1.
J Arthroplasty ; 37(8): 1658-1666, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35346808

RESUMEN

BACKGROUND: To date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for clinical and functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether minimally invasive approaches are superior to conventional approaches for clinical outcomes. METHODS: All studies comparing MI approaches to conventional approaches were eligible for analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: 'minimally invasive', 'muscle-sparing', 'THA', 'THR', 'hip arthroplasty' and 'hip replacement'. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the European Union (EU) clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation). RESULTS: Twenty studies were identified. There were 1,282 MI total hip arthroplasty (THAs) and 1,351 conventional THAs performed. There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (P = .959), aseptic revision (P = .894), instability (P = .894), infection (P = .669) and periprosthetic fracture (P = .940). There was also no difference in functional outcome at early or intermediate follow-up between the two groups (P = .38). In level I studies exclusively, random-effects meta-analysis demonstrated no difference in aseptic revision (P = .461) and all other outcomes between both groups. CONCLUSION: Intermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Sistema de Registros , Reoperación
2.
Acta Biomater ; 131: 581-594, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34192572

RESUMEN

Adverse local tissue reactions (ALTRs) are a prominent cause of hip implant failure. ALTRs are characterized by aseptic necrosis and leukocyte infiltration of synovial tissue. The prevalence of ALTRs in hips with failing metal implants, with highest rates occurring in patients with metal-on-metal articulations, suggests a role for CoCrMo corrosion in ALTR formation. Although hypersensitivity reactions are the most accepted etiology, the precise cellular mechanism driving ALTR pathogenesis remains enigmatic. Here we show that cobalt ions released by failing hip implants induce mitochondrial stress and cytokine secretion by synovial fibroblasts: the presumptive initiators of ALTR pathogenesis. We found that in-vitro treatment of synovial fibroblasts with cobalt, but not chromium, generated gene expression changes indicative of hypoxia and mitophagy responses also observed in ALTRs biopsies. Inflammatory factors secreted by cobalt-exposed synovial fibroblasts were among those most concentrated in ALTR synovial fluid. Furthermore, both conditioned media from cobalt-exposed synovial fibroblasts, and synovial fluid from ALTRs patients, elicit endothelial activation and monocyte migration. Finally, we identify the IL16/CTACK ratio in synovial fluid as a possible diagnostic marker of ALTRs. Our results provide evidence suggesting that metal ions induce cell stress in synovial fibroblasts that promote an inflammatory response consistent with initiating ALTR formation. STATEMENT OF SIGNIFICANCE: We demonstrate that the cytotoxic effects of cobalt ions on the synovial cells (fibroblast) is sufficient to trigger inflammation on hip joints with metal implants. Cobalt ions affect mitochondrial function, leading to the auto phagocytosis of mitochondria and trigger a hypoxic response. The cell's hypoxic response includes secretion of cytokines that are capable of trigger inflammation by activating blood vessels and enhancing leukocyte migration. Among the secreted cytokines is IL-16, which is highly concentrated in the synovial fluid of the patients with adverse local tissue reactions and could be use as diagnostic marker. In conclusion we define the cells of the hip joint as key players in triggering the adverse reactions to hip implants and providing biomarkers for early diagnosis of adverse reactions to hip implants.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Quimiocinas , Cromo , Cobalto/toxicidad , Citocinas , Fibroblastos , Prótesis de Cadera/efectos adversos , Humanos , Iones , Diseño de Prótesis , Falla de Prótesis , Estrés Fisiológico
3.
J Orthop Res ; 39(12): 2581-2594, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33506972

