Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
ESC Heart Fail ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39379167

RESUMEN

AIMS: Baroreceptor activation therapy (BAT) is a promising new treatment strategy for patients with heart failure with reduced ejection fraction (HFrEF). It provides symptomatic relief, improvement in left ventricular function and reduction of cardiac biomarkers. Data regarding the long-term effect of BAT on HFrEF are scarce. This retrospective, monocentric study aimed to assess long-term outcome in patients who underwent BAT. METHODS: Patients with HFrEF who received BAT at Hannover Medical School between 2014 and 2023 were followed until the latest available follow-up. Symptom burden, echocardiography and laboratory testing were assessed before BAT implantation and in subsequent follow-ups. RESULTS: Twenty-three patients (mean age 66 ± 10 years, 83% male) with HFrEF were included in the study. Aetiology of heart failure was ischaemic in 70%. The majority of patients (96%) suffered from New York Heart Association (NYHA) III with a mean left ventricular ejection fraction (LVEF) of 23 ± 8% and N-terminal pro-B-type natriuretic peptide (NT-proBNP) of 2463 ± 2922 pg/mL. A complication occurred in one patient during BAT implantation (4%). The mean follow-up was 3 ± 2 (max. 7.5) years. BAT reduced NYHA classification in 12 patients (52%) after 1 year, of which one patient remained in ameliorated NYHA for 7.5 years. Echocardiographic evaluation revealed significant improvement in LVEF by 9 ± 9% after 1 year (P < 0.001) and by 11 ± 9% (P = 0.005) after 2 years. In addition, BAT mildly reduced NT-proBNP in the first 2 years [non-significantly after 1 year by 396 ± 1006 pg/mL and significantly after 2 years by 566 ± 651 pg/mL (P = 0.039)]. Seven patients reaching the recommended replacement time underwent device exchange. Four patients died during observation time. CONCLUSIONS: BAT resulted in a substantial reduction in NYHA classification and improvement in LVEF that lasted over long-term follow-up in many patients. NT-proBNP level decreased interim in long-term follow-up. These findings highlight the long-term efficacy and potential benefits of BAT as a therapeutic intervention for patients with HFrEF.

2.
J Pharmacol Toxicol Methods ; 124: 107471, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37690768

RESUMEN

Computer-based analysis of long-term electrocardiogram (ECG) monitoring in animal models represents a cost and time-consuming process as manual supervision is often performed to ensure accuracy in arrhythmia detection. Here, we investigate the performance and feasibility of three ECG interval analysis approaches A) attribute-based, B) attribute- and pattern recognition-based and C) combined approach with additional manual beat-to-beat analysis (gold standard) with regard to subsequent detection of ventricular arrhythmias (VA) and time consumption. ECG analysis was performed on ECG raw data of 5 male cynomolgus monkeys (1000 h total, 2 × 100 h per animal). Both approaches A and B overestimated the total number of arrhythmias compared to gold standard (+8.92% vs. +6.47%). With regard to correct classification of detected VA event numbers (accelerated idioventricular rhythms [AIVR], ventricular tachycardia [VT]) approach B revealed higher accuracy compared to approach A. Importantly, VA burden (% of time) was precisely depicted when using approach B (-1.13%), whereas approach A resulted in relevant undersensing of ventricular arrhythmias (-11.76%). Of note, approach A and B could be performed with significant less working time (-95% and - 91% working time) compared to gold standard. In sum, we show that a combination of attribute-based and pattern recognition analysis (approach B) can reproduce VA burden with acceptable accuracy without using manual supervision. Since this approach allowed analyses to be performed with distinct time saving it represents a valuable approach for cost and time efficient analysis of large preclinical ECG datasets.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Animales , Masculino , Macaca fascicularis , Estudios de Factibilidad , Arritmias Cardíacas/diagnóstico , Computadores
3.
Pacing Clin Electrophysiol ; 46(8): 875-881, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37483154

