Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
1.
ESC Heart Fail ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39379167

RESUMEN

AIMS: Baroreceptor activation therapy (BAT) is a promising new treatment strategy for patients with heart failure with reduced ejection fraction (HFrEF). It provides symptomatic relief, improvement in left ventricular function and reduction of cardiac biomarkers. Data regarding the long-term effect of BAT on HFrEF are scarce. This retrospective, monocentric study aimed to assess long-term outcome in patients who underwent BAT. METHODS: Patients with HFrEF who received BAT at Hannover Medical School between 2014 and 2023 were followed until the latest available follow-up. Symptom burden, echocardiography and laboratory testing were assessed before BAT implantation and in subsequent follow-ups. RESULTS: Twenty-three patients (mean age 66 ± 10 years, 83% male) with HFrEF were included in the study. Aetiology of heart failure was ischaemic in 70%. The majority of patients (96%) suffered from New York Heart Association (NYHA) III with a mean left ventricular ejection fraction (LVEF) of 23 ± 8% and N-terminal pro-B-type natriuretic peptide (NT-proBNP) of 2463 ± 2922 pg/mL. A complication occurred in one patient during BAT implantation (4%). The mean follow-up was 3 ± 2 (max. 7.5) years. BAT reduced NYHA classification in 12 patients (52%) after 1 year, of which one patient remained in ameliorated NYHA for 7.5 years. Echocardiographic evaluation revealed significant improvement in LVEF by 9 ± 9% after 1 year (P < 0.001) and by 11 ± 9% (P = 0.005) after 2 years. In addition, BAT mildly reduced NT-proBNP in the first 2 years [non-significantly after 1 year by 396 ± 1006 pg/mL and significantly after 2 years by 566 ± 651 pg/mL (P = 0.039)]. Seven patients reaching the recommended replacement time underwent device exchange. Four patients died during observation time. CONCLUSIONS: BAT resulted in a substantial reduction in NYHA classification and improvement in LVEF that lasted over long-term follow-up in many patients. NT-proBNP level decreased interim in long-term follow-up. These findings highlight the long-term efficacy and potential benefits of BAT as a therapeutic intervention for patients with HFrEF.

2.
Radiother Oncol ; 200: 110499, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39242029

RESUMEN

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) is a therapeutic option for ventricular tachycardia (VT) where catheter-based ablation is not feasible or has previously failed. Target definition and its transfer from electro-anatomic maps (EAM) to radiotherapy treatment planning systems (TPS) is challenging and operator-dependent. Software solutions have been developed to register EAM with cardiac CT and semi-automatically transfer 2D target surface data into 3D CT volume coordinates. Results of a cross-validation study of two conceptually different software solutions using data from the RAVENTA trial (NCT03867747) are reported. METHODS: Clinical Target Volumes (CTVs) were created from target regions delineated on EAM using two conceptually different approaches by separate investigators on data of 10 patients, blinded to each other's results. Targets were transferred using 3D-3D registration and 2D-3D registration, respectively. The resulting CTVs were compared in a core-lab using two complementary analysis software packages for structure similarity and geometric characteristics. RESULTS: Volumes and surface areas of the CTVs created by both methods were comparable: 14.88 ± 11.72 ml versus 15.15 ± 11.35 ml and 44.29 ± 33.63 cm2 versus 46.43 ± 35.13 cm2. The Dice-coefficient was 0.84 ± 0.04; median surface-distance and Hausdorff-distance were 0.53 ± 0.37 mm and 6.91 ± 2.26 mm, respectively. The 3D-center-of-mass difference was 3.62 ± 0.99 mm. Geometrical volume similarity was 0.94 ± 0.05 %. CONCLUSION: The STAR targets transferred from EAM to TPS using both software solutions resulted in nearly identical 3D structures. Both solutions can be used for QA (quality assurance) and EAM-to-TPS transfer of STAR-targets. Semi-automated methods could potentially help to avoid mistargeting in STAR and offer standardized workflows for methodically harmonized treatments.


