Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
BMJ ; 384: e078581, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38443074

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. DESIGN: Prospective multicentre diagnostic accuracy study. SETTING: 14 medical centres in China. PARTICIPANTS: 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. MAIN OUTCOME MEASURES: The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. RESULTS: ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. CONCLUSION: The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT03748563.


Asunto(s)
Endoscopía Capsular , Várices Esofágicas y Gástricas , Várices , Adulto , Humanos , Várices Esofágicas y Gástricas/diagnóstico , Várices Esofágicas y Gástricas/etiología , Cirrosis Hepática/complicaciones , Estudios Prospectivos
3.
Endoscopy ; 55(6): 557-562, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36758584

RESUMEN

BACKGROUND : There remain concerns regarding the technical feasibility of endoscopic resection for large gastrointestinal stromal tumors (GISTs), mainly relating to the risk of tumor rupture and the adequacy of the resection margins. This study aimed to evaluate the feasibility and therapeutic outcomes of the newly developed no-touch endoscopic full-thickness resection (NT-EFTR) technique for GISTs. METHODS : In this retrospective study, 92 patients with gastric GISTs undergoing NT-EFTR were included. Clinicopathological, endoscopic, and follow-up data were collected and analyzed. RESULTS : The median tumor size was 2.5 cm and en bloc resection was achieved in all patients with negative surgical margins. The median time of the NT-EFTR procedure was 59.5 minutes. Large tumors (> 3.0 cm), extraluminal tumor growth pattern, and large gastric defects were significant contributors to long operative times. Patients were discharged within 4 days postoperatively. During follow-up, all patients were free from local recurrence and distant metastasis. CONCLUSIONS : NT-EFTR was a feasible method for the resection of gastric GISTs and can be expected to achieve complete radical resection. Large tumors with extraluminal growth and large gastric defects impact procedural difficulty.


Asunto(s)
Resección Endoscópica de la Mucosa , Tumores del Estroma Gastrointestinal , Neoplasias Gástricas , Humanos , Tumores del Estroma Gastrointestinal/cirugía , Tumores del Estroma Gastrointestinal/patología , Estudios Retrospectivos , Resultado del Tratamiento , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Resección Endoscópica de la Mucosa/métodos , Gastroscopía/métodos
4.
World J Gastrointest Surg ; 14(9): 918-929, 2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36185554

RESUMEN

BACKGROUND: Endoscopic resection approaches, including endoscopic submucosal dissection (ESD), submucosal tunneling endoscopic resection (STER) and endoscopic full-thickness resection (EFTR), have been widely used for the treatment of submucosal tumors (SMTs) located in the upper gastrointestinal tract. However, compared to SMTs located in the esophagus or stomach, endoscopic resection of SMTs from the esophagogastric junction (EGJ) is much more difficult because of the sharp angle and narrow lumen of the EGJ. SMTs originating from the muscularis propria (MP) in the EGJ, especially those that grow extraluminally and adhere closely to the serosa, make endoscopic resection even more difficult. AIM: To investigate the predictors of difficult endoscopic resection for SMTs from the MP layer at the EGJ. METHODS: A total of 90 patients with SMTs from the MP layer at the EGJ were included in the present study. The difficulty of endoscopic resection was defined as a long procedure time, failure of en bloc resection and intraoperative bleeding. Clinicopathological, endoscopic and follow-up data were collected and analyzed. Statistical analysis of independent risks for piecemeal resection, long operative time, and intraoperative bleeding were assessed using univariate and multivariate analyses. RESULTS: According to the location and growth pattern of the tumor, 44 patients underwent STER, 14 patients underwent EFTR, and the remaining 32 patients received a standard ESD procedure. The tumor size was 20.0 mm (range 5.0-100.0 mm). Fourty-seven out of 90 lesions (52.2%) were regularly shaped. The overall en bloc resection rate was 84.4%. The operation time was 43 min (range 16-126 min). The intraoperative bleeding rate was 18.9%. There were no adverse events that required therapeutic intervention during or after the procedures. The surgical approach had no significant correlation with en bloc resection, long operative time or intraoperative bleeding. Large tumor size (≥ 30 mm) and irregular tumor shape were independent predictors for piecemeal resection (OR: 7.346, P = 0.032 and OR: 18.004, P = 0.029, respectively), long operative time (≥ 60 min) (OR: 47.330, P = 0.000 and OR: 6.863, P = 0.034, respectively) and intraoperative bleeding (OR: 20.631, P = 0.002 and OR: 19.020, P = 0.021, respectively). CONCLUSION: Endoscopic resection is an effective treatment for SMTs in the MP layer at the EGJ. Tumors with large size and irregular shape were independent predictors for difficult endoscopic resection.

5.
Am J Cancer Res ; 7(6): 1384-1388, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28670498

RESUMEN

Hepatocellular carcinoma (HCC) is a big problem in China where the Hepatitis B (HBV) infection patients are near to 120 million. Early screening and diagnosis is the key to reduce the incidence and mortality of HCC. Serum AFP detection is the main methods for diagnosis, recurrent monitoring and therapeutic evaluation of primary HCC. Hepatitis patients should detect the AFP at least once every six months to help early diagnosis of HCC. Unfortunately, most hepatitis and other liver disease patients do not test their AFP regularly. Therefore, a rapid, convenient detect kit for AFP is necessary for the hepatitis patients to test AFP at home by themselves. It will be very helpful to the HCC early screening and early diagnosis. We screened 859 individuals who were HBsAg positive and had high risk of HCC in Qidong by using two different kits, AFP one-step rapid detection kit (Shanghai Outdo Biotech) and AFP Diagnostics ELISA kit (Zhengzhou Autobio Diagnostics), and compared the results. As a result, the positive accordance rate and the negative accordance rate of AFP one-step rapid detection kit and the Autobio ELISA kit were 95.65% (22/23) and 99.40% (831/836), respectively. The total diagnose accordance rate reached up to 99.30% (853/859). The screening results showed a high accordance rate of two methods. It is so meaningful to achieve home-test and improve HCC early screening and diagnosis by using AFP one-step rapid detection kit.

6.
Int J Clin Exp Med ; 7(5): 1349-54, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24995094

RESUMEN

Unc-51-Like Kinase 1 (ULK1) is regarded as a central role in autophagy. Although the details of how ULK1 triggers autophagy are obscure, the relationship between ULK1 expression and the diagnosis and prognosis of cancer patients may guide the clinical practice and scientific research. The aim of this study was to investigate and compare the expression level of ULK1 in 86 paired esophageal squamous cell carcinoma (ESCC) and paracancerous tissues, and to examine the effect of ULK1 expression on the prognosis of ESCC patients. ULK1 was primarily expressed in cytoplasm, but was rarely seen in nucleus. The levels of cytoplasmic ULK1 in ESCC tissues were higher than those in paracancerous tissue (P < 0.01) and significantly associated with lymph node metastasis (LNM) (P = 0.025). Survival analysis showed that patients with low expression of cytoplasmic ULK1 had worse survival time than those with high expression of cytoplasmic ULK1 (hazard ratio = 1.754, 95% confidence interval: 1.022-3.010, P = 0.041), which disappeared after adjustment for TNM stages and LNM (P = 0.319). In conclusion, ULK1 might play an important role in the occurrence and development of ESCC and represent a potential prognostic biomarker for ESCC patients. However, the precise impact of ULK1 on predicting the prognosis of patients with ESCC requires further investigation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...