RESUMEN

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Asunto(s)
Fascículo Atrioventricular Accesorio , Fibrilación Atrial , Ablación por Catéter , Humanos , Estudios Prospectivos , Resultado del Tratamiento , Fibrilación Atrial/cirugía , Fascículo Atrioventricular Accesorio/cirugía , Electrofisiología Cardíaca , Fluoroscopía/métodos , Ablación por Catéter/métodos
4.
PLoS One ; 18(4): e0284419, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37071637

RESUMEN

BACKGROUND: The number of left ventricular assist devices (LVADs) implanted in patients with end-stage heart failure is increasing. In this patient cohort, subcutaneous implantable cardioverter defibrillators (S-ICDs) could be a promising alternative to transvenous ICDs due to lower infection rates and avoidance of venous access. However, eligibility for the S-ICD depends on ECG features that may be influenced by an LVAD. The aim of the present study was a prospective evaluation of S-ICD eligibility before and after LVAD implantation. METHODS: The study recruited all patients presenting at Hannover Medical School for LVAD implantation between 2016 and 2020. S-ICD eligibility was evaluated using the ECG-based and the device-based S-ICD screening test before and after LVAD implantation. RESULTS: Twenty-two patients (57.3 ± 8.7 years of age, 95.5% male) were included in the analysis. The most common underlying diseases were dilated cardiomyopathy (n = 16, 72.7%) and ischemic cardiomyopathy (n = 5, 22.7%). Before LVAD implantation 16 patients were found eligible for the S-ICD according to both screening tests (72.7%), but only 7 patients were eligible after LVAD, 31.8%; p = 0.05). Oversensing due to electromagnetic interference was observed in 6 patients (66.6%) found ineligible for S-ICD after LVAD implantation. A lower S wave amplitude in leads I (p = 0.009), II (p = 0.006) and aVF (p = 0.006) before LVAD implantation was associated with higher rate of S-ICD ineligibility after LVAD implantation. CONCLUSION: LVAD implantation can impair S-ICD eligibility. Patients with lower S wave amplitude in leads I, II and aVF were more likely to be ineligible for S-ICD implantation after LVAD implantation. Thus, S-ICD therapy should be carefully considered in patients who are candidates for LVAD therapy.


Asunto(s)
Desfibriladores Implantables , Corazón Auxiliar , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Corazón Auxiliar/efectos adversos , Cardioversión Eléctrica , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Implantación del Embrión
5.
Sensors (Basel) ; 22(5)2022 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-35271182

RESUMEN

In patients with newly diagnosed heart failure with reduced ejection fraction (HFrEF), three months of optimal therapy are recommended before considering a primary preventive implantable cardioverter-defibrillator (ICD). It is unclear which patients benefit from a prolonged waiting period under protection of the wearable cardioverter-defibrillator (WCD) to avoid unnecessary ICD implantations. This study included all patients receiving a WCD for newly diagnosed HFrEF (n = 353) at our center between 2012 and 2017. Median follow-up was 2.7 years. From baseline until three months, LVEF improved in patients with all peripartum cardiomyopathy (PPCM), myocarditis, dilated cardiomyopathy (DCM), or ischemic cardiomyopathy (ICM). Beyond this time, LVEF improved in PPCM and DCM only (10 ± 8% and 10 ± 12%, respectively), whereas patients with ICM showed no further improvement. The patients with newly diagnosed HFrEF were compared to 29 patients with a distinct WCD indication, which is an explantation of an infected ICD. This latter group had a higher incidence of WCD shocks and poorer overall survival. All-cause mortality should be considered when deciding on WCD prescription. In patients with newly diagnosed HFrEF, the potential for delayed LVEF recovery should be considered when timing ICD implantation, especially in patients with PPCM and DCM.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Humanos , Volumen Sistólico , Función Ventricular Izquierda
6.
Herzschrittmacherther Elektrophysiol ; 33(1): 49-54, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34825951