RESUMEN

Hip implants are a successful solution for osteoarthritis; however, some individuals with metal-on-metal (MoM) and metal-on-polyethylene (MoP) prosthetics develop adverse local tissue reactions (ALTRs). While MoM and MoP ALTRs are presumed to be delayed hypersensitivity reactions to corrosion products, MoM- and MoP-associated ALTRs present with different histological characteristics. We compared MoM- and MoP-associated ALTRs histopathology with cobalt and chromium levels in serum and synovial fluid. We analyzed the gene expression levels of leukocyte aggregates and synovial fluid chemokines/cytokines to resolve potential pathophysiologic differences. In addition, we classified ALTRs from 79 patients according to their leukocyte infiltrates as macrophage-dominant, mixed, and lymphocyte-dominant. Immune-related transcript profiles from lymphocyte-dominant MoM- and MoP-associated ALTR patients with perivascular lymphocytic aggregates were similar. Cell signatures indicated predominantly macrophage, Th1 and Th2 lymphocytic infiltrate, with strong exhausted CD8+ signature, and low Th17 and B cell, relative to healthy lymph nodes. Lymphocyte-dominant ALTR-associated synovial fluid contained higher levels of induced protein 10 (IP-10), interleukin-1 receptor antagonist (IL-1RN), IL-8, IL-6, IL-16, macrophage inflammatory protein 1 (MIP-1α), IL-18, MCP-2, and lower cell-attracting chemokine levels, when compared with prosthetic revisions lacking ALTRs. In addition, the higher levels of IP-10, IL-8, IL-6, MIP-1α, and MCP-2 were observed within the synovial fluid of the lymphocyte-dominant ALTRs relative to the macrophage-dominant ALTRs. Not all cytokines/chemokines were detected in the perivascular aggregate transcripts, suggesting the existence of other sources in the affected synovia. Our results support the hypothesis of common hypersensitivity pathogenesis in lymphocyte-dominant MoM and MoP ALTRs. The exhausted lymphocyte signature indicates chronic processes and an impaired immune response, although the cause of the persistent T-cell activation remains unclear. The cytokine/chemokine signature of lymphocyte-dominant-associated ATLRs may be of utility for diagnosing this more aggressive pathogenesis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Artroplastia de Reemplazo de Cadera/efectos adversos , Linfocitos T CD8-positivos , Quimiocina CCL3 , Quimiocina CXCL10 , Prótesis de Cadera/efectos adversos , Humanos , Interleucina-6 , Interleucina-8 , Linfocitos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales , Polietileno , Diseño de Prótesis , Falla de Prótesis , Reoperación
4.
Hip Int ; 31(5): 637-643, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32390475

RESUMEN

BACKGROUND: The early outcomes of large head-metal-on-metal total hip arthroplasty (MoM THA) are compromised by adverse local tissue reaction to metal debris. This study is the mid-term follow-up of a prospective randomised control trial (pRCT) comparing MoM THA to MoM HR. We sought to answer whether there was a difference between MoM THA and MoM HR at mid-term follow-up in the implant survival; patient-reported outcome measures (PROMs); and when performing objective functional tasks? METHODS: A total of 104 patients were studied. Of these 56 had MoM THA (50 male) and 48 had HR (43 male). Mean age at surgery was 52 years in both groups.We reviewed this cohort at mid-term follow-up [minimum 8 years (mean 9 years; range 8-10; SD 0.7)]. PROMs that were completed were OHS, WOMAC, SF-12, and the UCLA. For objective functional task-based outcomes, gait parameters for operated legs were assessed in a subgroup of 17 patients with high UCLA. RESULTS: Revision rate in MoM THA group was 7/56 (12.5%) and in the HR group was 1/48 (2.1%). Overall revision rate at minimum 8-year follow-up was 7.7% (8 of 104 patients). PROMs data comparing MoM THA versus HR showed no difference between the groups. 4 (8.5%) of the non-revised (47) HR patients had WOMAC function or pain score below 70. 3 (6.4%) patients had both pain and function scores <70. In the THA group, 5 (10.2%) of the non-revised (49) patients had WOMAC pain or function scores <70. 3 (6.1%) patients had both pain and function scores <70. The comparison of HA versus THA showed several gait parameters in the HR group to be better but not statistically significant (p > 0.05 Mann-Whitney U-test). CONCLUSIONS: At mid-term follow-up, the revision rate of MoM articulation for THA is high (7.7%), being higher in large head MoM total hips versus resurfacing. Overall probability of 10-year survival is 92.3% (KM analysis, 95% for MoM THA and 98% for HR). The HR group had better functional parameters on gait-based tasks compared to THA group but this difference did not reach statistical significance.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Diseño de Prótesis , Reoperación , Resultado del Tratamiento
5.
BMC Biomed Eng ; 2: 7, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32903342

RESUMEN

Tourniquets in orthopaedic surgery safely provide blood free surgical fields, but their use is not without risk. Tourniquets can result in temporary or permanent injury to underlying nerves, muscles, blood vessels and soft tissues. Advances in safety, accuracy and reliability of surgical tourniquet systems have reduced nerve-related injuries by reducing pressure levels and pressure gradients, but that may have resulted in reduced awareness of potential injury mechanisms. Short-term use of pre-hospital tourniquets is effective in preventing life-threatening blood loss, but a better understanding of the differences between tourniquets designed for pre-hospital vs surgical use will provide a framework around which to develop guidelines for admitting to hospital individuals with pre-applied tourniquets. Recent evidence supports the application of tourniquets for blood flow restriction (BFR) therapy to reduce muscular atrophy, increase muscle strength, and stimulate bone growth. BFR therapy when appropriately prescribed can augment a surgeon's treatment plan, improving patient outcomes and reducing recovery time. Key risks, hazards, and mechanisms of injury for surgical, BFR therapy, and pre-hospital tourniquet use are identified, and a description is given of how advances in personalized tourniquet systems have reduced tourniquet-related injuries in these broader settings, increasing patient safety and how these advances are improving treatment outcomes.

