Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Pharm Biomed Anal ; 219: 114915, 2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-35777175

RESUMEN

Nuclear magnetic resonance (NMR) spectrometric methods for the quantitative analysis of pure heparin in crude heparin is proposed. For quantification, a two-step routine was developed using a USP heparin reference sample for calibration and benzoic acid as an internal standard. The method was successfully validated for its accuracy, reproducibility, and precision. The methodology was used to analyze 20 authentic porcine heparinoid samples having heparin content between 4.25 w/w % and 64.4 w/w %. The characterization of crude heparin products was further extended to a simultaneous analysis of these common ions: sodium, calcium, acetate and chloride. A significant, linear dependence was found between anticoagulant activity and assayed heparin content for thirteen heparinoids samples, for which reference data were available. A Diffused-ordered NMR experiment (DOSY) can be used for qualitative analysis of specific glycosaminoglycans (GAGs) in heparinoid matrices and, potentially, for quantitative prediction of molecular weight of GAGs. NMR spectrometry therefore represents a unique analytical method suitable for the simultaneous quantitative control of organic and inorganic composition of crude heparin samples (especially heparin content) as well as an estimation of other physical and quality parameters (molecular weight, animal origin and activity).


Asunto(s)
Heparina , Heparinoides , Animales , Glicosaminoglicanos , Heparina/análisis , Iones , Espectroscopía de Resonancia Magnética/métodos , Control de Calidad , Reproducibilidad de los Resultados , Porcinos
2.
Anal Chem ; 94(9): 3997-4004, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35201769

RESUMEN

Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.


Asunto(s)
Lignina , Calibración , Análisis de los Mínimos Cuadrados , Espectroscopía de Resonancia Magnética , Peso Molecular
3.
J Pharm Biomed Anal ; 212: 114649, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35158188

RESUMEN

Lignin is a promising renewable biopolymer being investigated worldwide as an environmentally benign substitute of fossil-based aromatic compounds, e.g. for the use as an excipient with antioxidant and antimicrobial properties in drug delivery or even as active compound. For its successful implementation into process streams, a quick, easy, and reliable method is needed for its molecular weight determination. Here we present a method using 1H spectra of benchtop as well as conventional NMR systems in combination with multivariate data analysis, to determine lignin's molecular weight (Mw and Mn) and polydispersity index (PDI). A set of 36 organosolv lignin samples (from Miscanthus x giganteus, Paulownia tomentosa and Silphium perfoliatum) was used for the calibration and cross validation, and 17 samples were used as external validation set. Validation errors between 5.6% and 12.9% were achieved for all parameters on all NMR devices (43, 60, 500 and 600 MHz). Surprisingly, no significant difference in the performance of the benchtop and high-field devices was found. This facilitates the application of this method for determining lignin's molecular weight in an industrial environment because of the low maintenance expenditure, small footprint, ruggedness, and low cost of permanent magnet benchtop NMR systems.


Asunto(s)
Lignina , Poaceae , Lignina/química , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Peso Molecular , Poaceae/química
4.
J Pharm Biomed Anal ; 209: 114530, 2022 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-34915326

RESUMEN

NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.


Asunto(s)
Preparaciones Farmacéuticas , Espectroscopía de Resonancia Magnética , Resonancia Magnética Nuclear Biomolecular , Estándares de Referencia , Solventes
5.
ACS Omega ; 6(44): 29516-29524, 2021 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-34778623

RESUMEN

The molecular weight properties of lignins are one of the key elements that need to be analyzed for a successful industrial application of these promising biopolymers. In this study, the use of 1H NMR as well as diffusion-ordered spectroscopy (DOSY NMR), combined with multivariate regression methods, was investigated for the determination of the molecular weight (M w and M n) and the polydispersity of organosolv lignins (n = 53, Miscanthus x giganteus, Paulownia tomentosa, and Silphium perfoliatum). The suitability of the models was demonstrated by cross validation (CV) as well as by an independent validation set of samples from different biomass origins (beech wood and wheat straw). CV errors of ca. 7-9 and 14-16% were achieved for all parameters with the models from the 1H NMR spectra and the DOSY NMR data, respectively. The prediction errors for the validation samples were in a similar range for the partial least squares model from the 1H NMR data and for a multiple linear regression using the DOSY NMR data. The results indicate the usefulness of NMR measurements combined with multivariate regression methods as a potential alternative to more time-consuming methods such as gel permeation chromatography.