RESUMEN

Non-invasive stereotactic radioablation of ventricular tachycardia (VT) substrate has been proposed as a novel treatment modality for patients not eligible for catheter-based ablation or in whom this approach has failed. Initial clinical results are promising with good short-term efficacy in VT suppression and tolerable side effects. This article reviews the current clinical evidence for cardiac radioablation and gives an overview of important preclinical and translational results. Practical guidance is provided, and a cardiac radioablation planning and treatment workflow based on expert consensus and the authors' institutional experience is set out.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Arritmias Cardíacas/cirugía , Corazón , Humanos , Imagenología Tridimensional , Taquicardia Ventricular/terapia , Resultado del Tratamiento
7.
Sensors (Basel) ; 21(23)2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34883802

RESUMEN

The wearable cardioverter-defibrillator (WCD) is used in patients with newly diagnosed heart failure and reduced ejection fraction (HFrEF). In addition to arrhythmic events, the WCD provides near-continuous telemetric heart failure monitoring. The purpose of this study was to evaluate the clinical relevance of additionally recorded parameters, such as heart rate or step count. We included patients with newly diagnosed HFrEF prescribed with a WCD. Via the WCD, step count and heart rate were acquired, and an approximate for heart rate variability (HRV5) was calculated. Multivariate analysis was performed to analyze predictors for an improvement in left ventricular ejection fraction (LVEF). Two hundred and seventy-six patients (31.9% female) were included. Mean LVEF was 25.3 ± 8.5%. Between the first and last seven days of usage, median heart rate fell significantly (p < 0.001), while median step count and HRV5 significantly increased (p < 0.001). In a multivariate analysis, a delta of HRV5 > 23 ms was an independent predictor for LVEF improvement of ≥10% between prescription and 3-month follow-up. Patients with newly diagnosed HFrEF showed significant changes in heart rate, step count, and HRV5 between the beginning and end of WCD prescription time. HRV5 was an independent predictor for LVEF improvement and could serve as an early indicator of treatment response.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Dispositivos Electrónicos Vestibles , Muerte Súbita Cardíaca , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Volumen Sistólico , Función Ventricular Izquierda
9.
Herzschrittmacherther Elektrophysiol ; 32(4): 475-478, 2021 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-34643796

RESUMEN

A 35-year-old man experienced respiratory agony while sleeping followed by a generalized seizure. Subsequent exclusively neurological diagnostics showed no pathological findings. Four months later, the patient suffered a sudden cardiac death due to ventricular fibrillation, which he survived without neurological deficit. After initially unremarkable diagnostics, the diagnosis could be made electrocardiographically. Following a special pharmacological therapy, the patient remained free from further episodes of ventricular fibrillation in the long-term follow-up.


Asunto(s)
Síndrome de Brugada , Adulto , Arritmias Cardíacas , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Humanos , Masculino , Fibrilación Ventricular/diagnóstico
10.
ESC Heart Fail ; 8(6): 5142-5148, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34480414

RESUMEN

AIM: The wearable cardioverter-defibrillator (WCD) is used for temporary protection from sudden cardiac death (SCD) in patients with newly diagnosed heart failure with reduced ejection fraction before considering an implantable cardioverter-defibrillator (ICD). However, the prognostic significance of the WCD remains controversial due to conflicting evidence. The aim of the present study was to evaluate prognosis of patients receiving life-saving WCD shocks. METHODS AND RESULTS: All patients receiving a WCD at Hannover Medical School for heart failure with reduced ejection fraction between 2012 and 2017 were included. Data were acquired at baseline, at 3 months and at last available follow-up (FU). Three hundred and fifty-three patients were included (69% male; age 56 ± 15 years; left ventricular ejection fraction 25 ± 8%). FU after the WCD was 2.8 ± 1.5 years with a maximum of 6.8 years. Daily WCD wear time was 22 ± 4 h. Fourteen patients (4%) received appropriate WCD shocks. Two patients (0.6%) died during the WCD period. Thirty patients (9%) died during extended FU. Mean estimated survival after the WCD was similar between patients with and without WCD shocks. Patients without an ICD recommendation after WCD prescription did not experience SCD during FU. CONCLUSIONS: Patients with WCD shocks showed a favourable survival. Patients without an ICD recommendation after WCD prescription had no SCD during FU. These findings support the practice of careful risk stratification before considering an ICD and the use of the WCD for temporary protection from SCD.


