Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Am Coll Cardiol ; 76(12): 1468-1483, 2020 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-32943165

RESUMEN

Investigating the balance of risk for thrombotic and bleeding events after percutaneous coronary intervention (PCI) is especially relevant for patients at high bleeding risk (HBR). The Academic Research Consortium for HBR recently proposed a consensus definition in an effort to standardize the patient population included in HBR trials. The aim of this consensus-based document, the second initiative from the Academic Research Consortium for HBR, is to propose recommendations to guide the design of clinical trials of devices and drugs in HBR patients undergoing PCI. The authors discuss the designs of trials in HBR patients undergoing PCI and various aspects of trial design specific to HBR patients, including target populations, intervention and control groups, primary and secondary outcomes, and timing of endpoint reporting.


Asunto(s)
Ensayos Clínicos como Asunto , Hemorragia , Intervención Coronaria Percutánea , Humanos , Evaluación de Resultado en la Atención de Salud
2.
Circulation ; 140(3): 240-261, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31116032

RESUMEN

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Asunto(s)
Congresos como Asunto , Consenso , Hemorragia/diagnóstico , Hemorragia/etiología , Intervención Coronaria Percutánea/efectos adversos , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Congresos como Asunto/tendencias , District of Columbia , Hemorragia/prevención & control , Humanos , Paris , Intervención Coronaria Percutánea/tendencias , Medición de Riesgo/métodos
3.
Eur Heart J ; 40(31): 2632-2653, 2019 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31116395

RESUMEN

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Asunto(s)
Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/efectos adversos , Hemorragia/etiología , Intervención Coronaria Percutánea/efectos adversos , Stents/efectos adversos , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/epidemiología , Síndrome Coronario Agudo/fisiopatología , Anciano , Anciano de 80 o más Años , Anemia/complicaciones , Anemia/epidemiología , Anemia/fisiopatología , Asia/epidemiología , Toma de Decisiones Clínicas , Ensayos Clínicos como Asunto , Consenso , Europa (Continente)/epidemiología , Fibrosis/complicaciones , Fragilidad/complicaciones , Fragilidad/epidemiología , Fragilidad/fisiopatología , Hemorragia/epidemiología , Humanos , Hipertensión Portal/epidemiología , Hipertensión Portal/fisiopatología , Cumplimiento de la Medicación/estadística & datos numéricos , Metales , Intervención Coronaria Percutánea/instrumentación , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/epidemiología , Insuficiencia Renal Crónica/fisiopatología , Medición de Riesgo , Seguridad , Trombocitopenia/complicaciones , Trombocitopenia/epidemiología , Trombocitopenia/fisiopatología , Resultado del Tratamiento , Estados Unidos/epidemiología
4.
EuroIntervention ; 14(4): e418-e425, 2018 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-29790477

RESUMEN

AIMS: The LEADERS FREE trial has demonstrated that a polymer-free Biolimus A9-coated stent (BA9-DCS) is superior to a bare metal stent (BMS) for high bleeding risk (HBR) patients when treated with one month of dual antiplatelet therapy (DAPT). This analysis aimed to determine the impact of PCI procedure complexity on the two-year results. METHODS AND RESULTS: Six hundred and sixty-seven (667) patients enrolled in the LEADERS FREE (BA9-DCS 346, BMS 321) underwent a complex PCI, defined by one or more of eight characteristics: total stent length ≥60 mm, ≥3 vessels or lesions treated, ≥3 stents implanted, bifurcation lesion treated with ≥2 stents, chronically occluded, restenotic or saphenous vein graft lesion. Patients undergoing complex PCI were older, more often male, and presented with more ACS, diabetes, renal insufficiency, anaemia and multivessel disease. They derived major benefit from DCS over BMS for safety (16.2% vs. 21.7%, HR 0.70 [0.49-0.99], p<0.05) and for efficacy (10.8% vs. 18.1%, HR 0.54 [0.35-0.83], p<0.005). For the 1,746 patients with non-complex PCI, DCS demonstrated superior efficacy (5.3% vs. 9.9%, HR 0.52 [0.36-0.75], p<0.001, p for interaction NS) and similar safety to BMS (11.1% vs. 12.6%, NS, p for interaction NS). CONCLUSIONS: Compared to BMS, the BA9-DCS maintained both efficacy and safety benefits when used in complex PCI procedures.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Masculino , Inhibidores de Agregación Plaquetaria , Polímeros , Sirolimus/análogos & derivados , Resultado del Tratamiento
5.
Cardiol J ; 23(6): 626-636, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27665852

