Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Cardiovasc Magn Reson ; 16: 58, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-25084814

RESUMEN

BACKGROUND: Many patients with electrical dyssynchrony who undergo cardiac resynchronization therapy (CRT) do not obtain substantial benefit. Assessing mechanical dyssynchrony may improve patient selection. Results from studies using echocardiographic imaging to measure dyssynchrony have ultimately proved disappointing. We sought to evaluate cardiac motion in patients with heart failure and electrical dyssynchrony using cardiovascular magnetic resonance (CMR). We developed a framework for comparing measures of myocardial mechanics and evaluated how well they predicted response to CRT. METHODS: CMR was performed at 1.5 Tesla prior to CRT. Steady-state free precession (SSFP) cine images and complementary modulation of magnetization (CSPAMM) tagged cine images were acquired. Images were processed using a novel framework to extract regional ventricular volume-change, thickening and deformation fields (strain). A systolic dyssynchrony index (SDI) for all parameters within a 16-segment model of the ventricle was computed with high SDI denoting more dyssynchrony. Once identified, the optimal measure was applied to a second patient population to determine its utility as a predictor of CRT response compared to current accepted predictors (QRS duration, LBBB morphology and scar burden). RESULTS: Forty-four patients were recruited in the first phase (91% male, 63.3 ± 14.1 years; 80% NYHA class III) with mean QRSd 154 ± 24 ms. Twenty-one out of 44 (48%) patients showed reverse remodelling (RR) with a decrease in end systolic volume (ESV) ≥ 15% at 6 months. Volume-change SDI was the strongest predictor of RR (PR 5.67; 95% CI 1.95-16.5; P = 0.003). SDI derived from myocardial strain was least predictive. Volume-change SDI was applied as a predictor of RR to a second population of 50 patients (70% male, mean age 68.6 ± 12.2 years, 76% NYHA class III) with mean QRSd 146 ± 21 ms. When compared to QRSd, LBBB morphology and scar burden, volume-change SDI was the only statistically significant predictor of RR in this group. CONCLUSION: A systolic dyssynchrony index derived from volume-change is a highly reproducible measurement that can be derived from routinely acquired SSFP cine images and predicts RR following CRT whilst an SDI of regional strain does not.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Imagen por Resonancia Cinemagnética , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología , Remodelación Ventricular
2.
Med Image Anal ; 17(2): 133-46, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23153619

RESUMEN

An unresolved issue in patients with diastolic dysfunction is that the estimation of myocardial stiffness cannot be decoupled from diastolic residual active tension (AT) because of the impaired ventricular relaxation during diastole. To address this problem, this paper presents a method for estimating diastolic mechanical parameters of the left ventricle (LV) from cine and tagged MRI measurements and LV cavity pressure recordings, separating the passive myocardial constitutive properties and diastolic residual AT. Dynamic C1-continuous meshes are automatically built from the anatomy and deformation captured from dynamic MRI sequences. Diastolic deformation is simulated using a mechanical model that combines passive and active material properties. The problem of non-uniqueness of constitutive parameter estimation using the well known Guccione law is characterized by reformulation of this law. Using this reformulated form, and by constraining the constitutive parameters to be constant across time points during diastole, we separate the effects of passive constitutive properties and the residual AT during diastolic relaxation. Finally, the method is applied to two clinical cases and one control, demonstrating that increased residual AT during diastole provides a potential novel index for delineating healthy and pathological cases.


Asunto(s)
Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Adulto , Anciano , Algoritmos , Módulo de Elasticidad , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico
3.
Eur Heart J Cardiovasc Imaging ; 14(7): 692-9, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23175695

