Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomicrofluidics ; 17(5): 054104, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37840538

RESUMEN

Despite the large number of microfluidic devices that have been described over the past decade for the study of tissues and organs, few have become widely adopted. There are many reasons for this lack of adoption, primarily that devices are constructed for a single purpose or because they are highly complex and require relatively expensive investment in facilities and training. Here, we describe a microphysiological system (MPS) that is simple to use and provides fluid channels above and below cells, or tissue biopsies, maintained on a disposable, poly(methyl methacrylate), carrier held between polycarbonate outer plates. All other fittings are standard Luer sizes for ease of adoption. The carrier can be coated with cells on both sides to generate membrane barriers, and the devices can be established in series to allow medium to flow from one cell layer to another. Furthermore, the carrier containing cells can be easily removed after treatment on the device and the cells can be visualized or recovered for additional off-chip analysis. A 0.4 µm membrane with cell monolayers proved most effective in maintaining separate fluid flows, allowing apical and basal surfaces to be perfused independently. A panel of different cell lines (Caco-2, HT29-MTX-E12, SH-SY5Y, and HUVEC) were successfully maintained in the MPS for up to 7 days, either alone or on devices connected in series. The presence of tight junctions and mucin was expressed as expected by Caco-2 and HT-29-MTX-E12, with Concanavalin A showing uniform staining. Addition of Annexin V and PI showed viability of these cells to be >80% at 7 days. Bacterial extracellular vesicles (BEVs) produced by Bacteroides thetaiotaomicron and labeled with 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbo-cyanine perchlorate (DiD) were used as a model component of the human colonic microbiota and were visualized translocating from an apical surface containing Caco-2 cells to differentiated SH-SY5Y neuronal cells cultured on the basal surface of connected devices. The newly described MPS can be easily adapted, by changing the carrier to maintain spheroids, pieces, or slices of biopsy tissue and joined in series to study a variety of cell and tissue processes. The cell layers can be made more complex through the addition of multiple cell types and/or different patterning of extracellular matrix and the ability to culture cells adjacent to one another to allow study of cell:cell transfer, e.g., passive or active drug transfer, virus or bacterial entry or BEV uptake and transfer.

2.
Talanta Open ; 6: 100166, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36406953

RESUMEN

In response to the ongoing coronavirus disease 2019 (COVID-19) pandemic and disparities of vaccination coverage in low-and middle-income countries, it is vital to adopt a widespread testing and screening programme, combined with contact tracing, to monitor and effectively control the infection dispersion in areas where medical resources are limited. This work presents a lab-on-a-chip device, namely 'IFAST-LAMP-CRISPR', as an affordable, rapid and high-precision molecular diagnostic means for detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). The herein proposed 'sample-to-answer' platform integrates RNA extraction, amplification and molecular detection with lateral flow readout in one device. The microscale dimensions of the device containing immiscible liquids, coupled with the use of silica paramagnetic beads and guanidine hydrochloride, streamline sample preparation (including RNA extraction, concentration and purification) in 15 min with minimal hands-on steps. The pre-amplification in combination with CRISPR-Cas12a detection assays targeting the nucleoprotein (N) gene achieved visual identification of ≥ 470 copies mL-1 genomic SARS-CoV-2 samples in 45 min. On-chip assays showed the ability to isolate and detect SARS-CoV-2 RNA from 100 genome copies mL-1 of replication-deficient viral particles in 1 h. This simple, affordable and integrated platform demonstrated a visual, faster, and yet specificity- and sensitivity-comparable alternative to the costly gold-standard reverse transcription-polymerase chain reaction (RT-PCR) assay, requiring only a simple heating source. Initial testing illustrates the platform viability both on nasopharyngeal swab and saliva samples collected using the easily accessible Swan-brand cigarette filter, providing a complete workflow for COVID-19 diagnostics in low-resource settings.