Asunto(s)
Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiocirugia/métodos , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/diagnóstico por imagen , Programas Informáticos , Tomografía Computarizada por Rayos X , Imagenología Tridimensional , Masculino , Femenino , Reproducibilidad de los Resultados
3.
Europace ; 26(10)2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39344253

RESUMEN

AIMS: Reduction of atrial fibrillation (AF) burden is the preferred outcome measure over categorical AF rhythm recurrence after AF ablation. In this sub-analysis of the TeleCheck-AF project, we tested the feasibility of smartphone app-based approximation of time spent with AF and/or symptoms. METHODS AND RESULTS: Patients scheduled for at least one teleconsultation during the 12-month follow-up after AF ablation were instructed to use a smartphone photoplethysmography-based application for simultaneous symptom and rhythm monitoring three times daily for 1 week. Proxies of time spent with AF and/or symptoms (% recordings, load, and % days), temporal aggregation of AF and/or symptoms (density), and symptom-rhythm correlation (SRC) were assessed. In total, 484 patients (60% male, 62 ± 9.9 years) were included. Adherence, motivation, and patient satisfaction were high. %AF recordings, AF load, and %AF days (rs = 0.88-0.95) and %symptom recordings, symptom load, and %symptom days (rs = 0.95-0.98) showed positive correlations. The SRC correlated negatively with time spent with symptoms (rs = -0.65-0.90) and with time spent with AF (rs = -0.31-0.34). In patients with paroxysmal AF before ablation and AF during the monitoring period, 87% (n = 39/44) had a low-density score <50% ('paroxysmal AF pattern') while 5% (n = 2/44) had a high-density score >90% ('persistent AF pattern'). Corresponding numbers for patients with persistent AF before ablation were 48% (n = 11/23) and 43% (n = 10/23), respectively. CONCLUSION: On-demand, app-based simultaneous rhythm and symptom assessment provides objective proxies of time spent with AF and/or symptoms and SRC, which may assist in assessing AF and symptom outcomes after AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Aplicaciones Móviles , Teléfono Inteligente , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Factores de Tiempo , Resultado del Tratamiento , Fotopletismografía/instrumentación , Fotopletismografía/métodos , Satisfacción del Paciente/estadística & datos numéricos , Recurrencia , Frecuencia Cardíaca , Consulta Remota , Cooperación del Paciente/estadística & datos numéricos , Telemedicina , Motivación
4.
Eur Heart J Open ; 4(5): oeae070, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39253029

RESUMEN

Aims: Female physicians are underrepresented in invasive electrophysiology (EP) for multiple reasons. Despite an increasing focus on the topic, it is unclear what aspects are predominant. Methods and results: We conducted a survey on career paths of current or former EP fellows in Germany to elucidate how gender and family affected their careers. 231 fellows (24.2% female) were invited. 110 participants completed the survey (30.9% female, mean age 41.0 ± 5.0 years, and 79.1% with children). Female and male participants with children reported similar career goals and achievements before parenthood, but afterwards women changed their career paths more often. Major reasons were personal priorities followed by lack of flexibility at work and at home. Women covered the majority of childcare. At the time of the survey, 80.0% of women and 96.4% of men with a former career goal of invasive EP were active in invasive EP. Independent of age, women were in lower-level positions, had accomplished fewer professional achievements, were less satisfied with their work and had fewer children. 56.5% of women did not feel supported by their employers regarding family issues. 82.6% reported there was no satisfactory day care. 69.6% were unable to continue to follow their career during pregnancy, mostly due to restrictions by employers (75.0%). Dedicated policies for pregnant workers or support programmes were scarce. Conclusion: Beside the distribution of childcare at home, lack of flexibility and support by employers as well as working and fluoroscopy restrictions during pregnancy hamper women in EP and should be addressed.