Asunto(s)
Desfibriladores Implantables , Dispositivos Electrónicos Vestibles , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda
12.
ESC Heart Fail ; 8(2): 1502-1508, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33538124

RESUMEN

AIMS: Patients with adult congenital heart disease (ACHD) carry an increased risk for sudden cardiac death. Implantable cardioverter-defibrillator (ICD) therapy may be challenging in these patients due to anatomical barriers, repeated cardiac surgery, or complicated transvenous access. Thus, the subcutaneous ICD (S-ICD) can be a promising alternative in this patient population. Patients with ACHD show significant electrocardiogram (ECG) abnormalities, which could affect S-ICD sensing because it depends on surface ECG. METHODS AND RESULTS: One hundred patients with ACHD were screened for S-ICD eligibility. Standard ECG-based screening test and automated S-ICD screening test were performed in all patients. Sixty-six patients (66%) were male. Underlying congenital heart disease (CHD) was mainly CHD of great complexity (71%) and moderate complexity (29%), including repaired tetralogy of Fallot (20%), which was the most common entity. Thirty-seven patients (37%) already had a pacemaker (23%) or ICD (14%) implanted. Automated screening test identified 83 patients (83%) eligible for S-ICD implantation in either left parasternal position (78%) or right parasternal position (75%). Absence of sinus rhythm, QRS duration, and a paced QRS complex were associated with S-ICD screening failure in univariate analysis. Receiver operating characteristic curve and multivariate analysis revealed a QRS duration ≥148 ms as the only independent predictor for S-ICD screening failure. CONCLUSIONS: Patients with ACHD show satisfactory eligibility rates (83%) for S-ICD implantation utilizing the automated screening test, including patients with CHD of high complexity. S-ICD therapy should be considered with caution in ACHD patients with a QRS duration ≥148 ms and/or need for ventricular pacing.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Adulto , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Determinación de la Elegibilidad , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Humanos , Masculino , Selección de Paciente
13.
J Interv Card Electrophysiol ; 60(2): 303-311, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32613315

RESUMEN

PURPOSE: The subcutaneous implantable cardioverter-defibrillator (S-ICD) could be a promising alternative to the conventional transvenous ICD in patients with LVAD due to its reduced risk of infection. However, surface ECG is altered following LVAD implantation and, since S-ICD detection is based on surface ECG, S-ICD could be potentially affected. The aim of the present study was to analyze S-ICD eligibility in patients with LVAD. METHODS: Seventy-five patients implanted with an LVAD were included in this prospective single-center study. The ECG-based screening test and the automated screening test were performed in all patients. RESULTS: Fifty-five (73.3%) patients had either a positive ECG-based or automated screening test. Out of these, 28 (37.3%) patients were found eligible for S-ICD implantation with both screening tests performed. ECG-based screening test was positive in 50 (66.6%) patients; automated screening test was positive in 33 (44.0%) patients. Three ECG-based screening tests could not be evaluated due to artifacts. With the automated screening test, in 9 (12.0%) patients, the test yielded no result. CONCLUSIONS: Patients implanted with an LVAD showed lower S-ICD eligibility rates compared with patients without LVAD. With an S-ICD eligibility rate of maximal 73.3%, S-ICD therapy may be a feasible option in these patients. Nevertheless, S-ICD implantation should be carefully weighed against potential device-device interference. Prospective studies regarding S-ICD eligibility before and after LVAD implantation are required to further elucidate the role of S-ICD therapy in this population.