RESUMEN

AIMS: Left ventricular (LV) lead positioning for cardiac resynchronization therapy (CRT) is largely empirical and operator-dependent. Our aim was to determine whether cardiac magnetic resonance (CMR)-guided CRT may improve the acute and the chronic response. METHODS AND RESULTS: CMR-derived anatomical models and dyssynchrony maps were created for 20 patients. The CMR targets (three latest activated segments with <50% scar) were overlaid on to live fluoroscopy. Acute haemodynamic response (AHR) to LV pacing was assessed using an intra-ventricular pressure wire. Chronic CRT response (end-systolic volume reduction ≥15%) was assessed 6 months post-implantation. All patients underwent successful CMR-guided LV lead placement. A CMR target segment was paced in 75% of patients. The mean change in LVdP/dtmax for the CMR target was +14.2 ± 12.5 vs. +18.7 ± 11.9% for the best AHR in any segment and +12.0 ± 13.8% for the segment based on coronary sinus (CS) venography. Using CMR guidance, the acute responder rate was 60 vs. 50% on the basis of venography. At 6 months 60% of patients were echocardiographic responders. Of the echocardiographic responders, 92% were successfully paced in a CMR target segment compared with only 50% of non-responders (P = 0.04). CONCLUSION: CMR guidance compared well when validated against the AHR. Lead placement was possible in the CMR target region in most patients with an AHR comparable with the best achieved in any CS branch. The chronic response was significantly better in patients paced in a CMR target segment. These results suggest that CMR guidance may represent a clinically useful tool for CRT.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/anatomía & histología , Tiempo de Reacción , Remodelación Ventricular/fisiología , Anciano , Angiografía/métodos , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Estudios de Cohortes , Ecocardiografía Doppler en Color , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Humanos , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Marcapaso Artificial , Flebografía/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
4.
Circulation ; 127(1): 39-47, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23183940

RESUMEN

BACKGROUND: Giant cell myocarditis (GCM) typically causes fulminant heart failure, arrhythmias, or heart block, necessitating aggressive immunosuppression, ventricular assist device insertion, or cardiac transplantation. We describe a novel variant of GCM, primarily involving the atria, that displays distinctive clinical features and follows a more benign course than ventricular GCM. METHODS AND RESULTS: We identified 6 patients (median age 67.5 years, 4 male) with atrial GCM in our pathology consultation practices from 2010 to 2012. Clinical history, imaging, and pathology materials were reviewed. Clinically, 4 patients had atrial fibrillation, 1 had acute heart failure, and 1 had incidental disease at autopsy. Among the 5 living patients, echocardiography revealed severe atrial dilatation (5 cases), mitral/tricuspid regurgitation (5), atrial mural thrombus (3), atrial wall thickening (2), and atrial hypokinesis (2). Ventricular function was preserved in all 5. Histological review of surgically resected atria showed giant cell and lymphocytic infiltrates, lymphocytic myocarditis-like foci, cardiomyocyte necrosis, and cardiomyocyte hypertrophy in all cases. Other features included interstitial fibrosis (5), poorly-formed granulomas (4), eosinophils (4), neutrophils (1), and vasculitis (1). Treatment consisted of steroids and cyclosporine (1), pacemaker placement for sick sinus syndrome (1), and supportive care (3). All 5 living patients returned to baseline exercise tolerance after 6 to 16 weeks of follow-up. CONCLUSIONS: Atrial GCM represents a distinct clinicopathologic entity with a more favorable prognosis than classic ventricular GCM. This disorder should be included in the differential diagnosis of atrial dilatation, particularly when associated with atrial wall thickening. The utility of immunomodulatory therapy for this condition remains unknown.


Asunto(s)
Arritmias Cardíacas/patología , Células Gigantes/patología , Insuficiencia Cardíaca/patología , Miocarditis/clasificación , Miocarditis/patología , Miocardio/patología , Adulto , Anciano , Arritmias Cardíacas/etiología , Progresión de la Enfermedad , Femenino , Fibrosis , Atrios Cardíacos/patología , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Miocarditis/complicaciones , Miocitos Cardíacos/patología , Necrosis , Pronóstico
5.
Circ Arrhythm Electrophysiol ; 5(5): 889-97, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22832673