6.
Bone Joint J ; 102-B(7_Supple_B): 112-115, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32600199

RESUMEN

AIMS: The practice of overlapping surgery has been increasing in the delivery of orthopaedic surgery, aiming to provide efficient, high-quality care. However, there are concerns about the safety of this practice. The purpose of this study was to examine the safety and efficacy of a model of partially overlapping surgery that we termed 'swing room' in the practice of primary total hip (THA) and knee arthroplasty (TKA). METHODS: A retrospective review of prospectively collected data was carried out on patients who underwent primary THA and TKA between 2006 and 2017 in two academic centres. Cases were stratified as partially overlapping (swing room), in which the surgeon is in one operating room (OR) while the next patient is being prepared in another, or nonoverlapping surgery. The demographic details of the patients which were collected included operating time, length of stay (LOS), postoperative complications within six weeks of the procedure, unplanned hospital readmissions, and unplanned reoperations. Fisher's exact, Wilcoxon rank-sum tests, chi-squared tests, and logistic regression analysis were used for statistical analysis. RESULTS: A total of 12,225 cases performed at our institution were included in the study, of which 10,596 (86.6%) were partially overlapping (swing room) and 1,629 (13.3%) were nonoverlapping. There was no significant difference in the mean age, sex, body mass index (BMI), side, and LOS between the two groups. The mean operating time was significantly shorter in the swing room group (58.2 minutes) compared with the nonoverlapping group (62.8 minutes; p < 0.001). There was no significant difference in the rates of complications, readmission and reoperations (p = 0.801 and p = 0.300, respectively) after adjusting for baseline American Society of Anesthesiologists scores. CONCLUSION: The new 'swing room' model yields similar short-term outcomes without an increase in complication rates compared with routine single OR surgery in patients undergoing primary THA or TKA. Cite this article: Bone Joint J 2020;102-B(7 Supple B):112-115.


Asunto(s)
Citas y Horarios , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Quirófanos/organización & administración , Seguridad del Paciente , Canadá , Femenino , Hospitales de Alto Volumen , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tempo Operativo , Readmisión del Paciente/estadística & datos numéricos , Estudios Retrospectivos
7.
World J Orthop ; 11(2): 82-89, 2020 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-32190552

RESUMEN

The demand for revision total hip arthroplasty (THA) is increasing. Information quality on the internet has been extensively analysed in relation to primary THA but no such analysis has ever been performed for revision THA. Our aim was to assess the quality and readability of this information. Three major internet search engines were searched for information on revision THA. All websites were assessed for quality of information using the DISCERN score, the Journal of the American Medical Association benchmark criteria and a novel scoring system specific to revision THA [Vancouver Revision Arthroplasty Information (VRAI) score]. Website readability was assessed, as was presence of the Health On the Net Foundation (HON) seal. The majority of websites (52%) were academic with a post-graduate reading level. Only 6.5% of websites had the HON seal. Twenty-eight percent of websites had a 'good' DISCERN score and only 28% had a 'good' score with the novel VRAI scoring system. Health information websites had significantly higher rates of 'good' VRAI scores (P = 0.008). Websites with the HON seal had significantly higher DISCERN scores (P = 0.01). All governmental websites were at a reading level suitable for patient review. Information on the internet relating to revision THA is of low quality, much lower than the quality of information on primary THA. We recommend governmental websites for their readability and health information websites for their quality of information specific to revision THA. Websites with the HON seal provide higher quality information and should be recommended to patients as reading material regarding revision THA.