6.
Talanta ; 222: 121504, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33167217

RESUMEN

Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated. In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).

7.
Anal Sci ; 36(12): 1467-1471, 2020 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-32801287

RESUMEN

Heparin is an anticoagulant medication that is usually injected subcutaneously. The quality of a set of commercial heparin injections from different producers was examined by NMR, IR, UV-Vis spectroscopies and potentiometric multisensor system. The type of raw material regarding heparin animal origin and producer, heparin molecular weight and activity values were derived based on the non-targeted analysis of 1H NMR fingerprints. DOSY NMR spectroscopy was additionally used to study homogeneity and additives profile. UV-Vis and IR, being cheaper than NMR, combined with multivariate statistics were successfully applied to study excipients composition as well as semi-estimation of activity values. Potentiometric multisensor measurements were found to be an important additional source of information about inorganic composition of finished heparin formulations. All investigated instrumental techniques are useful for finished heparin injections and should be selected according to availability as well as the information and confidence required for a specific sample.


Asunto(s)
Heparina/administración & dosificación , Composición de Medicamentos , Heparina/química , Inyecciones , Control de Calidad
8.
Food Chem ; 310: 125868, 2020 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-31767484

RESUMEN

The aim of this research was to investigate the effect of herring roe phospholipids (PLs) on the oxidative stability of cod liver oil during storage. The effect of PLs on the oxidative stability of cod liver oil was assessed in terms of peroxide value, free fatty acids, secondary oxidation products and pyrrolisation. The results show that the PV was lower in cod liver oil containing PLs (P < 0.05) than in the control without PLs. Benzaldehyde, 2,5-dimethylpyrazine, 2-methyl-2-pentenal, 1-penten-3-ol and 3-methylbutanal were the main volatiles. In addition, significant pyrrolisation was observed after 28 days when PLs were added to cod liver oil. The results suggested that cod liver oil with dispersed PLs was oxidized during storage followed by non-enzymatic browning reactions. The findings indicated that the ratio between pyrroles formed and α-tocopherol may influence the formation of new peroxides and secondary oxidation products.


Asunto(s)
Aceite de Hígado de Bacalao/química , Fosfolípidos/química , Aldehídos/química , Animales , Benzaldehídos/química , Peces , Oxidación-Reducción , Peróxidos/química , alfa-Tocoferol/química
9.
J Pharm Biomed Anal ; 174: 639-643, 2019 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-31279893

RESUMEN

Heparin is a carbohydrate polymer, which is clinically used as an anticoagulant for the treatment of thrombotic disorders. The anticoagulant process is mainly mediated by the interaction of heparin with antithrombin followed by inhibition of clotting factors IIa (FIIa) and Xa (FXa). The influence of polymer disaccharide structure, average molecular weight and impurity profiling (e.g., chloride and water content) was investigated by NMR spectrometry and principal component analysis (PCA) for a representative dataset of porcine heparin samples (n = 509). A significant linear dependence was found between anticoagulant activity and scores on the third principal component (PC3) based on the non-targeted analysis of 1H NMR fingerprints. The correlation between average molecular values and anticoagulant activity for the 24 porcine heparin samples from two manufacturers was linear (R = 0.85) over typical values for porcine heparin preparations. Chloride and water contents were identified as negatively influencing factors for the actual activity values as their presence decrease the "pharmaceutically active" organic part of heparin preparations. Some suggestions regarding manufacturing process are made according to the results.


Asunto(s)
Anticoagulantes/análisis , Heparina/análisis , Espectroscopía de Resonancia Magnética , Animales , Anticoagulantes/química , Cloruros/química , Disacáridos/química , Factor Xa/química , Inhibidores del Factor Xa/análisis , Inhibidores del Factor Xa/química , Heparina/química , Heparina de Bajo-Peso-Molecular/análisis , Modelos Lineales , Peso Molecular , Polímeros/química , Análisis de Componente Principal , Protrombina/química , Porcinos , Agua/química
10.
J Pharm Biomed Anal ; 173: 18-23, 2019 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-31108420

RESUMEN

NMR spectroscopy has become an essential diagnostic tool for pharmaceutical preparations worldwide, with many runs performed annually on a routine basis. In this study multivariate analysis was performed on a big dataset of 990 NMR heparin spectra recorded over six years (2012-2017) in our laboratory. Several steps of statistical analysis of accumulated data were used to differentiate samples according to animal origin (bovine, porcine and ovine heparin), purity grade (crude and purified heparin), distributing company as well as to estimate their closeness to the heparin reference sample (SST) provided by US Pharmacopeia. The projection of new samples on these models can automatically forecast of all mentioned qualitative heparin properties within one minute. NMR data of heparin pharmaceutical preparations provided a good opportunity to demonstrate the potential of exploratory data analysis considering the same sample preparation and acquisition parameters were used.