3.
Anal Chim Acta ; 1177: 338758, 2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34482896

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused the unprecedented global pandemic of coronavirus disease-2019 (COVID-19). Efforts are needed to develop rapid and accurate diagnostic tools for extensive testing, allowing for effective containment of the infection via timely identification and isolation of SARS-CoV-2 carriers. Current gold standard nucleic acid tests require many separate steps that need trained personnel to operate specialist instrumentation in laboratory environments, hampering turnaround time and test accessibility, especially in low-resource settings. We devised an integrated on-chip platform coupling RNA extraction based on immiscible filtration assisted by surface tension (IFAST), with RNA amplification and detection via colorimetric reverse-transcription loop mediated isothermal amplification (RT-LAMP), using two sets of primers targeting open reading frame 1a (ORF1a) and nucleoprotein (N) genes of SARS-CoV-2. Results were identified visually, with a colour change from pink to yellow indicating positive amplification, and further confirmed by DNA gel electrophoresis. The specificity of the assay was tested against HCoV-OC43 and H1N1 RNAs. The assay based on use of gene N primers was 100% specific to SARS-CoV-2 with no cross-reactivity to HCoV-OC43 nor H1N1. Proof-of-concept studies on water and artificial sputum containing genomic SARS-CoV-2 RNA showed our IFAST RT-LAMP device to be capable of extracting and detecting 470 SARS-CoV-2 copies mL-1 within 1 h (from sample-in to answer-out). IFAST RT-LAMP is a simple-to-use, integrated, rapid and accurate COVID-19 diagnostic platform, which could provide an attractive means for extensive screening of SARS-CoV-2 infections at point-of-care, especially in resource-constrained settings.


Asunto(s)
COVID-19 , Dispositivos Laboratorio en un Chip , ARN Viral , COVID-19/diagnóstico , Humanos , Subtipo H1N1 del Virus de la Influenza A , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/aislamiento & purificación , SARS-CoV-2 , Sensibilidad y Especificidad
4.
Electrophoresis ; 42(21-22): 2246-2255, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34031893

RESUMEN

Early detection of pathogenic microorganisms is pivotal to diagnosis and prevention of health and safety crises. Standard methods for pathogen detection often rely on lengthy culturing procedures, confirmed by biochemical assays, leading to >24 h for a diagnosis. The main challenge for pathogen detection is their low concentration within complex matrices. Detection of blood-borne pathogens via techniques such as PCR requires an initial positive blood culture and removal of inhibitory blood components, reducing its potential as a diagnostic tool. Among different label-free microfluidic techniques, inertial focusing on microscale channels holds great promise for automation, parallelization, and passive continuous separation of particles and cells. This work presents inertial microfluidic manipulation of small particles and cells (1-10 µm) in curved serpentine glass channels etched at different depths (deep and shallow designs) that can be exploited for (1) bacteria preconcentration from biological samples and (2) bacteria-blood cell separation. In our shallow device, the ability to focus Escherichia coli into the channel side streams with high recovery (89% at 2.2× preconcentration factor) could be applied for bacteria preconcentration in urine for diagnosis of urinary tract infections. Relying on differential equilibrium positions of red blood cells and E. coli inside the deep device, 97% red blood cells were depleted from 1:50 diluted blood with 54% E. coli recovered at a throughput of 0.7 mL/min. Parallelization of such devices could process relevant volumes of 7 mL whole blood in 10 min, allowing faster sample preparation for downstream molecular diagnostics of bacteria present in bloodstream.


Asunto(s)
Escherichia coli , Microfluídica , Bacterias , Células Sanguíneas , Separación Celular
5.
Behav Genet ; 45(1): 106-16, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25218559

RESUMEN

The difference between Apolipoprotein E ε4 carriers and non-carriers in response to single exercise sessions was tested. Stroop and Posner tasks were administered to young untrained women immediately after walking sessions or moderately heavy exercise. Exercise had a significantly more profound impact on the Stroop effect than on the Posner effect, suggesting selective involvement of prefrontal function. A significant genotype-by-exercise interaction indicated differences in response to exercise between ε4 carriers and non-carriers. Carriers showed facilitation triggered by exercise. The transient executive down-regulation was construed as due to exercise-dependent hypofrontality. The facilitation observed in carriers was interpreted as better management of prefrontal metabolic resources, and explained within the antagonistic pleiotropy hypothesis framework. The findings have implications for the interpretation of differences between ε4 carriers and non-carriers in the benefits triggered by long-term exercise that might depend, at least partially, on mechanisms of metabolic response to physical activity.


