Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36730600

RESUMEN

PURPOSE: To describe 3 cases of chronic central serous chorioretinopathy (CSCR) in the pediatric patient population. METHODS: Retrospective case series. RESULTS: We report three pediatric patients with CSCR. All patients initially presented following failed vision screens or during routine office examinations. All patients presented with macula-involving subretinal fluid and multimodal imaging features consistent with chronic central serous chorioretinopathy. At last-follow-up, 1 patient had minimal residual subretinal fluid, 1 patient had a small recurrence of subretinal fluid, and 1 patient had persistent subretinal fluid. CONCLUSIONS: While CSCR classically occurs in adults, it can be seen in pediatric patients. Given the rarity of this condition in the pediatric population, CSCR may go undetected and underreported with diagnosis resulting from failed vision screens.

2.
Anal Bioanal Chem ; 392(3): 409-16, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18696054

RESUMEN

A low-volume automated injection system for the analysis of chemically complex, amino acid samples is presented. This system utilizes submicroliter sample volumes stored on a 75-mum inner diameter capillary. A pulse of positive pressure (82 kPa) is used to load nanoliter sample volumes into an in-house fabricated interface and onto a separation capillary. Residual sample solution in the interface is immediately washed away by a continuous transverse flow through the injection interface, yielding a sharp and reproducible sample plug. By performing multiple injections of a static sample, one may average the signals to yield a signal-to-noise ratio improvement of up to 4.07-fold for 20 injections compared with a theoretical maximum of a 4.47-fold improvement. Without interruption of the applied voltage, injections performed every 150 s were used to monitor the progress of the reaction of multiple amino acids with the fluorogenic dye 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde. Analysis of dialyzed clinical vitreous samples demonstrates the resolution and quantitation of arginine, lysine, leucine, glutamine, and glutamate. Observed levels are comparable with those of nonautomated injection methods and reports by others.


Asunto(s)
Aminoácidos/análisis , Electroforesis Capilar/instrumentación , Electroforesis Capilar/métodos , Cuerpo Vítreo/química , Cuerpo Vítreo/metabolismo , Diálisis , Humanos
3.
Analyst ; 132(10): 1046-52, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17893809

RESUMEN

The detection of peptides with mass spectrometry from volume-limited biological samples is a challenging task due to low sample volume, a broad range of peptide concentrations down to trace levels, endogenous high proteins and salt levels. Previously, a microspotting method was presented for trace-level peptide detection with MALDI-MS from sub-microlitre samples with biological salt levels. However, in the presence of proteins, peptide signals are significantly reduced. This paper presents a novel dialysis device for removal of proteins from sub-microlitre samples using a semipermeable hollow fiber membrane to enhance peptide detection. A dialysis device was constructed to perform sub-microlitre dialysis to remove proteins from complex samples. Angiotensin I was used as a model peptide in the presence of 350 mg L(-1) BSA prepared in physiological saline to mimic biological samples. In the absence of BSA, clear angiotensin I peaks were seen at 250 pM, yet in the presence of the BSA, 10 nM angiotensin I was barely detected. After dialysis, peak detection was improved to a 500 pM level. Protein removal and peptide recovery (approximately 66%) were determined using CE-LIF. Clinical vitreous samples as low as 200 nL were successfully dialyzed in 30 min and a 3-fold increase in peptide peaks were detected with greatly improved signals. This method is simple and can be a useful technique for trace level peptide detection from volume-limited biological samples.


Asunto(s)
Péptidos/análisis , Angiotensina I/análisis , Calibración , Electroforesis Capilar/métodos , Humanos , Microdiálisis/instrumentación , Microdiálisis/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
4.
Exp Diabetes Res ; 2007: 39765, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17713596

RESUMEN

Elevated glutamate is implicated in the pathology of PDR. The ability to rapidly assess the glutamate and amino acid content of vitreous provides a more complete picture of the chemical changes occurring at the diabetic retina and may lead to a better understanding of the pathology of PDR. Vitreous humor was collected following vitrectomies of patients with PDR and control conditions of macular hole or epiretinal membrane. A capillary electrophoresis method was developed to quantify glutamate and arginine. The analysis is relatively fast (<6 minutes) and utilizes a poly(ethylene)oxide and sodium dodecylsulfate run buffer. Both amino acid levels show significant increases in PDR patients versus controls and are comparable to other reports. The levels of vitreal glutamate vary inversely with the degree of observed hemorrhage. The results demonstrate a rapid method for assessment of a number of amino acids to characterize the chemical changes at the diabetic retina to better understand tissue changes and potentially identify new treatments.


Asunto(s)
Aminoácidos/metabolismo , Retinopatía Diabética/metabolismo , Transducción de Señal , Cuerpo Vítreo/metabolismo , Anciano , Arginina/análisis , Electroforesis Capilar/métodos , Membrana Epirretinal/metabolismo , Femenino , Ácido Glutámico/análisis , Humanos , Masculino , Persona de Mediana Edad , Perforaciones de la Retina/metabolismo , Manejo de Especímenes , Factores de Tiempo , Cuerpo Vítreo/química , Hemorragia Vítrea/metabolismo , Hemorragia Vítrea/fisiopatología
5.
Artículo en Inglés | MEDLINE | ID: mdl-17098486

RESUMEN

The determination of nitric oxide (NO) in human vitreous samples is complicated by the relatively short half-life of the analyte and the viscous, high salt and protein biological matrix. In this work, we developed a fast (<5min) and useful CE method to determine the stable metabolite, nitrate, from vitreous samples. This proposed method has been successfully applied to determine the nitrate levels from the vitreous humor of patients undergoing vitrectomy for a variety of conditions. A statistically significant increase (P=0.000001) of the mean level of nitrate was observed in vitreous humor of patients with proliferative diabetic retinopathy (41.17+/-4.09microM, n=27) versus controls (15.22+/-0.86microM, n=35). The elevated levels of nitrate in the vitreous of patients known to have diabetic retinopathy suggests that NO is involved with the pathology of this disease.


Asunto(s)
Retinopatía Diabética/metabolismo , Electroforesis Capilar/métodos , Nitratos/análisis , Cuerpo Vítreo/química , Humanos , Reproducibilidad de los Resultados , Vitrectomía , Cuerpo Vítreo/patología , Cuerpo Vítreo/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...