Asunto(s)
Anticoagulantes/análisis , Heparina/análisis , Espectroscopía de Protones por Resonancia Magnética , Control de Calidad , Animales , Bovinos , Contaminación de Medicamentos/prevención & control , Análisis Multivariante , Análisis de Componente Principal , Estudios Retrospectivos , Ovinos , Porcinos
11.
Forensic Sci Int ; 294: 86-95, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30481665

RESUMEN

Fatty acid conjugates of hydroxy-metabolites of tetrahydrocannabinol (THC) or cannabinol have already been reported as metabolites in rats. In the herein presented investigation, palmitic acid esters of THC and its primary metabolite 11-hydroxy-delta9-tetrahydrocannabinol (11-OH-THC) were synthesized using esterification with palmitic acid chloride. Structural elucidation of the products was conducted using nuclear magnetic resonance spectroscopy (NMR) and liquid chromatography coupled to quadrupole time of flight mass spectrometry (LC-QToF-MS). For the confirmation of a previous cannabis use, body fluids (femoral blood, heart blood, urine, bile) of 27 death cases (all with known cannabis use), including adipose tissue homogenates of six of these cases as well as eleven plasma samples (probably all with regular cannabis use, confirmed by a high 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THC-COOH) concentration (except one sample, >200ng/mL), were tested for THC and its main metabolites 11-OH-THC and THC-COOH using gas chromatography coupled to mass spectrometry (GC-MS). These samples as well as further tissue homogenates of autopsy cases (liver, kidney, brain) were additionally tested for the presence of THC palmitic acid ester or 11-OH-THC palmitic acid diester by means of a liquid chromatographic triple quadrupole mass spectrometric (LC-QQQ-MS) method, in order to evaluate a possible presence of these conjugates in humans. In none of the analyzed samples (in total 196 specimens; plasma (N=11), femoral blood (N=23), heart blood (N=25), urine (N=23), bile (N=27), liver (N=27), kidney (N=27), brain (N=27), adipose tissue (N=6)), palmitic acid esters of THC or 11-OH-THC could be proven. Even if the existence of these esters in human samples cannot be ruled out definitely, suitability as cannabis consumption markers does not seem likely based on our findings.


Asunto(s)
Dronabinol/análogos & derivados , Dronabinol/análisis , Ésteres/análisis , Ácido Palmítico/análisis , Tejido Adiposo/química , Bilis/química , Biomarcadores/análisis , Química Encefálica , Cromatografía de Gases y Espectrometría de Masas , Humanos , Riñón/química , Hígado/química , Espectroscopía de Resonancia Magnética , Fumar Marihuana
12.
Magn Reson Chem ; 2018 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-30277277

RESUMEN

Nuclear magnetic resonance spectrometry (NMR) finds numerous applications in pharmacy, cosmetic, and food control as well as in developing tools for "big data" analysis. However, there remains a need for automated tools to assess instrument system suitability in real time for each particular routine sample. An automated procedure has been introduced to monitor a number of characteristics (resolution, symmetry, and half width) in real time after the measurement of two samples distributed by the vendor (0.3% CHCl3 in acetone-d6 with tetramethylsilane and 2 mM sucrose in H2 O-D2 O). The results over 11 months were discussed in terms of average values, standard deviations, and spectrometer variability. Moreover, multivariate statistical procedure was implemented to evaluate metrics generated from three NMR spectrometers. Performance of three NMR spectrometers (500 MHz with BBO Prodigy Cryoprobe, 500 MHz with BBFOPLUS SmartProbe, and 600 MHz with BBO Cryoprobe) differed significantly. The developed routine was also applied to calculate the performance characteristics during routine quantitative NMR experiments. The procedure was evaluated for NMR spectra of 659 active pharmaceutical ingredients dissolved in CDCl3 , DMSO, and CH3 OD. This test is more preferable than the routine procedure using standard solutions because the performance is estimated separately for each matrix at the specific time point of measurements. Our automated routine is the ideal tool for any NMR laboratory. In full automation, the NMR data are validated directly for each sample, making unnecessary daily measurements of standard solutions and manual evaluation to their NMR spectra.