RESUMEN

BACKGROUND: There is considerable heterogeneity in the myocardial substrate of patients undergoing cardiac resynchronization therapy (CRT), in particular in the etiology of heart failure and in the location of conduction block within the heart. This may account for variability in response to CRT. New approaches, including endocardial and multisite left ventricular (LV) stimulation, may improve CRT response. We sought to evaluate these approaches using noncontact mapping to understand the underlying mechanisms. METHODS AND RESULTS: Ten patients (8 men and 2 women; mean [SD] age 63 [12] years; LV ejection fraction 246%; QRS duration 161 [24] ms) fulfilling conventional CRT criteria underwent an electrophysiological study, with assessment of acute hemodynamic response to conventional CRT as well as LV endocardial and multisite pacing. LV activation pattern was assessed using noncontact mapping. LV endocardial pacing gave a superior acute hemodynamic response compared with conventional CRT (26% versus 37% increase in LV dP/dt(max), respectively; P<0.0005). There was a trend toward further incremental benefit from multisite LV stimulation, although this did not reach statistical significance (P=0.08). The majority (71%) of patients with nonischemic heart failure etiology or functional block responded to conventional CRT, whereas those with myocardial scar or absence of functional block often required endocardial or multisite pacing to achieve CRT response. CONCLUSIONS: Endocardial or multisite pacing may be required in certain subsets of patients undergoing CRT. Patients with ischemic cardiomyopathy and those with narrower QRS, in particular, may stand to benefit.


Asunto(s)
Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Técnicas Electrofisiológicas Cardíacas , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Isquemia Miocárdica/fisiopatología , Femenino , Gadolinio DTPA , Hemodinámica , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
Artículo en Inglés | MEDLINE | ID: mdl-23286030

RESUMEN

Patient-specific cardiac modelling can help in understanding pathophysiology and predict therapy planning. However it requires to personalize the model geometry, kinematics, electrophysiology and mechanics. Calibration aims at providing global values (space invariant) of parameters before performing the personalization stage which involves solving an inverse problem to find regional values. We propose an automatic calibration method of the mechanical parameters of the Bestel-Clément-Sorine (BCS) electromechanical model of the heart based on the Unscented Transform algorithm. A sensitivity analysis is performed that reveals which observations on the volume and pressure evolution are significant to characterize the global behaviour of the myocardium. We show that the calibration method gives satisfying results by optimizing up to 7 parameters of the BCS model in only one iteration. This method was evaluated on 7 volunteers and 2 heart failure patients, with a mean relative error from the real data of 11%. This calibration enabled furthermore a preliminary study of the specific parameters to the studied pathologies.


Asunto(s)
Algoritmos , Acoplamiento Excitación-Contracción/fisiología , Sistema de Conducción Cardíaco/fisiología , Modelos Cardiovasculares , Contracción Miocárdica/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Calibración , Simulación por Computador , Circulación Coronaria/fisiología , Humanos
7.
Europace ; 14(3): 373-9, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22045930

RESUMEN

AIMS: Multi-site left ventricular (LV) pacing may be superior to single-site stimulation in correcting dyssynchrony and avoiding areas of myocardial scar. We sought to characterize myocardial scar using cardiac magnetic resonance imaging (CMR). We aimed to quantify the acute haemodynamic response to single-site and multi-site LV stimulation and to relate this to the position of the LV leads in relation to myocardial scar. METHODS: Twenty patients undergoing cardiac resynchronization therapy had implantation of two LV leads. One lead (LV1) was positioned in a postero-lateral vein, the second (LV2) in a separate coronary vein. LV dP/dtmax was recorded using a pressure wire during stimulation at LV1, LV2, and both sites simultaneously (LV1 + 2). Patients were deemed acute responders if ΔLV dP/dtmax was ≥ 10%. Cardiac magnetic resonance imaging was performed to assess dyssynchrony as well as location and burden of scar. Scar anatomy was registered with fluoroscopy to assess LV lead position in relation to scar. RESULTS: LV dP/dtmax increased from 726 ± 161 mmHg/s in intrinsic rhythm to 912 ± 234 mmHg/s with LV1, 837 ± 188 mmHg/s with LV2, and 932 ± 201 mmHg/s with LV1 and LV2. Nine of 19 (47%) were acute responders with LV1 vs. 6/19 (32%) with LV2. Twelve of 19 (63%) were acute responders with simultaneous LV1 + 2. Two of three patients benefitting with multi-site pacing had the LV1 lead positioned in postero-lateral scar. CONCLUSION: Multi-site LV pacing increased acute response by 16% vs. single-site pacing. This was particularly beneficial in patients with postero-lateral scar identified on CMR.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Imagen por Resonancia Magnética , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
8.
Pacing Clin Electrophysiol ; 35(2): 196-203, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22126664

