Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
Intern Med J ; 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39485035

RESUMEN

Kidney involvement occurs in almost one third of patients hospitalised with coronavirus disease 2019 (COVID-19) and is associated with increased disease severity. This review aims to outline the spectrum of kidney pathology involved in COVID-19. Literature was reviewed systematically on the databases Medline OVID and Scopus in search of case reports, case series, cohort studies and autopsy studies of patients with COVID-19 who underwent kidney biopsies. Studies were published between August 2020 and November 2021. Fourteen studies consisting of 159 patients were included in this review. Acute tubular necrosis is the most common pathology followed by collapsing glomerulopathy, occurring in 40.1% and 28.9% of patients respectively. Of the 46 patients with collapsing glomerulopathy, 44 were of African descent with high-risk apolipoprotein L1 genotypes. Less common glomerular diseases include membranous nephropathy, secondary focal segmental glomerulosclerosis, minimal change disease and primary focal segmental glomerulosclerosis occurring in 5%, 4.4%, 3.1% and 2.5% of patients respectively. Glomerulonephritis occurred in a minority of patients. Direct viral infection has not been found as a definitive aetiology. Acute kidney injury occurs frequently in hospitalised COVID-19 patients and is associated with increased morbidity and mortality. The mechanisms underpinning acute kidney injury are multifactorial. Acute tubular necrosis is the most common. Collapsing glomerulopathy is the most common glomerular injury and is strongly linked to apolipoprotein L1 genotypes. Improved understanding of COVID-19-related kidney pathologies can guide treatment to improve patient outcomes and reduce progression of chronic kidney disease. The longitudinal impact of COVID-19-related kidney disease requires further research.

2.
J Diabetes ; 16(10): e13609, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39364792

RESUMEN

Glucagon-like peptide-1 receptor agonists (GLP-1RAs) have gained increasing attention for their potential benefits in people with type 2 diabetes mellitus (T2DM) with chronic kidney disease (CKD). Most supportive evidence of a kidney-protective effect of the GLP-1RA class of medications has been derived from kidney-related outcomes reported from cardiovascular outcome trials (CVOTs). GLP-1RAs have been shown to reduce albuminuria, mitigate cardiovascular risk, and possibly attenuate estimated glomerular filtration rate (eGFR) decline. The kidney-protective effects of GLP-1RAs are thought to be attributed to their anti-inflammatory, antioxidant, and vasodilatory properties. Despite these promising findings, the use of GLP-RAs has yet to be definitively shown to slow progression to chronic kidney failure in people with T2DM. The Research Study to See How Semaglutide Works Compared to Placebo in People With Type 2 Diabetes and Chronic Kidney Disease (FLOW trial) is the first major trial assessing the potential of a GLP-1RA to slow progression of kidney disease in people with established CKD to clinically important kidney end points. On March 5, 2024, the top line result from FLOW was announced with semaglutide 1.0 mg being reported to reduce the primary end point of the trial by a significant 24% compared with placebo. Here, we summarize the kidney outcomes reported from CVOTs for the GLP-1RA class of medication and briefly describe kidney outcomes from other major GLP-1RAs trials. We also discuss a potential role of the dual GLP-1/glucose-dependent insulinotropic polypeptide (GIP) receptor agonist, tirzepatide, as a kidney-protective agent.


Asunto(s)
Diabetes Mellitus Tipo 2 , Receptor del Péptido 1 Similar al Glucagón , Insuficiencia Renal Crónica , Humanos , Receptor del Péptido 1 Similar al Glucagón/agonistas , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/complicaciones , Insuficiencia Renal Crónica/tratamiento farmacológico , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/complicaciones , Nefropatías Diabéticas/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Péptidos Similares al Glucagón/uso terapéutico , Tasa de Filtración Glomerular/efectos de los fármacos , Riñón/efectos de los fármacos , Riñón/fisiopatología , Progresión de la Enfermedad , Agonistas Receptor de Péptidos Similares al Glucagón
3.
Med J Aust ; 221(9): 486-490, 2024 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-39434516

