1.
J Thorac Oncol ; 14(3): 408-419, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30521969

RESUMEN

INTRODUCTION: Quality of life (QoL) of comorbid patients with pulmonary malignancies is a key issue in considering fractionated stereotactic body radiotherapy (SBRT) indication. This study investigates the early impact of SBRT on QoL. METHODS: One hundred patients with pulmonary lesions were treated with SBRT from February 2011 to December 2014 within the prospective, monocenter, phase II STRIPE trial. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core module (EORTC QLQ-C30) and the QLQ-LC13 lung cancer-specific questionnaire were used to evaluate QoL before, 2 and 7 weeks after SBRT, then every 3 months for 2 years. We report on the analysis of early changes from baseline to 7-week follow-up exam. Impact of patient- and treatment-related factors on the change in QoL was analyzed. RESULTS: QoL was assessed in 97 patients; compliance was 92% and 85% at baseline and 7 weeks after SBRT, respectively. No clinically relevant changes greater than or equal to 10 in the QoL/global health status (GHS), function scores and inquired symptoms were observed. Patients with baseline QoL below the median showed clinically relevant improvement in QoL/GHS (Δ16.7 ± 25.3, p = 0.003), emotional function (Δ14.4 ± 25.4, p = 0.013), and fatigue (Δ -10.1 ± 26.5, p = 0.089) in contrast to patients with high initial scores. No changes were observed in the dichotomized subgroups of initial Karnofsky index, Charlson Comorbidity Index, age, diagnosis, and tumor localization. CONCLUSIONS: In short-term follow-up, QoL is well maintained after pulmonary SBRT. Especially patients with low initial QoL/GHS scores show benefit from SBRT with respect to QoL.


Asunto(s)
Estado de Salud , Neoplasias Pulmonares/cirugía , Calidad de Vida , Radiocirugia/métodos , Anciano , Fraccionamiento de la Dosis de Radiación , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/patología , Masculino , Pronóstico , Estudios Prospectivos , Encuestas y Cuestionarios
2.
Eur J Cancer ; 51(17): 2525-33, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26277100

RESUMEN

PURPOSE: Oncologic imaging is a key for successful cancer treatment. While the quality assurance (QA) of image acquisition protocols has already been focussed, QA of reading and reporting offers still room for improvement. The latter was addressed in the context of a prospective multicentre trial on fluoro-deoxyglucose (FDG)-positron-emission tomography (PET)/CT-based chemoradiotherapy for locally advanced non-small cell lung cancer (NSCLC). MATERIAL AND METHODS: An expert panel was prospectively installed performing blinded reviews of mediastinal NSCLC involvement in FDG-PET/CT. Due to a high initial reporting inter-observer disagreement, the independent data monitoring committee (IDMC) triggered an interventional harmonisation process, which overall involved 11 experts uttering 6855 blinded diagnostic statements. After assessing the baseline inter-observer agreement (IOA) of a blinded re-review (phase 1), a discussion process led to improved reading criteria (phase 2). Those underwent a validation study (phase 3) and were then implemented into the study routine. After 2 months (phase 4) and 1 year (phase 5), the IOA was reassessed. RESULTS: The initial overall IOA was moderate (kappa 0.52 CT; 0.53 PET). After improvement of reading criteria, the kappa values improved substantially (kappa 0.61 CT; 0.66 PET), which was retained until the late reassessment (kappa 0.71 CT; 0.67 PET). Subjective uncertainty was highly predictive for low IOA. CONCLUSION: The IOA of an expert panel was significantly improved by a structured interventional harmonisation process which could be a model for future clinical trials. Furthermore, the low IOA in reporting nodal involvement in NSCLC may bear consequences for individual patient care.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Carcinoma de Pulmón de Células no Pequeñas/terapia , Quimioradioterapia/métodos , Método Doble Ciego , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Pulmonares/terapia , Variaciones Dependientes del Observador , Evaluación de Resultado en la Atención de Salud/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Strahlenther Onkol ; 191(6): 525-33, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25665799