Asunto(s)
Alelos , Apolipoproteína E4/genética , Ejercicio Físico , Corteza Prefrontal/fisiología , Adolescente , Adulto , Atención , Cognición , Prueba de Esfuerzo , Femenino , Estudios de Asociación Genética , Genotipo , Humanos , Percepción , Procesamiento Espacial , Test de Stroop , Adulto Joven
6.
Lab Invest ; 93(8): 961-6, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23711823

RESUMEN

This paper describes the development of a microfluidic methodology, using RNA extraction and reverse transcription PCR, for investigating expression levels of cytochrome P450 genes. Cytochrome P450 enzymes are involved in the metabolism of xenobiotics, including many commonly prescribed drugs, therefore information on their expression is useful in both pharmaceutical and clinical settings. RNA extraction, from rat liver tissue or primary rat hepatocytes, was performed using a silica-based solid-phase extraction technique. Following elution of the purified RNA, amplification of target sequences for the housekeeping gene, glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and the cytochrome P450 gene CYP1A2, was carried out using a one-step reverse transcription PCR. Once the microfluidic methodology had been optimized, analysis of control and 3-methylcholanthrene-induced primary rat hepatocytes were used to evaluate the system. As expected, GAPDH was consistently expressed, whereas CYP1A2 levels were found to be raised in the drug-treated samples. The proposed system offers an initial platform for development of both rapid throughput analyzers for pharmaceutical drug screening and point-of-care diagnostic tests to aid provision of drug regimens, which can be tailor-made to the individual patient.


Asunto(s)
Técnicas Analíticas Microfluídicas/métodos , ARN/aislamiento & purificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Animales , Citocromo P-450 CYP1A2/genética , Expresión Génica , Regulación Enzimológica de la Expresión Génica , Gliceraldehído-3-Fosfato Deshidrogenasas/genética , Hepatocitos/química , Hígado/química , Masculino , Técnicas Analíticas Microfluídicas/instrumentación , Ratas , Ratas Wistar
7.
Org Lett ; 14(22): 5724-7, 2012 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-23130671

RESUMEN

A glass microfluidic device has been functionalized with photoactive porphyrins for performing reactions which are mediated by singlet molecular oxygen. The resulting device was used to investigate the photochemical oxidation of cholesterol, α-terpinene, and citronellol under flow conditions, and the results were compared with similar batch reactions.

8.
Ann Biomed Eng ; 40(6): 1277-88, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21997391

RESUMEN

Tumors are heterogeneous masses of cells characterized pathologically by their size and spread. Their chaotic biology makes treatment of malignancies hard to generalize. We present a robust and reproducible glass microfluidic system, for the maintenance and "interrogation" of head and neck squamous cell carcinoma (HNSCC) tumor biopsies, which enables continuous media perfusion and waste removal, recreating in vivo laminar flow and diffusion-driven conditions. Primary HNSCC or metastatic lymph samples were subsequently treated with 5-fluorouracil and cisplatin, alone and in combination, and were monitored for viability and apoptotic biomarker release 'off-chip' over 7 days. The concentration of lactate dehydrogenase was initially high but rapidly dropped to minimally detectable levels in all tumor samples; conversely, effluent concentration of WST-1 (cell proliferation) increased over 7 days: both factors demonstrating cell viability. Addition of cell lysis reagent resulted in increased cell death and reduction in cell proliferation. An apoptotic biomarker, cytochrome c, was analyzed and all the treated samples showed higher levels than the control, with the combination therapy showing the greatest effect. Hematoxylin- and Eosin-stained sections from the biopsy, before and after maintenance, demonstrated the preservation of tissue architecture. This device offers a novel method of studying the tumor environment, and offers a pre-clinical model for creating personalized treatment regimens.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/farmacología , Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Técnicas Analíticas Microfluídicas , Apoptosis/efectos de los fármacos , Biopsia , Carcinoma de Células Escamosas/tratamiento farmacológico , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patología , Proliferación Celular/efectos de los fármacos , Cisplatino/farmacología , Citocromos c/metabolismo , Femenino , Fluorouracilo/farmacología , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Neoplasias de Cabeza y Cuello/metabolismo , Neoplasias de Cabeza y Cuello/mortalidad , Humanos , Hidroliasas/metabolismo , Metástasis Linfática , Masculino , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Proteínas de Neoplasias/metabolismo , Células Tumorales Cultivadas
9.
Electrophoresis ; 32(22): 3188-95, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22025027

RESUMEN

Microflow cytometry represents a promising tool for the investigation of diagnostic and prognostic cellular cancer markers, particularly if integrated within a device that allows primary cells to be freshly isolated from the solid tumour biopsies that more accurately reflect patient-specific in vivo tissue microenvironments at the time of staining. However, current tissue processing techniques involve several sequential stages with concomitant cell losses, and as such are inappropriate for use with small biopsies. Accordingly, we present a simple method for combined antibody-labelling and dissociation of heterogeneous cells from a tumour mass, which reduces the number of processing steps. Perfusion of ex vivo tissue at 4°C with antibodies and enzymes slows cellular activity while allowing sufficient time for the diffusion of minimally active enzymes. In situ antibody-labelled cells are then dissociated at 37°C from the tumour mass, whereupon hydrogel-filled channels allow the release of relatively low cell numbers (<1000) into a biomimetic microenvironment. This novel approach to sample processing is then further integrated with hydrogel-based electrokinetic transport of the freshly liberated fluorescent cells for downstream detection. It is anticipated that this integrated microfluidic methodology will have wide-ranging biomedical and clinical applications.