RESUMEN

OBJECTIVES: To review evidence regarding the impact of physical activity interventions for preventing and managing type 2 diabetes in Aboriginal and Torres Strait Islander Australians. STUDY DESIGN: We searched for published reports of physical activity interventions for preventing and managing type 2 diabetes in Indigenous adults (18 years or older). There were no exclusion criteria regarding study type or duration, frequency, length, or intensity of physical activity, except that short term interventions were excluded. We assessed the quality of each study using the Joanna Briggs Institute (JBI) critical appraisal tools and the ethical and methodological quality of studies from an Indigenous Australian perspective with the Centre of Research Excellence in Aboriginal Chronic Disease Knowledge Translation and Exchange (CREATE) Critical Appraisal Tool. DATA SOURCES: MEDLINE; Scopus, Embase (Elsevier); Cumulative Index to Nursing and Allied Health Literature (CINAHL), Sports Discus, PsycINFO (EBSCO); Informit Complete; ProQuest Dissertations and Theses, and ProQuest Health and Medicine; each from their inception to 30 October 2022. RESULTS: The database searches identified 703 potentially relevant records; after removing duplicates and initial screening, the full text of 27 articles was assessed for eligibility. Nine studies met our inclusion criteria: two randomised controlled trials, five cohort studies, one quasi-experimental study, and one repeated cross-sectional study. Eight studies were rated as being of low or medium quality (median JBI score, 54%; interquartile range [IQR], 36-64%); seven studies were rated as being of low to medium ethical and methodological quality from the Indigenous perspective (median CREATE score, 50%; IQR, 36-64%). Six studies reported changes in glycated haemoglobin (HbA1c) levels, of which two (both cohort studies) reported significantly lower mean HbA1c levels after the intervention, but only one publication provided detailed results. No randomised controlled trials that investigated the effect of a combination of physical activity and dietary change for Indigenous Australians diagnosed with type 2 diabetes were identified. Differences in study design, outcome variables, and the small number of studies precluded meta-analysis. CONCLUSIONS: Quality research into the impact of physical activity interventions on type 2 diabetes in Indigenous people is sparse. To improve research translation, studies that involve Indigenous community members at all levels of the research process are needed. REGISTRATION: PROSPERO CRD42021247496 (prospective).


Asunto(s)
Diabetes Mellitus Tipo 2 , Ejercicio Físico , Nativos de Hawái y Otras Islas del Pacífico , Humanos , Diabetes Mellitus Tipo 2/etnología , Diabetes Mellitus Tipo 2/terapia , Diabetes Mellitus Tipo 2/prevención & control , Australia , Adulto , Aborigenas Australianos e Isleños del Estrecho de Torres
4.
Diabet Med ; 41(10): e15418, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39113257

RESUMEN

AIM: Incorporating health-related quality of life (HRQoL) measures into health economic analyses can help to provide evidence to inform decisions about how to improve patient outcomes in the most cost-effective manner. The aim of this narrative review was to assess which HRQoL instruments have been used in economic evaluations of type 2 diabetes management including in Indigenous communities. METHOD: MEDLINE (Ovid), Embase (Ovid) and Cochrane were searched from inception to June 2022. Studies included patients with type 2 diabetes; economic evaluations, derived scores from direct questioning of individuals; and were in English. Records were assessed for bias using the JBI critical appraisal tools. RESULTS: A total of 3737 records were identified, with 22 publications meeting the criteria for inclusion. Across those 22 articles, nine HRQoL instruments had been utilised. Generic tools were most frequently used to measure HRQoL, including EQ-5D (-3 L and -5 L) (n = 10, 38%); SF-12 (n = 5, 19%); and SF-36 (n = 4, 15%). Two tools addressing the specific stressors faced by people with type 2 diabetes were utilised: Problem Areas In Diabetes tool (n = 1, 4%) and Diabetes Distress Scale (n = 1, 4%). Two publications reported whether the study population included Indigenous peoples. CONCLUSION: A wide range of HRQoL instruments are used in economic evaluations of type 2 diabetes management, with the most frequent being varying forms of the EQ-5D. Few economic evaluations noted whether Indigenous peoples were featured in the study population. More research into HRQoL in people living with type 2 diabetes is urgently needed to improve evidence on effectiveness and cost-effectiveness of interventions.


Asunto(s)
Análisis Costo-Beneficio , Diabetes Mellitus Tipo 2 , Calidad de Vida , Diabetes Mellitus Tipo 2/economía , Diabetes Mellitus Tipo 2/psicología , Diabetes Mellitus Tipo 2/terapia , Humanos , Encuestas y Cuestionarios
6.
Lancet Diabetes Endocrinol ; 12(8): 569-595, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39054035

RESUMEN

Artificial intelligence (AI) use in diabetes care is increasingly being explored to personalise care for people with diabetes and adapt treatments for complex presentations. However, the rapid advancement of AI also introduces challenges such as potential biases, ethical considerations, and implementation challenges in ensuring that its deployment is equitable. Ensuring inclusive and ethical developments of AI technology can empower both health-care providers and people with diabetes in managing the condition. In this Review, we explore and summarise the current and future prospects of AI across the diabetes care continuum, from enhancing screening and diagnosis to optimising treatment and predicting and managing complications.