RESUMEN

INTRODUCTION: Interobserver variability in the definition of target volumes (TVs) is a well-known confounding factor in (multicentre) clinical studies employing radiotherapy. Therefore, detailed contouring guidelines are provided in the prospective randomised multicentre PET-Plan (NCT00697333) clinical trial protocol. This trial compares strictly FDG-PET-based TV delineation with conventional TV delineation in patients with locally advanced non-small cell lung cancer (NSCLC). Despite detailed contouring guidelines, their interpretation by different radiation oncologists can vary considerably, leading to undesirable discrepancies in TV delineation. Considering this, as part of the PET-Plan study quality assurance (QA), a contouring dummy run (DR) consisting of two phases was performed to analyse the interobserver variability before and after teaching. MATERIALS AND METHODS: In the first phase of the DR (DR1), radiation oncologists from 14 study centres were asked to delineate TVs as defined by the study protocol (gross TV, GTV; and two clinical TVs, CTV-A and CTV-B) in a test patient. A teaching session was held at a study group meeting, including a discussion of the results focussing on discordances in comparison to the per-protocol solution. Subsequently, the second phase of the DR (DR2) was performed in order to evaluate the impact of teaching. RESULTS: Teaching after DR1 resulted in a reduction of absolute TVs in DR2, as well as in better concordance of TVs. The Overall Kappa(κ) indices increased from 0.63 to 0.71 (GTV), 0.60 to 0.65 (CTV-A) and from 0.59 to 0.63 (CTV-B), demonstrating improvements in overall interobserver agreement. CONCLUSION: Contouring DRs and study group meetings as part of QA in multicentre clinical trials help to identify misinterpretations of per-protocol TV delineation. Teaching the correct interpretation of protocol contouring guidelines leads to a reduction in interobserver variability and to more consistent contouring, which should consequently improve the validity of the overall study results.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Maniquíes , Oncología por Radiación/educación , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Competencia Clínica , Alemania , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Países Bajos , Variaciones Dependientes del Observador , Cintigrafía , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Tumoral
4.
Strahlenther Onkol ; 190(5): 491-3, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24615187

RESUMEN

Radiation recall dermatitis (RRD) is an acute skin toxicity caused by different anticancer or antibiotic drugs within a former completely healed irradiation field. Predictive factors for RRD are not known and its mechanisms are not completely understood. A case of RRD induced by docetaxel and successfully treated by an antioxidant ointment (Mapisal(®)) is presented here. Such an ointment might be useful not only in RRD therapy, but also in the treatment of high-grade dermatitis induced by radiotherapy and thus may contribute to the improvement of patients' quality of life and to the scheduled completion of cancer therapies.


Asunto(s)
Antineoplásicos/efectos adversos , Antioxidantes/administración & dosificación , Neoplasias Óseas/secundario , Neoplasias Óseas/terapia , Neoplasias de la Próstata/terapia , Radiodermatitis/inducido químicamente , Taxoides/efectos adversos , Antineoplásicos/uso terapéutico , Neoplasias Óseas/patología , Quimioradioterapia , Docetaxel , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pomadas , Neoplasias de la Próstata/patología , Radiodermatitis/tratamiento farmacológico , Taxoides/uso terapéutico
5.
Asian Cardiovasc Thorac Ann ; 21(1): 48-55, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23430420