Asunto(s)
Desfibriladores Implantables , Corazón Auxiliar , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Humanos , Estudios Prospectivos
14.
J Cardiovasc Electrophysiol ; 31(12): 3286-3292, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33017069

RESUMEN

INTRODUCTION: In patients with a left ventricular assist device (LVAD), the subcutaneous implantable cardioverter-defibrillator (S-ICD) can be an alternative to transvenous ICD systems due to reduced risk of systemic infection, which could lead to extraction of the ICD as well as the LVAD. S-ICD eligibility is lower in patients with LVAD than in patients with end-stage heart failure without LVAD. Several reports have shown inappropriate S-ICD therapy in the coexistence of LVAD and S-ICD. The aim of the present study was to evaluate S-ICD eligibility in patients with LVAD using the established electrocardiogram (ECG)-based screening test as well as a novel device-based screening test to identify potentially inappropriate S-ICD sensing in this specific patient cohort. METHODS AND RESULTS: The present study included 115 patients implanted with an LVAD. The standard ECG-based screening test and a novel device-based screening test were performed in all patients. Eighty patients (70%) were eligible for S-ICD therapy with the standard ECG-based screening test. Performance of the novel device-based screening test identified device-device interference in 14 of these 80 patients (12%). CONCLUSION: Using a novel extended device-based S-ICD screening method, a small number of patients with LVAD deemed eligible for S-ICD with the standard ECG-based screening test exhibit device-device interference. Careful S-ICD screening should be performed in patients with LVAD, who are candidates for S-ICD therapy, to prevent inappropriate sensing or ICD therapy.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Estudios de Cohortes , Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos
15.
ESC Heart Fail ; 7(5): 2992-3002, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32710603

RESUMEN

AIMS: Inhibition of neprilysin and angiotensin II receptor by sacubitril/valsartan (Val) (LCZ696) reduces mortality in heart failure (HF) patients compared with sole inhibition of renin-angiotensin system. Beneficial effects of increased natriuretic peptide levels upon neprilysin inhibition have been proposed, whereas direct effects of sacubitrilat (Sac) (LBQ657) on myocardial Ca2+ cycling remain elusive. METHODS AND RESULTS: Confocal microscopy (Fluo-4 AM) was used to investigate pro-arrhythmogenic sarcoplasmic reticulum (SR) Ca2+ leak in freshly isolated murine and human ventricular cardiomyocytes (CMs) upon Sac (40 µmol/L)/Val (13 µmol/L) treatment. The concentrations of Sac and Val equalled plasma concentrations of LCZ696 treatment used in PARADIGM-HF trial. Epifluorescence microscopy measurements (Fura-2 AM) were performed to investigate effects on systolic Ca2+ release, SR Ca2+ load, and Ca2+ -transient kinetics in freshly isolated murine ventricular CMs. The impact of Sac on myocardial contractility was evaluated using in toto-isolated, isometrically twitching ventricular trabeculae from human hearts with end-stage HF. Under basal conditions, the combination of Sac/Val did not influence diastolic Ca2+ -spark frequency (CaSpF) nor pro-arrhythmogenic SR Ca2 leak in isolated murine ventricular CMs (n CMs/hearts = 80/7 vs. 100/7, P = 0.91/0.99). In contrast, Sac/Val treatment reduced CaSpF by 35 ± 9% and SR Ca2+ leak by 45 ± 9% in CMs put under catecholaminergic stress (isoproterenol 30 nmol/L, n = 81/7 vs. 62/7, P < 0.001 each). This could be attributed to Sac, as sole Sac treatment also reduced both parameters by similar degrees (reduction of CaSpF by 57 ± 7% and SR Ca2+ leak by 76 ± 5%; n = 101/4 vs. 108/4, P < 0.01 each), whereas sole Val treatment did not. Systolic Ca2+ release, SR Ca2+ load, and Ca2+ -transient kinetics including SERCA activity (kSERCA ) were not compromised by Sac in isolated murine CMs (n = 41/6 vs. 39/6). Importantly, the combination of Sac/Val and Sac alone also reduced diastolic CaSpF and SR Ca2+ leak (reduction by 74 ± 7%) in human left ventricular CMs from patients with end-stage HF (n = 71/8 vs. 78/8, P < 0.05 each). Myocardial contractility of human ventricular trabeculae was not acutely affected by Sac treatment as the developed force remained unchanged over a time course of 30 min (n trabeculae/hearts = 3/3 vs. 4/3). CONCLUSION: This study demonstrates that neprilysin inhibitor Sac directly improves Ca2+ homeostasis in human end-stage HF by reducing pro-arrhythmogenic SR Ca2+ leak without acutely affecting systolic Ca2+ release and inotropy. These effects might contribute to the mortality benefits observed in the PARADIGM-HF trial.