8.
Hip Int ; 30(1): 93-100, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30887851

RESUMEN

BACKGROUND: The treatment for recurrent dislocation of a total hip arthroplasty is surgical using varied techniques and technologies to reduce the chances of re-dislocation and re-revision. The goal of this study is to compare operative techniques to reduce re-dislocation and re-revision in revision hip arthroplasty due to recurrent dislocations. METHODS: A retrospective study of revision hip arthroplasties done due to recurrent dislocation prior to 01 January 2014. Electronic physician and provincial health records were used to collect patients' initial and follow-up data. Treatment failure was defined as either aseptic re-revision or re-dislocation without revision. Time to event was considered as the re-revision date or the date of second dislocation when the latter endpoint was used. RESULTS: Of 379 operations, 88 (23.2%) had aseptic repeat revision or recurrent dislocation. Of these: 66 (75.0%) due to dislocation with re-revision; 10 (11.4%) due to dislocation with no re-revision surgery; 5 (5.7%) due to aseptic loosening of components; 3 (3.4%) due to osteolysis; 3 (3.4%) due to pseudotumour; and 1 (1.1%) due to periprosthetic fracture. The following factors increase risk of failure: the use of augmented-liners (lipped, oblique and high-offset liners; HR = 1.68, 95% CI, 1.05-2.69), periprosthetic femur fracture (HR = 2.80, 95% CI, 1.39-8.21) and pelvic discontinuity (HR = 3.69, 95% CI, 1.66-8.21). Femur head sizes 36-40 mm are protective (HR = 0.54, 95% CI, 0.31-0.86). In abductor dysfunction the use of focal constrained liners decreases the risk of failure (HR = 0.13, 95% CI, 0.018-0.973). CONCLUSIONS: Larger head sizes and focal constrained liners (abductors dysfunction) should be used and fully constrained liners and augmented-liners should be avoided in a revision hip arthroplasty due to recurrent dislocations.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Luxación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/cirugía , Anciano , Femenino , Luxación de la Cadera/etiología , Humanos , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/complicaciones , Reoperación , Estudios Retrospectivos , Factores de Riesgo
9.
Orthopedics ; 42(1): 34-40, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30658002

RESUMEN

Two-stage exchange arthroplasty remains the treatment of choice for chronic periprosthetic joint infections. This retrospective study conducted between 2009 and 2015 examined the diagnostic value of biomarkers for residual infection between stages. The biomarkers evaluated included C-reactive protein prior to reimplantation, preimplantation synovial fluid white blood cell count and percent neutrophils, and the intraoperative histologic synovial white blood cell count per high-power field (×400) on permanent sections. Residual infection was defined as either positive cultures (more than 1) at second stage, any further surgery (eg, amputation, arthrodesis, or another 2-stage revision), or the need for infection suppression with antibiotics. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated accordingly. A total of 182 two-stage exchange operations that included 109 (59.9%) prosthetic hips and 73 (40.1%) prosthetic knees met the inclusion criteria. Residual infection was present in 38 (20.9%) of the procedures. The area under the curve-receiver operating characteristic values were 0.677 for C-reactive protein (P=.002), 0.506 for aspiration white blood cell count (P=.944), 0.623 for aspiration percent neutrophils (P=.200), and 0.524 for white blood cell count per high-power field (P=.801). Positive and negative predictive values were poor and ranged between 26% and 57% and 78% and 85%, respectively. Analyses using specific combinations of biomarkers did not significantly improve predictive values. This study showed that classic markers perform poorly in identifying residual infection prior to second-stage revision. Further research is necessary to evaluate the diagnostic utility of other, more recently introduced biomarkers to determine whether infection has been eradicated between stages. [Orthopedics. 2019; 42(1):34-40.].


Asunto(s)
Proteína C-Reactiva/análisis , Recuento de Leucocitos , Neutrófilos/metabolismo , Infecciones Relacionadas con Prótesis/diagnóstico , Líquido Sinovial/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Biomarcadores/metabolismo , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
J Arthroplasty ; 33(9): 2961-2966, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29807791

RESUMEN

BACKGROUND: Instability remains one of the main problems after revision hip surgery. The aim of this study was to review the clinical, radiological, and patient-reported outcomes with the use of modular dual-mobility articulation for revision acetabular reconstruction and investigate the risk of fretting corrosion by measuring serum trace metal ion levels. METHODS: Sixty consecutive patients with a minimum of 24-month follow-up after the insertion of a modular dual-mobility (Stryker, Mahwah, NJ) cup at the time of revision hip surgery were identified. Follow-up included clinical and radiological patient review and functional outcome measures, and a subset of patients had their metal ion (cobalt and chromium) levels checked. RESULTS: At the most recent follow-up, 5 patients had died, 3 patients have been revised because of ongoing instability, and 3 patients have had revision surgery due to infection. Overall functional outcome (mean Western Ontario and McMaster Universities Osteoarthritis Indexfunction 76, University of California, Los Angeles 5.6, mean Oxford 74.7, Short Form-12 physical 41.6/mental 53.3) and overall pain relief (mean Western Ontario and McMaster Universities Osteoarthritis Index pain score 78.3) scores were good. The mean satisfaction score was 78 of 100. The median serum trace metal chromium and cobalt levels at the most recent follow-up were 0.4 µg/L (range 0.1-6.1 µg/L) and 0.42 µg/L (range 0.21-9.42 µg/L), respectively. The survival with revision as the end point was 90%. CONCLUSIONS: Dual-mobility cups with modularity represent an excellent option for the patient having revision hip surgery at high risk of instability. This series presents good patient-reported outcome measures and a low complication and revision rate.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Reoperación/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Cromo/sangre , Cobalto/sangre , Corrosión , Femenino , Estudios de Seguimiento , Humanos , Iones/sangre , Estudios Longitudinales , Masculino , Metales/sangre , Persona de Mediana Edad , Osteoartritis/diagnóstico , Osteoartritis/cirugía , Diseño de Prótesis , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
Clin Orthop Relat Res ; 476(2): 230-241, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29529651

