Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Pediatr ; 11: 1221766, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38444769

RESUMEN

Objective: To calculate the multivessel color Doppler indices in high-risk and low-risk pregnancies and relate these to fetal outcomes. Methods: The investigation involved 60 patients who were pregnant. The patients were separated into groups according to assessment of low and high risk. The patients underwent color Doppler ultrasonography to detect the maternal and fetal blood vessels, and the measured Doppler indices were then analyzed for any association with fetal outcomes. Results: The gestational stages (in weeks) of the participants at the respective times of investigation and delivery were 32.06 ± 2.98 and 36.2 ± 1.78 in the low-risk group and 29.21 ± 1.95 and 29.83 ± 1.86 in the high-risk group. The pulsatility index (PI), resistive index (RI), and systolic/diastolic ratio (SD) decreased with gestation length in the low-risk group, whereas in the high-risk group, these values increased in the uterine and umbilical arteries. With increased gestational stage, MCA-PSV (peak systolic velocity) in the middle cerebral artery (MCA) increased, while PI decreased. Pulsatile and reversal flow of the uterine vein, the vein of Galen, and the umbilical vein were noted in high-risk pregnancies, and these negatively affected the fetal outcome. The fetal venous parameters were more specific and sensitive for predicting an unfavorable fetal outcome than the arterial factors, with a greater negative predictive value. Conclusion: The results of our study indicate that abnormal Doppler indices of the blood vessels in high-risk pregnant patients will result in adverse clinical outcomes. Therefore, the patients can be monitored and managed accordingly using Doppler ultrasonography.

2.
Saudi J Biol Sci ; 28(3): 1678-1686, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33732053

RESUMEN

OBJECTIVES: The primary purpose of the recent experiment was to scrutinize the dissimilarity between single and multiple exposures by electrotherapeutic modalities to determine the development of Gram-positive and Gram negative bacteria spectrum. MATERIAL AND METHODS: Bacterial strains employed in this study were Gram-negative bacteria such as Pseudomonas aeruginosa, Escherichia coli, and Klebsiella pneumonae and Gram-positive bacteria such as Staphylococcus aureus, Staphylococcus saprophyticus and Streptococcus pyogenes. Fluence for Low level laser therapy (LLLT) (810 nm) was 40 J/cm2 for 80 s, for microwave (MWD) a dosage of 100-Watt with duration of 5 min and for magnetic field therapy (MT) duration of 30 min with 100% intensity was used. RESULTS: Repeated Measures of analysis of variances (RANOVA) for within-subject effects was used to detect a global significant change within the means at dissimilar time points. The experiments of within-subjects revealed a significant difference within groups, df of (3, 40), F value of 39.38 and a p value less than 0.001, representing a significant variation between the three groups between pre and post exposures. There was a significant variation between single exposure and multiple exposures in the experimental sample's pre-post between the four groups with df (1, 40) f value of 2943.69 and p value less than 0.001. Scanning and Transmission electron microscopy images were also taken into account to determine the extent of damage caused to the bacterial cells surface topography in Gram negative and Gram positive spectrums. CONCLUSION: The study demonstrated that single high exposure with the LLLT appears to have the most emphatic effect followed by exposure by MWD and MT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...