Asunto(s)
Inteligencia Artificial , Diabetes Mellitus , Humanos , Inteligencia Artificial/tendencias , Diabetes Mellitus/terapia , Diabetes Mellitus/diagnóstico
7.
Nephrology (Carlton) ; 29(8): 457-469, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39030739

RESUMEN

Glucagon-like peptide-1 receptor agonists (GLP-1RAs) have gained increasing attention for their potential benefits in people with type 2 diabetes (T2DM) with chronic kidney disease (CKD). This class of medication has demonstrated promising results in reducing albuminuria, preserving estimated glomerular filtration rate (eGFR), and mitigating cardiovascular (CV) risk, making them potential therapeutic options for individuals with CKD. The kidney protective effects of GLP-1RAs extend beyond glycaemic control, and are thought to be attributed to their anti-inflammatory, antioxidant, and natriuretic properties. Despite these promising findings, the use of GLP-RAs has yet to be definitively shown to slow progression to chronic kidney failure, or reduce CV and kidney related death in people with T2DM and CKD. The Research Study to See How Semaglutide (a once weekly subcutaneous administered GLP-1RA) Works Compared to Placebo in People with Type 2 Diabetes and Chronic Kidney Disease (FLOW trial) was recently stopped because of efficacy. The primary end point for the FLOW trial consists of a composite endpoint of (i) onset of chronic kidney failure; (ii) death from kidney failure; (iii) cardiovascular death; and (iv) onset of a persistent ≥50% reduction in eGFR from baseline. It has also been reported by the sponsors of the trial that the primary end point of the trial was reduced by 24% with both CKD and CV outcomes contributing to risk reduction. In anticipation of the results of the FLOW trial being published, we review the current evidence surrounding kidney outcomes and proposed kidney protective pathways associated with GLP-1RA use.


Asunto(s)
Diabetes Mellitus Tipo 2 , Nefropatías Diabéticas , Receptor del Péptido 1 Similar al Glucagón , Riñón , Insuficiencia Renal Crónica , Humanos , Receptor del Péptido 1 Similar al Glucagón/agonistas , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/complicaciones , Insuficiencia Renal Crónica/tratamiento farmacológico , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/mortalidad , Riñón/efectos de los fármacos , Riñón/fisiopatología , Nefropatías Diabéticas/prevención & control , Nefropatías Diabéticas/tratamiento farmacológico , Resultado del Tratamiento , Hipoglucemiantes/uso terapéutico , Tasa de Filtración Glomerular/efectos de los fármacos , Incretinas/uso terapéutico , Agonistas Receptor de Péptidos Similares al Glucagón
8.
J Diabetes Sci Technol ; : 19322968241266822, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075942

RESUMEN

BACKGROUND AND AIM: Continuous glucose monitoring systems (CGMs) have been commercially available since 1999. However, automated insulin delivery systems may benefit from real-time inputs in addition to glucose. Continuous multi-analyte sensing platforms will meet this area of potential growth without increasing the burden of additional devices. We aimed to generate pilot data regarding the safety and function of a first-in-human, single-probe glucose/lactate multi-analyte continuous sensor. METHODS: The investigational glucose/lactate continuous multi-analyte sensor (PercuSense Inc, Valencia, California) was inserted to the upper arms of 16 adults with diabetes, and data were available for analysis from 11 of these participants (seven female; mean [SD] = age 43 years [16]; body mass index [BMI] = 27 kg/m2 [5]). A commercially available Guardian 3 CGM (Medtronic, Northridge, California) was also inserted into the abdomen for comparison. All participants underwent a meal-test followed by an exercise challenge on day 1 and day 4 of wear. Performance was benchmarked against venous blood YSI glucose and lactate values. RESULTS: The investigational glucose sensor had an overall mean absolute relative difference (MARD) of 14.5% (median = 11.2%) which improved on day 4 compared with day 1 (13.9% vs 15.2%). The Guardian 3 CGM had an overall MARD of 13.9% (median = 9.4%). The lactate sensor readings within 20/20% and 40/40% of YSI values were 59.7% and 83.1%, respectively. CONCLUSIONS: Our initial data support safety and functionality of a novel glucose/lactate continuous multi-analyte sensor. Further sensor refinement will improve run-in performance and accuracy.