RESUMEN

BACKGROUND: It is not clear whether there is a large difference in acute hemodynamic response (AHR) to left ventricle (LV) pacing in different regions of the same coronary sinus (CS) vein. Using the four electrodes available on a Quartet LV lead, we evaluated the AHR to pacing within individual branches of the CS. METHODS: An acute hemodynamic study was attempted in 20 patients. In each patient, we assessed AHR in a number of CS veins and along a significant proportion of each CS branch using three different bipolar configurations. We compared the AHR achieved when pacing using each different vector and also the highest AHR achieved in any position within the same patient with the lowest achieved in that patient. RESULTS: Sixty-four different CS positions in 19 patients were successfully assessed. No significant difference in AHR was found overall between the three vectors tested. The mean percentage difference in AHR between the CS branch vectors with the lowest and highest dP/dt(max) was +6.5 ± 5.4% (P < 0.001). A much larger difference of +16.9 ± 6.1% (P < 0.001) was seen when comparing the highest and lowest AHR achieved using any vector in any position within the same patient. CONCLUSION: A small difference in AHR is seen when pacing within the same branch of the CS compared to pacing in different branches in the same patient. This suggests that although the site of LV lead placement is important, the position within a CS branch is less important than choosing the right vein.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Circulación Coronaria , Seno Coronario/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Disfunción Ventricular Izquierda/prevención & control , Disfunción Ventricular Izquierda/fisiopatología , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Electrodos Implantados , Femenino , Humanos , Masculino
9.
J Interv Card Electrophysiol ; 33(2): 151-60, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22127378

RESUMEN

PURPOSE: Myocardial scar is an adverse factor when considering which patients are likely to respond to cardiac resynchronisation therapy (CRT). We hypothesized that septal scarring on magnetic resonance imaging (MRI) may be associated with a poor outcome from CRT, which may relate to the inability to place the right ventricular (RV) lead in the septum. METHODS: Fifty patients (ejection fractions, 25 ± 8%; 45 men, 62.8 ± 14 years; 26 dilated cardiomyopathy; and 24 ischaemic cardiomyopathy (ICM)) receiving CRT underwent delayed enhancement cardiac MRI to assess location and burden of myocardial scar. Acute hemodynamic response (AHR) was evaluated at implant with a pressure wire in the left ventricular (LV) cavity. LV remodelling was determined by reduction in LV end-systolic volume at 6 months. RESULTS: The presence of ICM with septal scar was associated with a poor acute and chronic response to CRT. This was predominantly due to a worse response in patients with septal scar. Patients without septal scar had a better AHR with a 26.7 ± 28.9% rise in LV dP/dt (max) from baseline vs. -2.8 ± 14.5% for patients with septal scar (P = 0.01) with Biventricular (BIV) pacing. A greater proportion remodelled (56% vs. 20% (P = 0.02)). Furthermore, only 33% of patients with septal scar had an RV septal lead compared with 66% with no septal scar (P = 0.03). CONCLUSIONS: The presence of septal scar was associated with a poor acute and chronic response to CRT. This may relate to the inability to achieve a RV septal lead placement.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Cicatriz/patología , Tabiques Cardíacos/patología , Imagen por Resonancia Magnética/métodos , Remodelación Ventricular/fisiología , Anciano , Análisis de Varianza , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatía Dilatada/patología , Cardiomiopatía Dilatada/terapia , Cicatriz/terapia , Estudios de Cohortes , Intervalos de Confianza , Ecocardiografía Doppler/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Oportunidad Relativa , Estudios Retrospectivos , Medición de Riesgo , Volumen Sistólico , Resultado del Tratamiento
10.
Europace ; 14(1): 99-106, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21752827