RESUMEN

BACKGROUND: Few data are available on long-term follow-up of drug-eluting stents in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES). METHODS: Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 with CTOs were treated with either a BES (n = 45) or a SES (n = 36). The primary endpoint was the occurrence of major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI) and clinically-indicated target vessel revascularization (TVR). RESULTS: At 5 years, the rate of MACE was numerically higher in the CTO group than in the non-CTO group (29.6% vs. 23.3%; p = 0.173), with a significant increase in the incidence of target lesion revascularization (TLR) (21.0 vs. 12.6; p = 0.033), but no difference in stent thrombosis (ST). Patients with CTO receiving a BES demonstrated a lower incidence of MACE (22.2% vs. 38.9%; p = 0.147) with a significant reduction in TLR compared to patients receiving a SES (11.1% vs. 33.3%, p = 0.0214) with an incidence similar to that observed in the non-CTO group treated with BES (11.6%). Definite ST at 5 years nearly halved in the BES group (4.4% vs. 8.3%, p = 0.478) with no ST in the BES group after the first year (0% vs. 8.3%, p for interaction = 0.009). CONCLUSIONS: The use of a BES showed a reduction in MACE, TVR, TLR, and ST over time in the CTO subset with similar outcome as for non-CTO lesions.


Asunto(s)
Implantes Absorbibles , Oclusión Coronaria/cirugía , Stents Liberadores de Fármacos , Polímeros , Sirolimus/análogos & derivados , Sirolimus/farmacología , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 86(7): 1151-60, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25683225

RESUMEN

OBJECTIVES: To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice. BACKGROUND: The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent. METHODS: 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years. RESULTS: Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST. CONCLUSIONS: This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Comorbilidad , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Quimioterapia Combinada , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Modelos de Riesgos Proporcionales , Sistema de Registros , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
7.
Heart ; 101(4): 271-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25423953

RESUMEN

OBJECTIVE: To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS: The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. RESULTS: The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. CONCLUSIONS: BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up. TRIAL REGISTRATION NUMBER: NCT 00389220.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/análogos & derivados , Anciano , Angiografía Coronaria , Trombosis Coronaria/etiología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Recurrencia , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
8.
JACC Cardiovasc Interv ; 6(8): 777-89, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23968698

RESUMEN

OBJECTIVES: This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND: The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS: The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS: At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS: The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/análogos & derivados , Anciano , Distribución de Chi-Cuadrado , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
9.
Lancet ; 378(9807): 1940-8, 2011 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-22075451

RESUMEN

BACKGROUND: The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. METHODS: We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049). INTERPRETATION: Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. FUNDING: Biosensors Europe SA, Switzerland.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Polímeros , Sirolimus/análogos & derivados , Estudios de Seguimiento , Humanos , Trombosis/etiología
10.
EuroIntervention ; 6(8): 928-35, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21330239