9.
Artículo en Inglés | MEDLINE | ID: mdl-39052325

RESUMEN

The incidence, prevalence, mortality, and health expenditure associated with diabetes continue to grow, despite efforts. The use of multianalyte sensors, which detect glucose as well as key analytes such as ketones, lactate, insulin, uric acid, and electrolytes, may provide additional information to guide earlier identification and management of diabetes and its complications. We undertook a narrative review using a systematic approach in May 2023, with a bridge search undertaken in April 2024. Four biomedical databases were searched: MEDLINE (Ovid), Embase, Emcare, and Cochrane Library. Searches for gray literature were conducted on ClinicalTrials.gov, Google Scholar, and websites of relevant organizations. Included studies incorporated articles on multianalyte sensors in diabetes and single-analyte sensors proposing integration into multianalyte diabetes management, with no limits placed on publication date and study design. Data were screened and extracted using CovidenceTM software. Overall, 11 articles were included, of which 7 involved multianalyte sensors (involving glucose and other analytes) and 4 single-analyte sensors (measuring non-glucose substances for proposed future integration into multianalyte systems). Analytes examined were ketones (n = 3), lactate (n = 4), uric acid (n = 3), insulin (n = 1), and potassium (n = 1). Results demonstrated that in vitro and in vivo measurements of multi- and single-analyte sensors accurately and reliably corresponded with human capillary and serum samples. While the literature on this topic is sparse, our review demonstrated that measurement of glucose and other analytes can be feasibly undertaken using multi- and single-analyte sensors. More studies in humans are needed to establish clinical utility in diabetes self-management and assist with technological improvements.

10.
Trials ; 25(1): 493, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39030640

RESUMEN

BACKGROUND: Aboriginal and Torres Strait Islander peoples are disproportionately impacted by type 2 diabetes. Continuous glucose monitoring (CGM) technology (such as Abbott Freestyle Libre 2, previously referred to as Flash Glucose Monitoring) offers real-time glucose monitoring that is convenient and easy to use compared to self-monitoring of blood glucose (SMBG). However, this technology's use is neither widespread nor subsidised for Aboriginal and Torres Strait Islander peoples with type 2 diabetes. Building on existing collaborations with a national network of Aboriginal and Torres Strait Islander communities, this randomised controlled trial aims to assess the effect of CGM compared to SMBG on (i) haemoglobin A1c (HbA1c), (ii) achieving blood glucose targets, (iii) reducing hypoglycaemic episodes and (iv) cost-effective healthcare in an Aboriginal and Torres Strait Islander people health setting. METHODS: This is a non-masked, parallel-group, two-arm, individually randomised, controlled trial (ACTRN12621000753853). Aboriginal and Torres Strait Islander adults with type 2 diabetes on injectable therapy and HbA1c ≥ 7.5% (n = 350) will be randomised (1:1) to CGM or SMBG for 6 months. The primary outcome is change in HbA1c level from baseline to 6 months. Secondary outcomes include (i) CGM-derived metrics, (ii) frequency of hypoglycaemic episodes, (iii) health-related quality of life and (iv) incremental cost per quality-adjusted life year gained associated with the CGM compared to SMBG. Clinical trial sites include Aboriginal Community Controlled Organisations, Aboriginal Medical Services, primary care centres and tertiary hospitals across urban, rural, regional and remote Australia. DISCUSSION: The trial will assess the effect of CGM compared to SMBG on HbA1c for Aboriginal and Torres Strait Islander people with type 2 diabetes in Australia. This trial could have long-term benefits in improving diabetes management and providing evidence for funding of CGM in this population. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry ACTRN12621000753853. Registered on 15th June 2021.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Análisis Costo-Beneficio , Diabetes Mellitus Tipo 2 , Hemoglobina Glucada , Adulto , Humanos , Australia , Aborigenas Australianos e Isleños del Estrecho de Torres , Biomarcadores/sangre , Glucemia/metabolismo , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/etnología , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/terapia , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/análisis , Control Glucémico , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Tiempo , Resultado del Tratamiento
11.
Diabet Med ; 41(9): e15384, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38923618