13.
Anal Bioanal Chem ; 410(30): 7891-7900, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30349990

RESUMEN

Nuclear magnetic resonance (NMR) spectroscopy is widely applied in the field of metabolomics due to its quantitative nature and the reproducibility of data generated. However, one of the main challenges in routine NMR analysis is to obtain valuable information from large datasets of raw data in a high-throughput, automatic, and reproducible manner. In this study, a method to automatically annotate and quantify 12 phospholipids (PLs) in vegetable lecithin (soy, sunflower, rape) and krill oil is introduced. Automated routines were written in MATLAB environment for quantification of phosphatidylcholine (PC), phosphatidylinositol (PI), lyso-phosphatidylcholine (LPC), phosphatidylserine (PS), phosphatidylethanolamine (PE), diphosphatidylglycerol or cardiolipin (DPG), phosphatidylglycerol (PG), and lyso-phosphatidylethanolamine (LPE) in lecithin and of PC, PC-ether, LPC, PE, N-acyl phosphatidylethanolamine (APE), and LPE in krill oil matrix. The routine includes NMR spectra import, extraction of data points, peaking of local minima and local maxima in the data, integration, quantitation against internal standard, reporting of results as Word file, and their importing in our internal database. Our extensive studies on a representative set of more than 1000 lecithin (soy, rape, sunflower) and krill samples showed that the routine can automatically and accurately calculate the concentrations of all PLs. No systematic or proportional differences between automated and manual evaluation were detected. The developed automated program produces accurate results and requires less than 5 s for each analysis. This tool is already used in high-throughput PL analysis of krill and lecithin and will be adjusted to other matrices (egg, milk, chocolate, etc.) as well.


Asunto(s)
Euphausiacea/química , Lecitinas/química , Fosfolípidos/análisis , Verduras/química , Animales , Automatización , Espectroscopía de Resonancia Magnética , Isótopos de Fósforo , Lectinas de Plantas/química , Reproducibilidad de los Resultados , Proteínas de Soja/química
14.
J Pharm Biomed Anal ; 153: 168-174, 2018 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-29494889

RESUMEN

Nuclear magnetic resonance (NMR) spectroscopy is regarded as one of the most powerful and versatile analytical approaches to assure the quality of heparin preparations. In particular, it was recently demonstrated that by using 1H NMR coupled with chemometrics heparin and low molecular weight heparin (LMWH) samples derived from three major animal species (porcine, ovine and bovine) can be differentiated [Y.B. Monakhova et al. J. Pharm. Anal. 149 (2018) 114-119]. In this study, significant improvement of existing chemometric models was achieved by switching to 2D NMR experiments (heteronuclear multiple-quantum correlation (HMQC) and diffusion-ordered spectroscopy (DOSY)). Two representative data sets (sixty-nine heparin and twenty-two LMWH) belonged to different batches and distributed by different commercial companies were investigated. A trend for animal species differentiation was observed in the principal component analysis (PCA) score plot built based on the DOSY data. A superior model was constructed using HMQC experiments, where individual heparin (LMWH) clusters as well as their blends were clearly differentiated. The predictive power of different classification methods as well as unsupervised techniques (independent components analysis, ICA) clearly proved applicability of the model for routine heparin and LMWH analysis. The switch from 1D to 2D NMR techniques provides a wealth of additional information, which is beneficial for multivariate modeling of NMR spectroscopic data for heparin preparations.


Asunto(s)
Heparina de Bajo-Peso-Molecular/metabolismo , Animales , Bovinos , Difusión , Espectroscopía de Resonancia Magnética/métodos , Análisis de Componente Principal/métodos , Control de Calidad , Reproducibilidad de los Resultados , Ovinos , Porcinos
15.
J Pharm Biomed Anal ; 154: 332-338, 2018 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-29571131

RESUMEN

Heparin is a linear, highly sulfated glycosaminoglycan (GAG), which consists of repeating disaccharide units of ß-d-glucuronic acid or α-l-iduronic acid and α-d-glucosamine. While robust analytical approaches exist for the characterization of organic composition of heparin preparations, there is a lack of methods for the simultaneous quantification of inorganic compounds (water, anions, cations) in this matrix. A nuclear magnetic resonance (NMR) spectrometric method for heparin characterization described in US Pharmacopeia was extended to simultaneous analysis of the inorganic ions (sodium, calcium, and chloride), acetate as well as water content. NMR control of these parameters is possible with only one sample preparation according to the US Pharmacopeia using just four sequential NMR experiments (1H, 2D, 23Na, and 35Cl) with a total measurement time less than 20 min. Validation results in terms of precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit-for-purpose for the authentic heparin samples. The quantitative data for a representative set of more than hundred Na- and Ca- heparin and low-molecular weight heparin (LMWH) samples were discussed regarding animal origin and the type of anticoagulant. NMR spectrometry represents a unique analytical method suitable for the simultaneous quantitative control of organic and inorganic composition of heparin.


