericardial drain removal (7.8% versus 3.03%, p=0.47). There was no difference in overall procedural complication rate. No patients required warfarin reversal or blood transfusion. CONCLUSION: Epicardial access can be achieved safely and effectively in patients' anticoagulated with warfarin and heparinised with therapeutic ACT. This may be an attractive option for patients with a high stroke risk.


Asunto(s)
Ablación por Catéter , Heparina , Complicaciones Intraoperatorias/prevención & control , Pericardio/cirugía , Complicaciones Posoperatorias/prevención & control , Accidente Cerebrovascular , Taquicardia Ventricular , Warfarina , Anciano , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Heparina/administración & dosificación , Heparina/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa/métodos , Atención Perioperativa/estadística & datos numéricos , Sistema de Registros/estadística & datos numéricos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/cirugía , Reino Unido , Warfarina/administración & dosificación , Warfarina/efectos adversos
4.
Int J Cardiol ; 207: 157-63, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26803233

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients with ischaemic cardiomyopathy at high risk of ventricular arrhythmias (VA). However, the current indication for ICD prescription needs improvement. Telomere and telomerase in leucocytes have been shown to associate with biological ageing and pathogenesis of cardiovascular diseases. We hypothesised that leucocyte telomere length, load-of-short telomeres and/or telomerase activity are associated with VA occurrence in ischaemic cardiomyopathy patients. METHODS AND RESULTS: 90 ischaemic cardiomyopathy patients with primary prevention ICDs were recruited. 35 had received appropriate therapy from the ICD for potentially-fatal VA while the remaining 55 patients had not. No significant differences in baseline demographic data relevant to telomere biology were seen between the two groups. There was no significant difference in the age and sex adjusted mean telomere length analysed by qPCR between the groups (p=0.88). In contrast, the load-of-short telomeres assessed by Universal-STELA method and telomerase activity by TRAP assay were both higher in patients who had appropriate ICD therapy and were significantly associated with incidence of ICD therapy (p=0.02, p=0.02). ROC analyses demonstrated that the sensitivity and specificity of these telomere dynamics in predicting potentially-fatal VA was higher than the current gold-standard - left ventricular ejection fraction (AUC 0.82 versus 0.47). CONCLUSION: The load-of-short telomeres and telomerase activity had a significant association with ICD therapy (for VA) in ischaemic cardiomyopathy patients. These biomarkers should be tested in prospective studies to assess their clinical utility in predicting VA after myocardial infarction and guiding primary prevention ICD prescription.


Asunto(s)
Cardiomiopatías/metabolismo , Desfibriladores Implantables , Isquemia Miocárdica/metabolismo , Taquicardia Ventricular/metabolismo , Telomerasa/metabolismo , Acortamiento del Telómero/fisiología , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Biomarcadores/metabolismo , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Estudios de Casos y Controles , Estudios Transversales , Activación Enzimática/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Telomerasa/sangre
5.
Heart ; 96(17): 1372-8, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20483892

RESUMEN

OBJECTIVES: To investigate long-term efficacy of catheter ablation for atrial fibrillation (AF) and the impact of ablating complex or fractionated electrograms (CFEs) in addition to pulmonary vein isolation and linear lesions in persistent AF (PeAF). METHODS: Consecutive cases from 2002-2007 were analysed. All the patients underwent a wide-area circumferential ablation with confirmation of electrical isolation. For PeAF, linear lesions were added, with additional targeting of CFE from 2005. Data were collected in a prospective database. Attempts were made to contact all patients for follow-up. RESULTS: 285 patients underwent 530 procedures. The mean (SD) age was 57 (11) years, 75% were male, 20% had structural heart disease and 53% had paroxysmal AF (PAF). The mean number of procedures was 1.9 per patient (1.7 for PAF and 2.0 for PeAF). Procedural complications included stroke or transient ischemic attack in 0.6% and pericardial effusion requiring drainage in 1.7%. During 2.7 years (0.2 to 7.4 years) of follow-up from the last procedure, there were seven deaths (unrelated to their ablation or AF) and three strokes or transient ischemic attack (0.3% per year). Freedom from AF/atrial tachyarrhythmia was 86% for PAF and 68% for PeAF. Late recurrence was 3 per 100 years of follow-up after >3 years. The Kaplan-Meier analysis showed that CFE ablation improved the outcome for PeAF after the first cluster of procedures (p=0.049), with a trend towards improved final outcome (p=0.130). CONCLUSIONS: Long-term freedom from AF is achievable in most patients with PAF and PeAF with low rates of late recurrence. Additional targeting of CFE improves outcome for PeAF. Late adverse events including stroke are few.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Anciano , Ablación por Catéter/efectos adversos , Ablación por Catéter/estadística & datos numéricos , Electrocardiografía , Métodos Epidemiológicos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...