RESUMEN

AIMS: In tackling rising diabetes-related emergencies, the need to understand and address emergency service usage by people with type 1 diabetes is vital. This review aimed to quantify current trends in presentations for type 1 diabetes-related emergencies and identify public health strategies that reduce the frequency of diabetes-related emergencies and improve glycaemic management. METHODS: Medline (OVID), Cochrane and CINAHL were searched for studies published between 2000 and 2023, focusing on people with type 1 diabetes, severe hypoglycaemia and/or diabetic ketoacidosis, and ambulance and/or emergency department usage. There were 1313 papers identified, with 37 publications meeting review criteria. RESULTS: The incidence of type 1 diabetes-related emergencies varied from 2.4 to 14.6% over one year for hypoglycaemic episodes, and between 0.07 and 11.8 events per 100 person-years for hyperglycaemic episodes. Notably, our findings revealed that ongoing diabetes education and the integration of diabetes technology, such as continuous glucose monitoring and insulin pump therapy, significantly reduced the incidence of these emergencies. However, socio-economic disparities posed barriers to accessing these technologies, subsequently shifting the cost to emergency healthcare and highlighting the need for governments to consider subsidising these technologies as part of preventative measures. CONCLUSIONS: Improving access to continuous glucose monitoring and insulin pump therapy, in combination with ongoing diabetes education focusing on symptom recognition and early management, will reduce the incidence of diabetes-related emergencies. Concurrent research assessing emergency healthcare usage patterns during the implementation of such measures is essential to ensure these are cost-effective.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/epidemiología , Cetoacidosis Diabética/prevención & control , Cetoacidosis Diabética/epidemiología , Cetoacidosis Diabética/terapia , Hipoglucemia/prevención & control , Hipoglucemia/epidemiología , Hipoglucemiantes/uso terapéutico , Incidencia , Automonitorización de la Glucosa Sanguínea , Servicio de Urgencia en Hospital/estadística & datos numéricos , Sistemas de Infusión de Insulina
12.
Diabetes Technol Ther ; 26(3): 190-197, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444313

RESUMEN

Aim: To assess the real-world performance of MiniMed™ 780G for Australians with type 1 diabetes (T1D) following advanced hybrid closed loop (AHCL) activation and to evaluate the effect of changing from MiniMed 670/770G to 780G. Methods: We analyzed deidentified Carelink™ continuous glucose monitoring (CGM) data from Australian users from January 2020 to December 2022, including the proportion attaining three major consensus targets: Glucose management indicator (GMI <7.0%), time in range (TIR 70-180 mg/dL >70%), and time below range (TBR 70 mg/dL <4%). Results: Comparing 670/770G users (n = 5676) for mean ± standard deviation 364 ± 244 days with 780G users (n = 3566) for 146 ± 145 days, the latter achieved a higher TIR (72.6% ± 10.6% vs. 67.3% ± 11.4%; P < 0.001), lower time above range (TAR) (25.5% ± 10.9% vs. 30.6% ± 11.7%; P < 0.001), and lower GMI (6.9% ± 0.4% vs. 7.2% ± 0.4%; P < 0.001) without compromising TBR (1.9% ± 1.8% vs. 2.0% ± 1.8%; P = 0.0015). Of 1051 670/770G users transitioning to 780G, TIR increased (70.0% ± 10.7% to 74.0% ± 10.2%; P < 0.001), TAR decreased (28.1% ± 10.9% to 24.0% ± 10.7%; P < 0.001), and TBR was unchanged. The percentage of users attaining all three CGM targets was higher in 780G users (50.1% vs. 29.5%; P < 0.001). CGM metrics were stable at 12 months post-transition. Conclusion: Real-world data from Australia shows that a higher proportion of MiniMed 780G users meet clinical targets for CGM consensus metrics compared to MiniMed 670/770G users and glucose control was sustained over 12 months.


Asunto(s)
Pueblos de Australasia , Automonitorización de la Glucosa Sanguínea , Insulina , Humanos , Australia , Glucemia , Insulina/uso terapéutico , Insulina Regular Humana
13.
J Clin Endocrinol Metab ; 109(8): 1984-1995, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38373265

RESUMEN

CONTEXT: Omnipod DASH Insulin Management System is a tubeless insulin pump that overcomes the physical inconveniences of conventional tubed insulin pump therapy (IPT). OBJECTIVE: We compared treatment satisfaction with Omnipod DASH System to usual care (multiple daily injections [MDIs] or tubed IPT) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from 4 diabetes centers in Australia were randomly assigned in a 1:1 nonblinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension during which all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire "current" (ΔDTQ-current) score at 12 weeks (study end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, and glycemic and device-related outcomes at 12 weeks (study end) and 24 weeks (end extension). RESULTS: Treatment satisfaction improved more in the Omnipod group vs the Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs 0.0 [12.8]; P < .001) at study end. Significantly greater improvements in other PROs and glycated hemoglobin A1c were also observed. Improvements in DTQ-current and other PROs comparing study end and end extension were similar. While percentage in time in range change from baseline did not differ at study end (-2.0 [12.7] %), it was significantly greater at end extension (5.6 [10.9] %; P = .016). CONCLUSION: The Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG that was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Satisfacción del Paciente , Calidad de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/uso terapéutico , Glucemia/análisis , Hemoglobina Glucada/análisis , Resultado del Tratamiento , Australia
14.
Diabetes Res Clin Pract ; 208: 111123, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309532