Asunto(s)
Heparina de Bajo-Peso-Molecular/química , Iones/química , Preparaciones Farmacéuticas/química , Agua/química , Animales , Anticoagulantes/química , Disacáridos/química , Ácido Glucurónico/química , Espectroscopía de Resonancia Magnética/métodos , Reproducibilidad de los Resultados
16.
J Pharm Biomed Anal ; 149: 114-119, 2018 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-29112899

RESUMEN

High resolution (600MHz) nuclear magnetic resonance (NMR) spectroscopy is used to distinguish heparin and low-molecular weight heparins (LMWHs) produced from porcine, bovine and ovine mucosal tissues as well as their blends. For multivariate analysis several statistical methods such as principal component analysis (PCA), factor discriminant analysis (FDA), partial least squares - discriminant analysis (PLS-DA), linear discriminant analysis (LDA) were utilized for the modeling of NMR data of more than 100 authentic samples. Heparin and LMWH samples from the independent test set (n=15) were 100% correctly classified according to its animal origin. Moreover, by using 1H NMR coupled with chemometrics and several batches of bovine heparins from two producers were differentiated. Thus, NMR spectroscopy combined with chemometrics is an efficient tool for simultaneous identification of animal origin and process based manufacturing difference in heparin products.


Asunto(s)
Anticoagulantes/análisis , Heparina de Bajo-Peso-Molecular/análisis , Heparina/análisis , Modelos Químicos , Tecnología Farmacéutica/métodos , Animales , Biotecnología/normas , Bovinos , Análisis Discriminante , Análisis de los Mínimos Cuadrados , Análisis Multivariante , Análisis de Componente Principal , Espectroscopía de Protones por Resonancia Magnética/instrumentación , Espectroscopía de Protones por Resonancia Magnética/métodos , Control de Calidad , Ovinos , Porcinos , Tecnología Farmacéutica/instrumentación , Tecnología Farmacéutica/normas
17.
J Pharm Biomed Anal ; 149: 128-132, 2018 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-29112901

RESUMEN

Apart from the characterization of impurities, the full characterization of heparin and low molecular weight heparin (LMWH) also requires the determination of average molecular weight, which is closely related to the pharmaceutical properties of anticoagulant drugs. To determine average molecular weight of these animal-derived polymer products, partial least squares regression (PLS) was utilized for modelling of diffused-ordered spectroscopy NMR data (DOSY) of a representative set of heparin (n=32) and LMWH (n=30) samples. The same sets of samples were measured by gel permeation chromatography (GPC) to obtain reference data. The application of PLS to the data led to calibration models with root mean square error of prediction of 498Da and 179Da for heparin and LMWH, respectively. The average coefficients of variation (CVs) did not exceed 2.1% excluding sample preparation (by successive measuring one solution, n=5) and 2.5% including sample preparation (by preparing and analyzing separate samples, n=5). An advantage of the method is that the sample after standard 1D NMR characterization can be used for the molecular weight determination without further manipulation. The accuracy of multivariate models is better than the previous results for other matrices employing internal standards. Therefore, DOSY experiment is recommended to be employed for the calculation of molecular weight of heparin products as a complementary measurement to standard 1D NMR quality control. The method can be easily transferred to other matrices as well.