Asunto(s)
Biomarcadores de Tumor/análisis , Separación Celular/instrumentación , Técnicas Electroquímicas/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Análisis de la Célula Individual/instrumentación , Anticuerpos/química , Biopsia/métodos , Línea Celular Tumoral , Separación Celular/métodos , Técnicas Electroquímicas/métodos , Diseño de Equipo , Colorantes Fluorescentes/química , Neoplasias de Cabeza y Cuello/química , Neoplasias de Cabeza y Cuello/patología , Histocitoquímica , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Técnicas Analíticas Microfluídicas/métodos , Análisis de la Célula Individual/métodos
10.
Lab Chip ; 11(3): 443-8, 2011 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-21072429

RESUMEN

Integrated DNA extraction and amplification have been carried out in a microfluidic device using electro-osmotic pumping (EOP) for fluidic control. All the necessary reagents for performing both DNA extraction and polymerase chain reaction (PCR) amplification were pre-loaded into the microfluidic device following encapsulation in agarose gel. Buccal cells were collected using OmniSwabs [Whatman™, UK] and manually added to a chaotropic binding/lysis solution pre-loaded into the microfluidic device. The released DNA was then adsorbed onto a silica monolith contained within the DNA extraction chamber and the microfluidic device sealed using polymer electrodes. The washing and elution steps for DNA extraction were carried out using EOP, resulting in transfer of the eluted DNA into the PCR chamber. Thermal cycling, achieved using a Peltier element, resulted in amplification of the Amelogenin locus as confirmed using conventional capillary gel electrophoresis. It was demonstrated that the PCR reagents could be stored in the microfluidic device for at least 8 weeks at 4 °C with no significant loss of activity. Such methodology lends itself to the production of 'ready-to-use' microfluidic devices containing all the necessary reagents for sample processing, with many obvious applications in forensics and clinical medicine.


Asunto(s)
ADN/aislamiento & purificación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Extracción en Fase Sólida/métodos , Amelogenina/genética , Electroforesis Capilar/métodos , Geles/química , Humanos , Reacción en Cadena de la Polimerasa , Polímeros , Dióxido de Silicio/química
11.
Lab Chip ; 10(20): 2720-6, 2010 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-20721382

RESUMEN

A microfluidic device has been developed to maintain viable heart tissue samples in a biomimetic microenvironment. This device allows rat or human heart tissue to be studied under pseudo in vivo conditions. Effluent levels of lactate dehydrogenase and hydrogen peroxide were used as markers of damaged tissue in combination with in situ electrochemical measurement of the release of reactive oxygen species (ROS). The parameters for perfusion were optimized to maintain biopsies of rat right ventricular or human right atrial tissue viable for up to 5 and 3.5 hours, respectively. Electrochemical assessment of the oxidation current of total ROS, employing cyclic voltammetry, gave results in real-time that were in good agreement to biochemical assessment using conventional, off-chip, commercial assays. This proof-of-principle, integrated microfluidic device, may be exploited in providing a platform technology for future cardiac research, offering an alternative approach for investigating heart pathophysiology and facilitating the development of new therapeutic strategies.


Asunto(s)
Electroquímica/instrumentación , Corazón Auxiliar , Bombas de Infusión , Técnicas Analíticas Microfluídicas/instrumentación , Especies Reactivas de Oxígeno/sangre , Animales , Sistemas de Computación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Técnicas In Vitro , Ratas , Ratas Wistar
12.
Lab Chip ; 10(13): 1725-8, 2010 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-20414500

RESUMEN

A microwave heating system is described for performing polymerase chain reaction (PCR) in a microfluidic device. The heating system, in combination with air impingement cooling, provided rapid thermal cycling with heating and cooling rates of up to 65 degrees C s(-1) and minimal over- or under-shoot (+/-0.1 degrees C) when reaching target temperatures. In addition, once the required temperature was reached it could be maintained with an accuracy of +/-0.1 degrees C. To demonstrate the functionality of the system, PCR was successfully performed for the amplification of the Amelogenin locus using heating rates and quantities an order of magnitude faster and smaller than current commercial instruments.