RESUMEN

AIMS: Understanding the lived experience of using a tubeless insulin pump and how this differs compared to usual care (tubed insulin pump therapy (IPT) vs multiple daily injections (MDI)). METHODS: Interviews were conducted after 12-weeks of using the Omnipod DASH Insulin Management System (Insulet, Acton, MA) and analysed using thematic analysis. RESULTS: Fifty-eight adults (35 female; mean age 42;SD 13 years; 35 previous MDI) were interviewed. Most (84 %) wanted to continue using the device. Experiences fit two themes: 1. Taking back control of my diabetes: many previous MDI users perceived improved glycaemic control, explained by more "nuanced" control, with some reporting positive effects during exercise and sleep. Many previous MDI and IPT users endorsed positive experiences in concealing or disclosing their diabetes to others. However, some previous MDI users reported negative psychosocial experiences due to feeling continuously "attached" to their diabetes. 2. Barriers and facilitators of device acceptability: both MDI and IPT users cited wearability, alarms and the financial cost impacted their choice to continue device use. IPT users reported positive wearability experiences. CONCLUSIONS: The tubeless pump improved diabetes management perceptions for both MDI and tubed pump users. However, participants' prior glucose management affected perceptions of its advantages and disadvantages.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Hipoglucemiantes/uso terapéutico , Australia , Insulina/uso terapéutico , Inyecciones , Sistemas de Infusión de Insulina , Glucemia
15.
Clin Res Cardiol ; 113(6): 884-897, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38170251

RESUMEN

BACKGROUND: Mineralocorticoid receptor antagonists (MRAs) have emerged as potential therapy to target the underlying arrhythmogenic substrate in atrial fibrillation (AF). Nevertheless, there have been inconsistent results on the impact of MRAs on AF. OBJECTIVE: We sought to evaluate the effect of MRAs on AF incidence and progression in patients with and without heart failure. METHODS: Electronic databases were searched up to September, 2022 for randomized controlled trials (RCTs) that evaluated MRA use and reported AF outcomes. Primary outcome was a composite of new-onset or recurrent AF. Safety outcomes included hyperkalemia and gynecomastia risks. A random-effects meta-analysis estimated pooled odds ratios (OR) and 95% confidence intervals (CI). RESULTS: 12 RCTs, comprising 11,419 patients treated with various MRAs were included [5960 (52%) on MRA]. On follow-up (6-39 months), 714 (5.5%) patients developed AF. MRA therapy was associated with a 32% reduction in the risk of new-onset or recurrent AF [OR 0.68 (95% CI 0.51-0.92), I2 = 40%]. On subgroup analysis, the greatest benefit magnitude was demonstrated in reducing AF recurrence [OR 0.50 (95% CI 0.30-0.83)] and among patients with left ventricular dysfunction [OR 0.59 (95% CI 0.40-0.85)]. Gynecomastia, but not hyperkalemia, was associated with MRA use. Meta-regression analysis demonstrated that therapy duration was a significant interaction factor driving the effect size (Pinteraction = 0.013). CONCLUSION: MRA use is associated with a reduction in AF risk, especially AF progression. A prominent effect is seen in patients with heart failure, further augmented by therapy duration. Prospective trials are warranted to evaluate MRA use as upstream therapy for preventing this common arrhythmia.


Asunto(s)
Fibrilación Atrial , Progresión de la Enfermedad , Insuficiencia Cardíaca , Antagonistas de Receptores de Mineralocorticoides , Humanos , Antagonistas de Receptores de Mineralocorticoides/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Insuficiencia Cardíaca/epidemiología , Incidencia , Ensayos Clínicos Controlados Aleatorios como Asunto , Salud Global
16.
J Clin Endocrinol Metab ; 109(5): 1189-1197, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38039081