5.
Int J Cardiol ; 415: 132454, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39151480

RESUMEN

BACKGROUND AND AIMS: Cardiac Implantable Electronic Device (CIED) infections pose significant mortality and morbidity despite optimal treatment. This survey aimed to understand whether and how the risk of CIED infection is assessed and mitigated in clinical practice in Europe, and to detect gaps with respect to EHRA recommendations. METHODS: An Expert Group of 8 European cardiologists with specific expertise across CIED therapy designed and distributed electronically a survey to a number of European Cardiologists. RESULTS: 302 physicians from 18 European countries responded to the survey. 288/302 (95%) physicians agreed that CIED-related infections represent a burden on healthcare resources and are associated with significant morbidity and mortality. 285/302 respondents (94%) primarily assess the risk of CIED infections by only evaluating the patient's clinical profile (137/302, 46%) or with the support of a risk score (148/302, 49%). Intravenous antibiotic prophylaxis is used by 282/302 (93%), followed by the implantation of the lowest number of leads possible (182/302, 60%), and by the use of an antibacterial envelope (173/302, 57%). 230/302 respondents (76%) declared that there is need for clear and concise guidelines and more sensitive risk-scores for CIED infection, to maximize the chances of preventative strategies. CONCLUSIONS: This survey demonstrates a high level of awareness about the multifaceted issue of CIED infection, however, it also highlights an incomplete penetration of scoring systems for risk stratification owing to their perceived limitations, and detects a strong commitment to increase the effectiveness of preventative strategies.


Asunto(s)
Desfibriladores Implantables , Infecciones Relacionadas con Prótesis , Humanos , Europa (Continente)/epidemiología , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Encuestas y Cuestionarios , Marcapaso Artificial/efectos adversos , Cardiólogos , Médicos , Femenino , Masculino , Concienciación , Conocimientos, Actitudes y Práctica en Salud , Pautas de la Práctica en Medicina
6.
Herzschrittmacherther Elektrophysiol ; 35(3): 226-233, 2024 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-39168897

RESUMEN

As an alternative to transvenous ICD systems, two non-transvenous ICD systems have been established in recent years: The subcutaneous ICD (S-ICD), which has been established for several years, has a presternal electrode that is implanted subcutaneously and offers a shock function and, to a limited extent, post-shock pacing. In addition, the extravascular ICD (EV-ICD) has been available in Europe since 2023 which does not require transvenous electrodes and offers the option of providing patients with antibradycardic and antitachycardic stimulation in combination with a conventional ICD function. The lead of this device is implanted substernally. Initial implantation results are promising in terms of safety and effectiveness. Both systems avoid possible complications of transvenous electrodes. This article provides practical guidance for the implantation technique and possible complications.


Asunto(s)
Desfibriladores Implantables , Implantación de Prótesis , Humanos , Diseño de Equipo , Medicina Basada en la Evidencia , Guías de Práctica Clínica como Asunto , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Implantación de Prótesis/normas , Resultado del Tratamiento
8.
Eur Heart J ; 45(30): 2771-2781, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-38864173

RESUMEN

BACKGROUND AND AIMS: In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. METHODS: Patients with HFrEF and LVEF ≤ 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. RESULTS: A total of 598 patients with de novo HFrEF [59 years (interquartile range 51-68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin-angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%-50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%-52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%-72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%-81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. CONCLUSIONS: Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Femenino , Masculino , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Persona de Mediana Edad , Anciano , Volumen Sistólico/fisiología , Antagonistas de Receptores de Mineralocorticoides/uso terapéutico , Función Ventricular Izquierda/fisiología , Desfibriladores Implantables , Antagonistas Adrenérgicos beta/uso terapéutico , Duración de la Terapia , Dispositivos Electrónicos Vestibles , Sistema de Registros
10.
Herzschrittmacherther Elektrophysiol ; 35(2): 155-164, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38748284

RESUMEN

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Electrodos Implantados , Humanos , Medicina Basada en la Evidencia , Implantación de Prótesis/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos
11.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38666444

RESUMEN

Stereotactic arrhythmia radioablation (STAR) is a treatment option for recurrent ventricular tachycardia/fibrillation (VT/VF) in patients with structural heart disease (SHD). The current and future role of STAR as viewed by cardiologists is unknown. The study aimed to assess the current role, barriers to application, and expected future role of STAR. An online survey consisting of 20 questions on baseline demographics, awareness/access, current use, and the future role of STAR was conducted. A total of 129 international participants completed the survey [mean age 43 ± 11 years, 25 (16.4%) female]. Ninety-one (59.9%) participants were electrophysiologists. Nine participants (7%) were unaware of STAR as a therapeutic option. Sixty-four (49.6%) had access to STAR, while 62 (48.1%) had treated/referred a patient for treatment. Common primary indications for STAR were recurrent VT/VF in SHD (45%), recurrent VT/VF without SHD (7.8%), or premature ventricular contraction (3.9%). Reported main advantages of STAR were efficacy in the treatment of arrhythmias not amenable to conventional treatment (49%) and non-invasive treatment approach with overall low expected acute and short-term procedural risk (23%). Most respondents have foreseen a future clinical role of STAR in the treatment of VT/VF with or without underlying SHD (72% and 75%, respectively), although only a minority expected a first-line indication for it (7% and 5%, respectively). Stereotactic arrhythmia radioablation as a novel treatment option of recurrent VT appears to gain acceptance within the cardiology community. Further trials are critical to further define efficacy, patient populations, as well as the appropriate clinical use for the treatment of VT.