RESUMEN

BACKGROUND: Once touted as the future of hip arthroplasty, metal-on-metal (MoM) bearing surfaces have fallen sharply from favor with the emergence of a strong body of evidence demonstrating unacceptably high premature implant failure rates. The previously unpredictable development of adverse local tissue reactions (ALTRs) has been a substantive contributor to this. Although the underlying pathophysiology of these so-called "pseudotumors" is now well understood, the fundamental predisposing patient risk factors have remained elusive. QUESTIONS/PURPOSES: The aim of this research, as a clinical-genotype correlation analysis, was to identify specific alleles (genes) associated with the development of ALTRs in patients with in situ MoM THAs. METHODS: A case-control study of patients who received a large-head, primary MoM THA between 2005 and 2008 was performed with a minimum followup of 5 years. Twenty-six patients who had undergone revision of a primary MoM THA secondary to symptomatic ALTRs were recruited. The mean timeframe from primary MoM THA to symptomatic revision was 5.5 years (range, 1-10 years). Twenty-eight control subjects were randomly selected asymptomatic patients with no evidence of ALTRs on protocol-specific screening. Baseline demographics and high-resolution genotype (human leukocyte antigen [HLA] Class II) were collected for all patients. Cohorts were similar with respect to age at the time of primary MoM THA (mean, 54.8 versus 54.9 years, p = 0.95) and serum cobalt (mean, 5.5 versus 8.5 µg/L, p = 0.09) and chromium concentrations (mean, 2.9 versus 4.2 µg/L, p = 0.27). The association between genotype and revision surgery secondary to ALTRs was determined with gender as a covariate. RESULTS: The prevalence of the risk genotype was 30% (16 of 54) among the entire cohort. Adjusting for sex, the odds of revision were 6.1 times greater among patients with the risk genotype present than among patients without (95% confidence interval [CI], 1.5-25.4; p = 0.01). Among females, the specificity of the risk genotype was 1.0 (95% CIexact, 0.5-1.0; pexact = 0.03), and for males, it was 0.8 (95% CIexact, 0.6-0.9; pexact < 0.01). CONCLUSIONS: The findings of this study suggest that, among patients with a primary MoM THA, allelic variation within the HLA Class II loci may be a strong, independent risk factor associated with the need for subsequent revision surgery secondary to pseudotumor formation. CLINICAL RELEVANCE: Given the hypothesis-generating nature of this novel undertaking, confirmatory prospective clinical studies are required to further elucidate this correlation and to explore the clinical utility of targeted genetic screening in this specific population. This research may, however, represent a key missing piece in the puzzle that is metal ion-induced pseudotumor formation.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Granuloma de Células Plasmáticas/genética , Articulación de la Cadera/cirugía , Prótesis de Cadera , Antígenos de Histocompatibilidad Clase II/genética , Prótesis Articulares de Metal sobre Metal , Falla de Prótesis , Anciano , Colombia Británica/epidemiología , Estudios de Casos y Controles , Femenino , Frecuencia de los Genes , Estudios de Asociación Genética , Predisposición Genética a la Enfermedad , Granuloma de Células Plasmáticas/epidemiología , Granuloma de Células Plasmáticas/inmunología , Granuloma de Células Plasmáticas/cirugía , Articulación de la Cadera/fisiopatología , Antígenos de Histocompatibilidad Clase II/inmunología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Diseño de Prótesis , Reoperación , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Hip Int ; 27(5): 509-513, 2017 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-28165588

RESUMEN

INTRODUCTION: The aim of this study was to review the clinical, radiological and patient-reported outcomes with the use of cup-cage construct for pelvic discontinuity at our institution. METHODS: 24 patients were identified at median 6-year (minimum 2 year, maximum 10 years) follow-up. 1 patient was converted to excision arthroplasty for infection. A further 3 patients required revision for instability but the cup-cage construct was not revised. RESULTS: We noted encouraging pain relief (mean WOMAC pain 85.6) and good functional outcome (mean WOMAC function 78.2, mean UCLA 5, mean OHS 78.6). Patient satisfaction with regards pain relief, function and return to recreational activities were noted to be good. CONCLUSIONS: The cup-cage construct is a viable method of dealing with complex pelvic discontinuity. However, the failure rate due to loosening (4 cases) in this and other reports does prompt the need for further refinement of the technique and technology in this very challenging group of patients, as well as continued evaluation at the mid- and long-term so as to confirm the ongoing success of this method of reconstruction.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Predicción , Articulación de la Cadera/cirugía , Prótesis de Cadera , Artropatías/cirugía , Satisfacción del Paciente , Huesos Pélvicos/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Falla de Prótesis , Reoperación , Estudios Retrospectivos
13.
Clin Orthop Relat Res ; 475(2): 433-441, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27444034