Asunto(s)
Calefacción/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Termografía/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Microondas
13.
Analyst ; 135(2): 302-5, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20098762

RESUMEN

A novel method to determine nitric oxide (NO) in biological tissue samples with minimal interference from the cellular detritus is described. Methylpiperazinobenzenediamine, consisting of an o-phenylenediamine and a methyl piperazine group, was chosen as a probe for the detection of NO by mass spectrometry (MS) in biological tissue samples. The o-phenylenediamine group reacts with NO to form a characteristic benzotriazole. The product was identified using electrospray ionization mass spectrometry (ESI-MS) and the method validated within the range of 95-1900 nM. NO levels associated with tissue biopsies (approximately 10 mg) from rat vasculature and intestine tissue biopsies have been successfully determined. The different rates of NO generated from tissue samples under hypoxic and normoxic conditions have been studied by this simple and sensitive method.


Asunto(s)
Aorta/metabolismo , Mucosa Intestinal/metabolismo , Óxido Nítrico/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Aorta/citología , Hipoxia , Intestinos/citología , Fenilendiaminas/química , Ratas , Ratas Wistar
14.
Lab Chip ; 9(23): 3430-2, 2009 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-19904411

RESUMEN

A novel DNA loading methodology is presented for performing DNA extraction on a microfluidic system. DNA in a chaotropic salt solution was manually loaded onto a silica monolith orthogonal to the subsequent flow of wash and elution solutions. DNA was successfully extracted from buccal swabs using electro-osmotic pumping (EOP) coupled with in situ reagents contained within a 1.5% agarose gel matrix. The extracted DNA was of sufficient quantity and purity for polymerase chain reaction (PCR) amplification.


Asunto(s)
ADN/aislamiento & purificación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Femenino , Humanos , Técnicas Analíticas Microfluídicas/economía , Mucosa Bucal/citología , Reacción en Cadena de la Polimerasa , Dióxido de Silicio/química , Manejo de Especímenes/economía , Manejo de Especímenes/instrumentación
15.
Anal Chim Acta ; 652(1-2): 231-3, 2009 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-19786185

RESUMEN

DNA extraction was carried out on silica-based monoliths within a microfluidic device. Solid-phase DNA extraction methodology was applied in which the DNA binds to silica in the presence of a chaotropic salt, such as guanidine hydrochloride, and is eluted in a low ionic strength solution, such as water. The addition of poly-A carrier RNA to the chaotropic salt solution resulted in a marked increase in the effective amount of DNA that could be recovered (25ng) compared to the absence of RNA (5ng) using the silica-based monolith. These findings confirm that techniques utilising nucleic acid carrier molecules can enhance DNA extraction methodologies in microfluidic applications.


Asunto(s)
ADN/aislamiento & purificación , Técnicas Analíticas Microfluídicas/métodos , ARN/química , Dióxido de Silicio/química , Técnicas Analíticas Microfluídicas/instrumentación , Extracción en Fase Sólida
16.
Anal Chim Acta ; 652(1-2): 239-44, 2009 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-19786187

RESUMEN

An integrated gel supported micro-fluidic system is reported, in which PCR products can be efficiently injected into a capillary electrophoresis device. The gel supported system is designed to provide greater stability to reagents during long periods of dormancy, enabling the mass production of one use chips encapsulating all required reagents at the time of manufacturing. This simultaneously diminishes the risk of sample contamination, and reduces the amount of external hardware required for auxiliary flow control, thus increasing the potential for portability. After PCR amplification was performed in a polysaccharide gel matrix, the PCR product was injected into the separation gel polymer matrix by executing a capillary-based electro-kinetic pinched injection across a gel-to-gel interface. The gel-to-gel system delivered a precise and accurate plug into the separation polymer, which offered more stable electro-kinetic control of the sample compared to solution based methodology even when bubbles were present in the system. Suitable voltage control was proven to provide a repeatable electro-kinetic injection of PCR product sufficient for an on-chip separation of multiple loci by capillary electrophoresis.