Asunto(s)
Radiocirugia , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Adulto , Persona de Mediana Edad , Fibrilación Ventricular/cirugía , Fibrilación Ventricular/fisiopatología , Radiocirugia/tendencias , Encuestas de Atención de la Salud , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Resultado del Tratamiento , Pautas de la Práctica en Medicina/tendencias , Pautas de la Práctica en Medicina/estadística & datos numéricos , Cardiólogos/tendencias , Electrofisiología Cardíaca/tendencias
12.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38591838

RESUMEN

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Riesgo , Hemorragia , Anticoagulantes/uso terapéutico
13.
J Clin Med ; 13(6)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38541790

RESUMEN

In patients with unexplained syncope, implantable loop recorders (ILR) are used to detect arrhythmias as a cause of syncope. This study aimed to assess the diagnostic yield and clinical implications arising from ILR implantation in patients with syncope in Germany. Secondary longitudinal data were obtained from a large German research database including anonymized data from nationwide statutory health insurances, representative for the German population. Patients ≥ 18 years with a diagnosis of syncope and ILR implantation between 2017 and 2018 were analyzed, and cardiac diagnoses and therapies during a follow-up period of two years assessed. Of 2,403,301 continuously insured persons in 2017-2018, 1360 (0.1%) received an ILR and 675 patients (45.6% female) were included. During follow-up, arrhythmias were diagnosed in 65.0%. The following antiarrhythmic therapies were established: pacemaker and defibrillator implantations in 20% and 1.5%, respectively, ablation therapy in 3.0%, and antiarrhythmic drug therapy in 4.7%. Aside from the diagnoses typically associated with syncope, atrial fibrillation or flutter was diagnosed in 37.0%, and anticoagulation therapy was initiated in 21.5%. There was a high diagnostic yield of arrhythmias following ILR implantation, leading to a relevant number of syncope-specific treatment. Arrhythmias not necessarily related to syncope were also diagnosed, leading to a high rate of anticoagulation therapy.

14.
Int J Cardiol Heart Vasc ; 50: 101328, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38419603

RESUMEN

Aim: Social media (SoMe) are emerging as important tools for research dissemination. Twitter/X promotion has been shown to increase citation rates in well-established journals. We aimed to test the effect of a SoMe promotion strategy on the Mendeley reader counts, the Altmetric Attention Score and the number of citations in an upcoming open-access journal. Methods: The #TweetTheJournal study is a randomized, controlled study. Articles published in seven subsequent issues of the International Journal of Cardiology Heart & Vasculature (April 2021-April 2022) were randomized to a Twitter/X promotion arm (articles were posted four times) and to a control arm (without active posting). Articles with accompanied editorials were excluded. Primary endpoint of the study was Mendeley reader count, secondary endpoints were Altmetric Attention Score and number of citations. Follow-up was one year. Results: SoMe promotion of articles showed no statistically significant difference in Mendeley reader counts or number of citations at one year follow up. SoMe promotion resulted in a statistically significant higher Altmetric Attention Score in the intervention compared to the control group (RR 1.604, 95 % CI 1.024-2.511, p = 0.039). In the overall group, Altmetric Attention Score showed a correlation with Mendeley reader counts (Spearman's ρ = 0.202, p = 0.010) and Mendeley reader counts correlated significantly with number of citations (Spearman's ρ = 0.372, p < 0.001). Conclusion: A dedicated SoMe promotion strategy did not result in statistically significant differences in early impact indicators as the Mendeley reader count in a upcoming journal, but increased the Altmetric Attention Score.