RESUMEN

BACKGROUND: The risk of early revision because of pseudotumors in patients who have undergone large-head metal-on-metal (MoM) total hip arthroplasty (THA) is well documented. However, the natural history of asymptomatic pseudotumors or of MoM articulations without pseudotumors is less well understood. The aim of our study was to investigate the natural history of primary MoM THA at mid-term followup. QUESTIONS/PURPOSES: The purposes of this study were: (1) Did previously detected pseudotumors persist or worsen in asymptomatic patients at mid-term followup; and if so, did any of them require revision THA? (2) Did new pseudotumors form in asymptomatic patients at mid-term followup? (3) What happened to serum trace metal ions at mid-term followup? (4) Were postoperative patient-reported outcome measures (PROMs) maintained at mid-term followup? METHODS: Seventy-one patients who underwent a MoM THA using a Metasul LDH implant with a Durom acetabular cup and an M/L Taper stem between September 2005 and October 2008 were reviewed. All patients for this study were part of two previously published studies from our early followup. Data from the previous studies were used for comparison only. Two of the 71 patients (2.8%) were lost to followup. The mean age at operation was 56 years (range, 34-68 years). There were 24 female patients. All patients had serum trace metal ions testing, ultrasound imaging, and PROMs at a mean 3.5 years (early followup) after the index operation (range, 3-5 years) and delayed followup at a mean 7 years (range, 6.5-9 years). The indication to undertake revision THA was based on clinical evaluation and not solely on the investigation results. RESULTS: Twenty-three of 71 patients (32%) had a positive ultrasound scan for pseudotumor at early followup. Of these, eight patients underwent revision THA (11% of MoM THA or 35% of patients with an early positive ultrasound scan). The mean time between positive ultrasound scan and revision surgery was 13 months (range, 5-22 months). Of the remaining 15 patients with pseudotumor noted on early ultrasound, 12 had persistent pseudotumor, two resolved, and one was lost to followup. Six patients (13%) with a normal ultrasound scan at early followup showed new ultrasound findings at delayed followup. Of these, four (8%) were conclusively diagnosed as pseudotumor and one was revised. Serum trace metal ion increased at mid-term followup in the seven cases that showed an increase in volume of pseudotumor. Of the five patients in whom the volume of pseudotumor decreased on ultrasound at mid-term followup, three showed a decrease in serum trace ions levels, whereas two showed an increase. New-onset pseudotumors at mid-term followup was associated with an increase in serum trace metal ions at mid-term followup only in two of six cases. PROMs at mid-term followup of patients in this study remain high. CONCLUSIONS: At mid-term followup, approximately 35% of patients who develop an early pseudotumor undergo revision arthroplasty, whereas the remaining are asymptomatic. The incidence of new-onset ultrasound findings suggestive of pseudotumors at mid- to long-term followup is approximately 8% and these require continued surveillance. LEVEL OF EVIDENCE: Level II, prognostic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Granuloma de Células Plasmáticas/etiología , Prótesis de Cadera/efectos adversos , Artropatías/etiología , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Anciano , Progresión de la Enfermedad , Femenino , Granuloma de Células Plasmáticas/patología , Humanos , Artropatías/patología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación , Factores de Riesgo , Resultado del Tratamiento
14.
Clin Orthop Relat Res ; 475(1): 186-192, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27672012

