Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(5): e14336, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38664983

RESUMEN

PURPOSE: Ring and tandem (R&T) applicator digitization is currently performed at our institution by manually defining the extent of the applicators. Digitization can also be achieved using solid applicators: predefined, 3D models with geometric constraints. This study compares R&T digitization using manual and solid applicator methods through Failure Modes and Effects Analyses (FMEAs) and comparative time studies. We aim to assess the suitability of solid applicator method implementation for R&T cases METHODS: Six qualified medical physicists (QMPs) and two medical physics residents scored potential modes of failure of manual digitization in an FMEA as recommended by TG-100. Occurrence, severity, and detectability (OSD) values were averaged across respondents and then multiplied to form combined Risk Priority Numbers (RPNs) for analysis. Participants were trained to perform treatment planning using a developed solid applicator protocol and asked to score a second FMEA on the distinct process steps from the manual method. For both methods, participant digitization was timed. FMEA and time data were analyzed across methods and participant samples RESULTS: QMPs rated the RPNs of the current, manual method of digitization statistically lower than residents did. When comparing the unique FMEA steps between the two digitization methods, QMP respondents found no significant difference in RPN means. Residents, however, rated the solid applicator method as higher risk. Further, after the solid applicator method was performed twice by participants, the time to digitize plans was not significantly different from manual digitization CONCLUSIONS: This study indicates the non-inferiority of the solid applicator method to manual digitization in terms of risk, according to QMPs, and time, across all participants. Differences were found in FMEA evaluation and solid applicator technique adoption based on years of brachytherapy experience. Further practice with the solid applicator protocol is recommended because familiarity is expected to lower FMEA occurrence ratings and further reduce digitization times.


Asunto(s)
Braquiterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Braquiterapia/métodos , Braquiterapia/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Neoplasias/radioterapia
2.
J Appl Clin Med Phys ; 25(4): e14261, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38194600

RESUMEN

PURPOSE: To identify high-priority risks in a clinical trial investigating the use of radiation to alleviate COVID-19 pneumonia using a multi-phase failure modes and effects analysis (FMEA). METHODS: A comprehensive FMEA survey of 133 possible causes of failure was developed for the clinical trial workflow (Phase I). The occurrence, severity, and detection risk of each possible cause of failure was scored by three medical physicists. High-risk potential failure modes were identified using the risk priority number (RPN) and severity scores, which were re-scored by 13 participants in radiation oncology (Phase II). Phase II survey scores were evaluated to identify steps requiring possible intervention and examine risk perception patterns. The Phase II participants provided consensus scores as a group. RESULTS: Thirty high-priority failure modes were selected for the Phase II survey. Strong internal consistency was shown in both surveys using Cronbach's alpha (αc ≥ 0.85). The 10 failures with the largest median RPN values concerned SARS-CoV-2 transmission (N = 6), wrong treatment (N = 3), and patient injury (N = 1). The median RPN was larger for COVID-related failures than other failure types, primarily due to the perceived difficulty of failure detection. Group re-scoring retained 8/10 of the highest-priority risk steps that were identified in the Phase II process, and discussion revealed interpretation differences of process steps and risk evaluation. Participants who were directly involved with the trial working group had stronger agreement on severity scores than those who were not. CONCLUSIONS: The high ranking of failures concerning SARS-CoV-2 transmission suggest that these steps may require additional quality management intervention when treating critically ill COVID-19+ patients. The results also suggest that a multi-phase FMEA survey led by a facilitator may be a useful tool for assessing risks in radiation oncology procedures, supporting future efforts to adapt FMEA to clinical procedures.