15.
Sci Rep ; 14(1): 3799, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360886

RESUMEN

Ventricular tachyarrhythmia (VTA) are frequent arrhythmias in patients with hypertrophic cardiomyopathy (HCM). Representing a major risk factor for sudden cardiac death, Holter ECG at first clinical presentation appears insufficient. This study aims to investigate the ability of routinely obtained parameters associated with myocardial remodeling in stratifying for VTA in HCM. In this monocentric analysis, patients with HCM underwent 12-channel electrocardiography and echocardiography, including tissue doppler imaging. The study's primary endpoint was the documentation of non-sustained and sustained ventricular tachycardia-summarized as ventricular tachyarrhythmias (VTA) on Holter ECG or active devices. The occurrence of VTA was exploratory. Based on our collective, we developed a risk model regarding VTA. Of 140 HCM patients, 38 (27.1%) had an episode of VTA. Patients with VTA were likelier to have a history of atrial fibrillation (p < 0.001), a thicker interventricular septum (p < 0.001) and lower peak systolic mitral annular velocity (p < 0.001). The parameters were independently associated with endpoint in univariate and multivariate logistic regression. We created a logistic equation and calculated a cut-off value. The resulting ROC curve revealed a discriminative ability with AUC of 0.80 (sensitivity, 63%; specificity, 88%). Our risk model including these widely available parameters is able to distinguish low and high-risk of VTA in patients with HCM.


Asunto(s)
Cardiomiopatía Hipertrófica , Taquicardia Ventricular , Humanos , Proyectos Piloto , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía/efectos adversos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/complicaciones , Factores de Riesgo , Medición de Riesgo , Muerte Súbita Cardíaca/etiología
16.
Herzschrittmacherther Elektrophysiol ; 35(2): 111-117, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38334830

RESUMEN

The characterization of atrial fibrillation (AF) according to current guidelines categorically refers to the differentiation between paroxysmal, persistent, and permanent AF. A more precise characterization of AF, including the evaluation of AF burden, is playing an increasingly significant role in both scientific research and clinical practice. Digital devices, especially those with the capability of passive (semi-)continuous recording, can contribute to a more accurate quantification of AF burden. Particularly in patients with an already established diagnosis of AF, the evaluation of AF burden can be used to monitor the success of antiarrhythmic therapy including antiarrhythmic drugs or pulmonary vein isolation. However, important questions remain unanswered: In addition to a uniform, evidence-based definition of AF burden, clinically relevant cut-offs for AF burden and resulting therapeutic consequences (e.g., subclinical AF) need to be elaborated. Furthermore, the establishment and evaluation of care structures for assessing and integrating AF burden in clinical care, especially by incorporating data from wearable medical devices, should take place.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Dispositivos Electrónicos Vestibles , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Humanos , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Sensibilidad y Especificidad , Reproducibilidad de los Resultados , Diagnóstico por Computador , Medicina Basada en la Evidencia , Análisis de Falla de Equipo
17.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38293821

RESUMEN

AIMS: Simulator training has been recently introduced in electrophysiology (EP) programmes in order to improve catheter manipulation skills without complication risks. The aim of this study is to survey the current use of EP simulators and the perceived need for these tools in clinical training and practice. METHODS AND RESULTS: A 20-item online questionnaire developed by the Scientific Initiatives Committee of the European Heart Rhythm Association (EHRA) in collaboration with EHRA Digital Committee was disseminated through the EHRA Scientific Research Network members, national EP groups, and social media platforms. Seventy-four respondents from 22 countries (73% males; 50% under 40 years old) completed the survey. Despite being perceived as useful among EP professionals (81%), EP simulators are rarely a part of the institutional cardiology training programme (20%) and only 18% of the respondents have an EP simulator at their institution. When available, simulators are mainly used in EP to train transseptal puncture, ablation, and mapping, followed by device implantation (cardiac resynchronization therapy [CRT], leadless, and conduction system pacing [CSP]). Almost all respondents (96%) believe that simulator programmes should be a part of the routine institutional EP training, hopefully developed by EHRA, in order to improve the efficacy and safety of EP procedures and in particular CSP 58%, CRT 42%, leadless pacing 38%, or complex arrhythmia ablations (VT 58%, PVI 45%, and PVC 42%). CONCLUSION: This current EHRA survey identified a perceived need but a lack of institutional simulator programme access for electrophysiologists who could benefit from it in order to speed up the learning curve process and reduce complications of complex EP procedures.