RESUMEN

BACKGROUND: The ideal femoral component for revision THA is undecided. Cylindrical nonmodular stems have been associated with stress shielding, whereas junctional fractures have been reported with tapered fluted modular titanium stems. We have used a tapered fluted nonmodular titanium femoral component (Wagner Self-locking [SL] femoral stem) to mitigate this risk. This component has been used extensively in Europe by its designer surgeons, but to our knowledge, it has not been studied in North America. Added to this, the design of the component has changed since early reports. QUESTIONS/PURPOSES: We asked: (1) Does the Wagner SL stem have low rates of rerevision and other complications at a minimum 2 years after surgery? (2) Is the Wagner SL stem associated with high levels of patient function and pain relief at a minimum 2 years after surgery? (3) Does the Wagner SL stem have low rates of subsidence at a minimum 2 years after surgery? (4) Is the Wagner SL stem associated with proximal femoral bone remodeling at a minimum 2 years after surgery? METHOD: Between May 2011 and December 2012, we performed 198 femoral revisions, of which 104 (53%) were performed using the Wagner SL femoral stem; during that period, our institution gradually shifted toward increasing use of these stems for all but the most severe revisions, in which modular fluted stems and proximal femoral replacements still are used on an occasional basis. Median followup in this retrospective study was 32 months (range, 24-46 months), and one patient was lost to followup before the 2-year minimum. The femoral deformities in this series were Paprosky Type I (10 hips), Paprosky Type II (26), Paprosky Type IIIA (52), Paprosky Type IIIB (nine), and Paprosky Type IV (two). Functional assessment was performed using the Oxford Hip Score (OHS), WOMAC, SF-12, and the University of California Los Angeles (UCLA) activity score. All complications and cases of revision were documented. All patients had radiographs performed within 1 year of the latest followup. These were assessed by two surgeons for signs of proximal femoral bone remodeling and subsidence. RESULTS: Complete preoperative scores were available for 98 patients (98 of 104; 94%). The mean OHS preoperatively and at final followup were 39 (SD, 15) and 87 (SD, 19), respectively (p < 0.001; mean difference, 48; 95% CI, 43-53). Average WOMAC scores were 44 (SD, 15) and 87 (SD, 20), respectively (p < 0.001; mean difference, 43; 95% CI, 38-48). At final followup, signs of restoration of proximal femoral bone stock was noted in 45 of 103 hips (44%). Six (six of 104; 6%) patients had subsidence of 10 mm to 15 mm. In the remainder (98 of 104; 94%), the mean subsidence was 2 mm (range, 0-9 mm). One revision was performed for loosening associated with infection. CONCLUSIONS: The Wagner SL stem is a viable option for patients with Paprosky Types II and III defects undergoing revision THA. This component provides high levels of patient function with low revision rates and low rates of subsidence during the early postoperative phase. They provide a viable alternative to modular components for treatment of Types II and III defects without the risk of junctional fractures. They can be used for very selected Type IV defects, however this extent of bone loss is most easily addressed with other techniques such as a proximal femoral replacement. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Oseointegración/fisiología , Diseño de Prótesis , Titanio , Anciano , Femenino , Humanos , Masculino , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
15.
J Arthroplasty ; 32(3): 915-918, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27776910

RESUMEN

BACKGROUND: Revision hip arthroplasty for metal-on-metal arthroplasty (MOMA) in the presence of an adverse local tissue reaction (ALTR) has been associated with compromised outcomes. We hypothesized that revision of MOMA for painful micromotion of the cup, in the absence of ALTR, would have a more favorable outcome. METHODS: We reviewed our database for Durom acetabular shell revision with minimum 24 months (24 months to 8 years) follow-up. Patients with a diagnosis of painful micromotion in the absence of pseudotumor was identified. RESULTS: At mid-term follow-up, 71 patients had undergone revision of a Durom MOMA. Twenty-seven of these (38%) were for painful micromotion (9 total hip arthroplasty, 18 hip resurfacing) of the cup alone. Following revision surgery, all patients reported resolution of the preoperative pain, as well as satisfactory outcome measures (mean scores: The Western Ontario and McMaster Universities Arthritis Index [WOMAC] 84.6, oxford hip score 84.7, Short Form Health Survey (SF-16) 51, University of California, Los Angeles (UCLA) 7.3). Radiologically, all cases demonstrated osseointegration of the revision shells; 1 case had zone-3 radiolucency that was nonprogressive. One patient had a dislocation treated by closed reduction at 10 weeks. CONCLUSION: Revision MOMA for painful micromotion of the shell in the absence of ALTR is not similar to revision for ALTR and is associated with predictable improvement in pain and quality of life.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Reoperación/estadística & datos numéricos , Acetábulo , Adulto , Anciano , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Oseointegración , Dolor/etiología , Satisfacción del Paciente/estadística & datos numéricos , Calidad de Vida
17.
J Arthroplasty ; 31(8): 1767-72, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27017202