RESUMEN

AIMS: Early inward motion and thickening/thinning of the ventricular septum associated with left bundle branch block is known as the septal flash (SF). Correction of SF corresponds to response to cardiac resynchronization therapy (CRT). We hypothesized that SF was associated with a specific left ventricular (LV) activation pattern predicting a favourable response to CRT. We sought to characterize the spatio-temporal relationship between electrical and mechanical events by directly comparing non-contact mapping (NCM), acute haemodynamics, and echocardiography. METHODS AND RESULTS: Thirteen patients (63 ± 10 years, 10 men) with severe heart failure (ejection fraction 22.8 ± 5.8%) awaiting CRT underwent echocardiography and NCM pre-implant. Presence and extent of SF defined visually and with M-mode was fused with NCM bull's eye plots of endocardial activation patterns. LV-dP/dt(max) was measured during different pacing modes. Five patients had a large SF, four small SF, and four no SF. Large SF patients had areas of conduction block in non-infarcted regions, whereas those with small or no SF did not. Patients with large SF had greater acute response to LV and biventricular (BIV) pacing vs. those with small/no SF (% increase dP/dt 28 ± 14 vs. 11 ± 19% for LV pacing and 42 ± 28 vs. 22 ± 21% for BIV pacing) (P < 0.05). This translated into a more favourable chronic response to CRT. The lines of conduction block disappeared with LV/BIV pacing while remaining with right ventricle pacing. CONCLUSION: A strong association exists between electrical activation and mechanical deformation of the septum. Correction of both mechanical synchrony and the functional conduction block by CRT may explain the favourable response in patients with SF.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Técnicas Electrofisiológicas Cardíacas , Insuficiencia Cardíaca/terapia , Tabiques Cardíacos/fisiopatología , Anciano , Bloqueo de Rama/diagnóstico por imagen , Electrocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Tabiques Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Resultado del Tratamiento , Ultrasonografía
11.
J Am Coll Cardiol ; 58(11): 1128-36, 2011 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-21884950

RESUMEN

OBJECTIVES: We evaluated the relationship between acute hemodynamic response (AHR) and reverse remodeling (RR) in cardiac resynchronization therapy (CRT). BACKGROUND: CRT reduces mortality and morbidity in heart failure patients; however, up to 30% of patients do not derive symptomatic benefit. Higher proportions do not remodel. Multicenter trials have shown echocardiographic techniques are poor at improving response rates. We hypothesized the degree of AHR at implant can predict which patients remodel. METHODS: Thirty-three patients undergoing CRT (21 dilated and 12 ischemic cardiomyopathy) were studied. Left ventricular (LV) volumes were assessed before and after CRT. The AHR (maximum rate of left ventricular pressure [LV-dP/dt(max)]) was assessed at implant with a pressure wire in the LV cavity. Largest percentage rise in LV-dP/dt(max) from baseline (atrial antibradycardia pacing or right ventricular pacing with atrial fibrillation) to dual-chamber pacing (DDD)-LV was used to determine optimal coronary sinus LV lead position. Reverse remodeling was defined as reduction in LV end systolic volume ≥15% at 6 months. RESULTS: The LV-dP/dt(max) increased significantly from baseline (801 ± 194 mm Hg/s to 924 ± 203 mm Hg/s, p < 0.001) with DDD-LV pacing for the optimal LV lead position. The LV end systolic volume decreased from 186 ± 68 ml to 157 ± 68 ml (p < 0.001). Eighteen (56%) patients exhibited RR. There was a significant relationship between percentage rise in LV-dP/dt(max) and RR for DDD-LV pacing (p < 0.001). A similar relationship for AHR and RR in dilated cardiomyopathy and ischemic cardiomyopathy (p = 0.01 and p = 0.006) was seen. CONCLUSIONS: Acute hemodynamic response to LV pacing is useful for predicting which patients are likely to remodel in response to CRT both for dilated cardiomyopathy and ischemic cardiomyopathy. Using AHR has the potential to guide LV lead positioning and improve response rates.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis/métodos , Presión Ventricular , Remodelación Ventricular , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Cardiomiopatía Dilatada/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
13.
Europace ; 13(7): 992-6, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21343237

