Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 16739, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37798351

RESUMEN

The exploration of the chiral configurations of enantiomers represents a highly intriguing realm of scientific inquiry due to the distinct roles played by each enantiomer (D and L) in chemical reactions and their practical utilities. This study introduces a pioneering analytical methodology, termed fast Fourier transform capacitance voltammetry (FFT-CPV), in conjunction with principal component analysis (PCA), for the identification and quantification of the chiral forms of tartaric acid (TA), serving as a representative model system for materials exhibiting pronounced chiral characteristics. The proposed methodology relies on the principle of chirality, wherein the capacitance signal generated by the adsorption of D-TA and L-TA onto the surface of a platinum electrode (Pt-electrode) in an acidic solution is harnessed. The capacitance voltammograms were meticulously recorded under optimized experimental conditions. To compile the final dataset for the analyte, the average of the FFT capacitance voltammograms of the acidic solution (without the presence of the analyte) was subtracted from those containing the analyte. A distinct arrangement was obtained by employing PCA as a linear data transformation method, representing D-TA and L-TA in a two/three-dimensional space. The outcomes of the study reveal the successful detection of the two chiral forms of TA with a considerable degree of precision and reproducibility. Moreover, the proposed method facilitated the establishment of two linear response ranges for the concentration values of each enantiomer, spanning from 1 to 20 µM, and 50 to 500 µM. The respective detection limits were also determined to be 0.4 µM for L-TA and 1.3 µM for D-TA. These findings underscore the satisfactory sensitivity and efficiency of the proposed method in both qualitative and quantitative assessments of the chiral forms of TA.

2.
Int J Biol Macromol ; 189: 802-818, 2021 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-34418419

RESUMEN

COVID-19 disease has put life of people in stress worldwide from many aspects. Since the virus has mutated in absolutely short period of time the challenge to find a suitable vaccine has become harder. Infection to COVID-19, especially at severe life threatening states is highly dependent on the strength of the host immune system. This system is partially dependent on the balance between oxidative stress and antioxidant. Besides, this virus still has unknown mechanism of action companied by a probable commune period. From another hand, some reactive oxygen species (ROS) levels can be helpful on the state determination of the disease. Thus it could be possible to use modern bioanalytical techniques for their detection and determination, which could indicate the disease state at the golden time window since they have the potential to show whether specific DNA, RNA, enzymes and proteins are affected. This also could be used as a preclude study or a reliable pathway to define the best optimized time of cure beside effective medical actions. Herein, some ROS and their relation with SARS-CoV-2 virus have been considered. In addition, modern bioelectroanalytical techniques on this approach from quantitative and qualitative points of view have been reviewed.


Asunto(s)
Antioxidantes/metabolismo , COVID-19/metabolismo , Estrés Oxidativo , Especies Reactivas de Oxígeno/metabolismo , SARS-CoV-2/metabolismo , COVID-19/terapia , Humanos
3.
Anal Biochem ; 566: 102-106, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30468717

RESUMEN

Here, the construction and characterization of the first immunosensor for highly sensitive and label free detection of Fig mosaic virus (FMV) is reported. The specific antibody against nucleocapsid of the virus was raised and immobilized at the surface of 11-mercaptoundecanoic acid (MUA) and 3-mercapto propionic acid (MPA) modified gold electrode, via carbodiimide coupling reaction. The immunosensor fabrication steps were characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical detection of FMV was conducted using differential pulse voltammetry in ferri/ferrocyanide solution as a redox probe. The proposed immunosensor exhibited high selectivity, good reproducibility and high sensitivity for FMV detection in a range from 0.1 nM to 1 µM with a detection limit of 0.03 nM. Moreover, good results were obtained for determination of FMV in real samples, indicating the feasibility of the developed immunosensor for detection of fig mosaic disease, without the need for molecular (e.g. PCR) amplification.


Asunto(s)
Técnicas Biosensibles/métodos , Espectroscopía Dieléctrica/métodos , Ficus/virología , Inmunoensayo/métodos , Virus de Plantas/aislamiento & purificación , Ácido 3-Mercaptopropiónico , Anticuerpos Inmovilizados/química , Técnicas Electroquímicas/métodos , Electrodos , Alcoholes Grasos/química , Oro/química , Límite de Detección , Oxidación-Reducción , Virus de Plantas/química , Virus de Plantas/inmunología , Compuestos de Sulfhidrilo/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...