RESUMEN

CONTEXT: Diabetic kidney disease (DKD) is the leading cause of end-stage renal disease. Measures to prevent and treat DKD require better identification of patients most at risk. In this systematic review, we summarize the existing evidence of genetic risk scores (GRSs) and their utility for predicting DKD in people with type 1 or type 2 diabetes. EVIDENCE ACQUISITION: We searched MEDLINE, Embase, Web of Science, and Cochrane Reviews in June 2022 to identify all existing and relevant literature. Main data items sought were study design, sample size, population, single nucleotide polymorphisms of interest, DKD-related outcomes, and relevant summary measures of result. The Critical Appraisal Skills Programme checklist was used to evaluate the methodological quality of studies. EVIDENCE SYNTHESIS: We identified 400 citations of which 15 are included in this review. Overall, 7 studies had positive results, 5 had mixed results, and 3 had negative results. Most studies with the strongest methodological quality (n = 9) reported statistically significant and favourable findings of a GRS's association with at least 1 measure of DKD. CONCLUSION: This systematic review presents evidence of the utility of GRSs to identify people with diabetes that are at high risk of developing DKD. In practice, a robust GRS could be used at the first clinical encounter with a person living with diabetes in order to stratify their risk of complications. Further prospective research is needed.

17.
BMC Health Serv Res ; 23(1): 1377, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066492

RESUMEN

BACKGROUND: Type 2 diabetes mellitus (T2DM) is highly prevalent within the Indigenous Australian community. Novel glucose monitoring technology offers an accurate approach to glycaemic management, providing real-time information on glucose levels and trends. The acceptability and feasibilility of this technology in Indigenous Australians with T2DM has not been investigated. OBJECTIVE: This feasibility phenomenological study aims to understand the experiences of Indigenous Australians with T2DM using flash glucose monitoring (FGM). METHODS: Indigenous Australians with T2DM receiving injectable therapy (n = 8) who used FGM (Abbott Freestyle Libre) for 6-months, as part of a clinical trial, participated in semi-structured interviews. Thematic analysis of the interviews was performed using NVivo12 Plus qualitative data analysis software (QSR International). RESULTS: Six major themes emerged: 1) FGM was highly acceptable to the individual; 2) FGM's convenience was its biggest benefit; 3) data from FGM was a tool to modify lifestyle choices; 4) FGM needed to be complemented with health professional support; 5) FGM can be a tool to engage communities in diabetes management; and 6) cost of the device is a barrier to future use. CONCLUSIONS: Indigenous Australians with T2DM had positive experiences with FGM. This study highlights future steps to ensure likelihood of FGM is acceptable and effective within the wider Indigenous Australian community.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 2 , Humanos , Australia , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 2/terapia , Estudios de Factibilidad , Proyectos Piloto , Aborigenas Australianos e Isleños del Estrecho de Torres
18.
Artículo en Inglés | MEDLINE | ID: mdl-38083027

RESUMEN

Leg ulcers caused by impaired venous blood return are the most typical chronic wound form and have a significant negative impact on the lives of people living with these wounds. Thus, it is important to provide early assessment and appropriate treatment of the wounds to promote their healing in the normal trajectory. Gathering quality wound data is an important component of good clinical care, enabling monitoring of healing progress. This data can also be useful to train machine learning algorithms with a view to predicting healing. Unfortunately, a high volume of good-quality data is needed to create datasets of suitable volume from people with wounds. In order to improve the process of gathering venous leg ulcer (VLU) data we propose the generative adversarial network based on StyleGAN architecture to synthesize new images from original samples. We utilized a dataset that was manually collected as part of a longitudinal observational study of VLUs and successfully synthesized new samples. These synthesized samples were validated by two clinicians. In future work, we plan to further process these new samples to train a fully automated neural network for ulcer segmentation.


Asunto(s)
Úlcera de la Pierna , Úlcera Varicosa , Humanos , Úlcera de la Pierna/diagnóstico por imagen , Úlcera de la Pierna/terapia , Úlcera Varicosa/diagnóstico por imagen , Úlcera Varicosa/tratamiento farmacológico , Cicatrización de Heridas , Estudios Observacionales como Asunto
19.
Stroke ; 54(12): 2962-2971, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-38011235