RESUMEN

AIMS: This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer. METHODS AND RESULTS: The clinical outcomes were assessed in the 497 patients (BES 258, SES 239) enrolled in the multicentre, randomised LEADERS trial who underwent treatment of ≥1 BL (total=534 BL). At 12-months follow-up there was no significant difference in the primary endpoint of MACE, a composite of cardiac death, myocardial infarction and clinically indicated target vessel revascularisation (BES 12.8% vs. SES 16.3%, p=0.31). Patients treated with BES had comparable rates of cardiac death (BES 2.7% vs. SES 2.9%, p=1.00), numerically higher rates of myocardial infarction (BES 8.9% vs. SES 5.4%, p=0.17), and significantly lower rates of clinically indicated target vessel revascularisation (4.3% vs. 11.3%, p=0.004) when compared to those treated with SES. The rate of stent thrombosis at 12-months was 4.3% and 3.8% for BES and SES, respectively (p=0.82). CONCLUSIONS: In the treatment of BL the use of BES lead to superior efficacy and comparable safety compared to SES.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Implantes Absorbibles/efectos adversos , Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , Anciano , Angioplastia Coronaria con Balón/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia , Polímeros/efectos adversos , Resultado del Tratamiento
11.
EuroIntervention ; 6(2): 233-9, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20562074

RESUMEN

AIMS: This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES). METHODS AND RESULTS: The multicentre LEADERS trial employed an all-comers approach to recruit 1,707 patients who were randomised to treatment with either BES (n=857) or SES (n=850) in a non-inferiority design. The primary clinical endpoint of this study was a composite of cardiac death, myocardial infarction and clinical-indicated target vessel revascularisation. Follow-up was obtained in 97.6% of patients. At 12 months, BES remained non-inferior compared to SES for the primary endpoint (BES 10.6% vs. SES 12.0%, HR:0.88, 95% CI:0.66-1.17, p=0.37). Rates of cardiac death (2.1% vs. 2.7%, HR:0.77, 95% CI:0.42-1.44, p=0.42), MI (5.8% vs. 4.6%, HR:1.27, 95% CI:0.84-1.94, p=0.26) and clinically-indicated target vessel revascularisation (5.8% vs. 7.1%, HR:0.82, 95%CI:0.56-1.19, p=0.29) were similar for BES and SES. Similarly, there was no difference in the incidence of definite stent thrombosis at 12 months. CONCLUSIONS: These findings support the safety and efficacy of the BES stent with a biodegradable polymer at 12-month clinical follow-up, and suggest it is a suitable alternative to the SES stent with a durable polymer.


Asunto(s)
Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Implantes Absorbibles , Femenino , Estudios de Seguimiento , Humanos , Ácido Láctico , Masculino , Persona de Mediana Edad , Poliésteres , Polímeros , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
12.
Am J Cardiol ; 105(4): 475-9, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-20152241

RESUMEN

The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.


Asunto(s)
Angioplastia Coronaria con Balón , Índice de Masa Corporal , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Infarto del Miocardio/terapia , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/mortalidad , Intervalos de Confianza , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Países Bajos , Obesidad/complicaciones , Oportunidad Relativa , Sobrepeso/complicaciones , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Factores de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento
13.
Eur Heart J ; 31(2): 165-76, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19889649

RESUMEN

AIMS: Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. METHODS AND RESULTS: Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01). CONCLUSION: Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined.


Asunto(s)
Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Sirolimus/administración & dosificación , Moduladores de Tubulina/administración & dosificación , Implantes Absorbibles , Reestenosis Coronaria/diagnóstico , Femenino , Oclusión de Injerto Vascular/diagnóstico , Oclusión de Injerto Vascular/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Polímeros , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Resultado del Tratamiento
14.
Lancet ; 372(9644): 1163-73, 2008 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-18765162

RESUMEN

BACKGROUND: A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer). METHODS: We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26). INTERPRETATION: Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes. FUNDING: Biosensors Europe SA, Switzerland.


Asunto(s)
Implantes Absorbibles , Enfermedad Coronaria/terapia , Stents Liberadores de Fármacos , Polímeros , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Implantes Absorbibles/efectos adversos , Anciano , Materiales Biocompatibles/efectos adversos , Enfermedad Crónica , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Ensayo de Materiales , Metales , Persona de Mediana Edad , Polímeros/efectos adversos , Trombosis/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...