RESUMEN

AIMS: Problems with implanting a left ventricular (LV) lead during cardiac resynchronization therapy (CRT) procedures are not uncommon and may occur for a variety of reasons including phrenic nerve stimulation (PNS) and high capture thresholds. We aimed to perform successful CRT in patients with previous LV lead problems using the multiple pacing configurations available with the St Jude Quartet model 1458Q quadripolar LV lead to overcome PNS or high capture thresholds. METHODS AND RESULTS: Four patients with previous failed attempts at LV lead implantation underwent a further attempt at CRT using a Quartet lead. In all four cases, successful CRT was achieved using a Quartet lead placed in a branch of the coronary sinus. Problems with PNS or high capture thresholds were seen in all four patients but were successfully overcome. Satisfactory lead parameters were seen at implant, pre-discharge, and at short-term follow-up (8.5±5 weeks). CONCLUSION: The Quartet lead allows 10 different pacing vectors to be used and may overcome common pacing problems because of the multiple pacing configurations available. Problems with either PNS or unsatisfactory pacing parameters experienced during CRT may be resolved simply by changing the pacing configuration using this quadripolar lead system.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Ventrículos Cardíacos/fisiopatología , Adulto , Anciano , Seno Coronario/fisiopatología , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nervio Frénico/fisiopatología , Insuficiencia del Tratamiento , Resultado del Tratamiento
14.
Circ Heart Fail ; 4(2): 170-9, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21216832

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) using endocardial left ventricular (LV) pacing may be superior to conventional CRT. We studied the acute hemodynamic response to conventional CRT and LV pacing from different endocardial sites using a combined cardiac MRI and LV noncontact mapping (NCM) protocol to gain insights into the underlying mechanisms. METHODS AND RESULTS: Fifteen patients (age, 63 ± 10 years; 12 men) awaiting CRT were studied in a combined x-ray and MRI laboratory. Delayed-enhancement cardiac magnetic resonance was performed to define areas of myocardial fibrosis. Patients underwent an electrophysiological study incorporating endocardial and epicardial LV pacing. Acute hemodynamic response was measured using a pressure wire within the LV cavity to derive LV dP/dt max. NCM was used to define areas of slow conduction. There was a significant improvement in all LV pacing modes versus baseline (P<0.001). LV endocardial CRT from the best endocardial site was superior to conventional CRT, with a 79.8 ± 49.0% versus 59.6 ± 49.5% increase in LV dP/dt max of from baseline (P<0.05). The hemodynamic benefits of pacing were greater when LV stimulation was performed outside of areas of slow conduction defined by NCM (P<0.001). Delayed-enhancement cardiac magnetic resonance was able to delineate zones of slow conduction seen with NCM in ischemic patients but was unreliable in nonischemic patients. CONCLUSIONS: Endocardial LV pacing appears superior to conventional CRT, although the optimal site varies between subjects and is influenced by pacing within areas of slow conduction. Delayed-enhancement cardiac magnetic resonance was a poor predictor of zones of slow conduction in nonischemic patients.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Técnicas Electrofisiológicas Cardíacas , Endocardio/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Imagen por Resonancia Magnética , Pericardio/fisiopatología , Anciano , Análisis de Varianza , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Londres , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Presión Ventricular , Rayos X
15.
Pacing Clin Electrophysiol ; 34(4): 484-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21208241

RESUMEN

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients. RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead. CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Electrodos Implantados , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Resultado del Tratamiento
16.
Pacing Clin Electrophysiol ; 34(2): 226-34, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21029135