Asunto(s)
Terapia de Resincronización Cardíaca , Médicos , Masculino , Humanos , Adulto , Femenino , Encuestas y Cuestionarios , Terapia de Resincronización Cardíaca/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Electrofisiología Cardíaca , Trastorno del Sistema de Conducción Cardíaco/terapia , Europa (Continente)
18.
Eur Heart J Digit Health ; 5(1): 97-100, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38264695

RESUMEN

Aims: TeleCheck-AF is a novel remote on-demand mobile health infrastructure around teleconsultations for patients with atrial fibrillation. Social media (SoMe) communication on Twitter contributed to the dissemination of this healthcare innovation by using the hashtag #TeleCheckAF. This study aims to analyse the SoMe network behind #TeleCheckAF and determine the key opinion leaders. Methods and results: Publicly available data on actors and interactions around the hashtag #TeleCheckAF were collected by web scraping from the platform Twitter. With tools based on social network analysis, a social network was created, different communities were identified, and key opinion leaders were determined by their centrality in the network. The SoMe network consisted of 413 086 accounts with 636 502 ties in 22 different communities. A total of 287 accounts that diffused information and/or used the TeleCheck-AF infrastructure were analysed in depth. Those accounts involved users from >15 different countries and multidisciplinary professions. Further, 20 opinion leaders were identified, including four official accounts of societies and associated journals among key opinion leaders. Peaks in #TeleCheckAF tweets were seen after (virtual) conferences and other activities involving national and international cardiology societies. Social network analysis of the TeleCheck-AF Twitter hashtag revealed a wide, multidisciplinary potential reach for the diffusion of a healthcare innovation. Conclusion: Official society SoMe accounts can amplify the dissemination of research findings by featuring abstract presentations during conferences and published manuscripts. This underlines the synergistic effects between traditional and SoMe-based research dissemination strategies for novel healthcare approaches, such as the TeleCheck-AF project.

19.
Herzschrittmacherther Elektrophysiol ; 35(1): 83-90, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38289503

RESUMEN

Cardiovascular implantable electronic devices (CIED) are an important part of modern cardiology and careful perioperative planning of these procedures is necessary. All information relevant to the indication, the procedure, and the education of the patient must be available prior to surgery. This provides the basis for appropriate device selection. Preoperative antibiotic prophylaxis and perioperative anticoagulation management are essential to prevent infection. After surgery, postoperative monitoring, telemetric control, and device-based diagnostics are required before discharge. These processes need to be adapted to the increasing trend towards outpatient care. This review summarises perioperative management based on practical considerations.


Asunto(s)
Cardiología , Desfibriladores Implantables , Marcapaso Artificial , Humanos
20.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38127304

RESUMEN

AIMS: Natural language processing chatbots (NLPC) can be used to gather information for medical content. However, these tools contain a potential risk of misinformation. This study aims to evaluate different aspects of responses given by different NLPCs on questions about atrial fibrillation (AF) and clinical implantable electronic devices (CIED). METHODS AND RESULTS: Questions were entered into three different NLPC interfaces. Responses were evaluated with regard to appropriateness, comprehensibility, appearance of confabulation, absence of relevant content, and recommendations given for clinically relevant decisions. Moreover, readability was assessed by calculating word count and Flesch Reading Ease score. 52, 60, and 84% of responses on AF and 16, 72, and 88% on CIEDs were evaluated to be appropriate for all responses given by Google Bard, (GB) Bing Chat (BC) and ChatGPT Plus (CGP), respectively. Assessment of comprehensibility showed that 96, 88, and 92% of responses on AF and 92 and 88%, and 100% on CIEDs were comprehensible for all responses created by GB, BC, and CGP, respectively. Readability varied between different NLPCs. Relevant aspects were missing in 52% (GB), 60% (BC), and 24% (CGP) for AF, and in 92% (GB), 88% (BC), and 52% (CGP) for CIEDs. CONCLUSION: Responses generated by an NLPC are mostly easy to understand with varying readability between the different NLPCs. The appropriateness of responses is limited and varies between different NLPCs. Important aspects are often missed to be mentioned. Thus, chatbots should be used with caution to gather medical information about cardiac arrhythmias and devices.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Inteligencia Artificial , Factores de Riesgo , Electrónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...