RESUMEN

BACKGROUND: The effect of pleurectomy/decortication or extrapleural pleuropneumonectomy on pulmonary function has not yet been evaluated. The aim of this study was to determine the parameters of pulmonary function before and after pleurectomy/decortication or extrapleural pleuropneumonectomy. METHODS: We conducted a review of 48 patients with unilateral malignant pleural mesothelioma who underwent pleurectomy/decortication or extrapleural pleuropneumonectomy. Data including medical history, histology, survival, and pre- and postoperative pulmonary function were extracted from the medical database of the University Medical Center Freiburg, or sought by telephone interview with the general practitioner or patients. RESULTS: 25 patients underwent extrapleural pleuropneumonectomy and 23 had pleurectomy/decortication. Pulmonary function was not significantly reduced in the pleurectomy/decortication group postoperatively. In the extrapleural pleuropneumonectomy group, the median preoperative total lung capacity of 4.8 L (77.7%) differed significantly from the postoperative total lung capacity of 3.5 L (55.3%; p <0.0006). The median vital capacity was significantly reduced from 2.8 L (77.7%) preoperatively to 1.8 L (47.6%) postoperatively (p <0.0002). Other parameters were also highly significantly reduced after extrapleural pleuropneumonectomy. CONCLUSIONS: Pleurectomy/decortication preserved good pulmonary function, whereas extrapleural pleuropneumonectomy significantly reduced pulmonary function, which may lead to dyspnea and influence the quality of life of these patients.


Asunto(s)
Pulmón/cirugía , Mesotelioma/cirugía , Pleura/cirugía , Neoplasias Pleurales/cirugía , Neumonectomía , Anciano , Disnea/etiología , Disnea/fisiopatología , Femenino , Volumen Espiratorio Forzado , Alemania , Humanos , Estimación de Kaplan-Meier , Pulmón/fisiopatología , Masculino , Mesotelioma/mortalidad , Mesotelioma/fisiopatología , Persona de Mediana Edad , Análisis Multivariante , Neoplasias Pleurales/mortalidad , Neoplasias Pleurales/fisiopatología , Neumonectomía/efectos adversos , Neumonectomía/mortalidad , Modelos de Riesgos Proporcionales , Calidad de Vida , Estudios Retrospectivos , Factores de Tiempo , Capacidad Pulmonar Total , Resultado del Tratamiento , Capacidad Vital
6.
Strahlenther Onkol ; 187(11): 750-6, 2011 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-22037653

RESUMEN

INTRODUCTION AND BACKGROUND: In the context of quality assurance, increasing demands are placed on the whole radiotherapy treatment process. The patients directly concerned generally do not realize most aspects of the quality assurance program (e.g., additional safety checks) during their daily therapy. It was the aim of this study to systematically ask patients about potential improvements during the course of radiotherapy treatment from their own perspective. PATIENTS AND METHODS: In the defined time span (1 month), 624 radiotherapy patients (600 questionnaires were returned, 96.2%) were interviewed using a questionnaire newly developed to inquire about several aspects of their treatment. Furthermore, they were asked for their specific needs and suggestions for improvements that could be made during the course of radiotherapy treatment. RESULTS: Overall, the patients were satisfied with the course of their radiotherapy treatment and with patient care. As an example, about 90% agreed with the statement: "My first contact with the radiation oncology unit proceeded with kindness and competence so that I was given the impression that I will be well cared for in this clinic." Considering the organization of the course of radiotherapy, a large majority of patients attached great value to set appointments for the therapy fractions. A main point of criticism was waiting times or delays caused by servicing or machine failures. Small, low cost improvements as music in the therapy room were considered as important as expensive measures (e.g., daylight in the therapy room). The patients emphasized the importance of staff friendliness. CONCLUSION: The situation of radiotherapy patients was, in general, satisfactory. Future improvements can be mainly expected from smooth organisation of both planning and treatment which can be achieved by electronic scheduling systems. Many results of the survey could be easily implemented in daily practice. In matters of organization radiation oncology with its complex procedures can be used as a model for other clinical departments.


Asunto(s)
Satisfacción del Paciente , Mejoramiento de la Calidad , Radioterapia , Encuestas y Cuestionarios , Femenino , Alemania , Necesidades y Demandas de Servicios de Salud/organización & administración , Humanos , Masculino , Neoplasias/psicología , Neoplasias/radioterapia , Planificación de Atención al Paciente/organización & administración , Educación del Paciente como Asunto , Seguridad del Paciente , Relaciones Profesional-Paciente , Garantía de la Calidad de Atención de Salud , Mejoramiento de la Calidad/organización & administración , Calidad de Vida/psicología , Radioterapia/efectos adversos , Radioterapia/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA