J Anal Methods Chem ; 2023: 2765508, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36760655

RESUMEN

The need for analytical methods that are fast, affordable, and ecologically friendly is expanding. Because of its low solvent consumption, minimal waste production, and speedy analysis, capillary electrophoresis is considered a "green" choice among analytical separation methods. With these "green" features, we have utilized the capillary electrophoresis method with capacitively coupled contactless conductivity detection (CE-C4D) to simultaneously determine glucosamine and Ca2+ in dietary supplements. The CE analysis was performed in fused silica capillaries (50 µm inner diameter, 40 cm total length, 30 cm effective length), and the analytical time was around 5 min. After optimization, the CE conditions for selective determination of glucosamine and Ca2+ were obtained, including a 10 mM tris (hydroxymethyl) aminomethane/acetic acid (Tris/Ace) buffer of pH 5.0 as the background electrolyte; separation voltage of 20 kV; and hydrodynamic injection (siphoning) at 25 cm height for 30 s. The method illustrated good linearity over the concentration range of 5.00 to 200 mg/L of for glucosamine (R 2 = 0.9994) and 1.00 to 100 mg/L for Ca2+ (R 2 = 0.9994). Under the optimum conditions, the detection limit of glucosamine was 1.00 mg/L, while that of Ca2+ was 0.05 mg/L. The validated method successfully analyzed glucosamine and Ca2+ in seven dietary supplement samples. The measured concentrations were generally in line with the values of label claims and with cross-checking data from reference methods (HPLC and ICP-OES).

2.
Artículo en Inglés | MEDLINE | ID: mdl-28609698

RESUMEN

The employment of a purpose-made capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C4D) as a simple and cost-effective solution for clinical screening of paraquat in plasma samples for early-stage diagnosis of acute herbicide poisoning is reported. Paraquat was determined using an electrolyte composed of 10mM histidine adjusted to pH 4 with acetic acid. A detection limit of 0.5mg/L was achieved. Good agreement between results from CE-C4D and the confirmation method (HPLC-UV) was obtained, with relative errors for the two pairs of data better than 20% for 31 samples taken from paraquat-intoxicated patients. The results were used by medical doctors for identification and prognosis of acute paraquat poisoning cases. The objective of the work is the deployment of the developed approach in rural areas in Vietnam as a low-cost solution to reduce the mortality rate due to accidental or suicidal ingestion of paraquat.


Asunto(s)
Electroforesis Capilar/métodos , Paraquat/sangre , Intoxicación , Conductividad Eléctrica , Hemoperfusión , Humanos , Límite de Detección , Paraquat/envenenamiento , Intoxicación/sangre , Intoxicación/diagnóstico , Intoxicación/terapia , Reproducibilidad de los Resultados , Vietnam
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...