Asunto(s)
Insuficiencia Cardíaca , Retículo Sarcoplasmático , Animales , Arritmias Cardíacas , Calcio , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Ratones , Miocitos Cardíacos
16.
Basic Res Cardiol ; 114(2): 13, 2019 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-30788598

RESUMEN

Increased late sodium current (late INa) is an important arrhythmogenic trigger in cardiac disease. It prolongs cardiac action potential and leads to an increased SR Ca2+ leak. This study investigates the contribution of Ca2+/Calmodulin-dependent kinase II (CaMKII), protein kinase A (PKA) and conversely acting protein phosphatases 1 and 2A (PP1, PP2A) to this subcellular crosstalk. Augmentation of late INa (ATX-II) in murine cardiomyocytes led to an increase of diastolic Ca2+ spark frequency and amplitudes of Ca2+ transients but did not affect SR Ca2+ load. Interestingly, inhibition of both, CaMKII and PKA, attenuated the late INa-dependent induction of the SR Ca2+ leak. PKA inhibition additionally reduced the amplitudes of systolic Ca2+ transients. FRET-measurements revealed increased levels of cAMP upon late INa augmentation, which could be prevented by simultaneous inhibition of Na+/Ca2+-exchanger (NCX) suggesting that PKA is activated by Ca2+-dependent cAMP-production. Whereas inhibition of PP2A showed no effect on late INa-dependent alterations of Ca2+ cycling, additional inhibition of PP1 further increased the SR Ca2+ leak. In line with this, selective activation of PP1 yielded a strong reduction of the late INa-induced SR Ca2+ leak and did not affect systolic Ca2+ release. This study indicates that phosphatase/kinase-balance is perturbed upon increased Na+ influx leading to disruption of ventricular Ca2+ cycling via CaMKII- and PKA-dependent pathways. Importantly, an activation of PP1 at RyR2 may represent a promising new toehold to counteract pathologically increased kinase activity.


Asunto(s)
Proteína Quinasa Tipo 2 Dependiente de Calcio Calmodulina/metabolismo , Miocitos Cardíacos/metabolismo , Proteína Fosfatasa 1/metabolismo , Proteína Fosfatasa 2/metabolismo , Potenciales de Acción/fisiología , Animales , Calcio/metabolismo , Ratones , Sodio/metabolismo
17.
Eur J Heart Fail ; 20(12): 1673-1685, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30191648