RESUMEN

BACKGROUND: Hyperglycemia in acute ischemic stroke reduces the efficacy of stroke thrombolysis and thrombectomy, with worse clinical outcomes. Insulin-based therapies are difficult to implement and may cause hypoglycemia. We investigated whether exenatide, a GLP-1 (glucagon-like peptide-1) receptor agonist, would improve stroke outcomes, and control poststroke hyperglycemia with minimal hypoglycemia. METHODS: The TEXAIS trial (Treatment With Exenatide in Acute Ischemic Stroke) was an international, multicenter, phase 2 prospective randomized clinical trial (PROBE [Prospective Randomized Open Blinded End-Point] design) enrolling adult patients with acute ischemic stroke ≤9 hours of stroke onset to receive exenatide (5 µg BID subcutaneous injection) or standard care for 5 days, or until hospital discharge (whichever sooner). The primary outcome (intention to treat) was the proportion of patients with ≥8-point improvement in National Institutes of Health Stroke Scale score (or National Institutes of Health Stroke Scale scores 0-1) at 7 days poststroke. Safety outcomes included death, episodes of hyperglycemia, hypoglycemia, and adverse event. RESULTS: From April 2016 to June 2021, 350 patients were randomized (exenatide, n=177, standard care, n=173). Median age, 71 years (interquartile range, 62-79), median National Institutes of Health Stroke Scale score, 4 (interquartile range, 2-8). Planned recruitment (n=528) was stopped early due to COVID-19 disruptions and funding constraints. The primary outcome was achieved in 97 of 171 (56.7%) in the standard care group versus 104 of 170 (61.2%) in the exenatide group (adjusted odds ratio, 1.22 [95% CI, 0.79-1.88]; P=0.38). No differences in secondary outcomes were observed. The per-patient mean daily frequency of hyperglycemia was significantly less in the exenatide group across all quartiles. No episodes of hypoglycemia were recorded over the treatment period. Adverse events of mild nausea and vomiting occurred in 6 (3.5%) exenatide patients versus 0 (0%) standard care with no withdrawal. CONCLUSIONS: Treatment with exenatide did not reduce neurological impairment at 7 days in patients with acute ischemic stroke. Exenatide did significantly reduce the frequency of hyperglycemic events, without hypoglycemia, and was safe to use. Larger acute stroke trials using GLP-1 agonists such as exenatide should be considered. REGISTRATION: URL: www.australianclinicaltrials.gov.au; Unique identifier: ACTRN12617000409370. URL: https://www.clinicaltrials.gov; Unique identifier: NCT03287076.


Asunto(s)
Hiperglucemia , Hipoglucemia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Adulto , Humanos , Anciano , Exenatida/uso terapéutico , Accidente Cerebrovascular Isquémico/complicaciones , Estudios Prospectivos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/tratamiento farmacológico , Hiperglucemia/tratamiento farmacológico , Hiperglucemia/complicaciones , Hipoglucemia/complicaciones , Péptido 1 Similar al Glucagón/uso terapéutico , Resultado del Tratamiento
20.
Pilot Feasibility Stud ; 9(1): 171, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37814352

RESUMEN

BACKGROUND: Insulin pump therapy (IPT) improves glucose control in people with type 1 diabetes (T1D) compared with multiple daily injections (MDI). However, their size, the tethered insulin infusion set, intrusiveness when operating the device and the need to disconnect during showering limit their acceptance to many who may benefit. The Omnipod DASH® Insulin Management System is a small waterproof tubeless device which is wirelessly controlled by a handheld device which may be an acceptable alternative. However, there are no randomised controlled trials focusing on the impact on user perceptions of tubeless insulin pump therapy. This pilot study aims to assess study feasibility and acceptability of patch pump therapy compared with usual care in adults with T1D in Australia to inform power calculations and progression to a large-scale multi-site randomised controlled study. METHODS: A pilot multi-site parallel randomised controlled study will be conducted in sixty-four adults with T1D who are managed on MDI or IPT and self-monitoring with finger-stick blood glucose from four specialist diabetes centres in Victoria, Australia. Following carbohydrate counting education, participants will be randomised to use Omnipod DASH® System (Omnipod group) or continue usual care (usual care group) for 12 weeks, followed by a 12-week extension phase where all participants will use Omnipod DASH® System. The primary outcome measure is feasibility determined by study completion rates with a threshold of 0.80. Acceptability of the intervention (Omnipod DASH® System) will be assessed by the difference in Diabetes Technology Questionnaire 'current' (DTQ-current) score at 12 weeks post-randomisation compared to baseline. Secondary outcomes will include other measures of user acceptance, process outcomes, resource outcomes, participant-centred outcomes, healthcare professional perceptions and glycaemic outcomes. DISCUSSION: This pilot study will provide insights regarding the feasibility of the study design and the first data regarding user acceptance of insulin patch pump technology in Australian T1D adults. We anticipate that this study will provide information informing the design of a larger study evaluating the impact of patch pumps on subjective outcomes that are of significance to the person living with T1D. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ( https://anzctr.org.au/ ) ACTRN12621001195842 (8th September 2021). Please refer to Additional file 1: Appendix 1 for full details.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...