Asunto(s)
COVID-19 , Análisis de Modo y Efecto de Fallas en la Atención de la Salud , Humanos , Ensayos Clínicos como Asunto , COVID-19/epidemiología , Pulmón , Planificación de la Radioterapia Asistida por Computador/métodos , Medición de Riesgo , SARS-CoV-2
3.
Adv Radiat Oncol ; 8(4): 101242, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37250285

RESUMEN

Purpose: The feasibility of blinding applications for a medical physics residency program has yet to be demonstrated in the literature. We explore the application of an automated approach with human review and intervention to blind applications during the annual medical physics residency review cycle. Methods and Materials: Applications were blinded using an automated process and used for the first phase of residency review in the program. We retrospectively compared self-reported demographic and gender data with blinded and nonblinded cohorts from 2 sequential years of review from a medical physics residency program. Demographic data were analyzed comparing applicants with candidates selected to move to the next phase of the review process. Interrater agreement was also evaluated from the applicant reviewers. Results: We show the feasibility of blinding applications for a medical physics residency program. We observed no more than a 3% difference between the gender selection within the first phase of application review but greater differences when examining race and ethnicity between the 2 methods. The greatest difference was shown to be between Asian and White candidates, where there are statistical differences in the scores in the rubric categories of essay and overall impression. Conclusions: We suggest that each training program critically evaluate its selection criteria for potential sources of bias within the review process. We recommend further critical investigation of processes to promote equity and inclusion to ensure the methods and outcomes are aligned with the mission of the program. Finally, we recommend that the common application provide an option for blinding applications at the source so this can be an option to facilitate efforts for evaluating unconscious bias in the review process.

4.
J Appl Clin Med Phys ; 23(8): e13718, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35829667

RESUMEN

Qualified medical physicists (QMPs) are in a unique position to influence the creation and application of key performance indicators (KPIs) across diverse practices in health care. Developing KPIs requires the involvement of stakeholders in the area of interest. Fundamentally, KPIs should provide actionable information for the stakeholders using or viewing them. During development, it is important to strongly consider the underlying data collection for the KPI, making it automatic whenever possible. Once the KPI has been validated, it is important to setup a review cycle and be prepared to adjust the underlying data or action levels if the KPI is not performing as intended. Examples of specific KPIs for QMPs of common scopes of practice are provided to act as models to aid in implementation. KPIs are a useful tool for QMPs, regardless of the scope of practice or practice environment, to enhance the safety and quality of care being delivered.


Asunto(s)
Indicadores de Calidad de la Atención de Salud , Humanos
5.
J Appl Clin Med Phys ; 23(5): e13565, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35226392

RESUMEN

PURPOSE: Optimization of dosimetric leaf gap (DLG) and transmission is commonly performed through a manual trial and error process, which can lead to sub-optimal values. The purpose of this work is to create an alternative automated optimization process that provides the optimal DLG and transmission pair for use in a clinical setting. METHODS: Utilizing the treatment planning system application programming interface, a phase space of clinically viable DLG and transmission pairs was generated. The phase space contained 51,051 dose planes for DLGs between 0.0  and 2.5 mm and transmission values between 0.01% and 2.5%. Thirteen plans were measured for multiple multileaf collimator types and nominal beam energies. The optimization minimized the mean γ-index and maximized the γ-index pass rate. The optimized values were validated using five plans excluded from the optimization. RESULTS: Of the nominal beam energies and multileaf collimator system (MLC)-type combinations tested, 6/7 showed an increase in γ-index pass rate and a decrease in mean γ-index signifying better agreement between measurement and calculation. When comparing the optimized DLG and transmission values to the clinically implemented values identified via an iterative method, 5/7 energy, and MLC type combinations showed no statistically significant changes. In addition, the optimized values were benchmarked against three Task Group 119 plans with published γ-index pass rates, which had been held out of the optimization. For those plans, the optimized DLG and transmission values provided the same or better γ-index pass rates. CONCLUSION: We presented a novel and viable automated alternative to current approaches of selecting the DLG and transmission parameters. This method will reduce the time required to determine the clinically acceptable DLG and transmission parameters and ensure optimality for the plans included in the optimization.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
6.
J Appl Clin Med Phys ; 22(12): 108-114, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34762336

RESUMEN

This study is the first to report the clinical lifetime of Varian Kapton sealed ion chambers as a retrospective review. The data have been analyzed using ion chamber gain values, daily quality assurance results, monthly quality assurance results, and delivered treatment field data were analyzed to comprehensively review trends. The data show the average lifetimes of the ion chambers from our institution, so other physicists can prepare for replacement. Additionally, we share our experience in performing quality assurance tests to calibrate and validate the radiation beam after ion chamber replacement.


Asunto(s)
Aceleradores de Partículas , Radiometría , Humanos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...