RESUMEN

BACKGROUND: Disruption of Ca2+ homeostasis is a key pathomechanism in heart failure. CaMKII-dependent hyperphosphorylation of ryanodine receptors in the sarcoplasmic reticulum (SR) increases the arrhythmogenic SR Ca2+ leak and depletes SR Ca2+ stores. The contribution of conversely acting serine/threonine phosphatases [protein phosphatase 1 (PP1) and 2A (PP2A)] is largely unknown. METHODS AND RESULTS: Human myocardium from three groups of patients was investigated: (i) healthy controls (non-failing, NF, n = 8), (ii) compensated hypertrophy (Hy, n = 16), and (iii) end-stage heart failure (HF, n = 52). Expression of PP1 was unchanged in Hy but greater in HF compared to NF while its endogenous inhibitor-1 (I-1) was markedly lower expressed in both compared to NF, suggesting increased total PP1 activity. In contrast, PP2A expression was lower in Hy and HF compared to NF. Ca2+ homeostasis was severely disturbed in HF compared to Hy signified by a higher SR Ca2+ leak, lower systolic Ca2+ transients as well as a decreased SR Ca2+ load. Inhibition of PP1/PP2A by okadaic acid increased SR Ca2+ load and systolic Ca2+ transients but severely aggravated diastolic SR Ca2+ leak and cellular arrhythmias in Hy. Conversely, selective activation of PP1 by a PP1-disrupting peptide (PDP3) in HF potently reduced SR Ca2+ leak as well as cellular arrhythmias and, importantly, did not compromise systolic Ca2+ release and SR Ca2+ load. CONCLUSION: This study is the first to functionally investigate the role of PP1/PP2A for Ca2+ homeostasis in diseased human myocardium. Our data indicate that a modulation of phosphatase activity potently impacts Ca2+ cycling properties. An activation of PP1 counteracts increased kinase activity in heart failure and successfully seals the arrhythmogenic SR Ca2+ leak. It may thus represent a promising future antiarrhythmic therapeutic approach.


Asunto(s)
Calcio/metabolismo , Activación Enzimática , Insuficiencia Cardíaca/metabolismo , Miocardio/metabolismo , Proteína Fosfatasa 1/metabolismo , Retículo Sarcoplasmático/metabolismo , Anciano , Western Blotting , Femenino , Insuficiencia Cardíaca/patología , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Fosforilación , Retículo Sarcoplasmático/patología
18.
ESC Heart Fail ; 5(5): 960-964, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30079993

RESUMEN

Here we discuss a case of arrhythmia-induced cardiomyopathy (AIC) with consecutive severe multiple organ failure. In relation to this imposing case, we discuss the significance of this potentially underestimated cause of newly occurred left-ventricular systolic dysfunction and concomitant arrhythmia. We further delineate the diagnostic algorithm and differential diagnoses of AIC.


Asunto(s)
Arritmias Cardíacas/complicaciones , Cardiomiopatías/diagnóstico , Ventrículos Cardíacos/fisiopatología , Función Ventricular Izquierda/fisiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/cirugía , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Ablación por Catéter , Ecocardiografía Transesofágica , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Sístole
19.
Artif Organs ; 40(8): 719-26, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26816346

RESUMEN

In heart failure, left ventricular assist device (LVAD) implantation is performed to ensure sufficient cardiac output. Whereas some patients are subsequently weaned from LVAD support, other patients still need heart transplantation. To elucidate underlying mechanisms, we assessed the arrhythmogenic SR-Ca(2+) leak at the time of LVAD implantation (HF-Im) and heart transplantation (HF-Tx) and evaluated the effects of CaMKII-inhibition. Human left-ventricular cardiomyocytes were isolated, paced at 1 Hz for 10 beats to ensure SR-Ca(2+) loading and scanned for diastolic Ca(2+) sparks (confocal microscopy). In HF-Im, the high diastolic spark frequency (CaSpF) of 0.76 ± 0.12 × 100 µm(-1) × s(-1) could be reduced to 0.48 ± 0.10 × 100 µm(-1) × s(-1) by CaMKII inhibition (AIP, 1 µM). The amplitude of Ca(2+) sparks, width, and length was not significantly altered. In sum, CaMKII inhibition yielded a clear tendency toward a reduction of the SR-Ca(2+) leak (n cells/patients = 76/6 vs. 108/6, P = 0.08). In HF-Tx, we detected an even higher CaSpF of 1.00 ± 0.10 100 µm(-1) × s(-1) and a higher SR-Ca(2+) leak compared with HF-Im (increase by 81 ± 33%, n cells/patients = 156/7 vs. 130/7, P < 0.05), which fits to the further decreased LV function. Here, CaMKII inhibition likewise reduced CaSpF (0.35 ± 0.09 100 µm(-1) × s(-1,) P = 0.06) and significantly reduced spark duration (n sparks/patients = 58/3 vs. 159/3, P < 0.05). Conclusively, the SR-Ca(2+) leak was reduced by 69 ± 12% in HF-Tx upon CaMKII inhibition (n cells/patients = 53/3 vs. 91/3, P < 0.05). These data show that the SR-Ca(2+) leak correlates with the development of LV function after LVAD implantation and may represent an important pathomechanism. The fact that CaMKII inhibition reduces the SR-Ca(2+) leak in HF-Tx suggests that CaMKII inhibition may be a promising option to beneficially influence clinical course after LVAD implantation.