Asunto(s)
Anticoagulantes/química , Biopolímeros/química , Espectroscopía de Resonancia Magnética/métodos , Modelos Químicos , Control de Calidad , Animales , Anticoagulantes/análisis , Anticoagulantes/normas , Calibración , Bovinos , Química Farmacéutica/instrumentación , Química Farmacéutica/métodos , Difusión , Guías como Asunto , Heparina/análisis , Heparina/química , Heparina/normas , Heparina de Bajo-Peso-Molecular/análisis , Heparina de Bajo-Peso-Molecular/química , Heparina de Bajo-Peso-Molecular/normas , Análisis de los Mínimos Cuadrados , Espectroscopía de Resonancia Magnética/instrumentación , Peso Molecular , Estándares de Referencia , Ovinos , Porcinos , Tecnología Farmacéutica/instrumentación , Tecnología Farmacéutica/métodos , Tecnología Farmacéutica/normas
18.
J Pharm Biomed Anal ; 147: 580-589, 2018 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-28583765

RESUMEN

Nuclear magnetic resonance (NMR) is a fast and accurate analytical method. Associated with chemometrics, it gradually becomes more important tool for the pharmaceutical industry. In this review studies dealing with the applications of multivariate analysis to NMR spectroscopic profiles were grouped and discussed according to the analytical problem solved. The following topics were covered: authenticity of medicines according to variety, seasonal and geographical differences of herbal plants; quantitative prediction of pharmacologically relevant parameters; production and batches approval; investigation of drug structure modifications; site-specific natural isotope fractionation (SNIF-NMR) fingerprinting for origin and manufacturer tracking and others. Special focus was put on the heparin authenticity by using 1D and 2D NMR measurements. Finally, further research directions have been outlined. Our review has shown that chemometrics plays an important role for the quality control and authenticity of pharmaceutical products and its role will definitely increase in the future. The discussed approaches are recommended to be implemented during development and production process of pharmaceuticals or in quality control laboratories.


Asunto(s)
Química Farmacéutica/métodos , Espectroscopía de Resonancia Magnética/métodos , Preparaciones Farmacéuticas/análisis , Química Farmacéutica/tendencias , Predicción , Análisis Multivariante , Resonancia Magnética Nuclear Biomolecular/métodos , Preparaciones Farmacéuticas/química
19.
J AOAC Int ; 100(6): 1819-1830, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28664825

RESUMEN

A proton (1H) NMR spectroscopic method was established for the quality assessment of vegetable oils. To date, several research studies have been published demonstrating the high potential of the NMR technique in lipid analysis. An interlaboratory comparison was organized with the following main objectives: (1) to evaluate an alternative analysis of edible oils by using 1H NMR spectroscopy; and (2) to determine the robustness and reproducibility of the method. Five different edible oil samples were analyzed by evaluating 15 signals (free fatty acids, peroxides, aldehydes, double bonds, and linoleic and linolenic acids) in each spectrum. A total of 21 NMR data sets were obtained from 17 international participant laboratories. The performance of each laboratory was assessed by their z-scores. The test was successfully passed by 90.5% of the participants. Results showed that NMR spectroscopy is a robust alternative method for edible oil analysis.


Asunto(s)
Análisis de los Alimentos/métodos , Espectroscopía de Resonancia Magnética/métodos , Aceites de Plantas/análisis , Interpretación Estadística de Datos , Ácidos Grasos no Esterificados/análisis , Análisis de los Alimentos/normas , Análisis de los Alimentos/estadística & datos numéricos , Laboratorios , Espectroscopía de Resonancia Magnética/instrumentación , Aceite de Oliva/análisis , Peróxidos/análisis , Aceites de Plantas/química , Reproducibilidad de los Resultados
20.
Magn Reson Chem ; 55(11): 996-1005, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28561374

RESUMEN

In our recent paper, a new technique for automated spectra integration and quality control of the acquired results in qNMR was developed and validated (Monakhova & Diehl, Magn. Res. Chem. 2017, doi: 10.1002/mrc.4591). The present study is focused on the influence of acquisition and postacquisition parameters on the developed automated routine in particular, and on the quantitative NMR (qNMR) results in general, which has not been undertaken previously in a systematic and automated manner. Results are presented for a number of model mixtures and authentic pharmaceutical products measured on 500- and 600-MHz NMR spectrometers. The influence of the most important acquisition (spectral width, transmitter [frequency] offset, number of scans, and time domain) and processing (size of real spectrum, deconvolution, Gaussian window multiplication, and line broadening) parameters for qNMR was automatically investigated. Moderate modification of the majority of the investigated parameters from default instrument settings within evaluated ranges does not significantly affect the trueness and precision of the qNMR. Lite Gaussian window multiplication resulted in accuracy improvement of the qNMR output and is recommended for routine measurements. In general, given that the acquisition and processing parameters were selected based on the presented guidelines, automated qNMR analysis can be employed for reproducible high-precision concentration measurements in practice.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...