Asunto(s)
ADN/análisis , Electroforesis Capilar/instrumentación , Geles/química , Técnicas Analíticas Microfluídicas/instrumentación , ADN/aislamiento & purificación , Electroforesis Capilar/métodos , Cinética , Técnicas Analíticas Microfluídicas/métodos
17.
Lab Chip ; 9(11): 1596-600, 2009 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-19458868

RESUMEN

A silica monolith used to support both electro-osmotic pumping (EOP) and the extraction/elution of DNA coupled with gel-supported reagents is described. The benefits of the combined EOP extraction/elution system were illustrated by combining DNA extraction and gene amplification using the polymerase chain reaction (PCR) process. All the reagents necessary for both processes were supported within pre-loaded gels that allow the reagents to be stored at 4 degrees C for up to four weeks in the microfluidic device. When carrying out an analysis the crude sample only needed to be hydrodynamically introduced into the device which was connected to an external computer controlled power supply via platinum wire electrodes. DNA was extracted with 65% efficiency after loading lysed cells onto a silica monolith. Ethanol contained within an agarose gel matrix was then used to wash unwanted debris away from the sample by EOP (100 V cm(-1) for 5 min). The retained DNA was subsequently eluted from the monolith by water contained in a second agarose gel, again by EOP using an electric field of 100 V cm(-1) for 5 min, and transferred into the PCR reagent containing gel. The eluted DNA in solution was successfully amplified by PCR, confirming that the concept of a complete self-contained microfluidic device could be realised for DNA sample clean up and amplification, using a simple pumping and on-chip reagent storage methodology.


Asunto(s)
ADN/aislamiento & purificación , Electroósmosis/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Amelogenina/genética , Electroósmosis/métodos , Diseño de Equipo , Etanol/química , Geles/química , Humanos , Técnicas Analíticas Microfluídicas/métodos , Reacción en Cadena de la Polimerasa , Dióxido de Silicio/química
18.
Lab Chip ; 8(11): 1842-6, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18941683

RESUMEN

A microfluidic based experimental methodology has been developed that offers a biomimetic microenvironment in which pseudo in vivo tissue studies can be carried out under in vitro conditions. Using this innovative technique, which utilizes the inherent advantages of microfluidic technology, liver tissue has been kept in a viable and functional state for over 70 h during which time on-chip cell lysis has been repeatedly performed. Tissue samples were also disaggregated in situ on-chip into individual primary cells, using a collagenase digestion procedure, enabling further cell analysis to be carried out off-line. It is anticipated that this methodology will have a wide impact on biological and clinical research in fields such as cancer prognosis and treatment, drug development and toxicity, as well as enabling better fundamental research into tissue/cell processes.


Asunto(s)
Microfluídica/instrumentación , Animales , Biomimética , Biopsia , Bovinos , Supervivencia Celular , Colagenasas/metabolismo , Hígado/citología , Hígado/metabolismo , Masculino , Ratas
19.
Cancer Immunol Immunother ; 55(11): 1301-8, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16453151

RESUMEN

AIMS: The association between tissue factor (TF) expression and increased rate of tumour metastasis is well established. In this study, we have examined the hypothesis that the expression of TF by disseminated tumour cells confers protection against immune recognition and cytotoxicity. MATERIALS AND METHODS: A hybrid EGFP-TF protein was expressed in HT29 colon carcinoma and K562 lymphoblast cell lines. To assess the cytotoxic activity against tumour cells over-expressing TF, a novel method was used, based on the direct measurement of fluorescently labelled HT29 or K562 target cells. RESULTS: Upon challenge with peripheral blood mononuclear cells (PBMC), tumour cells expressing TF partially evaded cellular cytotoxicity (Delta=15-40% reduction in cytotoxicity). Moreover, the influence of TF was not primarily dependent on its procoagulant function, although the inclusion of 20% (v/v) plasma did lower the rate of cytotoxicity against untransfected cells. However, expression of a truncated form of TF, devoid of the cytoplasmic domain, did not mediate any degree of inhibition of cytotoxicity, suggesting that the protective function of TF is principally due to this domain. CONCLUSIONS: We conclude that TF can promote immune evasion in tumour cells expressing this protein leading to increased survival and therefore metastatic rate in such cells.


Asunto(s)
Neoplasias Colorrectales/metabolismo , Regulación Neoplásica de la Expresión Génica , Linfocitos/metabolismo , Tromboplastina/fisiología , Línea Celular Tumoral , Neoplasias Colorrectales/patología , Citoplasma/metabolismo , Humanos , Células K562 , Leucocitos Mononucleares/metabolismo , Metástasis de la Neoplasia , Estructura Terciaria de Proteína , Tiempo de Protrombina , Tromboplastina/biosíntesis , Tromboplastina/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...