Asunto(s)
Proteína Quinasa Tipo 2 Dependiente de Calcio Calmodulina/antagonistas & inhibidores , Calcio/metabolismo , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Miocitos Cardíacos/efectos de los fármacos , Péptidos/farmacología , Inhibidores de Proteínas Quinasas/farmacología , Adulto , Proteína Quinasa Tipo 2 Dependiente de Calcio Calmodulina/metabolismo , Células Cultivadas , Femenino , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/patología , Trasplante de Corazón , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/cirugía , Homeostasis/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología
20.
Europace ; 18(9): 1440-8, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26493982

RESUMEN

AIMS: Clinical studies have shown differences in the propensity for malignant ventricular arrhythmias between women and men suffering from cardiomyopathies and heart failure (HF). This is clinically relevant as it impacts therapies like prophylactic implantable cardioverter-defibrillator implantation but the pathomechanisms are unknown. As an increased sarcoplasmic reticulum (SR) Ca(2+) leak is arrhythmogenic, it could represent a cellular basis for this paradox. METHODS/RESULTS: We evaluated the SR Ca(2+) leak with respect to sex differences in (i) afterload-induced cardiac hypertrophy (Hy) with preserved left ventricular (LV) function and (ii) end-stage HF. Cardiac function did not differ between sexes in both cardiac pathologies. Human cardiomyocytes isolated from female patients with Hy showed a significantly lower Ca(2+) spark frequency (CaSpF, confocal microscopy, Fluo3-AM) compared with men (P < 0.05). As Ca(2+) spark width and duration were similar in women and men, this difference in CaSpF did not yet translate into a significant difference of the calculated SR Ca(2+) leak between both sexes at this stage of disease (P = 0.14). Epifluorescence measurements (Fura2-AM) revealed comparable Ca(2+) cycling properties (diastolic Ca(2+) levels, amplitude of systolic Ca(2+) transients, SR Ca(2+) load) in patients of both sexes suffering from Hy. Additionally, the increased diastolic CaSpF in male patients with Hy did not yet translate into an elevated ratio of cells showing arrhythmic events (Ca(2+) waves, spontaneous Ca(2+) transients) (P = 0.77). In the transition to HF, both sexes showed an increase of the CaSpF (P < 0.05) and the sex dependence was even more pronounced. Female patients had a 69 ± 10% lower SR Ca(2+) leak (P < 0.05), which now even translated into a lower ratio of arrhythmic cells in female HF patients compared with men (P < 0.001). CONCLUSION: These data show that the SR Ca(2+) leak is lower in women than in men with comparable cardiac impairment. Since the SR Ca(2+) leak triggers delayed afterdepolarizations, our findings may explain why women are less prone to ventricular arrhythmias and confirm the rationale of therapeutic measures reducing the SR Ca(2+) leak.


Asunto(s)
Arritmias Cardíacas/etiología , Señalización del Calcio , Cardiomegalia/complicaciones , Insuficiencia Cardíaca/complicaciones , Miocitos Cardíacos/metabolismo , Retículo Sarcoplasmático/metabolismo , Adulto , Anciano , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/fisiopatología , Cardiomegalia/metabolismo , Cardiomegalia/fisiopatología , Femenino , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Microscopía Confocal , Microscopía Fluorescente , Persona de Mediana Edad , Contracción Miocárdica , Factores Sexuales , Factores de Tiempo , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...