RESUMEN

BACKGROUND: Splined conical stems offer design features that facilitate their use in the misshapen, dysplastic proximal femur. METHODS: This study assessed the survivorship of a conical prosthesis when applied to secondary coxarthrosis because of a range of pathologies. Fifty-one prostheses were implanted in 50 patients with a mean age of 50 (range, 15-80) and a median follow-up of 34 months (range, 24-73 months). Indications for the stem included developmental (36), neuromuscular (7), post-traumatic or surgical (7), and inflammatory conditions (1). Survivorship, functional outcome (WOMAC [Western Ontaria and McMaster University Osteoarthrits Index], Oxford Hip Score, and UCLA [University of California Los Angeles]), health status (short form-12 [SF-12]), satisfaction, and osseointegration were determined. RESULTS: Survivorship for aseptic loosening was 100% at 2 years and 98.04% for septic revision. Eight patients required reoperation, 4 for instability, and 1 each for infection, impingement, adverse reaction to metal debris, and pelvic insufficiency fracture. The mean WOMAC score was 85 (standard deviation [SD], 18), the mean Oxford Hip Score 84 (SD, 18), the mean physical SF-12 score was 48.3 (SD, 8.6), and the mean mental SF-12 was 53.7 (SD, 9.2), the mean satisfaction score was 91.5 (SD, 3.9), and the mean UCLA was 6 (SD, 1.6). All femoral components demonstrated osseointegration. CONCLUSION: The cone femoral prosthesis demonstrates excellent early survival and osseointegration when applied to the challenging femur. Because of these encouraging results, we recommend this prosthesis be considered for the small, abnormal femur in primary hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/cirugía , Prótesis de Cadera , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fémur/anomalías , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Oseointegración , Diseño de Prótesis , Reoperación , Adulto Joven
18.
Ann Pharmacother ; 49(11): 1207-13, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26269097

RESUMEN

BACKGROUND: Antibiotic-impregnated bone cement spacer (ACS) with tobramycin ± vancomycin is commonly used in a 2-stage replacement of infected prosthetic joints. This procedure has been associated with development of acute kidney injury (AKI). OBJECTIVE: To determine the incidence and risk factors for AKI after implantation of tobramycin-impregnated ACS. METHODS: This prospective, observational study evaluated 50 consecutive patients who received tobramycin ACS for first-stage revision of an infected hip or knee arthroplasty from August 2011 to February 2013. AKI was defined as 50% or greater rise in serum creatinine (SCr) from baseline within the first 7 postoperative days (PODs). RESULTS: The incidence of AKI was 20%, with median onset occurring at POD 2 (interquartile range [IQR] = 1-3); patients with AKI had a longer median duration of hospital stay (16 days, IQR = 12-17, vs 10 days, IQR = 8-10; P = 0.03). Serum tobramycin concentrations were significantly higher in the AKI group, peaking on POD 1 (median 1.9 vs 0.9 µg/mL, P = 0.01). Risk factors for nephrotoxicity identified by multivariate analysis were use of bone cement premanufactured with gentamicin (OR = 8.2; 95% CI = 1.1-60; P = 0.04), administration of blood transfusions intraoperatively (OR = 32.5; 95% CI = 2.3-454.3; P = 0.01) and nonsteroidal anti-inflammatory drugs postoperatively (OR = 23.0; 95% CI = 1.3-397.7; P = 0.03). CONCLUSIONS: Tobramycin ACS is associated with a high risk of AKI. Measures to minimize AKI risk in the perioperative period include early detection through close monitoring of SCr, avoiding use of premanufactured bone cement containing gentamicin, and avoiding potential nephrotoxins within the first 72 hours postoperatively.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Antibacterianos/efectos adversos , Cementos para Huesos , Infección de la Herida Quirúrgica/inducido químicamente , Tobramicina/efectos adversos , Lesión Renal Aguda/epidemiología , Anciano , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Creatinina/sangre , Femenino , Gentamicinas/efectos adversos , Humanos , Incidencia , Tiempo de Internación , Masculino , Persona de Mediana Edad , Periodo Perioperatorio , Estudios Prospectivos , Reoperación , Factores de Riesgo , Vancomicina/efectos adversos
19.
Hip Int ; 25(4): 308-15, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26109157

RESUMEN

There is currently no consensus on the optimal management of the infected total hip arthroplasty. Multiple management techniques have been described in contemporary literature.This paper focuses on 2-stage revision for the infected total hip arthroplasty. We discuss the rationale and examine the current evidence for the use of this technique.


Asunto(s)
Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Cadera , Prótesis de Cadera/efectos adversos , Infecciones Relacionadas con Prótesis/terapia , Humanos , Reoperación
20.
Instr Course Lect ; 64: 347-57, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25745919

RESUMEN

It is often challenging to address instability risks when dealing with complex primary total hip arthroplasty and revision hip surgery. The implant-related options available to surgeons to deal with the risks of instability include femoral head size, femoral neck length/offset, component orientation, and the use of constrained articulations. Dual-mobility articulations have long been used in Europe in the setting of a potential or proven unstable hip; this type of articulation is now available in North America after regulatory approval. However, a dual-mobility articulation has its own unique advantages and disadvantages. Before choosing this implant option, the arthroplasty surgeon needs to be fully informed of the design concept, the surgical technique, the advantages, the disadvantages, and the literature surrounding the use of a dual-mobility articulation.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Articulación de la Cadera , Prótesis de Cadera , Inestabilidad de la Articulación/prevención & control , Humanos , Diseño de Prótesis