RESUMEN

BACKGROUND: Failure rate for left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is up to 12%. The use of segmentation tools, advanced image registration software, and high-fidelity images from computerized tomography (CT) and cardiac magnetic resonance (CMR) of the coronary sinus (CS) can guide LV lead implantation. We evaluated the feasibility of advanced image registration onto live fluoroscopic images to allow successful LV lead placement. METHODS: Twelve patients (11 male, 59 ± 16.8 years) undergoing CRT had three-dimensional (3D) whole-heart imaging (six CT, six CMR). Eight patients had at least one previously failed LV lead implant. Using segmentation software, anatomical models of the cardiac chambers, CS, and its branches were overlaid onto the live fluoroscopy using a prototype version of the Philips EP Navigator software to guide lead implantation. RESULTS: We achieved high-fidelity segmentations of cardiac chambers, coronary vein anatomy, and accurate registration between the 3D anatomical models and the live fluoroscopy in all 12 patients confirmed by balloon occlusion angiography. The CS was cannulated successfully in every patient and in 11, an LV lead was implanted successfully. (One patient had no acceptable lead values due to extensive myocardial scar). CONCLUSION: Using overlaid 3D segmentations of the CS and cardiac chambers, it is feasible to guide CRT implantation in real time by fusing advanced imaging and fluoroscopy. This enabled successful CRT in a group of patients with previously failed implants. This technology has the potential to facilitate CRT and improve implant success.


Asunto(s)
Terapia de Resincronización Cardíaca , Seno Coronario/diagnóstico por imagen , Seno Coronario/patología , Electrodos Implantados , Ventrículos Cardíacos/cirugía , Imagen por Resonancia Cinemagnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Masculino , Implantación de Prótesis/métodos , Cirugía Asistida por Computador
18.
J Magn Reson Imaging ; 33(1): 87-95, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21182125

RESUMEN

PURPOSE: To evaluate a cardiac MR (CMR) examination with slow infusion of a high-relaxivity contrast agent to visualize coronary venous anatomy (CVA) and myocardial scar in heart failure patients awaiting cardiac resynchronization therapy (CRT). MATERIALS AND METHODS: Fourteen patients awaiting CRT (seven ischemic cardiomyopathy (ICM) and seven non-ICM) and two with normal LV function underwent CMR on a 1.5 Tesla (T) MR scanner. Dimeglumine-gadobenate was slowly infused. Bolus arrival in the LV was measured by a dynamic electrocardiogram (ECG) -triggered inversion recovery (IR) scan subsequent to starting an ECG-triggered respiratory-navigated three-dimensional (3D) SSFP MR scan with IR preparation to acquire systolic whole-heart anatomy for vein visualization. Delayed contrast-enhanced MR scan was performed to assess myocardial scar. CVA obtained by CMR was compared with X-ray venography in 11 patients. CVA and scar were segmented and registered for visual inspection. RESULTS: For all subjects, there was excellent visualization of the CVA. All ICM and one non-ICM patient showed scar. There was excellent correlation between veins seen by CMR and venography. CONCLUSION: We have demonstrated that slow infusion protocol of dimeglumine-gadobenate can be used to assess both CVA and myocardial scar in a single MR examination. Furthermore, an image overlay technique has been used to show the relationship of scar to the CVA.


Asunto(s)
Cardiomiopatías/patología , Cicatriz/patología , Anomalías de los Vasos Coronarios/patología , Gadolinio DTPA , Imagen por Resonancia Cinemagnética/métodos , Venas/anomalías , Venas/patología , Terapia de Resincronización Cardíaca , Medios de Contraste/administración & dosificación , Vasos Coronarios , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Aumento de la Imagen/métodos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Selección de Paciente , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Int J Cardiol ; 138(1): e4-5, 2010 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-18692257

RESUMEN

The population of haemodialysis patients is increasing as is their age. There is a higher risk of cardiac comorbidities in these patients. Pacing is increasingly common in this group. We present a case highlighting the difficult issues and exemplifies the need for careful planning preprocedure. Haemodialysis patients often have difficult and limited vascular access. Insertion of pacing leads is associated with subclavian vein stenosis. If this is on the side of an AV fistula there is significant risk of losing the fistula with obvious consequences to the patient. Careful consideration of site and route of access needs to be made prior to pacing. The need for involvement of renal and vascular teams before starting the procedure is essential as it is paramount that the best route of access for pacing wires is selected.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Estimulación Cardíaca Artificial/métodos , Bloqueo Cardíaco/terapia , Fallo Renal Crónico/terapia , Diálisis Renal , Anciano , Venas Braquiocefálicas , Bloqueo Cardíaco/complicaciones , Humanos , Fallo Renal Crónico/complicaciones , Masculino , Marcapaso Artificial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...